Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “positron”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Injection, confinement, and diagnosis of electrons and positrons in a permanent magnet dipole trap

Abstract Prerequisites for the goal of studying long-lived, magnetically confined, electron–positron pair plasmas in the laboratory include the injection of both species into the trap, long trapping times, and suitable diagnostic methods. Here we report recent progress on these tasks achieved in a simple dipole trap based on a supported permanent magnet. For the injection of electrons, both an $$\textbf{E}\times B$$ E × B drift technique (of a $$\sim $$ ∼ 2– $$\upmu $$ μ A, 6-eV beam) and “edge injection” (from a filament emitting a few mA and biased to some tens of volts) have been demonstrated; the former is suitable for low-density beams with smaller spatial and velocity spreads, while the latter employs fluctuations arising from collective behavior. To diagnose the edge-injected electrons, image potentials and currents induced on a wall probe, the magnet case, and wall electrodes were measured. Confinement of drift-injected positrons, measured experimentally, exhibited at least two well-separated timescales. Simulations reproduced this qualitatively, using a simple model of elastic collisions with residual background gas, and point to small adjustments for increasing trapping times. In a major upgrade to diagnostic capabilities, 25 bismuth germanate detectors, placed in three reentrant ports, are able to localize annihilation gammas, which will be used in future experiments to distinguish between different loss channels. Graphical abstract

von der Linden, J. (ORCID:0000000327477813)↗

Concept of a Positron Source at Ce+BAF

A concept of the Ce+BAF positron injector is presented. The positron activities are described and the results of e+ beam tracking and calculations of e+ polarizations are discussed.

Ushakov, Andriy↗

Capture Cavities for the CW Polarized Positron Source Ce+BAF

The initial design of the capture cavities for the continuous wave (CW) polarized positron beams at Jefferson Lab (Ce+BAF) is presented. A chain of standing wave multi-cell copper cavities inside a solenoid tunnel are selected to bunch/capture positrons. The cavity design strategy is presented to accommodate constrains from the large phase distribution of the incident beams, RF power, radiation and RF heating, beam loading, etc. to improve the capture efficiency. A matrix of design parameters' range are given for future system optimization when the capture cavities are considered together with other sub-systems and beam dynamics. The contents will also be useful for other CW cavity design for beams with large phase space distribution.

Wang, Shaoheng↗

Analytical Approximations for Beamstrahlung at Very High Energy Electron-Positron Colliders

Among the many effects that occur in beam-beam electron-positron collisions at TeV energies, emission of hard synchrotron radiation, or beamstrahlung, has special importance. Beamstrahlung determines the energy spectrum of the most energetic electrons, positrons, and photons and supplies the initial condition for the calculation of all other QED processes. In this paper, we show that the description of beamstrahlung simplifies in the limit of large quantum parameter $Υ$, which is realized in 10 TeV collider designs. The beamstrahlung spectra for electrons and photons are given in terms of universal functions. We supply approximations to these functions that will be useful for more general studies of the beam-beam interaction at very high energies.

Accelerator Physics (physics.acc-ph)↗

Precision measurement of positron decay modes of Xe-125 in the LUX-ZEPLIN experiment

The radioisotope $^{125}\text{Xe}$ is a short-lived ($T_{1/2}\sim16.9 h$) activation product of the neutron calibrations performed in the LUX-ZEPLIN experiment. Subsequently, $^{125}$Xe decays primarily ($>99\%$) via electron capture, but positron emission has been confirmed by direct measurement to at least the 243 keV level of $^{125}\text{I}$. An additional decay to the 188keV level is expected from triple-coincident measurements of the annihilation and relaxation $γ$ rays, but has not been directly confirmed. By utilizing multiple-scatter event analysis and the pre-activation data to constrain backgrounds, this work reports positron emission with a statistical significance of 5.5$σ$. This corresponds to a total branching ratio of $0.29\pm0.08_{\text{stat.}}\pm0.04_{\text{sys.}}$%, and is the first constraint to the individual branching levels of $^{125}\text{I}$.

Akerib, D. S. [SLAC; KIPAC, Menlo Park]↗

Dynamic Scaling Analysis of Accelerated Irradiation Testing on Additive Manufacturing Materials by Positron Annihilation

The timely applications of Additive Manufacturing (AM) materials in nuclear environments require accelerated irradiation tests, mainly ion irradiation to enable rapid prototyping. Low dose ion irradiation would cause sub-nanostructure changes by generation of lattice defects, vacancies, vacancy clusters and voids and void swelling caused by cellular dislocations. Positron Annihilation Lifetime (PAL), a novel technology, sensitive towards sub-nanostructure morphology with high accuracy (about 10-7 vacancy per atom), supported by Transition Electron Microscope (TEM) would be applied to identify the type and total size of the defects. The subsequent PAL measurements and TEM surface studies would be followed by PAL analysis that includes sophisticated trapping model. The PAS results would become an input to dynamic scaling analysis (that predicts radiation effects from low dose studies for high dose effects), which incorporate mean-field theory model. The final effect is an in-depth understanding of the microstructure evolution of AM materials under ion irradiation which can be extrapolated to the studies of neutron irradiation, since ion-irradiation takes less time and do not cause the irradiation hazard. The working hypothesis is that PAL technology, that have excellent sensitivity to low-defect concentration would help to identify ion-induced material damage on the atomic and nano-scale level, which then could be extrapolated to understand the neutron damage better.

accelerated irradiation testing↗

Tau Positron Emission Tomography for Predicting Dementia in Individuals With Mild Cognitive Impairment

An accurate prognosis is especially pertinent in mild cognitive impairment (MCI), when individuals experience considerable uncertainty about future progression. To evaluate the prognostic value of tau positron emission tomography (PET) to predict clinical progression from MCI to dementia. This was a multicenter cohort study with external validation and a mean (SD) follow-up of 2.0 (1.1) years. Data were collected from centers in South Korea, Sweden, the US, and Switzerland from June 2014 to January 2024. Participant data were retrospectively collected and inclusion criteria were a baseline clinical diagnosis of MCI; longitudinal clinical follow-up; a Mini-Mental State Examination (MMSE) score greater than 22; and available tau PET, amyloid-β (Aβ) PET, and magnetic resonance imaging (MRI) scan less than 1 year from diagnosis. A total of 448 eligible individuals with MCI were included (331 in the discovery cohort and 117 in the validation cohort). None of these participants were excluded over the course of the study. Exposures included Tau PET, Aβ PET, and MRI. Positive results on tau PET (temporal meta–region of interest), Aβ PET (global; expressed in the standardized metric Centiloids), and MRI (Alzheimer disease [AD] signature region) was assessed using quantitative thresholds and visual reads. Clinical progression from MCI to all-cause dementia (regardless of suspected etiology) or to AD dementia (AD as suspected etiology) served as the primary outcomes. The primary analyses were receiver operating characteristics. In the discovery cohort, the mean (SD) age was 70.9 (8.5) years, 191 (58%) were male, the mean (SD) MMSE score was 27.1 (1.9), and 110 individuals with MCI (33%) converted to dementia (71 to AD dementia). Only the model with tau PET predicted all-cause dementia (area under the receiver operating characteristic curve [AUC], 0.75; 95% CI, 0.70-0.80) better than a base model including age, sex, education, and MMSE score (AUC, 0.71; 95% CI, 0.65-0.77; P = .02), while the models assessing the other neuroimaging markers did not improve prediction. In the validation cohort, tau PET replicated in predicting all-cause dementia. Compared to the base model (AUC, 0.75; 95% CI, 0.69-0.82), prediction of AD dementia in the discovery cohort was significantly improved by including tau PET (AUC, 0.84; 95% CI, 0.79-0.89; P < .001), tau PET visual read (AUC, 0.83; 95% CI, 0.78-0.88; P = .001), and Aβ PET Centiloids (AUC, 0.83; 95% CI, 0.78-0.88; P = .03). In the validation cohort, only the tau PET and the tau PET visual reads replicated in predicting AD dementia. In this study, tau-PET showed the best performance as a stand-alone marker to predict progression to dementia among individuals with MCI. This suggests that, for prognostic purposes in MCI, a tau PET scan may be the best currently available neuroimaging marker.

59 BASIC BIOLOGICAL SCIENCES↗

Harmonizing tau positron emission tomography in Alzheimer's disease: The CenTauR scale and the joint propagation model

Abstract INTRODUCTION Tau‐positron emission tomography (PET) outcome data of patients with Alzheimer's disease (AD) cannot currently be meaningfully compared or combined when different tracers are used due to differences in tracer properties, instrumentation, and methods of analysis. METHODS Using head‐to‐head data from five cohorts with tau PET radiotracers designed to target tau deposition in AD, we tested a joint propagation model (JPM) to harmonize quantification (units termed “CenTauR” [CTR]). JPM is a statistical model that simultaneously models the relationships between head‐to‐head and anchor point data. JPM was compared to a linear regression approach analogous to the one used in the amyloid PET Centiloid scale. RESULTS A strong linear relationship was observed between CTR values across brain regions. Using the JPM approach, CTR estimates were similar to, but more accurate than, those derived using the linear regression approach. DISCUSSION Preliminary findings using the JPM support the development and adoption of a universal scale for tau‐PET quantification. Highlights Tested a novel joint propagation model (JPM) to harmonize quantification of tau PET. Units of common scale are termed “CenTauRs”. Tested a Centiloid‐like linear regression approach. Using five cohorts with head‐to‐head tau PET, JPM outperformed linearregressionbased approach. Strong linear relationship was observed between CenTauRs values across brain regions.

Neurosciences & Neurology↗

Positron emission tomography harmonization in the Alzheimer's Disease Neuroimaging Initiative: A scalable and rigorous approach to multisite amyloid and tau quantification

Abstract INTRODUCTION A key goal of the Alzheimer's Disease NeuroImaging Initiative (ADNI) positron emission tomography (PET) Core is to harmonize quantification of β‐amyloid (Aβ) and tau PET image data across multiple scanners and tracers. METHODS We developed an analysis pipeline (Berkeley PET Imaging Pipeline, B‐PIP) for ADNI Aβ and tau PET images and applied it to PET data from other multisite studies. Steps include image pre‐processing, refacing, magnetic resonance imaging (MRI)/PET co‐registration, visual quality control (QC), quantification of tracer uptake, and standardization of Aβ and tau standardized uptake value ratios (SUVrs) across tracers. RESULTS Measurements from 10,105 cross‐sectional and longitudinal Aβ and tau PET scans acquired in several studies between 2010 and 2024 can be processed, harmonized, and directly merged across tracers and cohorts. DISCUSSION The B‐PIP developed in ADNI is a scalable image harmonization approach used in several observational studies and clinical trials that facilitates rigorous Aβ and tau PET quantification and data sharing. Highlights Quantitative results from ADNI Aβ and tau PET data are generated using a rigorous, scalable image processing pipeline This pipeline has been applied to PET data from several other large, multisite studies and trials Quantitative outcomes are harmonizable across studies and are shared with the scientific community

Neurosciences & Neurology↗

Integrated positron emission particle tracking (PEPT) and X-ray computed tomography (CT) imaging of flow phenomena in twisted tape swirl flow

Abstract A combined positron emission particle tracking (PEPT) and X-ray computed tomography (CT) technique is presented, and its utility is demonstrated through investigation of flow in a pipe with twisted tape swirl insert with varying flow conditions (diameter-based Reynolds numbers 16,300–63,300). A description of this technique is given, as well as data handling practices used to relate geometric information captured by CT to fluid flow data gathered via PEPT. It is found that the CT component is readily capable of capturing the stainless steel insert geometry in this present system, but the use of combined plastic and metal materials leads to artifacts in imaging of the plastic surface. Nonetheless, CT data are related to PEPT flow measurements, and average velocity fields are calculated via a pseudo-framing and interpolation scheme and used to visualize and interrogate key flow phenomena within the system. Radial velocity profiles of the mean flow characteristics are seen to collapse to a nearly common form across all flow conditions considered. Helical vortices are seen propagating through the flow field, generated by bypass flow around the gap between the insert and pipe wall, with additional coherent secondary flow structures seen in the higher Reynolds number cases. These findings enhance the understanding of the mixing mechanisms in these swirl flows and encourage the continued development of PEPT-CT methodologies for 3D flow measurements in optically inaccessible systems.

42 ENGINEERING↗

Selected advances in the accelerator design of the Future Circular Electron-Positron Collider (FCC-ee)

In autumn 2023, the FCC Feasibility Study underwent a crucial “mid-term review”. We describe some accelerator performance risks for the proposed future circular electron-positron collider, FCC-ee, identified for, and during, the mid-term review. For the collider rings, these are the collective effects when running on the Z resonance – especially resistive wall, beam-beam, and electron cloud –, the beam lifetime, dynamic aperture, alignment tolerances, and beam-based alignment. For the booster, the primary concern is the vacuum system, with regard to impedance and effects of the residual gas. For the injector, the layout and the linac repetition rate are primary considerations. We discuss the various issues and report the planned mitigations.

43 PARTICLE ACCELERATORS↗

A High Intensity Spin-Polarized Electron Photogun to Drive a Polarized Positron Source

A photogun to generate a high-intensity, highly spin-polarized electron beam >90% with unprecedented charge lifetime in the kilocoulomb range is envisioned at JLab for a proposed Ce+BAF polarized positron beam source. The electron photogun is expected to provide a CW beam of >1 mA for a month without intervention. A limiting factor is ion-back bom-bardment on the strained-superlattice GaAs-photocathode which can be reduced by improving the photogun vacuum or biasing the anode. Additionally, increasing the laser spot size can help mitigate ion-induced damage. However, eventually the laser size becomes too large for the photogun electrode. An envisioned photogun design will incorporate larger electrodes to accommodate larger and off-center laser spot sizes. Compatible larger conical insulators which operate >300 kV for beam injection into a Beta~1 SRF booster are also necessary.

Hernandez Garcia, Carlos↗