Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “positioning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Iron Complexes Bearing Diphosphine Ligands with Positioned Pendant Amines as Electrocatalysts for the Oxidation of H2

The synthesis and spectroscopic characterization of CpC5F4NFe(PtBu2NBn2)Cl, [3-Cl] (where C5F4N is the tetrafluorpyridyl substituent and PtBu2NBn2 = 1,5-di(tert-butyl)-3,7-di(benzyl)-1,5-diaza-3,7-diphosphacyclooctane) are reported. Complex 3-Cl and previously reported [CpC5F4NFe(PtBu2NtBu2)Cl], 4-Cl, are precursors to intermediates in the catalytic oxidation of H2, including CpC5F4NFe(PtBu2NBn2)H (3-H), CpC5F4NFe(PtBu2NtBu2)H (4-H), [CpC5F4NFe(PtBu2NBn2)]BArF4 ([3](BArF4), [CpC5F4NFe(PtBu2NtBu2)]BArF4 ([4](BArF4), [CpC5F4NFe(PtBu2NBn2)(H2)]BArF4 ([3-H2]BArF4), and [CpC5F4NFe(PtBu2NtBu2H)H]BArF4 ([4-FeH(NH)]BArF4). All of these complexes were characterized by spectroscopic and electrochemical studies; 3-Cl, 3-H and 4-Cl were also characterized by single crystal diffraction studies. 3-H and 4-H are electrocatalysts for H2 (1.0 atm) oxidation in the presence of a excess of the amine base N-methylpyrrolidine, with turnover frequencies at 22 °C of 2.5 s-1 and 0.5 s-1, and overpotentials at Ecat/2 of 235 mV and 95 mV, respectively. Studies of individual chemical and/or electrochemical reactions of the various intermediates provide important insights into the factors governing the overall catalytic activity for H2 oxidation, and provide important insights into the role of the pendant base of the [FeFe] hydrogenase active site. This work was supported by the Center for Molecular Electrocatalysis, an Energy Frontier Research Center funded by the U.S. Department of Energy, Office of Science, Office of Basic Energy Sciences. Pacific Northwest National Laboratory is operated by Battelle for the U.S. Department of Energy.

catalysis, iron, hydrogen↗

Heterolytic Cleavage of H2 by Bifunctional Manganese(I) Complexes: Impact of Ligand Dynamics, Electrophilicity, and Base Positioning

We report the synthesis, characterization, and reactivity with H2 of a series of MnI complexes of the type [(P-P)Mn(L2)CO]+ (L2 = dppm, bppm, or (CO)2; P-P = PPhNMePPh or PPh2 NBn2 ) that bear pendant amine ligands designed to function as proton relays. The pendant amine was found to function as a hemilabile ligand; its binding strength is strongly affected by the ancillary ligand environment around Mn. Tuning the electrophilicity of the Mn center leads to systems capable of reversible heterolytic cleavage of the H-H bond. The strength of pendant amine binding can be balanced to protect the Mn center while still leading to facile reactivity with H2. Neutral amine-bearing MnIH species were found to react with one-electron oxidants and, after proton and electron transfer reactions, regenerate MnI cationic species. The reactivity presented herein indicate that the Mn complexes we have developed are a promising platform for Mn-based H2 oxidation electrocatalyst development. The research was supported as part of the Center for Molecular Electrocatalysis, an Energy Frontier Research Center funded by the U.S. Department of Energy, Office of Science, Office of Basic Energy Sciences. Pacific Northwest National Laboratory is operated by Battelle for DOE.

electrochemistry↗

On the absence of a positive sound dispersion in the THz dynamics of glycerol: an inelastic x-ray scattering study

The high frequency transport properties of glycerol are derived from inelastic x-ray scattering spectra measured at different pressures and compared with ultrasound absorption data. As a result, the presence of two distinct relaxation processes is inferred: a slow one, occurring in the GHz window and having an essentially structural character, and a fast one, related instead to microscopic degrees of freedom. While the former originates a neat increase of the apparent, i.e. frequency-dependent, sound velocity, the latter induces no visible dispersive effects on the acoustic propagation. The observed behavior is likely paradigmatic of all glass formers near or below the melting and it is here discussed and explained in some detail.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Geometry of sets of quantum maps: A generic positive map acting on a high-dimensional system is not completely positive

We investigate the set (a) of positive, trace preserving maps acting on density matrices of size N and a sequence of its nested subsets: the sets of maps which are (b) decomposable, (c) completely positive, and (d) extended by identity impose positive partial transpose and (e) are superpositive. Working with the Hilbert-Schmidt (Euclidean) measure, we derive tight explicit two-sided bounds for the volumes of all five sets. A sample consequence is the fact that, as N increases, a generic positive map becomes not decomposable and, a fortiori, not completely positive. Due to the Jamiolkowski isomorphism, the results obtained for quantum maps are closely connected to similar relations between the volume of the set of quantum states and the volumes of its subsets (such as states with positive partial transpose or separable states) or supersets. Our approach depends on the systematic use of duality to derive quantitative estimates and on various tools of classical convexity, high-dimensional probability, and geometry of Banach spaces, some of which are not standard.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A real-time applicator position monitoring system for gynecologic intracavitary brachytherapy

Purpose: To develop a real-time applicator position monitoring system (RAPS) for intracavitary brachytherapy using an infrared camera and reflective markers. Methods: 3D image-guided brachytherapy requires high accuracy of applicator localization; however, applicator displacement can happen during patient transfer for imaging and treatment delivery. No continuous applicator position monitoring system is currently available. The RAPS system was developed for real-time applicator position monitoring without additional radiation dose to patients. It includes an infrared camera, reflective markers, an infrared illuminator, and image processing software. After reflective markers are firmly attached to the applicator and the patient body, applicator displacement can be measured by computing the relative change in distance between the markers. The reflective markers are magnetic resonance imaging (MRI) compatible, which is suitable for MRI-guided HDR brachytherapy paradigm. In our prototype, a Microsoft Kinect sensor with a resolution of 640 by 480 pixels is used as an infrared camera. A phantom study was carried out to compare RAPS' measurements with known displacements ranging from −15 to +15 mm. A reproducibility test was also conducted. Results: The RAPS can achieve 4 frames/s using a laptop with Intel{sup ®} Core™2 Duo processor. When the pixel size is 0.95 mm, the difference between RAPS' measurements and known shift values varied from 0 to 0.8 mm with the mean value of 0.1 mm and a standard deviation of 0.44 mm. The system reproducibility was within 0.6 mm after ten reposition trials. Conclusions: This work demonstrates the feasibility of a real-time infrared camera based gynecologic intracavitary brachytherapy applicator monitoring system. Less than 1 mm accuracy is achieved when using an off-the-shelf infrared camera.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Positioning Accuracy in Stereotactic Radiotherapy Using a Mask System With Added Vacuum Mouth Piece and Stereoscopic X-Ray Positioning

Purpose: For cranial patients receiving stereotactic radiotherapy, we use the Exactrac stereoscopic X-ray system to optimize patient positioning. Patients are immobilized with the BrainLAB Mask System (BrainLAB, Feldkirchen, Germany). We have developed an adapter to this system that accommodates a vacuum mouth piece (VMP). Measurements with the Exactrac system have been performed to study the positioning accuracy after corrections with this system and to evaluate the accuracy of the VMP vs. the standard available upper jaw support (UJS). Methods and Materials: Positioning results were collected for 20 patients with the UJS and 20 patients with the VMP, before treatment (1,122 fractions) and after treatment (400 fractions). For all 6 degrees of freedom the average, the random error and systematic error were calculated. Results: The average vector length before and after correction with the Exactrac system was 2.1 {+-} 1.2 mm and 0.7 {+-} 0.6 mm respectively for UJS and 1.7 {+-} 0.7 mm and 0.4 {+-} 0.4 mm for VMP. Interfraction positioning for translations was greatly improved after correction with the Exactrac system (p < 0.0005) and is better with VMP than with UJS (p = 0.005). Outliers were greatly reduced. Interfraction rotations were significantly smaller for VMP. Intrafraction errors for vertical and longitudinal translations and for rotations were smaller for the VMP. Conclusions: Positioning correction using the Exactrac X-ray system greatly improves accuracy. Adding the VMP results in even better patient fixation and smaller rotations, making it a useful addition to the Mask System. Combined, this is a convenient and accurate alternative to invasive fixation methods.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A new waveform analysis technique to extract good energy and position resolution from a dual-axis duo-lateral position-sensitive detector

The dual-axis duo-lateral position-sensitive silicon detector was developed to detect charged particles with high quality position and energy resolution. When these detectors were used with conventional signal processing electronics, an empirically determined correction was used to improve energy resolution. In this work, the waveforms from the detector after preamplification are studied in detail to investigate position information contained in the waveforms. A 7.22 MeV/nucleon alpha particle beam was impinged directly on a masked dual-axis duo-lateral detector. Data obtained using a 228 Th alpha particle source was also used. Here, by studying the waveform characteristics that give rise to the position-dependent distortions, a new summed trigger analysis method has been developed to significantly improve linearity in position reconstruction without sacrificing energy resolution.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Combined Modality Treatment for PET-Positive Non-Hodgkin Lymphoma: Favorable Outcomes of Combined Modality Treatment for Patients With Non-Hodgkin Lymphoma and Positive Interim or Postchemotherapy FDG-PET

Purpose: To evaluate outcomes of patients treated for aggressive non-Hodgkin lymphoma (NHL) with combined modality therapy based on [{sup 18}F]fluoro-2-deoxy-2-D-glucose positron emission tomography (FDG-PET) response. Methods and Materials: We studied 59 patients with aggressive NHL, who received chemotherapy and radiation therapy (RT) from 2001 to 2008. Among them, 83% of patients had stage I/II disease. Patients with B-cell lymphoma received R-CHOP (rituximab, cyclophosphamide, doxorubicin, vincristine, and prednisone)-based chemotherapy, and 1 patient with anaplastic lymphoma kinase-negative anaplastic T-cell lymphoma received CHOP therapy. Interim and postchemotherapy FDG-PET or FDG-PET/computed tomography (CT) scans were performed for restaging. All patients received consolidated involved-field RT. Median RT dose was 36 Gy (range, 28.8-50 Gy). Progression-free survival (PFS) and local control (LC) rates were calculated with and without a negative interim or postchemotherapy FDG-PET scan. Results: Median follow-up was 46.5 months. Thirty-nine patients had negative FDG-PET results by the end of chemotherapy, including 12 patients who had a negative interim FDG-PET scan and no postchemotherapy PET. Twenty patients were FDG-PET-positive, including 7 patients with positive interim FDG-PET and no postchemotherapy FDG-PET scans. The 3-year actuarial PFS rates for patients with negative versus positive FDG-PET scans were 97% and 90%, respectively. The 3-year actuarial LC rates for patients with negative versus positive FDG-PET scans were 100% and 90%, respectively. Conclusions: Patients who had a positive interim or postchemotherapy FDG-PET had a PFS rate of 90% at 3 years after combined modality treatment, suggesting that a large proportion of these patients can be cured with consolidated RT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Residual position errors of lymph node surrogates in breast cancer adjuvant radiotherapy: Comparison of two arm fixation devices and the effect of arm position correction

Residual position errors of the lymph node (LN) surrogates and humeral head (HH) were determined for 2 different arm fixation devices in radiotherapy (RT) of breast cancer: a standard wrist-hold (WH) and a house-made rod-hold (RH). The effect of arm position correction (APC) based on setup images was also investigated. A total of 113 consecutive patients with early-stage breast cancer with LN irradiation were retrospectively analyzed (53 and 60 using the WH and RH, respectively). Residual position errors of the LN surrogates (Th1-2 and clavicle) and the HH were investigated to compare the 2 fixation devices. The position errors and setup margins were determined before and after the APC to investigate the efficacy of the APC in the treatment situation. A threshold of 5 mm was used for the residual errors of the clavicle and Th1-2 to perform the APC, and a threshold of 7 mm was used for the HH. The setup margins were calculated with the van Herk formula. Irradiated volumes of the HH were determined from RT treatment plans. With the WH and the RH, setup margins up to 8.1 and 6.7 mm should be used for the LN surrogates, and margins up to 4.6 and 3.6 mm should be used to spare the HH, respectively, without the APC. After the APC, the margins of the LN surrogates were equal to or less than 7.5/6.0 mm with the WH/RH, but margins up to 4.2/2.9 mm were required for the HH. The APC was needed at least once with both the devices for approximately 60% of the patients. With the RH, irradiated volume of the HH was approximately 2 times more than with the WH, without any dose constraints. Use of the RH together with the APC resulted in minimal residual position errors and setup margins for all the investigated bony landmarks. Based on the obtained results, we prefer the house-made RH. However, more attention should be given to minimize the irradiation of the HH with the RH than with the WH.

61 RADIATION PROTECTION AND DOSIMETRY↗

HIERARCHICAL STRUCTURE OF MAGNETOHYDRODYNAMIC TURBULENCE IN POSITION-POSITION-VELOCITY SPACE

Magnetohydrodynamic turbulence is able to create hierarchical structures in the interstellar medium (ISM) that are correlated on a wide range of scales via the energy cascade. We use hierarchical tree diagrams known as dendrograms to characterize structures in synthetic position-position-velocity (PPV) emission cubes of isothermal magnetohydrodynamic turbulence. We show that the structures and degree of hierarchy observed in PPV space are related to the presence of self-gravity and the global sonic and Alfvenic Mach numbers. Simulations with higher Alfvenic Mach number, self-gravity and supersonic flows display enhanced hierarchical structure. We observe a strong dependency on the sonic and Alfvenic Mach numbers and self-gravity when we apply the statistical moments (i.e., mean, variance, skewness, kurtosis) to the leaf and node distribution of the dendrogram. Simulations with self-gravity, larger magnetic field and higher sonic Mach number have dendrogram distributions with higher statistical moments. Application of the dendrogram to three-dimensional density cubes, also known as position-position-position (PPP) cubes, reveals that the dominant emission contours in PPP and PPV are related for supersonic gas but not for subsonic. We also explore the effects of smoothing, thermal broadening, and velocity resolution on the dendrograms in order to make our study more applicable to observational data. These results all point to hierarchical tree diagrams as being a promising additional tool for studying ISM turbulence and star forming regions for obtaining information on the degree of self-gravity, the Mach numbers and the complicated relationship between PPV and PPP data.

79 ASTRONOMY AND ASTROPHYSICS↗

Identification of proteins capable of metal reduction from the proteome of the Gram‐positive bacterium D esulfotomaculum reducens MI ‐1 using an NADH ‐based activity assay

Summary Understanding of microbial metal reduction is based almost solely on studies of G ram‐negative organisms. In this study, we focus on D esulfotomaculum reducens MI ‐1, a G ram‐positive metal reducer whose genome lacks genes with similarity to any characterized metal reductase. Using non‐denaturing separations and mass spectrometry identification, in combination with a colorimetric screen for chelated F e( III )‐ NTA reduction with NADH as electron donor, we have identified proteins from the D . reducens proteome not previously characterized as iron reductases. Their function was confirmed by heterologous expression in E scherichia coli . Furthermore, we show that these proteins have the capability to reduce soluble C r( VI ) and U ( VI ) with NADH as electron donor. The proteins identified are NADH : flavin oxidoreductase ( D red_2421) and a protein complex composed of oxidoreductase flavin adenine dinucleotide/ NAD ( P )‐binding subunit ( D red_1685) and dihydroorotate dehydrogenase 1B ( D red_1686). D red_2421 was identified in the soluble proteome and is predicted to be a cytoplasmic protein. D red_1685 and D red_1686 were identified in both the soluble as well as the insoluble protein fraction, suggesting a type of membrane association, although PSORTb predicts both proteins are cytoplasmic. This study is the first functional proteomic analysis of D . reducens and one of the first analyses of metal and radionuclide reduction in an environmentally relevant G ram‐positive bacterium.

Otwell, Anne Elyse↗

Polarization Type Potential Induced Degradation under Positive Bias in a Commercial PERC Module: Preprint

Potential induced degradation of the polarization type (PID-p) can reduce module performance in a relatively short period of time. PID-p can occur at both voltage polarities, but most studies are focused on degradation under a negative bias. This paper uses commercial bifacial passivated emitter and rear contact (PERC) cells within a monofacial glass-backsheet module construction to evaluate the impact of PID-p under a positive bias on the front side. Using the aluminum-foil (Al-foil) method, the module was stressed for PID in an environmental chamber. After the stress, the maximum power (Pmax) showed a decline of 3.1% at 1000 W/m2 and 6.2% at 200 W/m2. Recovery under light was also investigated. Complete recovery was observed at high irradiance, while a partial recovery was seen at lower irradiance. The outcomes of this study can help in understanding PID-p degradation under a positive bias and its recovery under the light.

PERC↗

Generalized quantum Fokker-Planck equation for photoinduced nonequilibrium processes with positive definiteness condition

This work provides a detailed derivation of a generalized quantum Fokker-Planck equation (GQFPE) appropriate for photo-induced quantum dynamical processes. The path integral method pioneered by Caldeira and Leggett (CL) [Physica A 121, 587 (1983)] is extended by utilizing a nonequilibrium influence functional applicable to different baths for the ground and the excited electronic states. Both nonequilibrium and non-Markovian effects are accounted for consistently by expanding the paths in the exponents of the influence functional up to the second order with respect to time. This procedure results in approximations involving only single time integrations for the exponents of the influence functional but with additional time dependent boundary terms that have been ignored in previous works. The boundary terms complicate the derivation of a time evolution equation but do not affect position dependent physical observables or the dynamics in the steady state limit. For an effective density operator with the boundary terms factored out, a time evolution equation is derived, through short time expansion of the effective action and Gaussian integration in analytically continued complex domain of space. This leads to a compact form of the GQFPE with time dependent kernels and additional terms, which renders the resulting equation to be in the Dekker form [Phys. Rep. 80, 1 (1981)]. Major terms of the equation are analyzed for the case of Ohmic spectral density with Drude cutoff, which shows that the new GQFPE satisfies the positive definiteness condition in medium to high temperature limit. Steady state limit of the GQFPE is shown to approach the well-known expression derived by CL in the high temperature and Markovian bath limit and also provides additional corrections due to quantum and non-Markovian effects of the bath.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Triple-Negative or HER2-Positive Status Predicts Higher Rates of Locoregional Recurrence in Node-Positive Breast Cancer Patients After Mastectomy

Purpose: To evaluate the prognostic value of determining estrogen receptor (ER), progesterone receptor (PR), and human epidermal growth factor 2 (HER2) expression in node-positive breast cancer patients treated with mastectomy. Methods and Materials: The records of 835 node-positive breast cancer patients who had undergone mastectomy between January 2000 and December 2004 were analyzed retrospectively. Of these, 764 patients (91.5%) received chemotherapy; 68 of 398 patients (20.9%) with T1-2N1 disease and 352 of 437 patients (80.5%) with T3-4 or N2-3 disease received postoperative radiotherapy. Patients were classified into four subgroups according to hormone receptor (Rec+ or Rec-) and HER2 expression profiles: Rec-/HER2- (triple negative; n = 141), Rec-/HER2+ (n = 99), Rec+/HER2+ (n = 157), and Rec+/HER2- (n = 438). The endpoints were the duration of locoregional recurrence-free survival, distant metastasis-free survival, disease-free survival, and overall survival. Results: Patients with triple-negative, Rec-/HER2+, and Rec+/HER2+ expression profiles had a significantly lower 5-year locoregional recurrence-free survival than those with Rec+/HER2- profiles (86.5% vs. 93.6%, p = 0.002). Compared with those with Rec+/HER2+ and Rec+/HER2- profiles, patients with Rec-/HER2- and Rec-/HER2+ profiles had significantly lower 5-year distant metastasis-free survival (69.1% vs. 78.5%, p = 0.000), lower disease-free survival (66.6% vs. 75.6%, p = 0.000), and lower overall survival (71.4% vs. 84.2%, p = 0.000). Triple-negative or Rec-/HER2+ breast cancers had an increased likelihood of relapse and death within the first 3 years after treatment. Conclusions: Triple-negative and HER2-positive profiles are useful markers of prognosis for locoregional recurrence and survival in node-positive breast cancer patients treated with mastectomy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Optimizing the position resolution of a Z-stack microchannel plate resistive anode detector for low intensity signals

A method for achieving good position resolution of low-intensity electron signals using a microchannel plate resistive anode detector is demonstrated. Electron events at a rate of 7 counts s{sup −1} are detected using a Z-stack microchannel plate. The dependence of position resolution on both the distance and the potential difference between the microchannel plate and resistive anode is investigated. Using standard commercial electronics, a measured position resolution of 170 μm (FWHM) is obtained, which corresponds to an intrinsic resolution of 157 μm (FWHM)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An all-diamond X-ray position and flux monitor using nitrogen-incorporated ultra-nanocrystalline diamond contacts

Diamond X-ray detectors with conducting nitrogen-incorporated ultra-nanocrystalline diamond (N-UNCD) films as electrodes were fabricated to measure X-ray beam flux and position. Structural characterization and functionality tests were performed for these devices. The N-UNCD films grown on unseeded diamond substrates were compared with N-UNCD films grown on a seeded silicon substrate. Here, the feasibility of the N-UNCD films acting as electrodes for X-ray detectors was confirmed by the stable performance in a monochromatic X-ray beam. The fabrication process is able to change the surface status which may influence the signal uniformity under low bias, but this effect can be neglected under full collection bias.

43 PARTICLE ACCELERATORS↗