Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “point source sensitivity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Optical system design for a Lunar Optical Interferometer

The moon offers particular advantages for interferometry, including a vacuum environment, a large stable base on which to assemble multi-kilometer baselines, and a cold nighttime temperature to allow for passive cooling of optics for high IR sensitivity. A baseline design for a Lunar Optical Interferometer (LOI) which exploits these features is presented. The instrument operates in the visible to mid-IL region, and is designed for both astrometry and synthesis imaging. The design uses a Y-shaped array of 12 siderostats, with maximum arm lengths of about 1 km. The inner siderostats are monitored in three dimensions from a central laser metrology structure to allow for high precision astrometry. The outer siderostats, used primarily for synthesis imaging, exploit the availability of bright reference stars in order to determine the instrument geometry. The path delay function is partitioned into coarse and fine components, the former accomplished with switched banks of range mirrors monitored with an absolute laser metrology system, and the latter with a short cat's eye delay line. The back end of the instrument is modular, allowing for beam combiners for astrometry, visible and IR synthesis imaging, and direct planet detection. With 1 m apertures, the instrument will have a point-source imaging sensitivity of about 29 mag; with the laser metrology system, astrometry at the microarcsecond level will be possible.

Colavita, M. M.↗

The Einstein Observatory and future X-ray telescopes

A history of the events leading to the development and flight of the Einstein Observatory is given. The advantages of using grazing-incidence telescopes for solar and extrasolar X-ray astronomy is first discussed and followed by a description of the HEAO program. The Einstein Observatory marks a departure from the manner in which X-ray investigations are carried out, from individual experiments to the shared use of large facilities. The Observatory has achieved a sensitivity to point sources of 10 to the -14th erg/sq cm-sec in the 1-3 keV band, a flux 500 times smaller than previously detected and about 10 million times smaller than that of the first extrasolar source detected in 1962. The design philosophy of the Observatory entails three principles: (1) the unified scientific approach, (2) the establishment of spacecraft requirements at lowest acceptable levels that still allow operating flexibility, and (3) the idea of 'soft' rather than 'hard' failure. The mirror design, including the high resolution imager, the imaging proportional counter, and the solid-state and focal plane crystal spectrometers, is also given. An account of the struggle to gain acceptance by the scientific community and the funding agencies of the need for the Einstein Observatory mission is discussed. Finally, results of observations made by the Observatory are presented in detail, along with plans for future observation experiments.

Giacconi, R.↗

Modeling the stellar contribution to the Galactic component of the diffuse soft X-ray background. I - Background fluxes and number counts

A combination of a stellar Galaxy model based on optical data, stellar X-ray luminosity functions derived from the full Einstein base, and a model for X-ray absorption derived from hydrogen column densities are used to estimate the contribution to the diffuse soft X-ray background flux from the main-sequence A, F, G, K, and M stars, and RS CVn stars, at various energies ranging from 0.1 to about 5 keV. Previous discrepancies between earlier estimates of the stellar contribution to the diffuse soft X-ray background are resolved; this stellar contribution to the diffuse soft X-ray background is found to be under 3 percent for photon energies less than energy I and J bands (about 0.8-2 keV), at a threshold sensitivity for point source detection about 10 exp -10 ergs/s sq cm. At low latitudes, stellar contribution estimates are less than 3 percent below 0.3 keV, 7-40 percent in the medium-energy bands, and 27-70 percent in the I and J bands. It is shown that while dM stars are the major contributors to the diffuse stellar flux, other stellar types contribute as much as 40 percent of this flux at the higher energies in the passband studied.

Kashyap, V.↗

IRAS observations of galaxies in the Virgo cluster area

IRAS data on 196 galaxies in the area of the Virgo Cluster are presented. The data derive from combining all available survey observations for each object and therefore achieve greater sensitivity than the IRAS Point Source Catalog (PSC). The enhanced sensitivity allows 78 galaxies to be detected at 12 microns, 82 at 25 microns, 139 at 60 microns, and 135 at 100 microns, compared to 16, 23, 88, and 95 detections listed in the PSC. From the blue compact dwarf galaxy sample, 23 and 19 objects are detected at 60 and 100 microns, compared to three and two detections listed in the PSC. The emission in three close pairs of galaxies which are reported as single sources in the PSC are separated here. These statistics demonstrate the importance and potential of a detailed examination of IRAS data, especially for possibly resolved sources and, in particular, for galaxies out to redshifts of 0.008 or galaxies with D(25) of 3 arcmin or greater.

Helou, George↗

Point Source Polarimetry with the Gemini Planet Imager: Sensitivity Characterization with T5.5 Dwarf Companion HD 19467 B

Detecting polarized light from self-luminous exoplanets has the potential to provide key information about rotation, surface gravity, cloud grain size, and cloud coverage. While field brown dwarfs with detected polarized emission are common, no exoplanet or substellar companion has yet been detected in polarized light. With the advent of high contrast imaging spectro-polarimeters such as GPI and SPHERE, such a detection may now be possible with careful treatment of instrumental polarization. In this paper, we present 28 minutes of H-band GPI polarimetric observations of the benchmark T5.5 companion HD 19467 B. We detect no polarization signal from the target, and place an upper limit on the degree of linear polarization of pCL99:73% less than 1:7%. We discuss our results in the context of T dwarf cloud models and photometric variability.

Gemini Planet Imager↗

Neutrinos from neutron stars

A calculation of the flux of ultra-high energy neutrinos from galactic neutron stars is presented. The calculation is used to determine the number of point sources detectable at the sensitivity threshold of a proposed deep underwater muon and neutrino detector array. The detector array would have a point source detection threshold of about 100 eV/sq cm-sec. Analysis of neutrino luminosities and the number of detectable sources suggests that the deep underwater detector may make a few discoveries. In particular, a suspected neutron star in the Cyg X-3 source seems a promising target for the deep underwater array.

Helfand, D. J.↗

The AXAF CCD imaging spectrometer

The AXAF CCD Imaging Spectrometer (ACIS) is currently being defined as a possible focal plane instrument to be flown on the Advanced X-ray Astrophysics Facility (AXAF). The imaging spectrometer consists of an array of charge coupled devices (CCD's) to be placed at the focus of the AXAF mirrors. The array will provide high angular resolution (0.5 arc seconds), moderate spectral resolution (150 eV) over the energy range 0.1 to 10 keV, temporal resolution down to 60 microseconds, and single photon quantum detection efficiencies of up to 90 percent. X-ray sensitivity for a point source exceeds 10 to the -15th ergs/sq cm sec for a 10 to the 5th sec exposure. When used in conjunction with the objective gratings, the array will yield wavelength resolution of up to 200.

Garmire, G. P.↗

Detection of point sources with spark chamber gamma-ray telescopes

The sensitivity of cross correlation and maximum likelihood, two methods under consideration by the EGRET team for detecting point sources, is analyzed numerically. Cross correlation is found to be 9 +/- 2 percent more sensitive than maximum likelihood.

Mattox, J. R.↗

Limits on Arcminute Scale Cosmic Microwave Background Anisotropy with the BIMA Array

We have used the Berkeley-Illinois-Maryland-Association (BIMA) millimeter array outfitted with sensitive cm-wave receivers to search for Cosmic Microwave Background (CMB) anisotropies on arcminute scales. The interferometer was placed in a compact configuration which produces high brightness sensitivity, while providing discrimination against point sources. Operating at a frequency of 28.5 GHz, the FWHM primary beam of the instrument is 6.6 arcminutes. We have made sensitive images of seven fields, five of which where chosen specifically to have low IR dust contrast and be free of bright radio sources. Additional observations with the Owens Valley Radio Observatory (OVRO) millimeter array were used to assist in the location and removal of radio point sources. Applying a Bayesian analysis to the raw visibility data, we place limits on CMB anisotropy flat-band power Q_flat = 5.6 (+3.0, -5.6) uK and Q_flat < 14.1 uK at 68% and 95% confidence. The sensitivity of this experiment to flat band power peaks at a multipole of l = 5470, which corresponds to an angular scale of approximately 2 arcminutes The most likely value of Q_flat is similar to the level of the expected secondary anisotropies.

Holzapfel, W. L.↗

Science Instrument Sensitivities to Radioisotope Power System Environment

Radioisotope Power Systems (RPS) have been and will be enabling or significantly enhancing for many missions, including several concepts identified in the 2011 Planetary Science Decadal Survey. Some mission planners and science investigators might have concerns about possible impacts from RPS-induced conditions upon the scientific capabilities of their mission concepts. To alleviate these concerns, this paper looks at existing and potential future RPS designs, and examines their potential radiation, thermal, vibration, electromagnetic interference (EMI), and magnetic fields impacts on representative science instruments and science measurements. Radiation impacts from RPS on science instruments are of potential concern for instruments with optical detectors and instruments with high-voltage electronics. The two main areas of concern are noise effects on the instrument measurements, and long-term effects of instrument damage. While RPS by their nature will contribute to total radiation dose, their addition for most missions should be relatively small. For example, the gamma dose rate from one Multi-Mission Radioisotope Thermoelectric Generator (MMRTG) would be an order of magnitude lower than the environmental dose rate at Mars, and would have a correspondingly lower contribution to instrument noise and to any permanent damage to payload sensors. Increasing the number of General Purpose Heat Source (GPHS) modules used in an RPS would be expected to increase the generated radiation proportionally; however, the effect of more GPHS modules is mitigated from a strictly linear relationship by self-shielding effects. The radiation field of an RPS is anisotropic due to the deviation of the modules from a point-source-geometry. For particularly sensitive instruments the total radiation dose could be mitigated with separation or application of spot shielding. Though a new, higher-power RPS could generate more heat per unit than current designs, thermal impact to the flight system could be mitigated with shading and pointing if required by the mission. Alternatively, excess heat could prove beneficial in providing needed heat to spacecraft components and instruments in some thermal environments. Vibration for a new higher-power Stirling Radioisotope Generator (SRG) would be expected to be similar to the recent Advanced Stirling Radioisotope Generator (ASRG) design. While vibration should be low, it must be considered and addressed during spacecraft and instrument design. EMI and magnetic fields for new RPS concepts are expected to be low as for the current RPS, but must be considered and addressed if the mission includes sensitive instruments such as magnetometers. The assessment conducted for this paper focused on orbiter instrument payloads for two representative mission concepts- a Titan Saturn System Mission (TSSM) and a Uranus Orbiter and Probe (UOP)-since both of these Decadal Survey concepts would include many diverse instruments on board. Quick-look design studies using notional new RPS concepts were carried out for these two mission concepts, and their specific instrument packages were analyzed for their interactions with new RPS designs. The original Decadal Survey TSSM and UOP concepts did not have complete instrument performance requirements so typical measurement requirements were used where needed. Then, the general RPS environments were evaluated for impacts to various types of instruments. This paper describes how the potential impacts of the RPS on science instruments and measurements were assessed, which impacts were addressed, proposed mitigation strategies against those impacts, and provides an overview of future work.

RPS↗

Limits on Arcminute-Scale Cosmic Microwave Background Anisotropy at 28.5 GHz

We have used the Berkeley-Illinois-Maryland Association (BIMA) millimeter array outfitted with sensitive centimeter-wave receivers to search for cosmic microwave background (CMB) anisotropies on arcminute scales. The interferometer was placed in a compact configuration that produces high brightness sensitivity, while providing discrimination against point sources. Operating at a frequency of 28.5 GHz, the FWHM primary beam of the instrument is approximately 6'.6. We have made sensitive images of seven fields, four of which where chosen specifically to have low infrared dust contrast and to be free of bright radio sources. Additional observations with the Owens Valley Radio Observatory (OVRO) millimeter array were used to assist in the location and removal of radio point sources. Applying a Bayesian analysis to the raw visibility data, we place limits on CMB anisotropy flat-band power of Q(sub flat) = 5.6(sub -5.6)(exp 3.0) microK and Q(sub flat) < 14.1 microK at 68% and 95% confidence, respectively. The sensitivity of this experiment to flat-band power peaks at a multipole of I = 5470, which corresponds to an angular scale of approximately 2'. The most likely value of Q(sub flat) is similar to the level of the expected secondary anisotropies.

Holzapfel, W. L.↗

Two southern SNR: G327.1-1.1 and Kes 27

Astronomical observations showed that the supernova remnants G 327.1-1.1 and the G 327.4+0.4 (Kes 27), located in the constellation Norma, are both irregular, filled-center X-ray sources with possible point sources superimposed. Rosat position sensitive proportional counter (PSPC) observations map the diffuse structure and show the unresolved sources in each field. Both remnants have bright emitting regions inside the limb, indicating the presence of high energy electrons accelerated by a pulsar. This energy bright interior region is more prominent in G 327.1-1.1 than in Kes 27.

Seward, F. D.↗

Description and Sensitivity Analysis of the SOLSE/LORE-2 and SAGE III Limb Scattering Ozone Retrieval Algorithms

The SOLSE (Shuttle Ozone Limb Sounding Experiment) and LORE (Limb Ozone Retrieval Experiment) instruments are scheduled for reflight on Space Shuttle flight STS-107 in July 2002. In addition, the SAGE III (Stratospheric Aerosol and Gas Experiment) instrument will begin to make limb scattering measurements during Spring 2002. The optimal estimation technique is used to analyze visible and ultraviolet limb scattered radiances and produce a retrieved ozone profile. The algorithm used to analyze data from the initial flight of the SOLSE/LORE instruments (on Space Shuttle flight STS-87 in November 1997) forms the basis of the current algorithms, with expansion to take advantage of the increased multispectral information provided by SOLSE/LORE-2 and SAGE III. We also present detailed sensitivity analysis for these ozone retrieval algorithms. The primary source of ozone retrieval error is tangent height misregistration (i.e., instrument pointing error), which is relevant throughout the altitude range of interest, and can produce retrieval errors on the order of 10-20 percent due to a tangent height registration error of 0.5 km at the tangent point. Other significant sources of error are sensitivity to stratospheric aerosol and sensitivity to error in the a priori ozone estimate (given assumed instrument signal-to-noise = 200). These can produce errors up to 10 percent for the ozone retrieval at altitudes less than 20 km, but produce little error above that level.

Loughman, R.↗

The effects of correlated noise in phased-array observations of radio sources

Arrays of radio telescopes are now routinely used to provide increased signal-to-noise when observing faint point sources. However, calculation of the achievable sensitivity is complicated if there are sources in the field of view other than the target source. These additional sources not only increase the system temperatures of the individual antennas, but may also contribute significant 'correlated noise' to the effective system temperature of the array. This problem has been of particular interest in the context of tracking spacecraft in the vicinity of radio-bright planets (e.g., Galileo at Jupiter), but it has broader astronomical relevance as well. This paper presents a general formulation of the problem, for the case of a point-like target source in the presence of an additional radio source of arbitrary brightness distribution. We re-derive the well known result that, in the absence of any background sources, a phased array of N indentical antennas is a factor of N more sensitive than a single antenna. We also show that an unphased array of N identical antennas is, on average, no more sensitive than a single antenna if the signals from the individual antennas are combined prior to detection. In the case where a background source is present we show that the effects of correlated noise are highly geometry dependent, and for some astronomical observations may cause significant fluctuations in the array's effective system temperature.

Dewey, Rachel J.↗

Laboratory evaluation of the pointing stability of the ASPS Vernier System

The annular suspension and pointing system (ASPS) is an end-mount experiment pointing system designed for use in the space shuttle. The results of the ASPS Vernier System (AVS) pointing stability tests conducted in a laboratory environment are documented. A simulated zero-G suspension was used to support the test payload in the laboratory. The AVS and the suspension were modelled and incorporated into a simulation of the laboratory test. Error sources were identified and pointing stability sensitivities were determined via simulation. Statistical predictions of laboratory test performance were derived and compared to actual laboratory test results. The predicted mean pointing stability during simulated shuttle disturbances was 1.22 arc seconds; the actual mean laboratory test pointing stability was 1.36 arc seconds. The successful prediction of laboratory test results provides increased confidence in the analytical understanding of the AVS magnetic bearing technology and allows confident prediction of in-flight performance. Computer simulations of ASPS, operating in the shuttle disturbance environment, predict in-flight pointing stability errors less than 0.01 arc seconds.

Source record↗

The Mid-Infrared Spectrometer on the Infrared Telescope in Space (IRTS) mission

The Mid-Infrared Spectrometer (MIRS) is one of the four focal plane instruments on the Infrared Telescope in Space (IRTS) mission. The instrument has been constructed, tested, and calibrated in the laboratory and is presently scheduled to be launched by a Japanese expendable launch vehicle as part of the Space Flyer Unit-1 mission in early 1995. The wavelength coverage of the MIRS ranges from 4.5 to 11.7 microns, with a spectral resolution of 0.23 to 0.36 microns. With the cryogenically cooled optics of the IRTS telescope assembly, the MIRS will be able to make an extremely sensitive survey of both point-source and extended objects over an estimated 10% of the sky.

Roellig, Thomas L.↗

Preliminary Design and Analysis of the GIFTS Instrument Pointing System

The Geosynchronous Imaging Fourier Transform Spectrometer (GIFTS) Instrument is the next generation spectrometer for remote sensing weather satellites. The GIFTS instrument will be used to perform scans of the Earth s atmosphere by assembling a series of field-of- views (FOV) into a larger pattern. Realization of this process is achieved by step scanning the instrument FOV in a contiguous fashion across any desired portion of the visible Earth. A 2.3 arc second pointing stability, with respect to the scanning instrument, must be maintained for the duration of the FOV scan. A star tracker producing attitude data at 100 Hz rate will be used by the autonomous pointing algorithm to precisely track target FOV s on the surface of the Earth. The main objective is to validate the pointing algorithm in the presence of spacecraft disturbances and determine acceptable disturbance limits from expected noise sources. Proof of concept validation of the pointing system algorithm is carried out with a full system simulation developed using Matlab Simulink. Models for the following components function within the full system simulation: inertial reference unit (IRU), attitude control system (ACS), reaction wheels, star tracker, and mirror controller. With the spacecraft orbital position and attitude maintained to within specified limits the pointing algorithm receives quaternion, ephemeris, and initialization data that are used to construct the required mirror pointing commands at a 100 Hz rate. This comprehensive simulation will also aid in obtaining a thorough understanding of spacecraft disturbances and other sources of pointing system errors. Parameter sensitivity studies and disturbance analysis will be used to obtain limits of operability for the GIFTS instrument. The culmination of this simulation development and analysis will be used to validate the specified performance requirements outlined for this instrument.

Zomkowski, Paul P.↗

A High Resolution Liquid Xenon Imaging Telescope for 0.3-10 MeV Gamma Ray Astrophysics: Construction and Initial Balloon Flights

The results achieved with a 3.5 liter liquid xenon time projection chamber (LXe-TPC) prototype during the first year include: the efficiency of detecting the primary scintillation light for event triggering has been measured to be higher than 85%; the charge response has been measured to be stable to within 0.1% for a period of time of about 30 hours; the electron lifetime has been measured to be in excess of 1.3 ms; the energy resolution has been measured to be consistent with previous results obtained with small volume chambers; X-Y gamma ray imaging has been demonstrated with a nondestructive orthogonal wires readout; Monte Carlo simulation results on detection efficiency, expected background count rate at balloon altitude, background reduction algorithms, telescope response to point-like and diffuse sources, and polarization sensitivity calculations; and work on a 10 liter LXe-TPC prototype and gas purification/recovery system.

Aprile, Elena↗