Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “plug”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Strategies for Controlling Plug Loads. A Tool for Reducing Plug Loads in Commercial Buildings

Plug loads are often not considered as part of the energy savings measures in Commercial Buildings; however, they can account for up to 50% of the energy used in the building. These loads are numerous and often scattered throughout a building. Some of these loads are purchased by the owner and some designed into the building or the tenant finishes for a space. This document provides a strategy and a tool for minimizing these loads.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The value of plug-in hybrid electric vehicles as grid resources

Here, plug-in hybrid electric vehicles (PHEVs) can become valuable resources for an electric power system by providing vehicle to grid (V2G) services, such as energy storage and ancillary services. We use a unit commitment model of the Texas power system to simulate system operations with different-sized PHEV fleets that do and do not provide V2G services, to estimate the value of those services. We demonstrate that a PHEV fleet can provide benefits to the system, mainly through the provision of ancillary services, reducing the need to reserve conventional generator capacity. Moreover, our analysis shows that PHEV owners are made better off by providing V2G services and we demonstrate that these benefits can reduce the time it takes to recover the higher upfront capital cost of a PHEV when compared to other vehicle types.

33 ADVANCED PROPULSION SYSTEMS↗

A Hierarchical Charging Control of Plug-in Electric Vehicles with Simple Flexibility Model

The demand for plug-in electric vehicles (PEVs) is increasing exponentially, which could have significant effects on the power grid, because charging one PEV is nearly equivalent to adding three houses to the power system. Even though PEVs increase demand on the electric grid, their capability to actively interact with the grid presents excellent opportunities for load management, demand response, and various other grid services. This paper proposes an innovative scheduling and control framework to enable smart PEV charging for grid services while meeting PEV owners’ travel needs. In the proposed framework, each set of electric vehicle supply equipment (EVSE) is equipped with a controller that estimates charging power and energy flexibility based on vehicle characteristics, EVSE power rating, battery energy state, and upcoming trip information. With the charging flexibility model received from each EVSE controller, the central coordinator determines the optimal power allocation for a look-ahead time window for the given grid services. The proposed charging coordination strategy can help reduce the computational complexity and communication requirement compared with existing methods. It is also scalable to the expanding PEV fleet and robust to uncertainties in upcoming vehicle trips and future system condition. The proposed method is studied using a prototypical feeder developed at Pacific Northwest National Laboratory and detailed trip information extracted from the National Household Travel Survey.

Wu, Di↗

Pilot-Scale Continuous Plug-Flow Hydrothermal Liquefaction of Food Waste for Biocrude Production

Pilot-scale hydrothermal liquefaction (HTL) of biowaste is a critical step toward commercialization of the HTL technology. Despite many HTL studies conducted with wet biomass, including food waste, few were performed with a pilot-scale continuous plug-flow reactor (PFR), with the biocrude yield and quality analysis based on dewatering (ASTM D2892 Annex X1). This paper describes the development and performance evaluation of a mobile pilot-scale HTL continuous PFR, with a processing capacity of 60 L/h of wet feedstock and 6 L/h of biocrude production. The reactor system was designed for reaction conditions of up to 325 °C and 17.25 MPa. The reactor has a volume of 28.88 L with an additional counterflow heat exchanger volume of 18.07 L. Two types of food wastes, from a food processing plant and grocery store, were processed at 280 °C for 30 min, producing biocrude oil yields of 52.19 and 47.06 wt %, energy recoveries of 68.17 and 70.77%, and carbon recoveries of 66.91 and 64.78%, respectively. Furthermore, due to its high feedstock capacity and reaction volume, large amounts of biocrude oil and post-HTL wastewater (PHW) were obtained from this pilot-scale reactor to allow downstream research on upgrading biocrude oil for transportation fuel as well as PHW treatment and nutrient recovery.

09 BIOMASS FUELS↗

Optimal control of a repowered vehicle: Plug-in fuel cell against plug-in hybrid electric powertrain

This paper describes two different powertrain configurations for the repowering of a conventional vehicle, equipped with an internal combustion engine (ICE). A model of a mid-sized ICE-vehicle is realized and then modified to model both a parallel plug-in hybrid electric powertrain and a proton electrolyte membrane (PEM) fuel cell (FC) hybrid powertrain. The vehicle behavior under the application of an optimal control algorithm for the energy management is analyzed for the different scenarios and results are compared.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Preparation and Characterization of Chemical Plugs Based on Selected Hanford Waste Simulants

This report presents the results of preparation and characterization of chemical plugs based on selected Hanford Site waste simulants. Included are the results of chemical plug bench testing conducted in support of the M1/M6 Flow Loop Chemical Plugging/Unplugging Test (TP-RPP-WTP-495 Rev A). These results support the proposed plug simulants for the chemical plugging/ unplugging tests. Based on the available simulant data, a set of simulants was identified that would likely result in chemical plugs. The three types of chemical plugs that were generated and tested in this task consisted of: 1. Aluminum hydroxide (NAH), 2. Sodium aluminosilicate (NAS), and 3. Sodium aluminum phosphate (NAP). While both solvents, namely 2 molar (2 M) nitric acid (HNO3) and 2 M sodium hydroxide (NaOH) at 60°C, used in these tests were effective in dissolving the chemical plugs, the 2 M nitric acid was significantly more effective in dissolving the NAH and NAS plugs. The caustic was only slightly more effecting at dissolving the NAP plug. In the bench-scale dissolution tests, hot (60°C) 2 M nitric acid was the most effective solvent in that it completely dissolved both NAH and NAS chemical plugs much faster (1.5 – 2 x) than 2 M sodium hydroxide. So unless there are operational benefits for the use of caustic verses nitric acid, 2 M nitric acid heated to 60°C C should be the solvent of choice for dissolving these chemical plugs. Flow-loop testing was planned to identify a combination of parameters such as pressure, flush solution, composition, and temperature that would effectively dissolve and flush each type of chemical plug from preformed chemical plugs in 3-inch-diameter and 4-feet-long pipe sections. However, based on a review of the results of the bench-top tests and technical discussions, the Waste Treatment Plant (WTP) Research and Technology (R&T), Engineering and Mechanical Systems (EMS), and Operations concluded that flow-loop testing of the chemically plugged pipe sections would not provide any additional information or useful data. The decision was communicated through a Sub Contract Change Notice (SCN-070) that included a revised scope as follows: • Photographing the chemical plugs in the pipes before extrusion to compare the morphology of aged gels with that of fresh gels. • Setting up an extrusion apparatus and extruding the chemical plugs. • Documenting the qualitative observations on the efforts to remove the chemical plug materials from the pipe sections. • Performing X-ray diffraction (XRD) analysis of extruded gel samples to detect any crystallization of gel during storage. • Disposing of the extruded gel as a waste. • Documenting the analytical results in a test report. There were no significant morphological differences between the fresh and aged plugs except for an overgrowth of small transparent crystals on the surface of the aged NAS gel plug. An initial pressure of <150 psi was required to start extruding the aged NAS and NAP plugs, whereas the NAH plug began to extrude with the application of minimal pressure. The shear strength of extruded samples ranged from ~9 to >15 KPa for the NAS plug and from ~2 to 6 KPa for the NAH plug. Following extrusion, the NAP plug sections were thixotropic. The bulk of all the aged gel plugs consisted of amorphous material with nitratine constituting the crystalline phase. A separate question about the whether the current in-tank waste conditions will bound the future multi-tank blended feed conditions for the Waste Treatment Plant is outside the scope of this study.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

ZIPPER: Zonal isolation with plug and perf in enhanced reservoirs (Final Technical Report)

Modern multistage hydraulic stimulation treatments in cased wellbores require an effective method of isolating stages between treatments. A commonly used method in the oil and gas industry, plug and perf, is not currently viable for Enhanced Geothermal Systems (EGS) due to limitations of a critical component of the system – the ball drop (flow through) frac plug. Commercially available ball drop frac plugs do not meet the temperature or wellbore diameter requirements needed for use in EGS stimulations. For example, one particular drillable bridge and frac plug line from a large tool developer is only rated to 175 °C, while another is only available up to casing sizes of 5 ½” and rated up to 204 °C. We developed, prototyped, and field tested an upgraded ball drop frac plug to meet the requirements of EGS stimulations, including high-temperature (225+ °C), differential pressure (6000+ psi), and wellbore diameters ranging from 6 5/8” to 10 5/8”. We focused on designs and materials to optimize drillability, a key cost driver in plug and perf systems. The primary objective was to upgrade a drillable frac plug (currently rated to a temperature of 175°C and a pressure of 10,000 psi in 7” casing) to withstand temperatures of 225+°C. The upgraded frac plug was tested in the laboratory as well as in a field trial at a geothermal field. Engineering design and fabrication of the new plug was completed in 2019. Lab testing, validation, and qualification of the plug was completed in 2020. Ultimately the plug was successfully run during a multistage stimulation treatment in a fully horizontal EGS well in 2022. Prior to this project, a ball-drop, flow-through stimulation plug had never been used in a geothermal well. At the conclusion of this project, three different types of zonal isolation plugs were evaluated under full-scale operating conditions across 16 stimulation treatment stages in a first-of-a-kind EGS project called Project Red. This trial included the newly designed high-temperature, large-diameter plug. The plugs met all of 5 the technical requirements for commercial viability. Project Red has since been fully commissioned and is generating electricity on the Nevada grid - the first EGS project to successfully deliver power to the grid in the US.

15 GEOTHERMAL ENERGY↗

Methodology for Mechanical Property Testing on Fuel Cladding Using an Expanded Plug Wedge Test

To determine the tensile properties of irradiated fuel cladding in a hot cell, a simple test was developed at ORNL and is described fully in US Patent Application 20060070455, Expanded plug method for developing circumferential mechanical properties of tubular materials. This method is designed for testing fuel rod cladding ductility in a hot cell utilizing an expandable plug to stretch a small ring of irradiated cladding material. The specimen strain is determined using the measured diametrical expansion of the ring. This method removes many complexities associated with specimen preparation and testing. The advantages are the simplicity of measuring the test component assembly in the hot cell and the direct measurement of specimen strain. It was also found that cladding strength could be determined from the test results. The basic approach of this test method is to apply an axial compressive load to a cylindrical plug of polyurethane (or other materials) fitted inside a short ring of the test material to achieve radial expansion of the specimen. The diameter increase of the specimen is used to calculate the circumferential strain accrued during the test. The other two basic measurements are total applied load and amount of plug compression (extension). A simple procedure is used to convert the load circumferential strain data from the ring tests into material pseudo-stress-strain curves. However, several deficiencies exist in this expanded-plug loading ring test, which will impact accuracy of test results and introduce potential shear failure of the specimen due to inherited large axial compressive stress from the expansion plug test. First of all, the highly non-uniform stress and strain distribution resulted in the gage section of the clad. To ensure reliable testing and test repeatability, the potential for highly non-uniform stress distribution or displacement/strain deformation has to be eliminated at the gage section of the specimen. Second, significant compressive stresses were induced by clad bending deformation due to a clad bulging effect (or the barreling effect). The barreling effect caused very large localized shear stress in the clad and left testing material at a high risk of shear failure. The above combined effects will result in highly non-conservative predictions both in strength and ductility of the tested clad, and the associated mechanical properties as well. To overcome/mitigate the mentioned deficiencies associated with the current expansion plug test, systematic studies have been conducted. Through detailed parameter investigation on specific geometry designs, careful filtering of material for the expansion plug, as well as adding newly designed parts to the testing system, a method to reconcile the potential non-conservatism embedded in the expansion plug test system has been discovered. A modified expansion plug testing protocol has been developed based on the method. In order to closely resemble thin-wall theory, a general procedure was also developed to determine the hoop stress $\sigma_\theta$ in the tested ring specimen. A scaling factor called $\chi$-factor is defined to correlate the ring load F ring into hoop stress $\sigma_\theta$, and written as $\sigma_\theta = \chi \frac{F_{ring}} {tl}$. The generated stress-strain curve agrees very well with tensile test data in both the elastic and plastic regions.

expansion plug test↗

Characterizing Plug Load Energy Use and Savings Potential in Army Buildings

The Assistant Secretary of the Army (Installations, Energy and Environment) tasked the Pacific Northwest National Laboratory to examine plug loads in typical Army buildings. Plug loads (also known as miscellaneous electric loads (MELs)) represent the electricity used by appliances and devices that are plugged in or hardwired and serve functions outside of a building’s core end uses. Common plug loads include computers, printers, copiers, networking devices, refrigerators, and vending machines. They also include personal electronic devices such as televisions, smart phones, tablets, and gaming systems. Examples of hardwired MELs include elevators, air compressors, and fire and security systems. The findings from this study confirm that significant energy is consumed within Army buildings by plug load devices and hardwired MEL equipment. A number of opportunities are identified for reducing unnecessary energy use that could save the Army over $5 million per year when broadly applied. Army regulations clearly spell out expectations for the purchase and operation of information technology equipment (computers, laptops, monitors, printers, and multi-function devices). However, the policies regarding the shutdown or activation of sleep and other lower power modes after 30 minutes of inactivity (15 minutes for monitors) do not appear to be consistently followed. There are many effective approaches and pathways for impacting change as it relates to improving awareness, implementing measures, and adjusting behaviors to identify and reduce plug load energy use. The Army should prioritize and consider deploying all of these to better understand and manage plug load equipment to save energy and enhance resilience across their facilities. Engaging the building occupants who use these devices daily via outreach and education should be a strong component of the strategy. The focus should be on reducing waste without sacrificing productivity or the benefits that many of these devices provide. Continued evaluation of plug loads beyond that performed here is important to gather lessons from additional building and equipment types, and to stay aware of evolving device technology and management options. This will highlight additional needs for policies, best practices, control technologies, and education of personnel to achieve real reductions in energy waste from plug load equipment. It is recommended that this study may serve as the foundation for a broader and sustained focus on plug loads and MELs, towards simultaneously enhancing the productivity, readiness, and resilience of the Army while reducing energy use and demand, and freeing up resources to better support the mission.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Resonant acoustic monitoring of damage in plug‐screw feeders

Abstract Plug‐screw feeders are critical in many industrial processes for compressing slurry materials via a rotating plug‐screw feeder. Over time, increasing plug‐screw feeder wear will eventually lead to catastrophic mechanical failure. Early detection of the wear state can prevent unplanned catastrophic failures resulting in operational shut‐downs, costly repairs, and most importantly the health and safety of workers. We present a theoretical basis for a noninvasive, in operando acoustic resonant technique to monitor the wear state of plug‐screw feeders. The technique is based on tracking the resonant acoustic modes of the plug‐screw feeder, which are sensitive to the plug‐screw feeder geometry, material, and operating conditions. We implemented a multivariate polynomial model to estimate the plug‐screw feeder wear state using multiple acoustic resonances by simulating the acoustic resonant modes for two categories of wear (tip and thread damage) that are common in plug‐screw feeders. Fitting multiple resonances to the polynomial model, we demonstrate accurate estimation of the total mass loss, as well as characterization of the type of damage (i.e., tip vs. thread). Current approaches for monitoring plug‐screw feeder wear rely on shutting down the operation and visually inspecting the plug‐screw feeder. The presented acoustic technique offers a noninvasive, in operando measurement approach that mitigates unplanned catastrophic failures. The acoustic resonance technique presented in the paper has a broad range of industrial applications including the Pharmaceutical, Mining, Integrated Biorefineries (IBR), and Additive Manufacturing industries, to name a few.

36 MATERIALS SCIENCE↗