Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “plasma diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Additive Manufacture of Plasma Diagnostic Components Final Report Phase II

There is now a well-established set of plasma diagnostics (see e.g. [3]), but these remain some of the most expensive assemblies in fusion systems since for every system they have to be custom built, and time for diagnostic development can pace the project. Additive manufacturing (AM) has the potential to decrease production cost and significantly lower design time of fusion diagnostic subsystems, which would realize significant cost reduction for standard diagnostics. In some cases, these basic components can be additively manufactured for less than 1/100th costs of conventional manufacturing.In our DOE Phase II SBIR, we examined the impact that AM can have on plasma diagnostic cost by taking 15 separate diagnostics through an engineering design using Conventional Manufacturing (CM) techniques, then optimizing the design to exploit the benefits of AM. The impact of AM techniques on cost is found to be in several areas. First, the cost of materials falls because AM parts can be manufactured with little to no waste, and engineered to use less material than CM. Next, the cost of fabrication falls for AM parts relative to CM since the fabrication time can be computed exactly, and often no post-processing is required for the part to be functional. We find that AM techniques are well suited for plasma diagnostics since typical diagnostic complexity comes at no additional cost. Cooling channels, for example, can be builtin to plasma-facing components at no extra cost. Fabrication costs associated with assembly are lower for AM parts because many components can be combined and printed as monoliths, thereby mitigating the need for alignment or calibration. Finally, the cost of engineering is impacted by exploiting AM design tools that allow standard components to be customized through web-interfaces. Furthermore, we find that concept design costs can be impacted by scripting interfaces for online engineering design tools.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

STS-3/OSS-1 Plasma Diagnostics Package (PDP) measurements of the temperature pressure and plasma

Designed to withstand the thermal extremes of the STS-3 mission through the use of heaters and thermal blankets, the plasma diagnostics package sat on the release/engagement mechanism on the OSS-1 payload pallet without a coldplate and was attached to the RMS for two extended periods. Plots show temperature versus mission elapsed time for two temperature sensors. Pressure in the range of 10 to the -3 power torr and 10 to the -7 power torr, measured 3 inches from the skin of the package is plotted against GMT during the mission. The most distinctive feature of the pressure profile is the modulation at the obit period. It was found that pressure peaks when the atmospheric gas is rammed into the cargo bay. Electric and magnetic noise spectra and time variability due to orbiter systems, UHF and S-band transmitter field strengths, and measurements of the ion spectra obtained both in the cargo bay and during experiments are plotted.

Shawhan, S. D.↗

Investigation of plasma diagnostics using a dual frequency harmonic technique

Plasma diagnostic methods using harmonic currents analysis of electrostatic probes were experimentally investigated to understand the differences in their measurement of the plasma parameters. When dual frequency voltage (ω{sub 1},ω{sub 2}) was applied to a probe, various harmonic currents (ω{sub 1}, 2ω{sub 1},ω{sub 2}, 2ω{sub 2},ω{sub 2}±ω{sub 1},ω{sub 2}±2ω{sub 1}) were generated due to the non-linearity of the probe sheath. The electron temperature can be obtained from the ratio of the two harmonics of the probe currents. According to the combinations of the two harmonics, the sensitivities in the measurement of the electron temperature differed, and this results in a difference of the electron temperature. From experiments and simulation, it is shown that this difference is caused by the systematic and random noise.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Some plasma aspects and plasma diagnostics of ion sources (invited)

We consider plasma properties in the most advanced type of plasma ion sources, electron cyclotron resonance ion sources for highly charged ions. Depending on the operation conditions the plasma in these sources may be highly ionized, which completely changes its transport properties. The most striking difference to weakly ionized plasma is that diffusion will become intrinsically ambipolar. We further discuss means of plasma diagnostics. As noninvasive diagnostic methods we will discuss analysis of the ion beam, optical spectroscopy, and measurement of the x-ray bremsstrahlung continuum. From beam analysis and optical spectroscopy one may deduce ion densities, and electron densities and distribution functions as a mean over the line of sight along the axis (optical spectroscopy) or at the plasma edge (ion beam). From x-ray spectra one obtains information about the population of highly energetic electrons and the energy transfer from the driving electromagnetic waves to the plasma--basic data for plasma modeling.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of laser-aided plasma diagnostics and related technology

Laser-aided plasma diagnostics, aiming for establishment of reliable density measurement in next step magnetically confined fusion devices, are under development at the National Institute for Fusion Science. A new type of two color laser (57.2/47.6-{mu}m CH{sub 3}OD) interferometer has been developed and its original function, vibration subtraction, was confirmed in a test stand. The line integrated density measurements by the polarimeter were demonstrated at Compact Helical System by the Cotton-Mouton polarimeter and at the LHD by the Faraday rotation polarimeter.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High-power terahertz optically pumped NH{sub 3} laser for plasma diagnostics

The parameter of a terahertz (THz) laser intended for plasma diagnostics in electrodynamic accelerators and tokamaks with a strong magnetic field are discussed. Generation of THz radiation in an ammonia laser under the action of high-power pulsed optical pumping by the radiation of a 10P(32) CO{sub 2} laser is simulated numerically. The main characteristics of the output radiation, such as its spectrum, peak intensity, time dependence, and total energy, are calculated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Description of the plasma diagnostics package (PDP) for the OSS-1 Shuttle mission and JSC plasma chamber test in conjunction with the fast pulse electron gun (FPEG)

The objectives, equipment, and techniques for the plasma diagnostics package (PDP) carried by the OSS-1 instrument payload of the STS-4 and scheduled for the Spacelab-2 mission are described. The goals of the first flight were to examine the Orbiter-magnetoplasma interactions by measuring the electric and magnetic field strengths, the ionized particle wakes, and the generated waves. The RMS was employed to lift the unit out of the bay in order to allow characterization of the fields, EM interference, and plasma contamination within 15 m of the Orbiter. The PDP will also be used to examine plasma depletion, chemical reaction rates, waves, and energized plasma produced by firing of the Orbiter thrusters. Operation of the PDP was carried out in the NASA Space Environment Simulation Laboratory test chamber, where the PDP was used to assay the fields, fluxes, wave amplitudes, and particle energy spectra. The PDP instrumentation is also capable of detecting thermal ions, thermal electrons suprathermal particles, VHF/UHF EMI levels, and the S-band field strength.

Shawhan, S. D.↗

Polarizer design for millimeter-wave plasma diagnostics

Radiation from magnetized plasmas is in general elliptically polarized. In order to convert the elliptical polarization to linear polarization, mirrors with grooved surfaces are currently employed in our collective Thomson scattering diagnostic at ASDEX Upgrade. If these mirrors can be substituted by birefringent windows, the microwave receivers can be designed to be more compact at lower cost. Sapphire windows (a-cut) as well as grooved high density polyethylene windows can serve this purpose. The sapphire window can be designed such that the calculated transmission of the wave energy is better than 99%, and that of the high density polyethylene can be better than 97%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

PLASMA DIAGNOSTIC POTENTIAL OF 2p4f IN N{sup +}—ACCURATE WAVELENGTHS AND OSCILLATOR STRENGTHS

Radiative emission lines from nitrogen and its ions are often observed in nebula spectra, where the N{sup 2+} abundance can be inferred from lines of the 2p4f configuration. In addition, intensity ratios between lines of the 2p3p-2p3s and 2p4f-2p3d transition arrays can serve as temperature diagnostics. To aid abundance determinations and plasma diagnostics, wavelengths and oscillator strengths were calculated with high precision for electric dipole (E1) transitions from levels in the 2p4f configuration of N{sup +}. Electron correlation and relativistic effects, including the Breit interaction, were systematically taken into account within the framework of the multiconfiguration Dirac-Hartree-Fock method. Except for the 2p4f-2p4d transitions with quite large wavelengths and the two-electron-one-photon 2p4f-2s2p {sup 3} transitions, the uncertainties of the present calculations were controlled to within 3% and 5% for wavelengths and oscillator strengths, respectively. We also compared our results with other theoretical and experimental values when available. Discrepancies were found between our calculations and previous calculations due to the neglect of relativistic effects in the latter.

79 ASTRONOMY AND ASTROPHYSICS↗

Polarization-separated double-imaging spectroscopy for weakly-ionized plasma diagnostics

Laser Thomson scattering, which provides thermal properties of electrons, has been extensively utilized in plasma diagnostics. However, being a non-resonant linear light scattering technique, it often encounters several challenges in weakly-ionized plasma diagnostics due to spectral overlap with different scatterings induced from other existing species, including Mie, Rayleigh, and rotational Raman scatterings. To address this challenge, we propose an imaging spectroscopy technique, polarization-separated double-imaging spectroscopy (PoDIS), which selectively separates specific scatterings based on their polarization characteristics. Using an atmospheric plasma jet as a plasma source for demonstration, we show that PoDIS can effectively separate rotational Raman and Thomson scatterings from a superimposed spectrum without prior knowledge or assumptions about the thermal properties of neutrals or electrons. This separation enables independent fitting of the rotational Raman and Thomson scattering spectra, allowing for precise determination of the thermal properties of neutral particles and electrons separately.

Bak, Junhwi [Texas A&M University, College Station↗

In situ plasma diagnostics study of a commercial high-power hollow cathode magnetron deposition tool

Using a newly designed and built plasma diagnostic system, the plasma parameters were investigated on a commercial 200 mm high-power hollow cathode magnetron (HCM) physical vapor deposition tool using Ta target under argon plasma. A three dimensional (3D) scanning radio frequency (rf)-compensated Langmuir probe was constructed to measure the spatial distribution of the electron temperature (T{sub e}) and electron density (n{sub e}) in the substrate region of the HCM tool at various input powers (2-15 kW) and pressures (10-70 mTorr). The T{sub e} was in the range of 1-3 eV, scaling with decreasing power and decreasing pressure. Meanwhile, n{sub e} was in the range of 4x10{sup 10}-1x10{sup 12} cm{sup -3} scaling with increasing power and decreasing pressure. As metal deposits on the probe during the probe measurements, a self-cleaning plasma cup was designed and installed in the chamber to clean the tungsten probe tip. However, its effectiveness in recovering the measured plasma parameters was hindered by the metal layer deposited on the insulating probe tube which was accounted for the variation in the plasma measurements. Using a quartz crystal microbalance combined with electrostatic filters, the ionization fraction of the metal flux was measured at various input power of 2-16 kW and pressure of 5-40 mTorr. The metal ionization fraction reduced significantly with the increasing input power and decreasing gas pressure which were attributed to the corresponding variation in the ionization cross section and the residence time of the sputtered atoms in the plasma, respectively. Both the metal neutral and ion flux increased at higher power and lower pressure. The 3D measurements further showed that the ionization fraction decreased when moving up from the substrate to the cathode.

74 ATOMIC AND MOLECULAR PHYSICS↗

Low temperature plasma diagnostics with tunable synchrotron vacuum ultraviolet photoionization mass spectrometry

Plasma-based technology is of great importance for a range of industrial applications. However, due to the complexity of gas-phase and surface chemical reactions, the underlying plasma chemistry is still poorly understood, leading to a growing demand for experimental setups on plasma diagnostics. In this paper, we report an apparatus that combines tunable synchrotron vacuum ultraviolet (VUV) photoionization with molecular-beam mass spectrometry for detecting ionic and neutral species formed in the processes of plasma discharge. The products including reactive intermediates such as enols can be identified unambiguously with the measurements of photoionization mass spectrometry (PIMS) and photoionization efficiency spectra. The tunable VUV PIMS has been proven as an ideal and sensitive tool for a comprehensive understanding of plasma chemistry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A comparative study of electrical probe techniques for plasma diagnostics

Techniques for using electrical probes for plasma diagnostics are reviewed. Specific consideration is given to the simple Langmuir probe, the symmetric double probe of Johnson and Malter, the variable-area probe of Fetz and Oeschsner, and a floating probe technique. The advantages and disadvantages of each technique are discussed.

Szuszczewicz, E. P.↗

Millimeter-wave system-on-chip advancement for fusion plasma diagnostics

Recent advances in radio-frequency system-on-chip technology have provided mm-wave fusion plasma diagnostics with the capability to overcome major challenges such as space inefficiency, inflexible installation, sensitivity, susceptibility to EMI, and prohibitively high cost of conventional discrete component assemblies as higher imaging resolution and data accuracy are achieved by increasing the number of channels. Nowadays, shrinking transistor gate lengths on fabrication techniques have enabled hundreds of GHz operation, which is suitable for millimeter-wave diagnostics on current and future tokamaks. The Davis Millimeter Wave Research Center (DMRC) has successfully developed V-band (55-75 GHz) transmitter and receiver chips for Microwave Imaging Reflectometer (MIR) instruments. The transmitter can illuminate 8 different frequencies simultaneously within 55-75 GHz. Moreover, the receiver has the capability to amplify the reflected signal (>30 dB) while offering 10-30× reduction in noise temperature compared to current MIR instruments. Plasma diagnostics requires ultra-wideband (more than 20 GHz) operation which is approximately nine times wider bandwidth than the recent commercial impetus for communication systems. Current efforts are underway for gallium-arsenide monolithic microwave integrated circuit receiver chips at W-band (75-110 GHz) and F-band (90–140 GHz) permitting measurements at higher toroidal magnetic fields.

47 OTHER INSTRUMENTATION↗

THz time-domain spectroscopy for tokamak plasma diagnostics

The technology is now becoming mature for diagnostics using large portions of the electromagnetic spectrum simultaneously, in the form of THz pulses. THz radiation-based techniques have become feasible for a variety of applications, e.g., spectroscopy, imaging for security, medicine and pharmaceutical industry. In particular, time-domain spectroscopy (TDS) is now being used also for plasma diagnostics in various fields of application. This technique is promising also for plasmas for fusion applications, where plasma characteristics are non-uniform and/or evolve during the discharge This is because THz pulses produced with femtosecond mode-locked lasers conveniently span the spectrum above and below the plasma frequency and, thus, can be used as very sensitive and versatile probes of widely varying plasma parameters. The short pulse duration permits time resolving plasma characteristics while the large frequency span permits a large dynamic range. The focus of this work is to present preliminary experimental and simulation results demonstrating that THz TDS can be realistically adapted as a versatile tokamak plasma diagnostic technique.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Experience On Plasma Diagnostics On JET

This year marks the 30th anniversary of the decision on 17 October 1977 by the European Council of Ministers to proceed with the JET project. Very little thought had been given to the diagnostic requirements during the design phase--indeed many people assumed that JET would not do detailed physics studies and would need only a few basic diagnostics. Of course this view turned out to be incorrect--JET needed a comprehensive set of diagnostics and has conducted a very extensive physics programme. The large physical dimensions of JET, the radiation environment and the stringent interface standards radically changed our concept of diagnostics compared to the smaller fusion experiments that had gone before. In this paper I will review some of the experience on burning plasma diagnostics on JET.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗