Performance Testing of a Moving-Bed Gasifier Using Coal, Biomass, and Waste Plastic Blends to Generate White Hydrogen

The objective of this DOE-funded project by the Electric Power Research Institute, Inc. (EPRI), Hamilton Maurer International (HMI) and Sotacarbo S.p.A. (Sotacarbo), is to qualify coal, biomass, and plastic waste blends based on performance testing of selected pellet recipes in a pilot-scale updraft moving-bed gasifier. The testing provides relevant data to advance the commercial-scale design of the moving-bed gasifier to be able to successfully use these feedstocks to produce hydrogen. In particular, the effects of the waste plastics on feedstock development (i.e., blending and pelletizing) and the resulting products (i.e., syngas compositions, organic condensate production, and ash characteristics) are a focus. The gasifier is Hamilton Mauer International, Inc. (HMI)’s moving-bed gasifier, which has been proven capable of gasifying nearly all coal ranks. It has also shown the ability in prior testing work to gasify wood chips. However, mixtures of these fuels with plastic wastes had not yet been prepared and gasified together. The feedstocks were prepared by California Pellet Mill (CPM) under contract to HMI.

01 COAL, LIGNITE, AND PEAT↗

Annual Performance Testing of Tracer Gas and Tracer Aerosol Detectors for use in Radionuclide NESHAP Compliance Testing

Los Alamos National Laboratory’s (LANL’s) compliance with Radionuclide NESHAP 1 regulations is managed by the Radionuclide Air Emissions Management (RAEM) team, part of LANL’s Compliance Programs group (EPC-CP). One area of the Radionuclide NESHAP addresses requirements for siting a stack sample system. This memo documents the most recent performance tests of the sulfur hexafluoride detectors for use in stack gas mixing tests, as well as the functional trending test on a pair of optical particle counters, comparing results from a non-calibrated instrument to a calibrated instrument.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Washington Clean Energy Fund: Energy Storage System Consolidated Performance Test Results

This report provides an overview of test results for four energy storage systems funded under the Washington Clean Energy Fund deployed at three utilities in Washington State. Integration of energy storage into the U.S. grid has been gathering momentum across the industry, especially as penetration of power generated by renewable resources increases. Several states have storage procurement targets to deal with a variety of issues, such as afternoon total system load ramping requirements, frequency regulation/control, and integration power generated from by renewable resources. This report presents the performance test results for battery energy storage systems (BESS) funded by the Washington Clean Energy Fund (CEF) 1 Program ($\$$14.3 million in state funding supporting a total investment of $\$$43 million). For each project, the technical attributes of the BESS were tested, defined, and evaluated in detail. These projects were funded jointly by Avista, the Snohomish Public Utility District (SnoPUD), Puget Sound Energy (PSE), the Washington CEF, and the U.S. Department of Energy Office of Electricity Delivery and Energy Reliability (DOE-OE).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Experimental Results of 2-m Heptane, Bakken Crude Oil, and Dilbit Crude Oil Pool Fire Tests Performed for the National Research Council of Canada

This report provides results from a series of 2-m pool fire experiments performed in the Thermal Test Complex at Sandia National Laboratories testing heptane, Bakken crude oil, and dilbit crude oil. The effect of the presence and placement of a calorimeter, fuel supply temperature, and maintaining a constant fuel level were assessed. Measurements include burn rate, surface emissive power, flame height, heat flux to an engulfed calorimeter, heat flux to external instruments, thermocouple temperatures within the fuel and fire plume, and heat release rate. The results indicate that the presence and placement of the calorimeter has the most effect on the measured quantities for the Bakken crude oil and indicated no effect for the Dilbit crude oil. The fuel feed temperature had a slight effect for the heptane fuel, but not for the crude oils. Allowing the fuel to burn down did not have a significant effect on any of the fuels. The Bakken crude oil resulted in the highest average total heat flux to the calorimeter by a factor of about 1.5 and 1.3 higher compared to heptane and the dilbit crude oil, respectively.

02 PETROLEUM↗

Summary report on the mechanical testing performed at INL for creep rupture, fatigue, creep-fatigue, and aging of A709 base material

The report provides the status of the creep, fatigue, and creep-fatigue testing to conducted at Idaho National Laboratory to generate a data package to support Alloy 709 qualification in American Society of Mechanical Engineers, Boiler and Pressure Vessel Code, Section III, Division 5. These tests were performed on three commercial heats of plate material. The first procured heat was manufactured by G.O. Carlson with heat number 58776. Second and third heats were fabricated by ATI Specialty Rolled Products, with heat numbers 529900 and 530843, respectively. A series of creep and cyclic specimens were fabricated from these three heats, and tests were performed. This report presents a master list of all completed and ongoing creep, fatigue, and creep fatigue tests. Cyclic properties of three commercial heats are compared. Thermal aging of three commercial heats for 3000 hours were completed in FY 2025. The thermal aging campaign to age plate material from three commercial heats up to 100,000 hours is ongoing.

36 - MATERIALS SCIENCE↗

High Solids Performance Testing in a Scaled TSCR System

The Tank Side Cesium Removal (TSCR) project is a technology demonstration that will pretreat Hanford tank waste supernatant in support of the Direct Feed Low-Activity Waste (DFLAW) mission. The TSCR system employs two key separation technologies: dead-end filtration (DEF) and ion exchange (IX) using crystalline silicotitanate (CST) media. DEF will be used to remove undissolved solids from tank waste to protect the functionality of the IX columns and the IX system will remove Cs-137 from tank waste. The separation technologies (DEF and IX) used in TSCR are technically mature and have also been successfully deployed at the Savannah River site in a similar facility known as the Tank Closure Cesium Removal (TCCR) system. While testing with simulants and real waste has been successfully performed under conditions expected during the initial operation of TSCR, test data is absent for assessing off normal high solids loading that may be in the TSCR waste feed. Normal TSCR treatment operations are expected to handle wastes with solids content on the order of 200 ppm, and off normal solids loading could be much larger than the nominal level. The testing program described in this report was conducted to understand the consequence of operating the TSCR system at elevated solids loadings up to the high-solids limit of 15,000 ppm [i.e., 1.5-wt%] identified in the TSCR design basis. Although the system is not required to make throughput above the nominal solids loading, the testing was intended to provide important information related to potential off normal operations. At off normal levels near the high-solids limit, there are potential implications for TSCR performance in the areas of throughput, DEF pressure drop, filter backflush frequency, and IX column pressure drop. In addition, intrusion of solids into the IX column was postulated to impact the Cs-137 loading behavior by promoting channeling or flow maldistribution in the column; since the magnitude of the postulated effect was unknown, assessing it was also of interest. The testing was performed using representative waste simulants and a prototypic, integrated TSCR system designed and assembled specifically to conduct the high solids performance assessment. Overall, the scaled TSCR testing demonstrated that full-scale unit operations can succeed in fulfilling their processing objectives in the presence of solids up to 3,000 ppm, but there are potential performance challenges to filtration operations at solids loadings as low as ~500 ppm. The severity of the challenge is likely to be dependent on the type and size distribution of solids, of which the current testing only examined a single type and size distribution. To provide some flexibility for future full-scale operations, the results of the testing suggest two possible risk reduction strategies that can be implemented without any changes in TSCR design or configuration. One option would be to enact an administrative limit on the solids loading to protect TSCR from feeds that are likely to require a high DEF swap frequency. Another option is to permit operation of the DEFs at differential pressures greater than 2 psid before swapping filters. The selection of a higher differential pressure target is not anticipated to adversely impact DEF backflushing efficacy and would reduce both swap frequency and the amount of waste sent to AP-108.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Building fault detection data to aid diagnostic algorithm creation and performance testing

It is estimated that approximately 4-5% of national energy consumption can be saved through corrections to existing commercial building controls infrastructure and resulting improvements to efficiency. Correspondingly, automated fault detection and diagnostics (FDD) algorithms are designed to identify the presence of operational faults and their root causes. A diversity of techniques is used for FDD spanning physical models, black box, and rule-based approaches. A persistent challenge has been the lack of common datasets and test methods to benchmark their performance accuracy. This article presents a first of its kind public dataset with ground-truth data on the presence and absence of building faults. This dataset spans a range of seasons and operational conditions and encompasses multiple building system types. It contains information on fault severity, as well as data points reflective of the measurements in building control systems that FDD algorithms typically have access to. The data were created using simulation models as well as experimental test facilities, and will be expanded over time.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance Testing of Enhanced Linear Variable Integrated Sensor (ELVIS III) for LVDTs

The Enhanced Linear Variable Intrinsic Sensor (ELVIS) was a 2024 breakthrough discovery by Idaho National Laboratory (INL) in terms of further innovating the usage of all linear variable differential transformers (LVDTs) and enhancing their performance in harsh environments. In irradiation tests conducted within material test reactors (MTRs), LVDTs with an internal temperature sensing capability can address several critical challenges. This report focuses on performance testing of the ELVIS III device with new hybrid LVDTs provided by the Institute for Energy Technology (IFE), which is the world’s sole supplier of nuclear-grade LVDTs. The ELVIS III device was evaluated in terms of temperature showcasing promising results comparable to a typical type-K thermocouple (TC).

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Comparison of Model Predictions and Performance Test Data for a Prototype Thermal Energy Storage Module

Although model predictions of thermal energy storage (TES) performance have been explored in previous investigations, relevant test data that enable experimental validation of performance models have been limited. This is particularly true for high-performance TES designs that facilitate fast input and extraction of energy. In this paper, we present a summary of experimental tests of a high-performance TES unit using lithium nitrate trihydrate phase change material as a storage medium. Performance data are presented for complete dual-mode cycles consisting of extraction (melting) followed by charging (freezing). These tests simulate the cyclic operation of a TES unit for asynchronous cooling in a variety of applications. Finally, the model analysis is found to agree reasonably well, within 10%, with the experimental data except for conditions very near the initiation of freezing, a consequence of subcooling that is required to initiate solidification.

25 ENERGY STORAGE↗

AN OVERVIEW OF THE DESIGN AND PERFORMANCE TESTING OF A 275 BAR INTEGRALLY GEARED SUPERCRITICAL CO2 COMPRESSOR FOR POWER GENERATION

An integrally geared compressor-expander (compander) for supercritical CO2 (sCO2) was developed to convert thermal energy to electricity. With operating pressures of 275 bar, this turbomachine represents the state of the art in integrally geared machine architecture, hitting compressor inlet densities of 600 kg/m3 and discharge pressures of 275 bar. The product development was funded by the Department of Energy’s Energy Efficiency and Renewable Energy Office under EE0007114 to advance the state of the art in concentrated solar power applications; however, the technology itself is agnostic to heat source, and is predicted to achieve a thermal-to-electric conversion efficiency of 50% for any indirect heat source capable of providing turbine inlet temperatures of 700°C or greater. While the program encompassed the design and testing for the compressor and turbine elements, this paper will focus on the compressor design and operation. The paper will begin with an introduction to the cycle design and analysis of an indirectly heated integrally geared sCO2 compander, a discussion of the mechanical and aerodynamic design of the compressor that is a two stage radial compressor operating subcritically at 27,512 rpm, and will then proceed to describe the test facility and measured data to characterize the performance and robustness of the machine. The paper will conclude with a discussion on lessons learned throughout the course of commissioning and testing. Practical aspects of testing a compressor operating near the dome including complications relating to obtaining an accurate compressor flow map, efficiency calculations, flow unsteadiness, and associated measurement uncertainties will be discussed.

wilkes, jason↗

Motorette Thermal Performance Testing and Modeling for an Electric Motor with Additively Manufactured Hollow Conductors with Integrated Heat Pipes

This paper discusses the design, build and test of a motorette to characterize the thermal performance of an additively manufactured coil integrated with heat pipes. The motorette is powered using a variable frequency AC power supply and cooled through two independent cooling systems. The first cooling system cools the stator core using forced convection of air flowing over a finned heat sink mounted on the stator outer diameter. The second cooling system cools the heat pipes using forced convection of 50-50 water ethylene glycol (WEG) mixture flowing through condenser chambers. A 3D thermal FEA model of the setup is built and heat transfer coefficients (HTC) of convective boundaries are computed using coolant flow rates from test data and empirical equations. Temperature at locations on the coil and heat sink are recorded and compared to thermal model predicted values. A maximum temperature error of 22.7% occurs at 180ARMS and 800 Hz operating point for the AM dual coil. The thermal model provides higher temperatures compared to test results and hence it is on the conservative side but in general, there is good correlation between test and model results. Lastly, opportunities for improvement to both test data measurement and 3D thermal FEA modeling are discussed.

additive manufacturing↗

Cooling Performance Testing of Attaway's Negative Pressure CDU

Attaway is a recently installed High-Performance Computing (HPC) machine at Sandia National Labs that is 70% water-cooled and 30% air-cooled. This machine, supplied by Penguin Computing, uses a novel new cooling system from Chilldyne that operates in a vacuum, preventing water leaks. If water-cooling is to fail, fans inside of each node will ramp up to do 100% of the cooling on Attaway. Various tests were completed on Attaway to determine the robustness of its cooling system as well as its ability to respond to sudden changes in states. These changes include an immediate change from an idle compute load to full load (Linpack) as well as running Linpack without any water cooling from Attaway's CDUs. It was discovered that Attaway could respond to sudden compute load changes very well, never throttling any nodes. When Linpack was run without water cooling, the system was able to operate for a short time before throttling happened.

42 ENGINEERING↗

Novel Full-Ceramic Multi-Tubular Membrane Systems for Pre-Combustion CO2 Capture with Simultaneous H2 Production: Fabrication, Performance Testing, and 3D CFD Modeling

Inorganic membranes show promise for application in pre-combustion CO2 capture with simultaneous H2 production. State-of-the-art systems for use under high temperature and pressure conditions consist of multiple membrane tube bundles prepared in a "candle-filter" configuration, in which the membrane tubes are open at one end and sealed at the other. This configuration is used for practical reasons, specifically the need to minimize potential problems due to thermal expansion mismatch, at high temperatures, between the ceramic tube bundle and the steel housing. The primary technical problem with the candle-filter configuration for use in commercial-scale installations is the inability to purge the permeate side (typically the tube side), a feature that is crucial for high H2 recovery. In this study, we fabricated dual-end open, commercial-size ceramic multiple-tube bundles made of zeolite, palladium (Pd), and carbon molecular sieve (CMS) membranes that enable permeate-side (tube-side) purge for gas separation applications. Experimental gas separation data with these membrane bundles under harsh operating conditions (temperatures up to 350 and pressures up to 800 psig), to be presented at the meeting, manifest excellent performance. Parallel to the membrane bundle construction and testing efforts, we have also developed a detailed 3D CFD modeling package using COMSOL Multiphysics software to gain more insight into the effect on the H2 purity and recovery of the detailed geometry of the multi-tubular membrane system, including the number of tubes used, their dimensions, and placement in the bundle, as well as the number, type, and positioning of internal baffles and other flow-enhancement accessories. The CFD package is validated with experimental data from different systems (1-tube, 3-tube, and 19-tube bundles), and shows high accuracy in predicting the experimental results (<5 % error in all cases). The results of our study show that the detailed internal geometry of these multi-tubular membrane systems has a considerable impact on the performance of the system as the flow maldistribution within the shell-side can substantially decrease (>40%) the H2 recovery.

20 FOSSIL-FUELED POWER PLANTS↗

Performance testing of the iX Cameras iSpeed 727 high-speed camera

This work evaluated the iX Cameras iSpeed 727, a commercial CMOS-based continuous- recording high-speed camera. Various parameters of importance in the scheme of accurate time-resolved measurements and photonic quantification have been measured under controlled conditions on the bench, using state-of-the-art instrumentation. We will detail the procedures and results of the tests laid out to measure sensor sensitivity, linearity, signal-to-noise ratio and image lag. We also looked into the electronic shutter performance and accuracy, as exposure time is of particular interest to high-speed imaging. The results of the tests show that this camera matches or exceeds the performance of competing units in most aspects, but that, as is the case for other high-speed camera systems, corrections are necessary to make full use of the image data from a quantitative perspective.

42 ENGINEERING↗

Beam test performance of AstroPix sensor with 120 GeV protons

AstroPix is a High-Voltage CMOS Monolithic Active Pixel Sensor (HV-CMOS MAPS) developed for precision gamma-ray imaging and spectroscopy in the medium-energy regime, as well as for precise shower imaging and tracking in the Barrel Imaging Calorimeter (BIC) of the Electron Proton/Ion Collider (ePIC) detector at the future Electron–Ion Collider (EIC). We present beam test results of the AstroPix_v3 sensor using a 120 GeV proton beam at the Fermilab Test Beam Facility (FTBF), performed as part of the broader experimental campaign for the BIC prototype calorimeter. The sensor’s 500 µm pixel pitch enabled precise measurement of the beam profile, providing important information for the calorimeter performance studies. Using the measured 120 GeV proton data, we measure the energy deposit of minimum ionizing particles (MIP) and use them to extract the corresponding effective depletion depth at a single bias voltage of −150 V .

AstroPix↗

Analysis of Air-Purifying Respirator (APR) and Powered Air-Purifying Respirator (PAPR) Cartridge Performance Testing on Hanford Tanks BY-108 and BY-110 Volume 1

Washington River Protection Solutions (WRPS) tested four types of chemical cartridges for use in air-purifying respirators (APR) and powered air-purifying respirators (PAPR). These tests were undertaken to determine the period of time that the cartridges would provide adequate performance for APRs and PAPRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPC) from vapors exiting the headspaces of Hanford BY-108 and BY-110 waste storage tanks. The Occupational Safety and Health Administration (OSHA) considers cartridge testing to be a valid approach for establishing cartridge change schedules. Testing commonly is applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate the cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Cartridge tests were conducted over two days from February 23-25, 2018, using headspace vapors from Hanford tanks BY-108 and BY-110. Headspace vapors from the BY-108 tank were fed to the PAPR respirator cartridge test stand, while vapors from the BY-110 headspace were fed to the APR respirator cartridge test stand. Both the APR and PAPR test stands were developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Two different cartridges were assessed on each tank. Multipurpose APR cartridges—SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina)—were assessed for vapors from BY-110 using the APR cartridge test stand. Multipurpose PAPR cartridges—MSA OptiFilter TL (MSA Safety Inc., Pittsburgh, Pennsylvania) and 3M FR-57 (3M Company, Maplewood, Minnesota)—also were assessed for vapors from BY-108 over the same two days using the PAPR cartridge test stand. Sample media (i.e., sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridges, and the samples then were analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life. The key conclusions from the analysis are described below.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Air-Purifying Respirator (APR) Cartridge Performance Testing on Hanford Tanks SX-101 and SX-104: Volume 2 - Raw Analytical Data

As the Tank Operations Contractor for U.S. Department of Energy operations at the Hanford site in Washington State, Washington River Protection Solutions (WRPS) is responsible for managing highly radioactive wastes stored in tanks at Hanford. To protect workers at Hanford Tank Farms, WRPS tests air-purifying respirator (APR) and powered air-purifying respirator (PAPR) chemical cartridges commonly used at the tank farms. The tests were conducted to determine the period of time the cartridges would provide adequate performance for APRs and PAPRs when workers are exposed to a mixture of Chemicals of Potential Concern (COPC) from any vapors exiting headspaces in the storage tanks. Occupational Safety and Health Administration (OSHA) Standard 29 Code of the Federal Regulations (CFR) 1910.134(d)(3)(iii)(b)(2) specifies that for protection against gases and vapors, employers shall implement a schedule for cartridges to ensure that change-outs occur before the end of service life. The change schedule can be based on objective information or data that ensures cartridge change-outs occur before the end of their service life. The primary function of the WRPS Cartridge Test Program is to obtain objective data to determine service lives for the APR and PAPR cartridges used at Hanford Tank Farms. WRPS contracted with Pacific Northwest National Laboratory to analyze the test data and offer an independent analysis and any recommendations. This report summarizes data analysis of APR cartridge testing on headspace vapors from Hanford SX-101 and SX-104 single-shell tanks. Volume 1 of this report documents the testing, data analysis, results, conclusions, and recommendations resulting from the APR testing on SX-101 and SX-104 headspace vapors. Volume 2 provides an introduction to the raw data, including analytical laboratory analysis results that supported the analysis and conclusions documented in Volume 1.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Air-Purifying Respirator (APR) and Powered Air-Purifying Respirator (PAPR) Cartridge Performance Testing on a Hanford AX Tank Farm Exhauster Slipstream Volume 2: Raw Analytical Data

As the Tank Operations Contractor for U.S. Department of Energy operations at the Hanford site in Washington State, Washington River Protection Solutions (WRPS) is responsible for managing highly radioactive wastes stored in tanks at Hanford. To protect workers at Hanford Tank Farms, WRPS tests air-purifying respirator (APR) and powered air-purifying respirator (PAPR) chemical cartridges commonly used at the tank farms. The tests were conducted to determine the period of time the cartridges would provide adequate performance for APRs and PAPRs when workers are exposed to a mixture of Chemicals of Potential Concern (COPC) from any vapors exiting headspaces in the storage tanks. Occupational Safety and Health Administration (OSHA) Standard 29 Code of the Federal Regulations (CFR) 1910.134(d)(3)(iii)(b)(2) specifies that for protection against gases and vapors, employers shall implement a schedule for cartridges to ensure that change-outs occur before the end of service life. The change schedule can be based on objective information or data that ensures cartridge change-outs occur before the end of their service life. The primary function of the WRPS Cartridge Test Program is to obtain objective data to determine service lives for the APR and PAPR cartridges used at Hanford Tank Farms. WRPS contracted with Pacific Northwest National Laboratory to analyze the test data and offer an independent analysis and any recommendations. This report summarizes data analysis of APR and PAPR cartridge testing on a vapor slipstream from the Hanford AX tank farm exhauster. Volume 1 of this report documents the testing, data analysis, results, conclusions, and recommendations resulting from the cartridge testing on AX exhauster slipstream vapors. Volume 2 provides an introduction to the raw data, including analytical laboratory analysis results that supported the analysis and conclusions documented in Volume 1.