PV Fleet Performance Data Initiative 2026 Update

We provide an update on the PV Fleet Performance Data Initiative at the 2026 PV Reliability Workshop. Our latest runs incorporate additional data sources and an integrated analysis pipeline run on our Kestrel HPC cluster. Initial degradation findings suggest that single-axis tracked PV systems exhibit higher performance loss rates than fixed-tilt systems, an increase of 0.5 %/yr, almost double. We discuss multiple methods for identifying stuck tracker rows, which are suspected to be a contributor to the enhanced degradation. Through satellite image detection and data-driven approaches we address the topic of identifying when stuck trackers are occuring and to what extent the problem exists. Preliminary results suggest that the increased performance loss detected for the tracked systems would be consistent with stuck tracker rows affecting on the order of 5% - 10% of the system.

14 SOLAR ENERGY↗

PV Fleet Performance Data Initiative (March 2020 Methodology Report)

Data for thousands of systems by multiple sources were transmitted to NREL for evaluation. Initial automated data quality assurance (QA) checks identified hundreds of systems (QA Tier 1) with high-quality meteorological and AC production data and hundreds of QA Tier 2 systems with adequate data quality. A standard RdTools analysis was conducted for these systems, evaluating performance loss on an annualized basis. To date with the systems evaluated so far, we find a median performance loss rate (aka Rd or degradation rates) for the entire fleet of -0.72%/year based on individual inverter data, which is in line with historical degradation rates previously published for modules and systems (-0.5% to -0.9% / yr, Jordan et al. 2016). A fleet-scale distribution based on revenue-grade meter data rather than inverter AC (alternating current) data yields a slightly different result. We are working to understand the difference between this result and the inverter-based result of -0.72%/year.

14 SOLAR ENERGY↗

Degradation mechanisms and partial shading of glass-backsheet and double-glass photovoltaic modules in three climate zones determined by remote monitoring of time-series current–voltage and power datastreams

Degradation and partial shading impact the long-term reliability and power production of photovoltaic (PV) modules and power plants. Time-series power (P mp ) and current–voltage (I-V) curve datastreams from PV modules enable a remote diagnostic approach to quantify active degradation mechanisms and identify partial shading. We study three to nine years of these datastreams, including 3.6 million P mp I-V curves and 36 million values, from eight PV modules, four each of double-glass and glass-backsheet module architectures, located in three distinctly different Köppen-Geiger climate zones, to determine the module’s performance loss rates (PLR), identify active degradation mechanisms and power loss modes, along with partial shading by local objects. Considering both module architectures, PLR results indicate that the BSh climate zone is the most aggressive for module degradation, while the Alpine ET zone is the mildest climate. PLR of double-glass modules located in BWh and BSh climate zones are different due to the significantly greater uniform current loss (ΔP Isc ) for double-glass modules in BSh, at a 5% significance level. Power loss for four out of five modules located in the BWh and BSh climates are dominated by uniform current degradation. Statistical analysis of multistep I-V curves detects partial shading experienced by three studied modules with details of the shading profile, the shading Poynting vector diagram for the obstacle’s relative position, shading scenarios, and duration. Lastly, this work demonstrates how remote monitoring and diagnosis of P mp & I-V time-series of modules can provide quantitative operations and maintenance insights into system performance, degradation mechanisms, and shading.

14 SOLAR ENERGY↗

PVplr-stGNN 0.1.10

PV Performance Loss Rate Estimation using Spatio-temporal Graph Neural Networks PVplr-stGNN is a Python 3 package developed by the SDLE Research Center at Case Western Reserve University in Cleveland OH. This repository contains the full source PVplr-stGNN package. The package contains the PV-stGAE for missingness data detection and imputation and PV-DynGNN for PLR estimation.

Fan, Yangxin [Case Western Reserve Univ., Clevelan↗

Network Models of Active Degradation Mechanisms and Pathways for Service Life Prediction of Indoor and Outdoor PV Modules

ct: PV service lifetime prediction (SLP) enables accurate calculation of levelized cost of energy (LCOE), which is crucial to rationalizing PV investment and installation. However, SLP is challeging since PV reliability in the field is affected by many combined factors, including various environmental stresses and module quality. In order to map out the active degradation mechanisms and pathways that best resemble real world conditions, we introduce the framework of a study protocol and use network models fitted to data, to enable analysis and SLP of complex PV systems with multiple active degradation mechanisms. The study protocol is the experimental design, including module variants and different exposure conditions, selection of evaluation methods, time-series data acquisition and training of network models to these data. We present SLP of minimodules in the lab and PV systems in the field. For lab SLP, minimodules with 8 variants based on manufacturer, architecture, and encapsulation were prepared and aged in modified damp heat with or without full spectrum light exposure. Stepwise I-V and Suns-Voc data acquisition tracks changes in electrical properties including Rs,IV, Isc,IV, Vmp,PIV providing insights into power loss of minimodules. Network structural equation modeling (netSEM) was utilized to construct degradation pathway models that identify active degradation mechanisms and predict power loss over time. For field SLP, datastreams of Pmp values and I-V curve datastreams of two types of modules installed in three distinctly different Köppen-Geiger climate zones for 9 years were acquired. With power loss modes corresponding to uniform current loss (ΔPIsc), recombination (ΔPVoc), series resistance (ΔPRs), and current mismatch (ΔPImis) determined, the performance loss rates (PLR) were determined using PVplr. We show how to establish a study protocol framework to ensure appropriate parametric variations and valid data collection from the variants of your complex systems. Then the data-driven netSEM model fitting provides a comprehensive mapping of multiple active degradation mechanisms, and accurate service life prediction.

network model, degradation, photovoltaic, solar↗

Extreme Weather Events and the Impact on PV Time Series Data

The impact of extreme weather events on PV performance was studied by comparing the National Oceanic and Atmospheric Administration database on severe weather with the PV Fleet database on continuous PV performance. We identified 170 systems that were immediately impacted by weather events. These severe weather events lead to a median loss of only 1% of annual production. However, flooding and high wind events were found to have an extremely long tail extending to 60 % loss showing that these discrete events can pose a substantial risk to PV systems. Besides the short-term impact of lost production due to outages, we also found a statistically significant increased performance loss rate (PLR) for high wind events comparing PLR before and after these weather events. In addition, hail events caused a higher PLR for 2 out of 3 systems. More data are required to better quantify the impact, but these first results illustrate the substantial risk these events pose short-and long-term.

degradation↗

Extreme Weather Events and PV Systems Impact

The impact of extreme weather events on PV performance was studied by comparing the National Oceanic and Atmospheric Administration database on severe weather with the National Renewable Energy Laboratory's (NREL) PV Fleet database on continuous PV performance. We identified 170 systems that were immediately impacted by weather events. These severe weather events lead to a median loss of only 1 % of annual production. However, flooding and high wind events were found to have an extremely long tail extending to 60 % loss, showing that these discrete events can pose a substantial risk to PV systems. Besides the short-term impact of lost production due to outages, we also found a statistically significant increased performance loss rate (PLR) for high wind events above 90 kilometer/hour, by comparing PLR before and after these events. Similarly, hail events caused higher PLR for hail sizes of and above 25 mm indicating that more stringent hail testing for PV modules is required. In addition, very high snow loads may also cause increased PLRs, but more data are required to better quantify the impact. These findings illustrate the substantial risk extreme weather events pose short-and long-term to fielded PV installations.

extreme weather↗

Photovoltaics module reliability for the terawatt age

Photovoltaics (PV), or solar electricity generation, has become the cheapest form of energy in many locations worldwide and, combined with energy storage, has the potential to satisfy most of our electricity needs. PV has grown at an annual compounded growth rate of approximately 30% in the last three decades. Solar energy systems will continue their impressive growth in distributed energy, microgrids, and utility scale, as efforts are made for dependable electricity in an age with increasing extreme weather. However, within this remarkable success lies a new challenge. The growth curve, combined with rapid product innovation and scale up, means that the majority of PV systems are new, without the three years of performance data that have been required in the past to estimate product lifetime. PV reliability has to address this challenge. In this review we present a brief summary of PV reliability starting with brief historical synopsis, detailing some of the technological challenges and present a framework required for long lifetime.

14 SOLAR ENERGY↗

Onymous early‐life performance degradation analysis of recent photovoltaic module technologies

Abstract The cost of photovoltaic (PV) modules has declined by 85% since 2010. To achieve this reduction, manufacturers altered module designs and bill of materials; changes that could affect module durability and reliability. To determine if these changes have affected module durability, we measured the performance degradation of 834 fielded PV modules representing 13 module types from 7 manufacturers in 3 climates over 5 years. Degradation rates ( Rd ) are highly nonlinear over time, and seasonal variations are present in some module types. Mean and median degradation rate values of −0.62%/year and −0.58%/year, respectively, are consistent with rates measured for older modules. Of the 23 systems studied, 6 have degradation rates that will exceed the warranty limits in the future, whereas 13 systems demonstrate the potential of achieving lifetimes beyond 30 years, assuming Rd trends have stabilized.

14 SOLAR ENERGY↗

Reducing Uncertainty of Fielded Photovoltaic Performance (Final Technical Report)

Improved analysis and reporting of photovoltaic (PV) field performance increases the certainty of owners and financiers that systems will perform as expected. Advanced module technologies (e.g., PERC, HJT, and bifacial) introduce new degradation mechanisms and performance characteristics. The FY19-21 Reducing Uncertainty project leveraged data from the ever-increasing PV fleet to develop models and understanding of the field performance of existing and new technologies. Specifically, we accomplished: report on field performance and degradation rates for high-efficiency silicon (HJT, PERC, IBC) and more conventional technologies; developed automated analysis techniques to quantify system performance (performance ratio, energy yield) and production shortfalls (soiling, degradation, availability); refined the RdTools software toolkit to bring standard, validated analysis techniques to bear on third-party data; analyzed and reported on large datasets including Treasury data and Lawrence Berkeley National Laboratory's Utility-Scale dataset to expand the high-quality degradation-rate histogram published previously; worked with industry partners and the DuraMAT data hub to enable private parties to share and aggregate PV production data anonymously, leveraging cloud-based data analysis infrastructure and publishing on US fleet-scale performance comprising over 7GW of operating systems. (https://www.nrel.gov/pv/fleet-performance-data-initiative.html). Through our industry collaborations we have engaged in NDA-covered data transfer with twelve PV fleet owners as of January 2022, with more agreements in negotiation. Our scalable cloud-based time series database contains over 30 billion rows (20TB) of PV time series data, representing over 1700 commercial and utility-scale systems, and over 7.2 GW of DC capacity (Fig 1). Initial field performance results have been distributed in several public reports. Because our fleet composition and data quality methods are continually improving, annual updates to these results are published to our PV Fleet webpage [ https://www.nrel.gov/pv/fleet-performance-data-initiative.html ] and DuraMAT data hub [DOI: 10.21948/1842958]. Another existing dissemination channel used for observed soiling losses is a map we maintain for soiling losses. Additional products developed include a report detailing fleet-wide performance index, availability, startup loss and snow loss factors, a detailed report on the 1603 grant dataset comprising over 100,000 PV systems with failure and performance details and a utility-scale report coauthored with LBNL on 31 GW of system performance.

14 SOLAR ENERGY↗

Clear-sky detection for PV degradation analysis using multiple regression

A method is presented to detect clear-sky periods for plane-of-array irradiance time-averaged data that is based on the algorithm originally described by Reno and Hansen. Here we show this new method improves the state-of-the-art by providing accurate detection at longer data averaging intervals. Moreover, our new method detects clear periods in plane-of-array data, which is novel. The new method is developed by applying a Design of Experiment approach to optimize the parameters used in the Reno method, and Monte Carlo simulations are used to understand the robustness of the found parameters. Clear-sky detection accuracy is compared among four methods: the Reno method, the default clear-sky filter in RdTools, the Ellis method, and the method outlined in this work, using a hand-labeled two-year data set of 1-min plane-of-array irradiance for a fixed tilt system. The RdTools clear-sky filter is marred by excessive false positives. The other methods all perform well at 1-min data intervals; the method developed here provides more accurate detection at longer data averaging intervals. We show that the parameters are directly linked to the data frequency in the hope that these input variables may not have to be optimized for every data frequency and location. However, only a single fixed system in one location was carefully examined. Finally, we illustrate how accurate determination of clear-sky conditions helps to eliminate data noise and bias in the assessment of long-term performance of PV plants.

14 SOLAR ENERGY↗

A Loss Tolerant Rate Controller for Reliable Multicast

This paper describes the design, specification, and performance of a Loss Tolerant Rate Controller (LTRC) for use in controlling reliable multicast senders. The purpose of this rate controller is not to adapt to congestion (or loss) on a per loss report basis (such as per received negative acknowledgment), but instead to use loss report information and perceived state to decide more prudent courses of action for both the short and long term. The goal of this controller is to be responsive to congestion, but not overly reactive to spurious independent loss. Performance of the controller is verified through simulation results.

Montgomery, Todd↗

The ablation of graphitic materials in the sublimation regime.

A large variety of graphitic materials have been tested in an arc heated air stream at a surface pressure of 4.3 atm and a nominal surface temperature of 3925 K. Included were commercial and developmental grades of artificial graphites, both two and three dimensional carbon-carbon composites, composites seeded with refractory compounds, and several special materials such as pyrolytic graphite, mesophase graphite, glassy carbon, and natural graphite. ATJ graphite was used as a control material. Except for the seeded materials which had poor performance, the mass loss rate for all the man-made graphitic materials fell within the range of 17 per cent less to 30 per cent more than the rate for ATJ. Thus it is concluded that wide variations in constituents, processing, fabrication and structure have relatively little effect on the ablation performance of graphitic materials, at least under the conditions of the present tests. Particulate mass loss was observed for all the materials tested and is the dominant mechanism for mass removal at the present test conditions. It is suggested that this mechanism results from physical failure, primarily by compressive thermal stress.

Lundell, J. H.↗

Performance of solar leasing for low- and middle-income customers in Connecticut

Policymakers are increasingly interested in expanding access to rooftop photovoltaic systems. This study analyzes the financial performance of a Connecticut Green Bank (CGB) solar leasing program, run in partnership with PosiGen, that targets low- and moderate-income customers. We show that this program has successfully reached underserved customers and has reasonable repayment rates given the credit characteristics of the participants. The CGB/PosiGen program reaches many more underserved customers than other PV financing programs in Connecticut.For example, the majority of CGB/PosiGen participants (58%) live in census tracts that have a median income of less than 80% of the area median income (AMI). In contrast, only 9% of participants in the other CGB solar financing programs live in these census tracts. Furthermore, the majority of CGB/PosiGen participants (56%) have FICO scores that would generally be considered non-prime (<670), whereas only 2% of participants in the other programs have similarly low scores. Credit, not income, is the primary factor that explains participants’ financial performance. Overall, we find that delinquency and annualized losses are higher for PosiGen (2.3% and 0.9%) than for other CGB programs (1.4% and 0.1%). Across the CGB programs, lower credit scores are associated with higher rates of delinquency and loss. Therefore, participants’ lower credit scores explain much of the program’s higher rates of delinquency and annualized losses. PosiGen leases perform competitively with market-rate solar and non-solar leases and loans. When compared to securities backed by market-rate PV loans and leases with similar amounts of seasoning, we find that the PosiGen leases have higher delinquency rates but comparable gross loss rates. The similarity in losses is notable given that loss rates for PosiGen leases were higher than those of the other CGB leases and loans. Rather than the PosiGen leases having high loss rates, other CGB leases and loans have unusually low loss rates. We also compare PosiGen to non-solar benchmarks, including indices of auto and consumer loans. We find that the PosiGen leases have significantly less delinquency than non-prime auto loans and have performance comparable to many consumer loans. The U.S. Department of Energy’s Solar Energy Technologies Office supported this research.

14 SOLAR ENERGY↗

Failure diagnosis and trend‐based performance losses routines for the detection and classification of incidents in large‐scale photovoltaic systems

Abstract Fault detection and classification in photovoltaic (PV) systems through real‐time monitoring is a fundamental task that ensures quality of operation and significantly improves the performance and reliability of operating systems. Different statistical and comparative approaches have already been proposed in the literature for fault detection; however, accurate classification of fault and loss incidents based on PV performance time series remains a key challenge. Failure diagnosis and trend‐based performance loss routines were developed in this work for detecting PV underperformance and accurately identifying the different fault types and loss mechanisms. The proposed routines focus mainly on the differentiation of failures (e.g., inverter faults) from irreversible (e.g., degradation) and reversible (e.g., snow and soiling) performance loss factors based on statistical analysis. The proposed routines were benchmarked using historical inverter data obtained from a 1.8 MWp PV power plant. The results demonstrated the effectiveness of the routines for detecting failures and loss mechanisms and the capability of the pipeline for distinguishing underperformance issues using anomaly detection and change‐point (CP) models. Finally, a CP model was used to extract significant changes in time series data, to detect soiling and cleaning events and to estimate both the performance loss and degradation rates of fielded PV systems.

14 SOLAR ENERGY↗

Evaluating scheduling algorithms for traffic with heterogeneous performance objectives

Two types of network traffic are considered: traffic with deadlines, for which the most important performance objective is based on loss rate, and packets without deadlines, for which the most important performance objective is based on mean delay. An optimal scheduling algorithm is presented to minimize weighted loss rate and weighted mean delay in the queues that form at the switches and at the network access points of a packet-switched network, where weights reflect the relative importance of packets. Although not practical for implementation, the algorithm is intended as a standard for the comparison of the performance of other scheduling algorithms. The algorithm is more general and lower computational complexity than previously published algorithms, enabling performance evaluation of some important scenarios that could not previously have been considered. Using the optimal performance results of this algorithm, the performance of the first-come-first-served, static priority, and earliest deadline first scheduling algorithms is evaluated. The results suggest that network efficiency could be improved by using a more sophisticated heuristic scheduling algorithm rather than one of the aforementioned algorithms.

Peha, Jon M.↗

Assessing C2 Communications for UAS Traffic Management

The National Aeronautics and Space Administration's (NASA) Unmanned Aircraft Systems (UAS) Traffic Management (UTM) project works to develop tools and technologies essential for safely enabling civilian low-altitude UAS operations. Currently there is no established infrastructure to enable and safely manage the widespread use of low-altitude airspace and UAS operations, regardless of the type of UAS. The UTM technical challenge will develop comprehensive and validated airspace operations and integration requirements to safely enable large-scale persistent access to visual line of sight and autonomous beyond visual line of sight small UAS in low-altitude airspace. Within the UTM project, a number of communications technologies to support UTM command and control (C2) are under investigation. In particular, commercial networked cellular systems are being tested and assessed for their ability to meet the reliability, scalability, cybersecurity and redundancy required. NASA Glenn Research Center is studying some of the aspects of employing such networks for UTM C2 communications. This includes the development of a test platform for sensing and characterizing the airborne C2 communications environment at various altitudes and in various terrains and topologies, measuring such aspects as received signal strength and interference. System performance aspects such as latency in the link, handover performance, packet error loss rate, drop outs, coverage gaps and other aspects impacting UTM operation will also be assessed. In this paper we explore some of the C2 approaches being proposed and demonstrated in the UTM project, the reliability, availability and other general C2 performance requirements, and approaches to evaluating and analyzing UTM C2 links based on commercial cellular networks.

air traffic control↗