Comparison of computer-acquired performance data from several fixed spaced planar diodes
Comparison of performance data envelopes for thermionic diodes with various tungsten or rhenium emitters and niobium or molybdenum collectors
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Comparison of performance data envelopes for thermionic diodes with various tungsten or rhenium emitters and niobium or molybdenum collectors
Performance data from an etched-rhenium, molybdenum thermionic converter are presented. The planar converter has a guard-ringed collector and a fixed spacing of 0.254 mm (10 mils). The data were acquired by using a computer and are available on microfiche as individual or composite parametric current, voltage curves. The parameters are the temperatures of the emitter T sub E, collector T sub C and cesium reservoir T sub R. The composite plots have constant T sub E, and varying T sub C or T sub R, or both. The envelope and composite plots having constant I sub E are presented. The diode was tested at increments between 1500 and 2000 K for the emitter, 750 and 1100 K for the collector, and 540 and 640 K for the reservoir. In all, 774 individual current, voltage curves were obtained.
Performance data obtained with recording oscillographs are presented to show the transient response of the General Electric Integrated Electronic Control operating on the J47 RXl-3 turbo-Jet engine over a range of altitudes from 10,000 to 45,000 feet and at ram pressure ratios of 1.03 and 1.4. These data represent the performance of the final control configuration developed after an investigation of the engine transient behavior in the NACA altitude wind tunnel. Oscillograph traces of controlled accelerations (throttle bursts),oontrolled decelerations (throttle chops), and controlled altitude starts are presented.
This paper represents the results of a program in which a flight test vehicle was flown for a limited number of flights. The vehicle was the Space Shuttle Orbiter. The total free flight time for the entire flight test program was less than half an hour. The flight regime tested represented only the approach and landing phase of the vehicle's planned flight capability. The program relied heavily on an extensive wind tunnel test program to predict the aerodynamic performance data over the complete flight range, as well as to predict data tolerances. During the flight test program, short maneuvers performed were to provide flight motion data. A data extraction program was developed to produce flight derived aerodynamic performance data in coefficient form from the motion data. The resultant flight test data was correlated with the predicted data and fell within the predicted data tolerances for all phases of the subsonic flight test regime, including ground effects.
Performance data from a chemically vapor-deposited-rhenium, niobium thermionic converter are presented. The planar converter has a guard-ringed collector and a nominal fixed spacing of 0.25 mm (10 mils). The data were obtained by using a computerized acquisition system and are available on request to one of the authors on microfiche as individual and composite parametric current, voltage curves. The parameters are the temperatures of the emitter T sub E collector T sub C, and cesium reservoir T sub R. The composite plots have constant T sub E and varying T sub C or T sub R, or both. Current, voltage envelopes having constant T sub E with and without fixed T sub C appear in the present report. The diode was tested at increments between 1600 and 2000 K for the emitter Hohlraum, 800 to 1100 K for the collector, and 540 and 650 K for the reservoir. A total of 312 current, voltage curves were obtained in the present performance evaluation. Current, voltage envelopes from three rhenium emitter converters evaluated in the present program are also given. The data are compared at commom emitter Hohlraum temperatures.
Computer processed performance data for thermionic converter with etched rhenium emitter and niobium collector
The most comprehensive performance data base currently available for SEP comet and asteroid rendezvous missions has been synthesized and reduced into forms allowing evaluation of primary mission planning parameters. These data are based on utilization of the Shuttle with a Centaur injection stage and a SEP system having a 3000-sec specific impulse. The analysis indicates that a SEP vehicle system designed at a power level of around 20 kW with a system operating life of three years, offers the capability for achieving rendezvous missions to almost all comet and asteroid targets expected to be of interest in the 1980s. This degree of mission selection flexibility is desirable for a comprehensive program of small body exploration.
Computer acquired performance data from physically vapor deposited tungsten-niobium thermoinic converter
Data were obtained in an altitude test chamber for a range of altitudes from 20,000 to 58,000 feet at a flight Mach number of 0.9, and for several flight Mach numbers at an altitude of 45,000 feet. Data approximating sea-level operation are also included. Engine component performance data are presented in addition to windmilling, exhaust-nozzle, and ejector performance.
Performance data on the General Electric 5BT 2366C10 series wound dc motor and EV-1 Chopper Controller is supplied for the electric vehicle manufacturer. Data is provided for both straight and chopped dc input to the motor, at 2 motor temperature levels. Testing was done at 6 voltage increments to the motor, and 2 voltage increments to the controller. Data results are presented in both tabular and graphical forms. Tabular information includes motor voltage and current input data, motor speed and torque output data, power data and temperature data. Graphical information includes torque-speed, motor power output-speed, torque-current, and efficiency-speed plots under the various operating conditions. The data resulting from this testing shows the speed-torque plots to have the most variance with operating temperature. The maximum motor efficiency is between 86% and 87%, regardless of temperature or mode of operation. When the chopper is utilized, maximum motor efficiency occurs when the chopper duty cycle approaches 100%.
Thrust performance data for low power magnetoplasmadynamic arc thruster
Performance data in argon for small, low specific speed, ten stage turbine applicable to SNAP 8
Performance data on the Prestolite MTC-4001 series wound dc motor and General Electric EV-1 Chopper Controller is supplied for the electric vehicle manufacturer. Data are provided for both straight and chopped dc input to the motor, at 2 motor temperature levels. Testing was done at 6 voltage increments to the motor, and 2 voltage increments to the controller. Data results are presented in both tabular and graphical forms. Tabular information includes motor voltage and current input data, motor speed and torque output data, power data and temperature data. Graphical information includes torque-speed, motor power output-speed, torque-current, and efficiency-speed plots under the various operating conditions. The data resulting from this testing show the speed-torque plots to have the most variance with operating temperature. The maximum motor efficiency is between 76% and 82%, regardless of temperature or mode of operation.
A facility was constructed to evaluate solar collector performance outdoors for conditions that would be encountered by collectors if they were incorporated in a solar heating/cooling system. In addition to obtaining initial collector performance data, the outdoor facility will enable collector durability and degradation rates to be evaluated for operating periods of several months. The data obtained from the outdoor tests were compared to collector performance predicted on the basis of results obtained with a solar simulator. The performance measured outdoors was less than the predicted performance.
A facility was constructed to evaluate solar collector performance outdoors for conditions that would be encountered by collectors if they were incorporated in a solar heating/cooling system. In addition to obtaining initial collector performance data, the outdoor facility will enable collector durability and degradation rates to be evaluated for operating periods of several months. The data obtained from the outdoor tests were compared to collector performance predicted on the basis of results obtained with a solar simulator. The performance measured outdoors was less than the predicted performance.
A system is presented which will reduce analog cardiac performance data and convert the results to digital form for direct entry into a commercial time-shared computer. Circuits are discussed which perform the measurement and digital conversion of instantaneous systolic and diastolic parameters from the analog blood pressure waveform. Digital averaging over a selected number of heart cycles is performed on these measurements, as well as those of flow and heart rate. The determination of average cardiac output and peripheral resistance, including trends, is the end result after processing by digital computer.
A collection of noncavitating blade-element performance data for 12 axial-flow pump rotor configurations is presented in tabular form. Rotor design philosophy, test apparatus and procedure, and data reduction and evaluation are discussed. A data storage and recall computer program is described. All but one of the rotor configurations considered were composed of double-circular-arc blade sections and were designed for high inlet relative flow angles. Hub-tip radius ranged from 0.40 to 0.90.
Approximate expressions are presented which correlate experimental performance data from a CVD tungsten-niobium, planar thermionic converter. The current voltage characteristics are given as functions of emitter and collector temperatures and cesium pressure for currents below the knee in the ignited mode. The correlation covers the temperature ranges of 1700 to 1950 K for the emitter, 900 to 1050 K for the collector, and 580 to 645 K for the cesium reservoir.