Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “performance bound”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

NASMDR: a framework for miRNA-drug resistance prediction using efficient neural architecture search and graph isomorphism networks

Abstract As a frontier field of individualized therapy, microRNA (miRNA) pharmacogenomics facilitates the understanding of different individual responses to certain drugs and provides a reasonable reference for clinical treatment. However, the known drug resistance-associated miRNAs are not yet sufficient to support precision medicine. Although existing methods are effective, they all focus on modelling miRNA-drug resistance interaction graphs, making their performance bounded by the interaction density. In this study, we propose a framework for miRNA-drug resistance prediction through efficient neural architecture search and graph isomorphism networks (NASMDR). NASMDR uses attribute information instead of the commonly used interactive graph information. In the cross-validation experiment, the proposed framework can achieve an AUC of 0.9468 on the ncDR dataset, which is 2.29% higher than the state-of-the-art method. In addition, we propose a novel sequence characterization approach, k-mer Sparse Nonnegative Matrix Factorization (KSNMF). The results show that NASMDR provides novel insights for integrating efficient neural architecture search and graph isomorphic networks into a unified framework to predict drug resistance-related miRNAs. The codes for NASMDR are available at https://github.com/kaizheng-academic/NASMDR.

Zheng, Kai↗

Report on Year-2 of Water NSTF Matrix Testing

Under support from the Department of Energy (DOE) and the Office of Advanced Reactor Technologies (ART), a large scale test facility has been constructed at Argonne National Laboratory to generate NQA-1 qualified validation data for passive decay heat removal systems of advanced reactors. The Natural convection Shutdown heat removal Test Facility (NSTF) reflects key features of a ½ scale, water-based, Reactor Cavity Cooling System (RCCS) and is intended to study the behavior, bound performance, and ultimately guide design decisions for passive decay heat removal systems for advanced reactors. Since the facility also retains all aspects common to a fundamental boiling water thermosiphon, the generated experimental data sets are well poised to advance the understanding of fundamental natural circulation boiling and two-phase flow phenomena.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Report on Year-3 of Water NSTF Matrix Testing: Two-Phase Parametric Test Series

The Natural convection Shutdown heat removal Test Facility (NSTF) is large scale test facility constructed at Argonne National Laboratory to generate NQA-1 qualified validation data for passive decay heat removal systems in advanced reactor concepts. With support from the Department of Energy (DOE) offices of Advanced Reactor Technologies (ART) and Advanced Reactors Regulatory Development (RD), this facility reflects key features of a ½ scale, water-based, Reactor Cavity Cooling System (RCCS) and is intended to study the behavior, bound performance, and ultimately guide design decisions for passive decay heat removal systems. Since the facility also retains all aspects common to a fundamental boiling water thermosiphon, the generated experimental data sets are well poised to advance the understanding of fundamental natural circulation boiling and two-phase flow phenomena.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Report on Year-4 of Water NSTF Matrix Testing: Facility Maintenance and Accident Testing

Under support from the Department of Energy (DOE) and the Office of Advanced Reactor Technologies (ART), a large-scale test facility has been constructed at Argonne National Laboratory to generate NQA-1 qualified validation data for passive decay heat removal systems in advanced reactors. The Natural convection Shutdown heat removal Test Facility (NSTF) reflects key features of a ½ scale, water-based, Reactor Cavity Cooling System (RCCS) and is intended to study the behavior, bound performance, and ultimately guide design decisions for passive decay heat removal systems for advanced reactors. In addition to the experimental activities detailed in this report, a supportive computational modeling effort is on-going which has been demonstrated to significantly strengthen the experimental program while also improving accuracy of the computer models. Together these create a mutually beneficial relationship integral to meeting the overall program objective of examining the heat removal performance of the RCCS concept. This report serves as a summary of maintenance and experimental activities during the program’s fourth year of water-based operation. A planned six-month maintenance period began in August 2021, during which major inspections, repairs, cleaning, and installation of new instrumentation and data acquisition hardware were conducted. Most significantly, two heaters that faulted during Year-3 were repaired, allowing the facility to resume use of the full heated section area and full range of available electric power. The remainder of the year consisted of eight months of test operations, during which the facility logged 211 hours of active heating across one bake-out (following the maintenance period) and seven matrix tests; five classifieds as Accepted per NQA-1, one as Trending, and one as Failed. Testing began by performing two repeat cases to confirm expected facility response and behavior during both single- and two-phase flow conditions, ensuring no changes were introduced during the maintenance period that might have altered the thermal-hydraulic characteristics of the facility. In continuation of the power parametric series initiated in previous years, a high-power test case was then performed examining heat removal performance at a decay heat load equivalent to 2.4 MWt, full-scale, a level exceeding maximum design targets. Additional testing then introduced various blockage scenarios along the network piping, examining the effects of partial and complete blockages of the flow paths on the system behavior and heat removal performance. A study of static boiling tests directed at understanding the geysering two-phase instability was also conducted. The loop was filled only to the bottom of the tank outlet, creating an open loop configuration that prevents any natural circulation flow from occurring, and the heaters were powered on until the facility reached saturation conditions. Following, a series of quasi-steady-state conditions were introduced by adjusting the inventory level in the adiabatic chimney piping at decreasingly lower elevations above the heated region. A strong correlation of geysering characteristics and loop level was observed, with flow and temperature excursions decreasing in intensity, but increasing in frequency, as the fill were reduced to lower elevations along the chimney piping. Once the level fell very low in the chimney, at points near the top of the heated section, the system reached a stable state of continuous boiling without any occurrence of geysering eruptions. A final significant testing accomplishment this year was successful completion of an “accident scenario” test, whose operating conditions were based on a prototypic decay heat curve provided by Framatome and scaled for the NSTF. This test began by establishing steady-state, single-phase “normal operation” conditions, before simulating an accident trip where the availability of active cooling systems was lost. Loop temperatures gradually increased until reaching saturation and subsequent two-phase boiling flow. Over the course of an extended operational period along the defined decay heat curve, steam boil-off caused gradual but continued depletion of liquid inventory until reaching a critically low level causing flow stagnation and cessation of natural circulation heat removal. At this point, after nearly 72 hours of continuous operation, a cold refill was performed to replenish the system inventory and allow the facility to re-establish closed loop natural circulation flow and return to a safe operational state.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

FY23 Report on Water NSTF Testing at Two-Phase Conditions: Off-normal Scenarios

Under support from the Department of Energy (DOE) and the Office of Advanced Reactor Technologies (ART), a large-scale test facility has been constructed at Argonne National Laboratory to generate NQA-1 qualified validation data for passive decay heat removal systems in advanced reactors. The Natural convection Shutdown heat removal Test Facility (NSTF) reflects key features of a ½ scale, water-based, Reactor Cavity Cooling System (RCCS) and is intended to study the behavior, bound performance, and ultimately guide design decisions for passive decay heat removal systems for advanced reactors. In addition to the experimental activities detailed in this report, a supportive computational modeling effort is on-going which has been demonstrated to significantly strengthen the experimental program while also improving accuracy of the computer models. Together these create a mutually beneficial relationship integral to meeting the overall program objective of examining the heat removal performance of the RCCS concept. This report details the experimental activities and upgrades performed during the program’s fifth year of water-based operation. The theme of this year of testing was examining off-normal scenarios. In practice, that meant examining scenarios with blockages or other design basis conditions. From a maintenance and capability standpoint that meant assessing valving options for implementing blockages, assessing drain and refill capabilities, and ensuring in all cases that operators could safely, efficiently, and repeatably bring the facility to an off-normal condition and return it to the normal operating state. In one notable case, no solution existed, nor was a solution commercially available, that met the facility needs for implementing blockages within the two-phase region of the chimney. A valve and feedthrough were custom-designed for NSTF to operate submerged in saturated water while being safely actuated from outside the tank. The fifth year of testing included eight matrix tests consisting of 162 hours of active heating, 9,735 kWh of electrical heating, with seven tests classified as Accepted per NQA-1 and one as Trending. All matrix tests were performed at two-phase flow conditions. The power parametric series from previous years was extended to include another scenario with a decay load equivalent to 1.75 MWt, full scale, further resolving the system flow oscillation response as a function of input power. A depletion test was performed to extend previous work and examine the system’s approach to stagnation and geysering that were not previously observed. This test began at an initial inventory level of 50%, prototypic power of 2.1 MWt, and employed an accelerated drain of 0.75 gpm plus boiloff until stagnation conditions were achieved and multiple geysering events were recorded. Further exploring the geysering phenomenon was a separate effects test examining static boiling in the risers and chimney. This static boiling test was performed at 48 kWe, a higher power than testing in the previous year, and included enhancements to the drain system to remove inventory in a better-controlled and more reliable manner. Two tests were performed, at prototypic conditions of 1.4 MWt and 2.4 MWt, respectively, examining the system response to throttled conditions in the singlephase region of the piping. A ball valve immediately before he riser inlet header was increasingly throttled, progressing the system through a repeatable pattern of two-phase oscillations and stable regimes before ultimately inducing stagnation and geysering. Concluding the year, two tests were performed at baseline conditions of 70% initial inventory level and 2.1 MWt of prototypic decay heat to examine both repeatability and the response to throttling within the two-phase region, at the inventory tank inlet using the custom valve mentioned above. The first such test repeated transient operating conditions and revealed significant sensitivity t

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

An Optimal Power Control Strategy for Grid-Following Inverters in a Synchronous Frame

This work proposes a power control strategy based on the linear quadratic regulator with optimal reference tracking (LQR-ORT) for a three-phase inverter-based generator (IBG) using an LCL filter. The use of an LQR-ORT controller increases robustness margins and reduces the quadratic value of the power error and control inputs during transient response. A model in a synchronous reference frame that integrates power sharing and voltage–current (V–I) dynamics is also proposed. This model allows for analyzing closed-loop eigenvalue location and robustness margins. The proposed controller was compared against a classical droop approach using proportional-resonant controllers for the inner loops. Mathematical analysis and hardware-in-the-loop (HIL) experiments under variations in the LCL filter components demonstrate fulfillment of robustness and performance bounds of the LQR-ORT controller. Experimental results demonstrate accuracy of the proposed model and the effectiveness of the LQR-ORT controller in improving transient response, robustness, and power decoupling.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Performance Optimization for Relative-Error-Bounded Lossy Compression on Scientific Data

Scientific simulations in high-performance computing (HPC) environments generate vast volume of data, which may cause a severe I/O bottleneck at runtime and a huge burden on storage space for postanalysis. Unlike traditional data reduction schemes such as deduplication or lossless compression, not only can error-controlled lossy compression significantly reduce the data size but it also holds the promise to satisfy user demand on error control. Pointwise relative error bounds (i.e., compression errors depends on the data values) are widely used by many scientific applications with lossy compression since error control can adapt to the error bound in the dataset automatically. Pointwise relative-error-bounded compression is complicated and time consuming. In this article, we develop efficient precomputation-based mechanisms based on the SZ lossy compression framework. Our mechanisms can avoid costly logarithmic transformation and identify quantization factor values via a fast table lookup, greatly accelerating the relative-error-bounded compression with excellent compression ratios. In addition, we reduce traversing operations for Huffman decoding, significantly accelerating the decompression process in SZ. Experiments with eight well-known real-world scientific simulation datasets show that our solution can improve the compression and decompression rates (i.e., the speed) by about 40 and 80 p, respectively, in most of cases, making our designed lossy compression strategy the best-in-class solution in most cases.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Genetic algorithm optimization of a chemical kinetic mechanism for propane at engine relevant conditions

Propane has demonstrated significant potential for reductions in greenhouse gas and pollutant emissions in medium- and heavy-duty engine applications, but further improvements require accurate, compact, and scalable chemical kinetic mechanisms to design the next generation of propane fueled engines, particularly at the boosted operating conditions necessary to meet the power density demand of medium- and heavy-duty applications. In this work, six key chemical reactions were identified in a reduced mechanism with 70 species and 352 reactions through a sensitivity analysis performed at conditions typical of thermodynamic trajectories observed in a high compression ratio, long stroke engine operated on propane from throttled to boosted operating conditions. While the original mechanism was validated against rapid compression machine (RCM) data, it was found to overpredict experimental autoignition tendencies in 2-zone, 0-D SI engine simulations performed in Chemkin Pro. Subsequently, a genetic algorithm approach was used to optimize the six reaction rate parameters within established uncertainty bounds by performing RCM simulations and comparing to two independent sets of literature ignition delay times for propane, thus generating two new kinetic mechanisms. The first optimization achieved a mean absolute percent error (MPE) reduction in 2nd stage ignition delay of 61.4% in seven generations, while the second optimization utilized a newer experimental RCM dataset, and achieved MPE reduction of 56.7% in seven generations, and further marginal improvement to 57.8% reduction in 34 generations. Finally, the two mechanisms were then evaluated again in the 2-zone 0-D SI engine model in Chemkin Pro comparing typical mean and knocking cycle trajectories, and it was found that the second optimized mechanism provided better prediction of knock onset at the representative conditions evaluated in this work, particularly for higher load operating conditions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Final Design of Vacuum Pumping Systems for the Material Plasma Exposure eXperiment

The Material Plasma Exposure eXperiment (MPEX) vacuum pumping system is responsible for creating prototypic conditions in the plasma material interaction chamber that mimic those in a fusion reactor divertor region. Additionally, the vacuum system needs to minimize the pressure in the plasma heating region to improve the coupling of the electron cyclotron heating and ion cyclotron heating to the plasma, minimizing waste heat exhausted to high heat flux components. Here, the final design of the system has been sized to comply with the vacuum pump operating environment and to reduce the number of unique pumps required while meeting performance requirements. Bounding cases with and without the plasma present have been developed in the pumping analysis, and an initial calculation has been performed based on the plasma pumping identified in Proto-MPEX operation though this result will remain unverified until MPEX operation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optimal band structure for thermoelectrics with realistic scattering and bands

Abstract Understanding how to optimize electronic band structures for thermoelectrics is a topic of long-standing interest in the community. Prior models have been limited to simplified bands and/or scattering models. In this study, we apply more rigorous scattering treatments to more realistic model band structures—upward-parabolic bands that inflect to an inverted-parabolic behavior—including cases of multiple bands. In contrast to common descriptors (e.g., quality factor and complexity factor), the degree to which multiple pockets improve thermoelectric performance is bounded by interband scattering and the relative shapes of the bands. We establish that extremely anisotropic “flat-and-dispersive” bands, although best-performing in theory, may not represent a promising design strategy in practice. Critically, we determine optimum bandwidth, dependent on temperature and lattice thermal conductivity, from perfect transport cutoffs that can in theory significantly boost z T beyond the values attainable through intrinsic band structures alone. Our analysis should be widely useful as the thermoelectric research community eyes z T > 3.

97 MATHEMATICS AND COMPUTING↗

Evaluating performance and portability of high-level programming models: Julia, Python/Numba, and Kokkos on exascale nodes

We explore the performance and portability of the high-level programming models: the LLVM-based Julia and Python/Numba, and Kokkos on high-performance computing (HPC) nodes: AMD Epyc CPUs and MI250X graphical processing units (GPUs) on Frontier’s test bed Crusher system and Ampere’s Arm-based CPUs and NVIDIA’s A100 GPUs on the Wombat system at the Oak Ridge Leadership Computing Facilities. We compare the default performance of a hand-rolled dense matrix multiplication algorithm on CPUs against vendor-compiled C/OpenMP implementations, and on each GPU against CUDA and HIP. Rather than focusing on the kernel optimization per-se, we select this naive approach to resemble exploratory work in science and as a lower-bound for performance to isolate the effect of each programming model. Julia and Kokkos perform comparably with C/OpenMP on CPUs, while Julia implementations are competitive with CUDA and HIP on GPUs. Performance gaps are identified on NVIDIA A100 GPUs for Julia’s single precision and Kokkos, and for Python/Numba in all scenarios. We also comment on half-precision support, productivity, performance portability metrics, and platform readiness. We expect to contribute to the understanding and direction for high-level, high-productivity languages in HPC as the first-generation exascale systems are deployed.

Godoy, William↗

Variability in Diurnal and Seasonal Ambient Conditions on Geothermal Plant Performance and Cost: Preprint

Geothermal plant performance is bounded by the second law efficiency, which accounts for the quantity of exergy that can be converted into useful work. This in turn is dependent on the geothermal resource temperature and the temperature of the heat sink (i.e., the ambient temperature). In this study we show that ambient temperature variability on a diurnal and seasonal basis can affect performance and cost estimations for geothermal plants. We have utilized the updated System Advisor Model (SAM) to assess nine geothermal sites with existing resource capacities across three climate zones. Our analysis shows that both evaporatively-cooled flash and air-cooled binary cycle plants are affected by temperature, with a slightly higher effect in EGS binary sites. By assuming an ambient (wet bulb) temperature baseline of 15.6 degrees C (60 degrees F) and comparing baseline results to those from site-specific data we observe up to 15% underestimation of plant performance and up to 20% overestimation of cost.

ambient temperature↗

Variability in Diurnal and Seasonal Ambient Conditions on Geothermal Plant Performance and Cost

Geothermal plant performance is bounded by the second law efficiency, which accounts for the quantity of exergy that can be converted into useful work. This, in turn, is dependent on the geothermal resource temperature and the temperature of the heat sink (i.e., the ambient temperature). In this study, we show that ambient temperature variability on a diurnal and seasonal basis can affect performance and cost estimations for geothermal plants. We have utilized the updated System Advisor Model (SAM) to assess nine geothermal sites with existing resource capacities across three climate zones. Our analysis shows that both evaporatively-cooled flash and air-cooled binary cycle plants are affected by temperature, with a slightly higher effect in enhanced geothermal system binary sites. By assuming an ambient (wet bulb) temperature baseline of 15.6 degrees C (60 degrees F) and comparing baseline results to those from site-specific data, we observe up to 15% underestimation of plant performance and up to 20% overestimation of cost. These results make a case for the inclusion of location-based weather data as inputs to supply curves that are used in capacity expansion models for the prediction of future geothermal deployment scenarios.

ambient temperature↗

Toward scalable bound-to-resonance extrapolations for few- and many-body systems

In open quantum many-body systems, the theoretical description of resonant states of many particles strongly coupled to the continuum can be challenging. Such states are commonplace in, for example, exotic nuclei and hadrons, and can reveal important information about the underlying forces at play in these systems. In this work, we demonstrate that the complex-augmented eigenvector continuation (CA-EC) method, originally formulated for the two-body problem with uniform complex scaling, can reliably perform bound-to-resonance extrapolations for genuine three-body resonances having no bound subsystems. Here, we first establish that three-body bound-to-resonance extrapolations are possible by benchmarking different few-body approaches, and we provide arguments to explain how the extrapolation works in the many-body case. We furthermore pave the way towards scalable resonance extrapolations in many-body systems by showing that the CA-EC method also works in the Berggren basis, studying a realistic application using the Gamow shell model.

Ab initio calculations↗

Hydrocarbon ladder polymers with ultrahigh permselectivity for membrane gas separations

Membranes have the potential to substantially reduce energy consumption of industrial chemical separations, but their implementation has been limited owing to a performance upper bound—the trade-off between permeability and selectivity. Although recent developments of highly permeable polymer membranes have advanced the upper bounds for various gas pairs, these polymers typically exhibit limited selectivity. We report a class of hydrocarbon ladder polymers that can achieve both high selectivity and high permeability in membrane separations for many industrially relevant gas mixtures. Additionally, their corresponding films exhibit desirable mechanical and thermal properties. Tuning of the ladder polymer backbone configuration was found to have a profound effect on separation performance and aging behavior.

Science & Technology - Other Topics↗

Generalizable Porous Aromatic Framework‐Included Polymer Membranes for Diffusion‐Enhanced Gas Separations

Industrial separation processes account for 10-15% of global energy consumption. Membrane-based processes are less energy-intensive than traditional gas separation technologies; however, enhanced material separation performance and stability for numerous gas mixtures are needed for widespread industrial adoption. This work presents a generalizable strategy for preparing mixed-matrix gas separation membranes exceeding the performance upper bounds of existing polymer membranes for a wide variety of industrial gases. By incorporating robust porous aromatic framework (PAF) particles into various dense commercial polymer matrices, gas diffusivity and solubility can be enhanced. For diverse gas mixtures (e.g., CO2/N2, O2/N2, He/CH4, H2/N2, and C2H4/C2H6), the resulting composite membranes exhibit enhanced gas permeabilities-by as much as 520%-and largely unchanged selectivities even after 6 years of aging under simulated flue gas conditions. These improvements arise from the ultrahigh porosity, excellent chemical compatibility, and unique physicochemical properties of the embedded PAF particles. Functionalizing the PAFs with polyamines also enables composite membranes that achieve among the highest reported performances against plasticization, a common obstacle in commercializing gas separation membranes. Significantly, the PAF-1 particles are readily dispersible in various common membrane casting solvents, suggesting their broader utility as a filler for designing high-performance membranes for many industrial gas separations.

Uliana, Adam A↗