Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “peaking capacity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Third-Party Aggregation Rulemaking in MISO and SPP Footprints

The report highlights key considerations for retail regulators in the footprints of the Southwest Power Pool (SPP) or Midcontinent Independent System Operator (MISO) in states that previously opted out of allowing third-party aggregation participation under FERC Order 719 and that may want to explore reversing the decision due to a changing policy environment under new FERC orders (i.e., 2222) and/or tightening resource adequacy constraints. Through a document review and a series of 27 interviews with regulators, aggregators, and other industry professionals, this document provides a high-level policy overview of the retail regulator’s role in a selection of processes, rules, and regulations to better understand how states have treated and/or integrated aggregators into wholesale markets. The report summarizes findings in two sections: General Findings and Specific Policy Findings. The General Findings offer high level takeaways such as the fact that 17 of the 20 states in MISO and SPP footprints opted out of third party aggregations following Order 719. Additionally, there is only one state that is fully restructured in the MISO and SPP footprints whereas the rest are vertically integrated, and the majority of third-party aggregations in the U.S. take place in restructured states outside of these footprints. Even so, third-party aggregations do take place in MISO and SPP albeit in small numbers and in an ad hoc regulatory environment. The specific policy findings delve deeper into specific examples of state actions on the topics of jurisdiction, registration and licensing, data governance, dual participation, and dispute resolution. Tables in each category organize state actions into Tiers I-III, which roughly correspond to the possible level of involvement or possible change necessary by state regulators and/or legislators to implement these actions. The tier level does not indicate any value judgement, as each state has respective regulatory limitations and each decision comes with various tradeoffs. One main tradeoff is between simplicity and quick implementation versus comprehensive and prolonged implementation. In many cases, actions in Tier I could be implemented without significant changes by relying on the use of existing processes for an aggregator context. On the other hand, many actions in Tier III are more narrowly designed to address aggregators specifically, but often require more significant changes including the involvement of additional parties through stakeholder engagement or legislative action. In some cases, these tiers are discrete. However, state regulators may also choose to progress through these various tiers sequentially as they phase in aggregators while learning from their experience. With the ability to stack bulk system level services, distributed energy resource aggregations in MISO and SPP could provide various private benefits (e.g., increased value streams to the owner) as well as societally beneficial grid services (e.g., peaking capacity, ancillary services, and other services that increase the grid’s overall operational efficiency). In deciding how to best to enable these benefits, states and retail regulators must weigh various tradeoffs if considering reversing a previous opt out.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Experimental Investigation on Cooling performance of A Thermoelectric Freezer

Thermoelectric heat pumps (TEHPs) have found widespread use in the electronics cooling industry and portable refrigerators. However, there has been a lack of extensive research on the application of TEHPs in low-temperature refrigeration settings. To address this gap, various configurations of TEHPs were fabricated to assess their suitability for freezer applications. Key parameters such as cooling capacity and system performance of the TEHPs were crucial in evaluating these configurations. Three configurations, each with different numbers of cooling units and fan arrangements, were tested using a 300-liter freezer prototype under typical room conditions (21°C). A cooling unit is comprised of two-stage thermoelectric modules, an aluminum plate fin heat exchanger sink with fans positioned either on top or directing airflow through the center, and a cooling block with circulating icy water for heat dissipation. Across all configurations, the minimum temperature inside the freezer cabinet reached -16.0°C. The cooling capacity peaked at 74.7 W, with the thermoelectric coefficient of performance (COP) reaching a maximum of 0.45. System COP ranged from 0.23 to 0.28. Minimum TE power consumption was recorded at 138.8 W, with TE system power consumption at 174.4 W, indicating feasibility for practical residential freezer applications. This investigation lays the foundation for integrating TE freezers with ice thermal storage systems.

Hu, Yifeng↗

Seasonal trends in photosynthesis and leaf traits in scarlet oak

Understanding seasonal variation in photosynthesis is important for understanding and modelling plant productivity. Here, we used shotgun sampling to examine physiological, structural and spectral leaf traits of upper canopy, sun-exposed leaves in Quercus coccinea Münchh (scarlet oak) across the growing season in order to understand seasonal trends, explore the mechanisms underpinning physiological change, and investigate the impact of extrapolating measurements from a single date to the whole season. We tested the hypothesis that photosynthetic rates and capacities would peak at the summer solstice i.e., at the time of peak photoperiod. Contrary to expectations, our results reveal a late-season peak in both photosynthetic capacity and rate before the expected sharp decrease at the start of senescence. This late-season maximum occurred after the higher summer temperatures and VPD, and was correlated with the recovery of leaf water content and increased stomatal conductance. We modelled photosynthesis at the top of the canopy and found that the simulated results closely tracked the maximum carboxylation capacity of Rubisco. For both photosynthetic capacity and modelled top-of-canopy photosynthesis, the maximum value was therefore not observed at the summer solstice. Rather, in each case the measurements at and around the solstice were close to the overall seasonal mean, with values later in the season leading to deviations from the mean by up to 41% and 52% respectively. Overall, we found that the expected Gaussian pattern of photosynthesis was not observed. We conclude that an understanding of species- and environment-specific changes in photosynthesis across the season is essential for correct estimation of seasonal photosynthetic capacity.

54 ENVIRONMENTAL SCIENCES↗

Dual Impacts of Space Heating Electrification and Climate Change Increase Uncertainties in Peak Load Behavior and Grid Capacity Requirements in Texas

Around 60% of households in Texas currently rely on electricity for space heating. As decarbonization efforts increase, non‐electrified households could adopt electric heat pumps, significantly increasing peak (highest) electricity demand in winter. Simultaneously, anthropogenic climate change is expected to increase temperatures, the potential for summer heat waves, and associated electricity demand for cooling. Uncertainty regarding the timing and magnitude of these concurrent changes raises questions about how they will jointly affect the seasonality of peak demand, firm capacity requirements, and grid reliability. This study investigates the net effects of residential space heating electrification and climate change on long‐term demand patterns and load shedding potential, using climate change projections, a predictive load model, and a direct current optimal power flow (DCOPF) model of the Texas grid. Results show that full electrification of residential space heating by replacing existing fossil fuel use with higher efficiency heat pumps could significantly improve reliability under hotter futures. Less efficient heat pumps may result in more severe winter peaking events and increased reliability risks. As heating electrification intensifies, system planners will need to balance the potential for greater resource adequacy risk caused by shifts in seasonal peaking behavior alongside the benefits (improved efficiency and reductions in emissions).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Storage Futures Study: Four Phases Framework and Modeling

This webinar, presented by Paul Denholm and Will Frazier, incorporates material from two publications of the NREL Storage Futures Study: "The Four Phases of Storage Deployment: A Framework for the Expanding Role of Storage in the U.S. Power System" (https://www.nrel.gov/docs/fy21osti/77480.pdf) and "Storage Futures Study: Economic Potential of Diurnal Storage in the U.S. Power Sector" (https://www.nrel.gov/docs/fy21osti/77449.pdf).

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Aggregate residential demand flexibility behavior: A novel assessment framework

Residential demand flexibility (DF) could save the U.S. electric grid up to 10 GW of peak demand while supporting increased amounts of renewable generation. However, less than 40% of the estimated DF peak reduction capacity is currently realized, and less than 8% of American households are enrolled. These low participation rates are combined with high rates of "overriding" a DF event and eventual opt-outs among enrolled customers. There is still not a comprehensive understanding of the drivers of DF participation and occupant interaction with DF program signals. We, therefore, present a novel survey processing framework to assess occupant DF-relevant behavior from the American Time Use Survey (ATUS). Using the framework, we summarize both the extensive and intensive behavior of more than 200,000 ATUS respondents (2003-2018 data) and provide insights on the DF-relevant behavior of residential occupants, which is generally overlooked in the literature. Here we use the framework to identify the activity priorities of residential occupants in the United States during different DF-relevant periods (critical peak, peak, and off-peak). These preferred activities capture overlooked routine behaviors that could be barriers to DF participation, if ignored, and might explain the high levels of overrides often exhibited by participants of demand response.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimal Operation and Impact Assessment of Distributed Wind for Improving Efficiency and Resilience of Rural Electricity Systems

This project aims to empower rural utilities by developing advanced optimization models and algorithms for effectively integrating distributed wind energy alongside battery storage and other distributed energy resources (DERs). The primary objectives are to reduce peak demand, ensure reliable emergency power supply, and regulate voltage and frequency. To address operational challenges, the project introduces innovative mitigation strategies and ultrafast assessment frameworks to evaluate the impacts of distributed wind and DERs on rural grids, offering actionable solutions to potential issues. Economic viability is assessed through cost-benefit analysis using real rural utility data, ensuring the practical application of the project outcomes.

17 WIND ENERGY↗

Friction Stir Dovetailing of AA7099 to Steel with AA6061 Interlayer for Reduced Zn Embrittlement at Dissimilar Interface

Joining of high strength Al alloy (AA7099) to steel (rolled homogeneous armor) with and without AA6061 interlayer was achieved using a friction stir dovetailing (FSD) method. Detailed investigations were conducted to establish correlations between mechanical performance and microstructural evolution of FSD joints. Lap shear tensile testing revealed that incorporation of the AA6061 interlayer combined with tailored processing methodology significantly improved both mechanical interlocking and load transmission across the dovetail interface. Following incorporation of the interlayer, the maximum load carrying capacity and peak extension (of the AA7099/AA6061/steel joint) are 60% and 210% higher, respectively, than results obtained from an AA7099/steel joint without an interlayer. Without an AA6061 interlayer, formation of zinc rich intermetallic compounds led to brittle interfacial failure of the AA7099-steel FSD joint. Incorporation of novel tool and joint configuration eliminated asymmetric joint performance as a function of loading direction, which is generally observed in friction stir lap welding. The efficacy of the use of an AA6061 interlayer in joining AA7099 to steel was demonstrated through mechanical testing as well as high resolution analytical electron microscopy characterization.

Dissimilar metal joining, Friction stir dovetailin↗

Developing and Evaluating Metrics for Demand Flexibility in Buildings: Comparing Simulations and Field Data

Building demand flexibility (DF) has attracted significant attention in recent years among researchers, technology developers and control companies, aggregators, utilities, and many others. There are numerous challenges with today’s electricity systems such as managing peak demand capacity and integrating variable renewables into the grid. Flexible building loads can provide various grid services to help reduce electricity costs, smooth out renewables intermittency and balance supply and demand. Recognizing this, the US DOE is leading the Grid-interactive Efficient Buildings (GEB) initiative which includes research to evaluate the potential, availability and timing of flexible loads. In this paper we present load shed metrics for three building types – medium office, large office and retail store – and compare prototype simulation results with measured data from 12 actual buildings that participated in hot summertime utility demand response (DR) events. The DR strategies included varying zone temperature and reducing light levels. The magnitude of a key DF metric, “demand decrease intensity” (or “shed intensity”) (W/ft2), between the simulation results and field data are similar (14-32% differences) for both mean and median values, though the field data show much larger variation among DR events. The coefficient p-values from linear regression model tests showed that outside air temperature is a significant variable for the whole building shed intensity when the resetting zone temperature strategy is deployed. These findings support the concept of using prototype building simulation to estimate building DF and expanding future simulation research to additional building types and climate zones.

Liu, Jingjing↗

Bridging Cloud and Edge Computing at NREL Using CONNECT: Cloud Optimized Networking for Next-Gen Edge Computing Technologies [Slides]

CONNECT is an innovative on-premise hardware and software solution that integrates edge and cloud computing infrastructure at NREL. Built on the AWS Greengrass middleware and leveraging the MQTT protocol, CONNECT enables real-time data streaming from IoT devices and gateways to both cloud and local services, empowering researchers to rapidly capture, analyze, and act upon edge-generated data while leveraging cloud capabilities. The platform addresses research infrastructure challenges by providing a pre-approved platform which is already configured with the correct networking and cybersecurity baselines thus eliminating procurement delays and enabling on-demand availability. CONNECT's hybrid architecture efficiently manages burstable workloads, allowing research teams to dynamically scale computational capacity, handle peak data loads, and reduce operational bottlenecks. Advanced capabilities include built-in GPU support for executing machine learning models which enables low-latency inference at the edge from models trained in the cloud. This architecture supports real-time analytics and filtering, providing a mechanism to allow only transmitting and processing high-value data. Cloud-based configuration management permits engineers to manage on-premise systems remotely, optimizing operational efficiency. By bridging edge and cloud computing, CONNECT provides NREL researchers with a flexible, scalable platform that accelerates scientific discovery while maintaining robust security and performance standards.

97 MATHEMATICS AND COMPUTING↗

A hub and spoke approach to optimizing energy wheeling of renewable resources

The deployment of zero carbon renewable energy sources needs to increase significantly to support the goal of net zero greenhouse gas emissions by 2050. At the same time energy end use needs to decarbonize. This will change both energy supply and energy demand patterns, requiring the energy delivery infrastructure (grid-based transmission circuits) to become increasingly flexible to maintain security of supply everywhere and always. The integration of zero carbon renewable energy requires cross-border and cross energy system coupling and a fit-for-purpose design. Nowadays, energy systems are planned, designed and operated in silos with a strong national focus. However, large-scale offshore wind production needs to be transported to deep inland locations, across country borders. The increased peak generation capacity of renewable energy sources will, at times, significantly exceed demand (Matthew Langholtz, 2020). The traditional solution of continuously reinforcing and extending the electricity grid is not sustainable from a cost and societal perspective. This paper will, however, propose a deterministic approach on how networked (interconnected grid) Points of receipt (POR) to Points of Delivery (POD) can be optimized for wheeling renewable energy resources while minimizing energy cost with a hub and spoke approach. The statistical approach will be done via using existing daily energy market clearing prices, available transmission capacity and firm daily transmission prices in open access energy markets. Renewable energy targets, including specific offshore wind targets, need to be in line with the ramp-up as implied by the Paris Agreement. These targets are required to provide industry with a secure market outlook that allows them to build up supply chains accordingly. Optimizing wheeled energy paths from carbon neutral resources such as renewables make them not only cost competitive on the unit commitment stack, but also more accessible on the dispatch stack to other carbon heavy forms of generation such as coal and natural gas turbines (Matthew Langholtz, 2020). This correlates to maximizing renewable resource inertia (wind, solar, biomass) within an interconnected grid without having to consider additional expansion of resources via land purchases and de-forestation.

Mukherjee, Srijib↗

Magnetic behavior of manganese chloride on Kagome and honeycomb lattices

The magnetic properties of transparent pink Na 2 Mn 3 Cl 8 and NaMnCl3 are presented. For both phases, the effective magnetic moments are large, while the Curie-Weiss thetas are below 10 K. The compounds crystallize in the trigonal R-3m and R-3 space groups, respectively. A Kagome plane of Mn 2+ octahedrally coordinated to Cl- is found in Na 2 Mn 3 Cl 8 and the material has no apparent magnetic ordering above 1.8 K, while the octahedrally coordinated, honeycomb network of Mn 2+ in NaMnCl 3 orders antiferromagnetically at 6.3 ± 0.2 K. The heat capacity of NaMnCl3 has one transition, consistent with the susceptibility, while Na 2 Mn 3 Cl 8 exhibits a more complex heat capacity with two peaks, at 0.6 K and 1.4 K. A third, broad peak near 6.2 K in the heat capacity of Na 2 Mn 3 Cl 8 is problematic but may be due to the intergrowth of NaMnCl 3 domains.

36 MATERIALS SCIENCE↗

Cost-Optimized Cold Climate Heat Pump Development and Field Test

Cold climate heat pumps (CCHPs) expand the heat pump market to climates where heating demand is dominant. They can achieve more than 70% energy savings compared with electric resistance heating and operate at lower cost than using tank-stored propane to fuel a furnace. A high-efficiency heat pump with a heating seasonal performance factor (HSPF)—as defined by the Air-Conditioning, Heating, and Refrigeration Institute (AHRI 2008)—greater than 10.0 would be more efficient than gas heating in terms of source energy. However, developing a cost-effective CCHP involves some challenges. A typical single-speed, air-source heat pump (ASHP) with an HSPF of 7.7 Btu/Wh does not work well under cold outdoor temperature conditions typical of cold climate locations for four major reasons: 1. Discharge temperature is too high—The low suction pressure and high compression pressure ratio at low ambient temperatures causes high compressor discharge temperatures in excess of the maximum limit for many of the compressors on the market. Furthermore, system charge of a heat pump is usually optimized in the cooling mode, which leads to overcharge conditions in the heating mode, further increasing the discharge temperature. 2. Heating capacity is insufficient if sized to meet the building design cooling load— Heating capacity of a single-speed heat pump decreases with ambient temperature. The heating capacity at -13°F (-25°C) typically decreases to 20%–40% of the rated heating capacity at 47°F (8.3°C) (~equivalent to the rated cooling capacity at 95°F [35°C]). Therefore, a single-speed heat pump, typically sized to match the building design cooling load, cannot provide adequate heating capacity to match the building heating load at low ambient temperatures. The capacity deficit is filled by inefficient resistance heat, thus lowering the system efficiency and significantly increasing power demand. 3. Cyclic loss is significant if sized to meet the building design heating load—If a single-speed heat pump is sized to meet the heating load, it will be significantly oversized relative to the cooling load in many cold climates. This will cause excessive on/off cyclic loss during the cooling and heating operations at moderately low ambient temperatures. Thus, capacity modulation capability (e.g., using a variable-speed or multi-stage compressor) is necessary for a CCHP, which uses its full capacity to meet the peak heating load and partial capacity to meet the cooling and part-load heating loads. 4. Coefficient of performance (COP) is low—Heating COP degrades significantly at low ambient temperatures owing to the large temperature difference between the heat source and sink. A target CCHP should be sized to meet the building design heating load while minimizing the cyclic loss for the cooling and heating operations at moderate ambient temperatures.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Redesigning capacity market to include flexibility via ramp constraints in high-renewable penetrated system

Capacity markets can co-exist alongside the energy and ancillary markets to ensure the medium-term and long-term supply adequacy by remunerating the generation resources for their availability. With the substantially increasing deployment of renewable generation, the system needs more flexibility to quickly mitigate the variability and uncertainty caused by the renewable generation. However, the present capacity market model does not differentiate the flexibility of generating units, so it might not give appropriate pricing signals to more flexible units that are usually more expensive. This is particularly important considering the increasing penetration levels of renewable generation on the electric grid, which increases the need for flexible units. This paper proposes a novel capacity market model considering flexibility requirement (FR) under the high penetration levels of renewable generation. Therefore, the proposed model can give the market-clearing price (MCP) for not only peak load generation capacity but also flexibility requirement. Thus, flexible units will tend to receive more economic incentives than non-flexible units. In the case studies, the profitability of different generation resources under the proposed capacity market model is analyzed and compared to the present capacity market model. The results show that the proposed method can maintain system reliability with regard to both peak load and flexibility requirement efficiently.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Effects of Climate Change on Capacity Expansion Decisions of an Electricity Generation Fleet in the Southeast U.S.

The electric power sector in the United States faces many challenges related to climate change. On the demand side, climate change could shift demand patterns due to increased air temperatures. On the supply side, climate change could lead to deratings of thermal units due to changes in air temperature, water temperature, and water availability. Past studies have typically analyzed these risks separately. Here, we developed an integrated, multimodel framework to analyze how compounding risks of climate-change impacts on demand and supply affect long-term planning decisions in the power system. In the southeast U.S., we found that compounding climate-change impacts could result in a 35% increase in installed capacity by 2050 relative to the reference case. Participation of renewables, particularly solar, in the fleet increased, driven mostly by the expected increase in summertime peak demand. Such capacity requirements would increase investment costs by approximately 31 billion (USD 2015) over the next 30 years, compared to the reference case. These changes in investment decisions align with carbon emission mitigation strategies, highlighting how adaptation and mitigation strategies can converge.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Probing Hawking radiation through capacity of entanglement

We consider the capacity of entanglement in models related with the gravitational phase transitions. The capacity is labeled by the replica parameter which plays a similar role to the inverse temperature in thermodynamics. In the end of the world brane model of a radiating black hole the capacity has a peak around the Page time indicating the phase transition between replica wormhole geometries of different types of topology. Similarly, in a moving mirror model describing Hawking radiation the capacity typically shows a discontinuity when the dominant saddle switches between two phases, which can be seen as a formation of island regions. In either case we find the capacity can be an invaluable diagnostic for a black hole evaporation process.

2D gravity↗

Investigations into the Ternary NaF-KF-UF4 Salt System – Phase A

A knowledge gap exists in the data and understanding of fresh fuel salt and irradiated multicomponent fuel salt systems thermophysical properties. Quantifying these properties is necessary for the design and construction of test reactors, as well as the licensing of future commercial molten-salt reactors. To facilitate thermal property determination on a proposed fuel salt composition for Seaborg Technologies, several samples containing depleted uranium tetrafluoride (UF4), sodium fluoride (NaF), and potassium fluoride (KF) were blended, and a melt temperature analysis was performed. From the melting temperature analysis, it was determined that sample Seaborg-7, a ternary salt composition of 26.4UF4-24.7KF-48.9NaF (mol%), was very near a ternary eutectic point. Therefore, thermal properties such as melting temperature, salt stability, density, heat capacity, thermal diffusivity, and viscosity were experimentally determined on the Seaborg-7 salt. These measurements document the baseline properties of fresh fuel salt as a function of temperature, where future experiments on irradiated fuel salt will provide a holistic perspective on the change of thermophysical properties during reactor operations. Several precision instruments were used to collect property data, and instrument calibrations and data collection were performed and documented in a standardized and reproducible manner with meticulous detail. This process ensured that the measurement procedures and resulting data can readily be duplicated elsewhere. The Seaborg-7 salt was shown to be stable at temperatures up to 900°C, as no mass change was observed upon repeated heating and cooling. The peak melting temperature was determined to be 547°C (557°C endset). The enthalpy of fusion (??H?_fus^o) was determined to be 167.5 ± 2.7 J/g while the enthalpy of crystallization (??H?_c^o) was determined to be -147.8 ± 13.3 J/g. In addition to the eutectic melting peak, upon heating, several pre eutectic peaks were observed, occurring at 470°C (onset) and 499°C (peak). Specific heat capacity measurements showed a slightly increasing trend with respect to temperature in the solid phase, while the liquid-specific heat capacity showed a somewhat flat trend with an average value of 106.1 ± 1.24 J/mol·K between 600 to 800°C. Three independent trials using the Seaborg-7 salt determined the density to be ?(T) = 4.908 – 0.000363·T(°C), validated between 32 to 200°C, and ?(T) = 4.808 – 0.00113·T(°C), validated between ~575 to 850°C. Thermal diffusivity was determined for the liquid state and is represented by the linear equation y = 0.1581 + 0.000207·T(°C) between 550 to 850°C. The viscosity was determined from 600 to 800°C and is represented by the exponential fit equation, ? (mPa·s) = 736.58e^(-0.006·T(°C)). This report documents the conclusion of fuel salt thermophysical property measurements for the Seaborg SPP, Phase A project.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗