At least 37 records · Page 2

Passive Temperature Sensors for Nuclear Applications

In April 2007, the Department of Energy (DOE) designated the Advanced Test Reactor (ATR) a National Scientific User Facility (NSUF) to advance US leadership in nuclear science and technology. By attracting new users from universities, laboratories, and industry, this program supports basic and applied nuclear research to help address the nation's energy security needs. In support of this program, the Idaho National Laboratory (INL) established in-house capabilities to develop, fabricate, test, and qualify new and enhanced temperature sensors for irradiation testing. This effort is continuing today through the DOE?s Advanced Sensors and Instrumentation (ASI) program. Although most efforts emphasize sensors capable of providing real-time data, selected tasks have been completed to enhance passive sensors for irradiations where instrumentation leads cannot be included. These sensors include silicon carbide (SiC) monitors, melt wires and the sublime temperature monitor. SiC monitors are available to detect peak irradiation temperatures between 200°C and 800°C in reactor locations where instrumentation leads cannot be used. SiC monitors may be evaluated using specialized equipment installed at INL?s Measurement Sciences Laboratory (MSL). A melt wire inventory is also maintained at MSL. This inventory contains wires for specific use in irradiation experiments ranging in temperatures from 30°C to 1500°C. Melt wires and SiC monitors have had decades of research and application. Recent research has produced a passive monitor known as the sublime temperature monitor. This passive sensor has the capability of recording temperature gradients. This paper will discuss passive temperature sensors currently being researched and implemented under the ASI program.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A Piezoelectric Passive Wireless Sensor for Monitoring Strain

Interest in passive wireless sensing has grown over the past few decades to meet demands in structural health monitoring.(Deivasigamani et al., 2013; Wilson and Juarez, 2014) This work describes a passive wireless sensor for monitoring strain, which does not have an embedded battery or chip. Without an embedded battery, the passive wireless sensor has the potential to maintain its functionality over long periods in remote/harsh environments. This work also focuses on monitoring small strain (less than 1000 micro-ɛ). The wireless sensing system includes a reader unit, a coil-like transponder, and a sensing unit. It operates in the Megahertz (MHz) frequency range, which allows for a few centimeters of separation between the reader and sensing unit during measurements. The sensing unit is a strain-sensitive piezoelectric resonator that maximizes the energy efficiency at the resonance frequency, so it converts nanoscale mechanical variations to detectable differences in electrical signal. In response to an external loading, the piezoelectric sensor breaks from its original electromechanical equilibrium, and the resonant frequency shifts as the system reaches a new balanced equilibrium. In this work, the fixture of the sensing unit is a small, sticker-like package that converts the surface strain of a test material to measurable shifts in resonant frequencies. Furthermore, electromechanical modeling provides a lumped-parameter model of the system to describe and predict the measured wireless signals of the sensor. Detailed characterization demonstrates how this wireless sensor has resolution comparable to that of conventional wired strain sensors for monitoring small strain.

Zou, Xiyue↗

Emerging Needs for Pervasive Passive Wireless Sensor Networks on Aerospace Vehicles

NASA is investigating passive wireless sensor technology to reduce instrumentation mass and volume in ground testing, air flight, and space exploration applications. Vehicle health monitoring systems (VHMS) are desired on all aerospace programs to ensure the safety of the crew and the vehicles. Pervasive passive wireless sensor networks facilitate VHMS on aerospace vehicles. Future wireless sensor networks on board aerospace vehicles will be heterogeneous and will require active and passive network systems. Since much has been published on active wireless sensor networks, this work will focus on the need for passive wireless sensor networks on aerospace vehicles. Several passive wireless technologies such as microelectromechanical systems MEMS, SAW, backscatter, and chipless RFID techniques, have all shown potential to meet the pervasive sensing needs for aerospace VHMS applications. A SAW VHMS application will be presented. In addition, application areas including ground testing, hypersonic aircraft and spacecraft will be explored along with some of the harsh environments found in aerospace applications.

Wilson, William C.↗

Passive Temperature Sensors for Nuclear Applications

Thermocouples are generally used to provide real-time temperature indications in instrumented tests performed at material and test reactors. Passive temperature monitors, such as Silicon Carbide (SiC) and melt wires, may be included in such tests as an independent technique of detecting peak temperatures experienced during irradiation. In less expensive static (drop-in) capsule tests, which have no leads attached for real-time data transmission, melt wires, and SiC temperature monitors (TMs) are essentially the only possibility for peak temperature indication. A melt wire involves placing materials (wires) of a known composition and melting temperature in a test. An inventory is maintained at Material Science Laboratory (MSL) for melt wires ranging in temperatures from 30°C to 1500°C. Unfortunately, melt wires are limited in that it can only detect whether a single temperature is or is not exceeded (melt wire melted or not). SiC TMs, which can also be used to detect peak irradiation temperatures, are advantageous because a single monitor can allow to determine the peak temperature reached within a relatively broad range (100 – 1200°C) resulting in accuracies within ±20°C. Irradiation temperature is determined by measuring a property change after isochronal annealing or during a continuously monitored annealing process using specialized equipment at MSL. Recent research has produced a passive monitor known as sublime temperature monitor. This passive sensor has the capability of recording temperature gradients and pinpointing exactly where a temperature is located along that gradient. Long measurement lengths are achieved with very high accuracy in the location of desired temperature measurements (±2 mm over a 1 m span); however, this sensor has not been deployed in a nuclear reactor. This article will focus only on passive temperature sensors currently being researched and implemented under the Advanced Sensors and Instrumentation (ASI) program at Idaho National Laboratory (INL).

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Passive fetal monitoring sensor

An ambulatory, passive sensor for use in a fetal monitoring system is discussed. The invention is comprised of a piezoelectric polymer film, combined with a metallic mounting plate fastened to a belt, and electrically connected to a signal processing unit by means of a shielded cable. The purpose of the sensor is to receive pressure pulses emitted by a fetus inside an expectant mother. Additionally, the monitor will filter out pressure pulses arising from other sources, such as the maternal heart.

Zuckerwar, Allan J.↗

AOI [1]: Passive Wireless Sensor Systems Fabricated by Direct-Writing for Temperature and Health Monitoring of Energy Systems in Harsh-Environments (Final Report)

Researchers at West Virginia University (WVU) propose to demonstrate a wireless, high-temperature sensor system for monitoring the temperature and health of energy-system components. The active sensor and electronics for wireless communication will be composed entirely of an electroceramic materials (conductive ceramics) which are capable of withstanding the harsh-environments required for fossil energy-based technologies. This work will focus primarily on the fabrication and testing of temperature (thermocouples and thermistors) and health (strain/stress and crack propagation sensors) that function at extreme temperatures (up to 700-1700ºC). The electronics will accompany the high-temperature sensor, which will include a passive wireless communication circuit that allows the transmission of the data based on the LCR resonance principle to a near-by reader antenna. This passive transmission of data will reduce the need for interconnect wires near the active, and possibly rotating, energy-system component. The research will include process development to permit the 2D/3D direct-writing of the entire sensor and communication circuit onto the energy-system component. The direct-writing will be facilitated by using silicon-based polymer-derived precursors to form the high-temperature, stable electroceramic compositions. In addition, methods for direct-writing the circuit onto a fugitive carrier substrate will be completed, which will permit a “peel-and-stick”-like transfer of the sensor circuit to the energy-system component. This feature will allow the economical and precise placement of the sensor circuit onto components of various shapes and locations, without altering the geometry and active features of the manufactured component, or the removal (or decommissioning) of the component for installation. The proposed work will be directed at the following areas: 1) Investigation of phase formation, sintering/grain growth, and electrical properties of polymer-derived electroceramic composites; 2) Definition of processes to direct-write through ink-jet and robo-casting the polymer-derived electroceramic composites onto oxide and polymer surfaces; 3) Development of methods to form monolithic "peel-and-stick" preforms that will efficiently transfer the sensor circuit to ceramic surfaces after thermal treatment; 4) Design of passive wireless LCR circuits and receiver (reader) antennas for communication and testing at high temperatures; 5) Investigation of the passive wireless sensor system developed (and method of transferring sensor system) for temperature and stress/strain measurements on a SOFC repeat unit and a singular gas turbine blade prototype as example applications.

01 COAL, LIGNITE, AND PEAT↗

Passive Wireless Sensors for Realtime Temperature and Corrosion Monitoring of Coal Boiler Components Under Flexible Operation (Final Technical Report)

Researchers at West Virginia University (WVU) propose to demonstrate inexpensive wireless, high-temperature sensors for real-time monitoring of the temperature and corrosion of metal components, which are commonly used in coal-fired boilers. This study presents the development of cost-effective wireless high-temperature sensors for real-time temperature and corrosion monitoring in coal-fired boilers' metal components. The focus is on fabricating and evaluating chipless radio-frequency identification (RFID) sensors capable of operating between 25-1300 ºC. Efforts were directed towards designing passive RFID sensor and interrogator antenna with a broad frequency range, optimizing a microstrip patch antenna sensor integrated into a "peel-and-stick" format for efficient application to various metal specimens without altering their geometry. Additionally, this research aimed to assess the sensor responses under accelerated high-temperature conditions, correlating corrosion and cracking mechanisms with sensor data. An investigation of through-wall data acquisition techniques was also planned, facilitating unobtrusive monitoring of sensor responses housed within metal enclosures. Ultimately, this work sought to establish a robust passive wireless sensor system for the continuous health monitoring of metal components in operational settings, thereby contributing to enhanced safety and efficiency in coal-fired power plants.

20 FOSSIL-FUELED POWER PLANTS↗

Near-Field Passive Wireless Sensor for High-Temperature Metal Corrosion Monitoring

This work focuses on the fabrication and evaluation of a passive wireless sensor for the monitoring of the temperature and corrosion of a metal material at high temperatures. An inductor–capacitor (LC) resonator sensor was fabricated through the screen printing of Ag-based inks on dense polycrystalline Al 2 O 3 substrates. The LC design was modeled using the ANSYS HFSS modeling package, with the LC passive wireless sensors operating at frequencies from 70 to 100 MHz. The wireless response of the LC was interrogated and received by a radio frequency signal generator and spectrum analyzer at temperatures from 50 to 800 °C in real time. The corrosion kinetics of the Cu 110 was characterized through thermogravimetric (TGA) analysis and microscopy images, and the oxide thickness growth was then correlated to the wireless sensor signal under isothermal conditions at 800 °C. The results showed that the wireless signal was consistent with the corrosion kinetics and temperature, indicating that these two characteristics can be further deconvoluted in the future. In addition, the sensor also showed a magnitude- and frequency-dependent response to crack/spallation events in the oxide corrosion layer, permitting the in situ wireless identification of these catastrophic events on the metal surface at high temperatures.

36 MATERIALS SCIENCE↗

Satellite-Assisted Particulate Matter (SAPM) for the Models, In situ, and Remote Sensing of Aerosols (MIRA) Working Group

Models, In situ, and Remote sensing of Aerosols (MIRA) is an international working group that provides a forum for collaborations amongst these three atmospheric aerosol communities. MIRA consists of a collection of interdisciplinary and independently funded Topic/Project groups with clear goals and generally characterized by requests for additional scientific data. The Satellite-Assisted Particulate Matter (SAPM) Topic group focuses on the study of fine particulate matter (PM2.5), as it is a major contributor to air pollution and negatively impacts human health. Our group aims to provide intercomparisons of various methods and techniques for estimating surface PM2.5 assisted by satellite remote sensors (passive and active), global aerosol models, and in situ aerosol measurements. The overall motivation of our work is to enhance PM2.5 coverage beyond in situ ground stations, which can be limited. In this presentation, we provide an overview of various PM2.5 estimation approaches by current SAPM team members, as each approach has its own strengths and limitations. One approach uses near-surface aerosol extinction retrievals from the spaceborne Cloud-Aerosol Lidar with Orthogonal Polarization (CALIOP) and an assumed value of mass extinction efficiency to derive PM2.5 concentrations (Toth et al 2019). A study using this method found a promising agreement (R=0.60; slope=0.89) with U.S. Environmental Protection Agency (EPA) in situ PM2.5 measurements over the contiguous United States (CONUS) for a 12-year (2007-2018) period (Toth et al 2022). In a different approach combining spaceborne lidar and a model, the Cloud Aerosol Transport System (CATS) lidar and Goddard Earth Observing System (GEOS) model are blended in an ensemble variational assimilation scheme to retrieve aerosol extinction and convert speciated mass concentrations to total PM2.5. A recent study (Matus et al in prep.) found agreement within 2 μg/m3 over the CONUS on the 2016 annual mean when compared to EPA ground-based measurements. Another study explored trends in city aerosol optical depth (AOD) from a spaceborne passive remote sensor, Moderate Resolution Imaging Spectroradiometer (MODIS), and found that these trends agree well with trends in city surface PM2.5, which provides confidence in the use of city AOD for city PM2.5 trend studies (Vohra et al 2021). In a follow-on study, steep and significant trends (~2.5 to 7.8% a-1) in AOD are found for several South Asian cities (e.g., Bangalore and Hyderabad), suggesting rapid growth in PM2.5 (Vohra et al 2022). Also in this presentation, we report results on our current collective SAPM study of India, a country that exhibits high levels of PM2.5 pollution. We show the temporal (i.e., seasonal) and spatial variability of PM2.5 over India using the CALIOP and CATS+model approaches, comparisons between the estimated PM2.5 from the retrieval schemes, and validation with in situ PM2.5 ground-based observations from the Central Pollution Control Board in India. This region provides us with an excellent case study to test our PM2.5 retrievals in heavily polluted scenes and over a complex and varying topography. The SAPM Topic group actively seeks international participants/collaborators in our group, including those working with in situ aerosol measurements (e.g., ACTRIS). We are interested in aerosol datasets in order to either improve our PM2.5 estimates from various approaches (e.g., using in situ mass scattering/absorption coefficient and aerosol hygroscopic properties for various aerosol species) and/or validate the PM2.5 estimates (e.g., using in situ ground-based PM2.5 concentrations).

Travis D Toth↗

Sensors for passively measuring a maximum temperature of a nuclear reactor, and related methods

A sensor for passively measuring a maximum temperature within a nuclear reactor comprises a substrate, and a plurality of melt wires within a cavity defined within the substrate, at least one melt wire of the plurality of melt wires exhibiting a variable melting temperature along a length of the at least one melt wire. Related sensors and methods of forming the sensors are also disclosed.

Daw, Joshua↗

Silicon Carbide Passive Temperature Sensors at INL

Discuss the SiC passive thermometry methods currently performed at INL and ORNL, decide on best path forward for establishing an ASTM Standard for processing SiC temperature monitors, and expand this ASTM benchmarking efforts to international collaborators (Netherlands, Canada, and Poland).

36 MATERIALS SCIENCE↗

A multifrequency evaluation of active and passive microwave sensors for oil spill detection and assessment

An evaluation is given of how active and passive microwave sensors can best be used in oil spill detection and assessment. Radar backscatter curves taken over oil spills are presented and their effect on synthetic aperture radar (SAR) imagery are discussed. Plots of microwave radiometric brightness variations over oil spills are presented and discussed. Recommendations as to how to select the best combination of frequency, viewing angle, and sensor type for evaluation of various aspects of oil spills are also discussed.

Fenner, R. G.↗

Wireless Passive Ceramic Sensor for Far-Field Temperature Measurement at High Temperatures

A passive wireless high-temperature sensor for far-field applications was developed for stable temperature sensing up to 1000 °C. The goal is to leverage the properties of electroceramic materials, including adequate electrical conductivity, high-temperature resilience, and chemical stability in harsh environments. Initial sensors were fabricated using Ag for operation to 600 °C to achieve a baseline understanding of temperature sensing principles using patch antenna designs. Fabrication then followed with higher temperature sensors made from (In, Sn) O2 (ITO) for evaluation up to 1000 °C. A patch antenna was modeled in ANSYS HFSS to operate in a high-frequency region (2.5–3.5 GHz) within a 50 × 50 mm2 confined geometric area using characteristic material properties. The sensor was fabricated on Al2O3 using screen printing methods and then sintered at 700 °C for Ag and 1200 °C for ITO in an ambient atmosphere. Sensors were evaluated at 600 °C for Ag and 1000 °C for ITO and analyzed at set interrogating distances up to 0.75 m using ultra-wideband slot antennas to collect scattering parameters. The sensitivity (average change in resonant frequency with respect to temperature) from 50 to 1000 °C was between 22 and 62 kHz/°C which decreased as interrogating distances reached 0.75 m.

47 OTHER INSTRUMENTATION↗

All-Digital Plug and Play Passive RFID Sensors for Energy Efficient Building Control

This is the final report for the project “All-Digital Plug and Play Passive RFID Sensors for Energy Efficient Building Control”, funded by DOE, and performed by Clemson University, Phase IV Engineering and Harvard University from October 1, 2016 to December 31, 2020. The main objective of this project is to develop, demonstrate and pre-commercialize a novel, plug & play, battery-free, wireless sensor technology to enable low-cost (<$10 per node) indoor and outdoor temperature and humidity measurement for energy efficient building controls and operations. The proposed technology is based on the novel concept of all-digital sensing and its seamless integration with the passive RFID technology. This project focuses on the design, fabrication, material optimization, interrogation electronics, validation, and demonstration of the novel sensor nodes for building applications. The specific objectives of this research program include: (1) Design, fabricate and optimize a compact, robust, and high-resolution digitizer, which could convert rotation angle into digital numbers. (2) Develop the multi-physics-based modeling and simulation of the temperature/humidity transducer to derive a rational design of the architecture, dimension, structure, materials (i.e., mechanical, electrical, thermal and hygroscopic) properties and functions of the sensor node. (3) Design, fabricate and optimize the bi-material based humidity sensitive coil which could linearly transduce the environmental relative humidity variations to rotation angles. (4) Design, fabricate and optimize an UHF RFID platform which could support long-range passive wireless communications of 8-bit digital numbers. (5) Design, fabricate and optimize the miniaturized all-digital sensor using MEMS technology. (6) Validate the integrated all-digital sensing system in a real building environment to test the system’s performance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗