Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “passive cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Membrane Adsorbents Comprising Self-Assembled Inorganic Nanocages (SINCs) for Super-fast Direct Air Capture Enabled by Passive Cooling

The objectives of the proposed project were to develop highly porous membrane adsorbents comprising CO 2 -philic polymers and self-assembled inorganic nanocages (SINCs) for rapid temperature swing adsorption using electricity-free solar heating and radiative cooling, enabling an economically viable approach for direct air capture (DAC). Our core technical activities combine three key innovations. (1) Highly porous flat-sheet membrane adsorbents contain CO 2 -philic amines that can be easily produced using a phase inversion method. (2) CO 2 -philic SINCs can be easily dispersed in the polymers with great stability (compared with the metal-organic frameworks or MOFs). (3) The adsorption and desorption are integrated with solar heating and radiative cooling for rapid continuous operation, in contrast to traditional long-cycle separate operation. The membrane adsorbents containing amines, polymers, and SINCs were produced using a one-step industrial process. The porous membranes coupled with porous SINCs offer low resistance for gas flow and fast CO 2 sorption/desorption cycles, while the incorporation of the additional amine groups provides high CO 2 sorption capacity. The key achievements are summarized below. (1) Membrane adsorbents with high PEI loading (>40%), high porosity of >80%, and low gasflow resistance were prepared in one step using commercially available, low-cost materials. (2) Membrane adsorbents based on Solupor and PEI show CO 2 sorption capacity of >1.5 mmol/g using air containing 400 ppm at a relative humidity of 15%. (3) Effect of the adsorbent compositions (such as PEI type, PEI content, SINC content, porosity) on the CO 2 sorption was systematically investigated. (4) Effect of the processing conditions (such as CO 2 content, temperature, and relative humidity) on the CO 2 sorption was systematically investigated; (5) The stability of the membrane adsorption against many cycles of sorption and desorption was studied. The higher molecular weight of PEI (PEI25k) shows better stability than PEI800. (6) Advanced materials with radiative cooling were developed, which can decrease the temperature by 5-7 °C compared to the ambient temperature. (7) Preliminary techno-economic analysis shows that our process may achieve a capture cost of $1,343/tonne CO 2 with a total OPEX cost of $1,112/tonne CO 2 . The adsorbent replacement cost accounted for 52% of the total OPEX cost. Membrane adsorbents with lower costs and longer operation life can significantly decrease the cost. The proposed project directly addresses the requirement of DE-FOA-0002188, i.e., novel materials with CO 2 adsorption capacity for direct air capture with integrated solar heating and radiative cooling to reduce the cost of the DAC. Our future work will focus on the development of low-cost adsorbents that can be stable at the sorption and desorption conditions for long term.

14 SOLAR ENERGY↗

Passively cooled glass CO2 laser tubes for severe environments

The objective of this effort was to design a glass CO2 laser tube that could survive the Titan 3 C launch environment and at the same time provide adequate thermal conductivity to maintain the wall of the laser tube below approximately equal to 50 C for efficient lasing. The approach that was taken to satisfy these requirements was to pot the tube in an aluminum heat sink using a space qualified polyurethane potting material. Two configurations of the laser tube successfully passed the complete Titan 3 C qualification level sine and random vibration specification and satisfied the thermal requirements. Fabrication details and test results are presented that indicate this could be a practical solution for laser tubes used in a severe environment and where flowing coolants are impractical or undesirable.

Walker, H. E.↗

The multistage heat pipe radiator - An advancement in passive cooling technology

Mathematical models were developed for one-, two-, and three-stage radiator systems to determine optimum stage areas and system performance as a function of such parameters as insulation effectiveness, cold stage temperature, and heat load to the cold and intermediate stages. This study shows that multistage radiator systems can be optimized on the basis of weight or projected area, and that cold stage temperatures as low as 15 K are theoretically possible with present technology levels for insulation emittance. For the baseline design, analyses were performed to determine optimum radiator fin geometry and heat pipe spacing as a function of temperature, material properties, and heat pipe weight. In addition, a ground test system was designed for the baseline design with heat rejection requirements of 10 MW at 35 K on the cold stage and 100 MW at the second stage.

Wilson, D. E.↗

A Monolithic 2k x 2k LWIR HgCdTe Detector Array for Passively Cooled Space Missions

A 2K x 2K 10 µm cutoff HgCdTe array for background-limited space astronomy has been developed by Teledyne Imaging Sensors to specifications set by JPL, and demonstrated by University of Rochester at a focal plane temperature of 40K for the proposed JPL Near-Earth Object Camera (NEOCam) survey mission under the NASA Planetary Defense Coordination Office. We describe the detector performance for the first large format monolithic HgCdTe detector array tested, including the dark current, well depth, dark current vs. temperature, quantum efficiency, latent image performance, and read noise.

Pan, Jianmei↗

A Monolithic 2k x 2k LWIR HgCdTe Detector Array for Passively Cooled Space Missions

A 2K x 2K 10 µm cutoff HgCdTe array for background-limited space astronomy has been developed by Teledyne Imaging Sensors to specifications set by JPL, and demonstrated by University of Rochester at a focal plane temperature of 40K for the proposed JPL Near-Earth Object Camera (NEOCam) survey mission under the NASA Planetary Defense Coordination Office. We describe the detector performance for the first large format monolithic HgCdTe detector array tested, including the dark current, well depth, dark current vs. temperature, quantum efficiency, latent image performance, and read noise.

Pan, Jianmei↗

Coating to cool a surface by passive radiative cooling

Disclosed herein in is a radiative cooling formulation comprising a first component with >55% reflectance in a wavelengths range of 0.3 to 2.5 microns, a second component with >0.85 peak thermal emissivity in a window range of 4 to 35 microns, and a third component to mechanically bind together a mixture of the first and second components.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Coating to cool a surface by passive radiative cooling

Disclosed herein in is a radiative cooling formulation including a first component with >55% reflectance in a wavelengths range of 0.3 to 2.5 microns, a second component with a first thermal emissivity peak value greater than 0.85 at a first wavelength in a range of 8 to 13 microns (μm), and a third component to mechanically bind together a mixture of the first component and second component.

Van Overmeere, Quentin↗

Modular Coaxial Power Converter for High-Density Integration into Medium-Voltage Cables

This work proposes to combine the functionality benefits of power electronics with the power density benefits of medium-voltage cables to create a streamlined, high-density power electronics solution that seamlessly integrates with medium-voltage cables. Located at the ends of a medium- or high-voltage line, the proposed converter uses a cascade of coaxial power conversion cells to gradually step down the voltage, and excels in high step-down applications. By mimicking the coaxial geometry of medium-voltage cables, the converter preserves the axisymmetric electric field of the cable which, when combined with a solid insulating dielectric, provides a voltage scaling advantage over conventional planar and PCB-based converter solutions. Similar to medium voltage cables, the converter is fully passively cooled. A passive cooling strategy allows for combined installation with existing medium voltage cable systems without the added cost, maintenance needs, infrastructure, and reliability concerns associated with active cooling systems. The scalability of the modular structure in combination with the integration benefits provide a flexible power electronics system that can adapt to the evolving demands of the grid.

coaxial power conversion cells↗

Simple device modification simultaneously enhances indoor passive evaporative cooling power and duration

Passive evaporative cooling from a damp cloth or vessel can be used for localized cooling of perishables such as food and medicine, drinking water, and even people. Such applications have two key objectives, which are normally in tension with each other: minimizing the water consumption rate and maximizing the cooling (steady-state temperature swing between the cool cloth and the warm surroundings). Here, we present a simple device that delivers higher performance in both metrics simultaneously by adding a perforated aluminum foil sheet suspended over a stagnant air layer to thermally shield the evaporating surface while also facilitating mass transfer. Experimental results demonstrate a simultaneous 10%–25% increase in temperature swing and 2–3× reduction in water consumption rate as compared to conventional evaporative cooling. This improvement is achieved through careful modeling to optimize the coupled heat and mass transfer through the airgap (thermally insulating and vapor permeable) and perforated foil (infrared reflective and vapor permeable).

Chen, Sarah Mizuno↗

Eco-friendly passive radiative cooling using recycled packaging plastics

Passive daytime radiative cooling, requiring zero external energy consumption, is a promising cooling strategy achieved by simultaneously reflecting solar irradiance and thermally radiating heat into the cold outer space (~3 K) through the atmospheric transparency window. However, current materials for passive radiative cooling face huge challenges, such as complicated fabrication approaches, expensive raw materials, and environmental requirements for practical applications. In line with the urgent need for plastic recycling to curb global environmental pollution, the recycled plastics are used to fabricate a passive radiative cooling material. Herein, the foam-paper composite (FPC) with excellent self-cooling capability is fabricated by a simple crushing-and-mixing procedure using recycled polystyrene (PS) foam and printer paper. The superhydrophobic PS foam particles not only protect the FPC from water damage for field applications but also reinforce its solar reflectivity via their porous structure. The cellulose fibers in printer paper can efficiently emit infrared thermal radiation into the cold outer space and bond dispersed PS foam particles together, further increasing its mechanical strength. The combination of highly diffusely reflective PS foam particles and fiber-based printer paper results in a reflectivity of 96% in the solar spectrum, a sub-ambient cooling performance of 8.4 degrees C, and a maximum radiative cooling power of 90 W/m2 during a 24-h cycle. Meanwhile, the FPC with high humidity can maintain its high solar reflectivity, which promotes its application in humid subtropical areas. Further, the low material cost and ease of fabrication will provide a path for effective daytime radiative cooling, especially in less developed areas.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Feasibility of Passive Cryogenic Cooling for Solar Powered Outer Planetary Missions

Spacescience instruments with cooled detectors require innovative thermal cooling solutions to meet science objectives. Detector sensitivity increases with decreasing temperature and low optics temperatures are often needed to reduce background photon noise. As the detector spectral range coverage increases from the visible to far infrared also requires lower detector temperatures. Increasing demands on detector performance lead to larger format detectors and higher refresh rates resulting in significant increases in power dissipation. Passive coolers rely on emissive power of radiating surfaces to reject heat to space. As the operating temperature requirements of detectors and optics decreases, the ability to reject heat to space becomes increasingly more difficult. Reducing both cooler internal parasitic and external environmental heat loads and maximizing the passive cooler field of view to space will enhance performance. While instrument heat loads and passive cooler parasitic heat loads are controlled by instrument designers, the external environmental heat loads and cooler views to space are governed by spacecraft and mission designers. Solar powered planetary missions require large arrays to generate sufficient power for spacecraft subsystems and payloads. Two or more solar array wings with cell coverage of the order of 40-80 m2 are often needed to generate sufficient power at 3-6 AU. These large arrays are typically symmetrically configured and can extend tens of meters. The arrays along with spacecraft attitude requirements near the target planetary bodies pose significant challenges for passive cooling at large AU. It is very difficult to provide a clear field of view to space for the cooler with large articulating arrays while keeping solar loads from impinging the cooler and meeting the spacecraft attitude science pointing requirements. This is counter intuitive because of the decreasing solar flux and colder planetary body temperatures at large AU. This paper presents the challenges and opportunities of passive cryogenic cooling versus active cooling for solar powered planetary missions.

Rodriguez, Jose I.↗

Sensitivity Analyses of Natural Convection in the AP1000 Passive Containment Cooling System Following LBLOCA Using CFD

The AP1000 power plant has implemented multiple layers of passive safety systems to enhance reactor safety and ensure system integrity during postulated scenarios, such as loss of coolant accident (LOCA) and main steam line break (MSLB). Among these, the passive containment cooling system (PCCS) is a safety-related system designed to prevent the containment from exceeding the design limits of both pressure and temperature following a postulated design basis accident, by transferring heat from the steel containment vessel to the atmosphere. During LOCA, natural air convection plays a vital role in removing heat from the steel containment vessel to the atmosphere. This is integrated with the condensate film from the Passive Containment Cooling Water Storage Tank (PCCWST). Air natural convection is also the only heat removal mechanism after the dry-out of the PCCWST and during the loss of shutdown decay heat removal (LOSDHR) event. Therefore, it is essential to investigate the thermal hydraulics behavior of the containment under transient conditions to ensure its safety and integrity. This paper presents a simplified CFD/ANSYS FLUENT model developed to analyze the impact of different parameters, such as air relative humidity, air temperature, and steel containment temperature, on the natural convection capability to remove the decay heat following LOCA. The model aims to examine the thermal behavior of the containment and provides a comprehensive understanding of the system's natural convection capability during postulated accidents. The results obtained from the model can be used to improve the safety and integrity of the containment system and provide valuable insights for future research in the field.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Analysis of Conduction Cooling Strategies for Wire Arc Additive Manufacturing

Metal additive manufacturing (AM) processing consists of numerous parameters which take time to optimize for various geometries. One aspect of the metal AM process that continues to be explored is the control of thermal energy accumulation during component manufacturing due to the melting and solidification of the feedstock. Excessive energy accumulation causes thermal failure of the component while minimal energy accumulation causes lack of fusion with the build plate or previous layer. The ability to simulate the thermal response of an AM component can increase research efficiency by reducing the time to optimize thermal energy accumulation. This paper presents an effective implementation of finite element analysis to determine the thermal response of a wire arc additive manufactured component with various build plate sizes and cooling methods including, integral build plate cooling, oversized build plates with passive cooling, and non-integral build plate cooling. The use of integral build plate cooling channels was shown to decrease the interpass temperature at the conclusion of the build process by 55% and build plate temperature by 96% compared to the conventionally deposited sample with 20 second dwell time. The use of a tall build plate with passive cooling was shown to reduce the interpass temperature by 32% as compared to the conventionally deposited sample with 20 second dwell time. Each cooling strategy evaluated decreased the interpass temperature within a range of 20–55% which enables higher deposition rates and decreased dwell times during depositions. The cooling strategies are designed to be implemented in a hybrid or retrofit AM platform to mitigate concerns of the thermal input from the additive process having detrimental effects on the precision of the machining process. This paper shows that accurate simulations of all strategies can be used to accurately predict the thermal response of the various strategies discussed. These cooling strategies will allow for increased deposition rates with comparable interpass temperature and decreased dwell time, increasing deposition efficiency. This model and these simulations are verified by experimental results. It is concluded that passive strategies, such as the over-sized tall build plate, can be used when liquid coolant in the AM environment could negatively affect the deposition process. Active cooling strategies, such as the integral build plate cooling could be used if low thermal conductivity materials are deposited or higher material deposition rates are desired. This paper discusses the use of active and passive cooling used during AM and shows how a simulation model can be used to make design choices for cooling strategies. The model also enables verification of select critical process parameters such as dwell times for a desired interpass temperature.

Heinrich, Lauren↗

The X-ray Integral Field Unit at the end of the Athena reformulation phase

The Athena mission entered a redefinition phase in July 2022, driven by the imperative to reduce the mission cost at completion for the European Space Agency below an acceptable target, while maintaining the flagship nature of its science return. This notably called for a complete redesign of the X-ray Integral Field Unit (X-IFU) cryogenic architecture towards a simpler active cooling chain. Passive cooling via successive radiative panels at spacecraft level is now used to provide a 50 K thermal environment to an X-IFU owned cryostat. 4.5 K cooling is achieved via a single remote active cryocooler unit, while a multi-stage Adiabatic Demagnetization Refrigerator ensures heat lift down to the 50 mK required by the detectors. Amidst these changes, the core concept of the readout chain remains robust, employing Transition Edge Sensor microcalorimeters and a SQUID-based Time-Division Multiplexing scheme. Noteworthy is the introduction of a slower pixel. This enables an increase in the multiplexing factor (from 34 to 48) without compromising the instrument energy resolution, hence keeping significant system margins to the new 4 eV resolution requirement. This allows reducing the number of channels by more than a factor two, and thus the resource demands on the system, while keeping a 4’ field of view (compared to 5’ before). Here, in this article, we will give an overview of this new architecture, before detailing its anticipated performances. Finally, we will present the new X-IFU schedule, with its short term focus on demonstration activities towards a mission adoption in early 2027.

Peille, Philippe [Centre National d’Etudes Spatial↗

Manufacturing, Characterization and Terrestrial Passive Radiative Cooling Performance of Nanofibrous PTFR-PEO Composite Thermal Coatings

Passive heat management is desirable in many applications since it can reduce the energy expended for cooling, for example, in buildings and automobiles. Specifically, materials with wavelength-dependent reflectance and emittance can manage incident solar fluxes while enabling passive radiative cooling by thermal emission. This study demonstrates the use of polymeric nanofibers, specifically polytetrafluoroethylene (PTFE) and polyethylene oxide (PEO) composite, as thermal coatings for passive temperature control. Employing the electrospinning fabrication process, we engineer nano and micro-scale fibrous structures, studying the influence of fabrication parameters, such as precursor material concentration and rotating collector speed, on fiber geometry and optical properties. To understand the role of material and fiber geometry on optical performance, we characterize various samples' spectral reflectance, absorptance, and transmittance using spectrophotometers interfaced with integrating spheres. The results show the potential of nanofabricated PTFE-PEO coatings as promising candidates for passive thermal control. We highlight their competitive edge by comparing their solar reflectance and emittance values to existing passive radiative thermal control materials. In essence, this study contributes to advancing passive heat management technologies, offering insights into optimizing material composition and fabrication techniques for enhanced performance in various applications.

Chieloka Ibekwe↗