Measurement of the ionization response of amorphous selenium with 122 keV γ rays

In this work, we performed a measurement of the ionization response of 200 μm-thick amorphous selenium (aSe) layers under drift electric fields of up to 50 V/μm. The aSe target was exposed to ionizing radiation from a 57 Co radioactive source and the ionization pulses were recorded with high resolution. Using the spectral line from the photoabsorption of 122 keV γ rays, we measured the charge yield in aSe and the line width as a function of drift electric field. From a detailed microphysics simulation of charge generation and recombination in aSe, we conclude that the strong dependence of recombination on the ionization track density provides the dominant contribution to the energy resolution in aSe. These results provide valuable input to estimate the sensitivity of a proposed next-generation search for the neutrinoless ββ decay of 82 Se that aims to employ imaging sensors with an active layer of aSe. We estimate the RMS line width of the integrated ionization signal from neutrinoless ββ decay events (of deposited energy 3 MeV) to be 2.0% for a drift field of 50 V/μm. The energy resolution can be improved to 1% by correcting for the charge yield as a function of ionization density along the imaged electron tracks.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

On-chip probabilistic inference for charged-particle tracking at the sensor edge

Modern scientific instruments operate under increasingly extreme constraints on bandwidth, latency, and power. Inference at the sensor edge determines experimental data collection efficiency by deciding which information to save for further analysis. Particle tracking detectors at the Large Hadron Collider exemplify this challenge: pixelated silicon sensors generate rich spatiotemporal ionization patterns, yet most of this information is discarded due to data-rate limitations. Concurrently, advancements in co-design tools provide rapid turn-around for incorporating machine learning into application-specific integrated circuits, motivating designs for particle detectors with new integrated technologies. We demonstrate that neural networks embedded in the front-end electronics can infer charged-particle kinematic parameters from a single silicon layer. We regress hit positions and incident angles with calibrated uncertainties, while satisfying stringent constraints on numerical precision, latency, and silicon area. Our results establish a path toward probabilistic inference directly at the edge, opening new opportunities for intelligent sensing in high-rate scientific instruments.

Das, Arghya Ranjan [Purdue U.] (ORCID:000000018451↗

The quality control programme for ITk strip tracker module assembly

The assembly of the ATLAS Inner Tracker requires the construction of 19,000 silicon strip sensor detector modules in eight different geometries. Modules will be assembled and tested at 31 institutes on four continents from sensors, readout chips, and flexes. In order to adhere to the module specifications defined for sufficient tracking performance, a rigorous programme of quality control (QC) was established to cover components at every stage of assembly. Here, this contribution presents an overview of the QC programme for ITk strip tracker modules, issues encountered during the pre-production phase (5% of the production volume), and their solutions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Holographic particle detection

The feasibility was studied of developing a novel particle track detector based on the detection of 1p-1s emission radiation from electron bubbles in liquid helium. The principles, design, construction, and initial testing of the detection system have been described in previous reports. The main obstacle encountered was the construction of the liquid-helium tight infrared windows. Despite numerous efforts in testing and redesigning the windows, the problem of window leakage at low temperature persisted. Due to limited time and resources, attention was switched to investigating the possibility of using room-temperature liquid as the detection medium. A possible mechanism was the detection of de-excitation radiation emitted from localized electrons in common liquids where electrons exhibit low mobilities, as suggested in the previous report. The purity of the liquid is critical in this method as the dissolved impurities (such as oxygen), even in trace amounts, will act as scavengers of electrons. Another mechanism is discussed whereby the formation of the superoxide ions by electron scavenging behavior of dissolved oxygen is exploited to detect the track of ionizing particles. An experiment to measure the ionization current produced in a liquid by a pulsed X-ray beam in order to study propertiies of the ions is also reported.

Bowen, Theodore↗

Micro-Transfer Printing of Repeaters on Passive Interposer

Silicon-based sensors are central to particle physics experiments and particle tracking detectors. New-generation Large Focal Plane Arrays (LFPAs) cover areas that extend beyond several square meters. Distributing power and transporting data across such areas while maintaining good signal integrity is a complicated challenge. Tiling the detector on an organic interposer would be far too expensive and take too much space while offering little to no advantage regarding signal integrity. Passive silicon interposers are much less expensive and more integrable but would worsen signal integrity because of their inherent higher dielectric constant. Active interposers are a good compromise from the economic and signal integrity standpoint; unfortunately, their yield trends to zero for areas greater than a reticle size, making this technology incompatible with our application. NHanced proposes to duplicate the behavior of a high-yield, low-cost active interposer by printing active microcomponents on a passive interposer with our die-to-wafer micro-transfer printing (MTP) technology. This resolves the signal integrity and power distribution limitations. In Phase I, we designed and simulated analog and digital repeaters to be MTPed onto a passive silicon interposer test wafer.

2.5D↗

Test beam performance of a CBC3-based mini-module for the Phase-2 CMS Outer Tracker before and after neutron irradiation

The Large Hadron Collider (LHC) at CERN will undergo majorupgrades to increase the instantaneous luminosity up to5–7.5×10$^{34}$ cm$^{-2}$s$^{-1}$. This High Luminosityupgrade of the LHC (HL-LHC) will deliver a total of3000–4000 fb$^{-1}$ of proton-proton collisions at acenter-of-mass energy of 13–14 TeV. To cope with thesechallenging environmental conditions, the strip tracker of the CMSexperiment will be upgraded using modules with two closely-spacedsilicon sensors to provide information to include tracking in theLevel-1 trigger selection. This paper describes the performance, ina test beam experiment, of the first prototype module based on thefinal version of the CMS Binary Chip front-end ASIC before and afterthe module was irradiated with neutrons. Results demonstrate thatthe prototype module satisfies the requirements, providing efficienttracking information, after being irradiated with a total fluencecomparable to the one expected through the lifetime of theexperiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurements of an AC-LGAD strip sensor with a 120 GeV proton beam

The development of detectors that provide high resolution in four dimensions has attracted wide-spread interest in the scientific community for several applications in high-energy physics, nuclear physics, medical imaging, mass spectroscopy as well as quantum information. In addition to high time resolution and thanks to the AC-coupling of the electrodes, LGAD silicon sensors can provide high resolution in the measurement of spatial coordinates of an incident minimum ionizing particle. Such AC-coupled LGADs, also known as AC-LGADs, are therefore considered as candidates for future detectors to provide 4-dimensional measurements in a single sensing device with 100% fill factor. This article presents the first characterization of an AC-LGAD sensor with a proton beam of 120 GeV momentum at Fermilab. The sensor consists of strips with 80 μm width, fabricated at Brookhaven National Laboratory. The signal properties, efficiency, spatial, and time resolution are presented. Overall, the experimental results show that the time resolution of such an AC-LGAD is compatible to standard LGADs with similar gain, and that AC-LGADs can be segmented with fine pitches as standard strip or pixel detectors.

47 OTHER INSTRUMENTATION↗

Performance study of a 3×1×1 m 3 dual phase liquid Argon Time Projection Chamber exposed to cosmic rays

We report the results of the analyses of the cosmic ray data collected with a 4 tonne (3×1×1 m 3 ) active mass (volume) Liquid Argon Time-Projection Chamber (TPC) operated in a dual-phase mode. We present a detailed study of the TPC's response, its main detector parameters and performance. The results are important for the understanding and further developments of the dual-phase technology, thanks to the verification of key aspects, such as the extraction of electrons from liquid to gas and their amplification through the entire one square metre readout plain, gain stability, purity and charge sharing between readout views.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurements of time and spatial resolution of AC-LGADs with different designs

AC-LGAD sensors are prime candidates for fast and precise measurement of charged particles in a variety of applications. In a fine-pitched pixel or strip AC-LGAD sensor, the signal generated by the passage of a particle is not localized in a limited volume in the sensor, but is shared among multiple electrodes. This signal sharing characteristic allows us to improve the spatial resolution of AC-LGAD sensors beyond the capabilities of common silicon trackers. Since the magnitude of the shared signal depends on the distance between the pixels or strips and the point of passage of the particle, signal sharing is strongly influenced by the geometry of the sensor. The electrode pitch and gap size as well as the shape can be fine tuned to maximize the space resolution, while keeping the detector granularity and the number of channels to be read out under control. Prototypes of AC-LGAD sensors produced at the Brookhaven National Laboratory covering a variety of possible geometries have been studied via Transient Current Technique using an infrared laser, and the signal sharing, spatial resolution, and time resolution of the different topologies have been measured. These results have been compared with measurements performed in test-beams with 120 GeV protons at the Fermilab Test Beam Facility. A time resolution of ~30 ps can be achieved using AC-LGAD sensors with a thickness of 50 μm, compatible to that of standard DC-coupled LGADs, while presenting a far superior spatial resolution. Finally, this combination of high precision, fast timing capabilities, and low material budget makes AC-LGADs an ideal choice for a truly 4D detector.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Reflectance and fluorescence characteristics of PTFE coated with TPB at visible, UV, and VUV as a function of thickness

Polytetrafluoroethylene (PTFE) is an excellent diffuse reflector widely used in light collection systems for particle physics experiments. In noble element systems, it is often coated with tetraphenyl butadiene (TPB) to allow detection of vacuum ultraviolet scintillation light. Here, in this work this dependence is investigated for PTFE coated with TPB in air for light of wavelengths of 200 nm, 260 nm, and 450 nm. The results show that TPB-coated PTFE has a reflectance of approximately 92% for thicknesses ranging from 5 mm to 10 mm at 450 nm, with negligible variation as a function of thickness within this range. A cross-check of these results using an argon chamber supports the conclusion that the change in thickness from 5 mm to 10 mm does not affect significantly the light response at 128 nm. Our results indicate that pieces of TPB-coated PTFE thinner than the typical 10 mm can be used in particle physics detectors without compromising the light signal.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evidence for the siderophilic behavior of meteoritic bismuth

The microdistributions of Bi and Pb-208 in the Khohar L3 chondrite were determined in situ using radiography techniques based on particle track detectors. Strong (enrichment factors 10 to 100) localizations of Bi were found in association with kamacite; no enhancement of Bi or Pb was found in sulfides. High-magnification microprobe and reflected light observations strongly indicate that Bi actually resides in the kamacite, providing evidence for the siderophilic nature. The minor and major element chemistry of the metals in the sample was typical of chondrites of its type. The unusual Bi distribution in the Khohar chondrite suggests that it may have been exposed to high Bi partial pressures during slow cooling at kamacite-taenite phase separation in a volatile-rich region of a parent body, or that Bi may have been incorporated into previously cooled grains by mild reheating.

Woolum, D. S.↗

Performance of the reconstruction and identification of high-momentum muons in proton-proton collisions at $\sqrt{s} =$ 13 TeV

The CMS detector at the LHC has recorded events from proton-proton collisions, with muon momenta reaching up to 1.8 TeV in the collected dimuon samples. These high-momentum muons allow direct access to new regimes in physics beyond the standard model. Because the physics and reconstruction of these muons are different from those of their lower-momentum counterparts, this paper presents for the first time dedicated studies of efficiencies, momentum assignment, resolution, scale, and showering of very high momentum muons produced at the LHC. These studies are performed using the 2016 and 2017 data sets of proton-proton collisions at &surd;s = 13 TeV with integrated luminosities of 36.3 and 42.1 fb−1, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reconstruction of Charged Particle Tracks in Realistic Detector Geometry Using a Vectorized and Parallelized Kalman Filter Algorithm

One of the most computationally challenging problems expected for the High-Luminosity Large Hadron Collider (HL-LHC) is finding and fitting particle tracks during event reconstruction. Algorithms used at the LHC today rely on Kalman filtering, which builds physical trajectories incrementally while incorporating material e ects and error estimation. Recognizing the need for faster computational throughput, we have adapted Kalman-filterbased methods for highly parallel, many-core SIMD and SIMT architectures that are now prevalent in high-performance hardware. Previously we observed significant parallel speedups, with physics performance comparable to CMS standard tracking, on Intel Xeon, Intel Xeon Phi, and (to a limited extent) NVIDIA GPUs. While early tests were based on artificial events occurring inside an idealized barrel detector, we showed subsequently that our mkFit software builds tracks successfully from complex simulated events (including detector pileup) occurring inside a geometrically accurate representation of the CMS-2017 tracker. Here, we report on advances in both the computational and physics performance of mkFit, as well as progress toward integration with CMS production software. Recently we have improved the overall eciency of the algorithm by preserving short track candidates at a relatively early stage rather than attempting to extend them over many layers. Moreover, mkFit formerly produced an excess of duplicate tracks; these are now explicitly removed in an additional processing step. We demonstrate that with these enhancements, mkFit becomes a suitable choice for the first iteration of CMS tracking, and eventually for later iterations as well. We plan to test this capability in the CMS High Level Trigger during Run 3 of the LHC, with an ultimate goal of using it in both the CMS HLT and oine reconstruction for the HL-LHC CMS tracker.

Cerati, Giuseppe↗

Construction of precision sMDT detector for the ATLAS Muon Spectrometer upgrade

Here, this paper describes the small-diameter monitored drift-tube detector construction at the University of Michigan as a contribution to the ATLAS Muon Spectrometer upgrade for the high-luminosity Large Hadron Collider at CERN. Measurements of the first 30 chambers built at Michigan show that the drift tube wire position accuracy meets the specification of 20 μm. The positions of the platforms for alignment and magnetic field sensors are all installed well within the required precision. The cosmic ray test measurements show single wire tracking resolution of 100 ± 7 μm with an average detection efficiency above 99%. The infrastructure, tooling, techniques, and procedures for chamber production are described in detail. The results from the chamber quality control tests of the first 30 constructed chambers are reported.

47 OTHER INSTRUMENTATION↗

The straw tracking detector for the Fermilab Muon g-2 Experiment

The Muon g-2 Experiment at Fermilab uses a gaseous straw tracking detector to make detailed measurements of the stored muon beam profile, which are essential for the experiment to achieve its uncertainty goals. Positrons from muon decays spiral inward and pass through the tracking detector before striking an electromagnetic calorimeter. The tracking detector is therefore located inside the vacuum chamber in a region where the magnetic field is large and non-uniform. As such, the tracking detector must have a low leak rate to maintain a high-quality vacuum, must be non-magnetic so as not to perturb the magnetic field and, to minimize energy loss, must have a low radiation length. The performance of the tracking detector has met or surpassed the design requirements, with adequate electronic noise levels, an average straw hit resolution of (110 ± 20) μm, a detection efficiency of 97% or higher, and no performance degradation or signs of aging. The tracking detector's measurements result in an otherwise unachievable understanding of the muon's beam motion, particularly at early times in the experiment's measurement period when there are a significantly greater number of muons decaying. This is vital to the statistical power of the experiment, as well as facilitating the precise extraction of several systematic corrections and uncertainties. This paper describes the design, construction, testing, commissioning, and performance of the tracking detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Beam test performance of prototype silicon detectors for the Outer Tracker for the Phase-2 Upgrade of CMS

A new CMS tracker detector will be installed for operation at the High Luminosity LHC (HL-LHC). This detector comprises modules with two closely spaced parallel sensor plates and front-end ASICs capable of transmitting tracking information to the CMS Level-1 (L1) trigger at the 40 MHz beam crossing rate. The inclusion of tracking information in the L1 trigger decision will be essential for selecting events of interest efficiently at the HL-LHC. The CMS Binary Chip (CBC)has been designed to read out and correlate hits from pairs of tracker sensors, forming so called track stubs. For the first time, a prototype irradiated module and a full-sized module, both equipped with the version 2 of the CBC, have been operated in test beam facilities. The efficiency of the stub finding logic of the modules for various angles of incidence has been studied. The ability of the modules to reject tracks with transverse momentum less than 2 GeV has been demonstrated. For modules built with irradiated sensors, no significant drop in the stub finding performance has been observed. Results from the beam tests are described in this paper.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Construction of precision wire readout planes for the Short-Baseline Near Detector (SBND)

The Short-Baseline Near Detector time projection chamber is unique in the design of its charge readout planes. These anode plane assemblies (APAs) have been fabricated and assembled to meet strict accuracy and precision requirements: wire spacing of 3 mm ± 0.5 mm and wire tension of 7 N ± 1 N across 3,964 wires per APA, and flatness within 0.5 mm over the 4 m × 2.5 m extent of each APA . Here, we describe the design, manufacture and assembly of these key detector components, with a focus on the quality assurance at each stage.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparative evaluation of analogue front-end designs for the CMS Inner Tracker at the High Luminosity LHC

The CMS Inner Tracker, made of silicon pixel modules, will be entirely replaced prior to the start of the High Luminosity LHC period. One of the crucial components of the new Inner Tracker system is the readout chip, being developed by the RD53 Collaboration, and in particular its analogue front-end, which receives the signal from the sensor and digitizes it. Three different analogue front-ends (Synchronous, Linear, and Differential) were designed and implemented in the RD53A demonstrator chip. A dedicated evaluation program was carried out to select the most suitable design to build a radiation tolerant pixel detector able to sustain high particle rates with high efficiency and a small fraction of spurious pixel hits. The test results showed that all three analogue front-ends presented strong points, but also limitations. The Differential front-end demonstrated very low noise, but the threshold tuning became problematic after irradiation. Moreover, a saturation in the preamplifier feedback loop affected the return of the signal to baseline and thus increased the dead time. The Synchronous front-end showed very good timing performance, but also higher noise. For the Linear front-end all of the parameters were within specification, although this design had the largest time walk. This limitation was addressed and mitigated in an improved design. The analysis of the advantages and disadvantages of the three front-ends in the context of the CMS Inner Tracker operation requirements led to the selection of the improved design Linear front-end for integration in the final CMS readout chip.