At least 37 records · Page 2

Evaluating Radiation Impact on Superconducting Transmon Qubits in Above and Underground Facilities

Superconducting qubits can be sensitive to sudden energy deposits into the substrate from cosmic rays and ambient radioactivity. While previous studies have primarily focused on exploring correlated effects over time and distance due to cosmic rays, this study uniquely offers a direct comparison of a transmon qubit's response at Fermilab SQMS above-ground facilities and the deep-underground Gran Sasso Laboratory (INFN-LNGS, Italy). Despite the vastly different radiation environments, we observe a similar average qubit lifetime (T1) of approximately 80 microseconds at both sites. We then employ a fast decay detection protocol and investigate the time structure, sensitivity, and relative rates of triggered events due to radiation versus intrinsic noise. We compare the above and underground performance of several high-coherence qubits with similar designs. Our findings reveal no significant difference in events with radiation-like signatures between above-ground and underground conditions for these sapphire and niobium-based transmon qubits. This suggests that most such events are likely due to other noise sources, which predominantly contribute to single-qubit errors in contemporary transmon qubits. By exposing the qubits to gamma sources with varying activity levels, we further evaluate their response to radiation in a low-background environment. The results show that qubits can indeed detect particle impacts; however, this capability is only realized by substantially reducing other noise sources, which in turn affects detection efficiency [1].

Roy, Tanay↗

Ultra-sensitive radon assay using an electrostatic chamber in a recirculating system

Rare event searches such as neutrinoless double beta decay and Weakly Interacting Massive Particle detection require ultra-low background detectors. Radon contamination is a significant challenge for these experiments, which employ highly sensitive radon assay techniques to identify and select low-emission materials. This work presents the development of ultra-sensitive electrostatic chamber (ESC) instruments designed to measure radon emanation in a recirculating gas loop, for future lower background experiments. Unlike traditional methods that separate emanation and detection steps, this system allows continuous radon transport and detection. This is made possible with a custom-built recirculation pump. A Python-based analysis framework, PyDAn, was developed to process and fit time-dependent radon decay data. Radon emanation rates are given for various materials measured with this instrument. A radon source of known activity provides an absolute calibration, enabling statistically-limited minimal detectable activities of 20 µBq. These devices are powerful tools for screening materials in the development of low-background particle physics experiments.

47 OTHER INSTRUMENTATION↗

Ultra-sensitive radon assay using an electrostatic chamber in a recirculating system

Rare event searches such as neutrinoless double beta decay and Weakly Interacting Massive Particle detection require ultra-low background detectors. Radon contamination is a significant challenge for these experiments, which employ highly sensitive radon assay techniques to identify and select low-emission materials. This work presents the development of ultra-sensitive electrostatic chamber (ESC) instruments designed to measure radon emanation in a recirculating gas loop, for future lower background experiments. Unlike traditional methods that separate emanation and detection steps, this system allows continuous radon transport and detection. This is made possible with a custom-built recirculation pump. A Python-based analysis framework, PyDAn, was developed to process and fit time-dependent radon decay data. Radon emanation rates are given for various materials measured with this instrument. A radon source of known activity provides an absolute calibration, enabling statistically-limited minimal detectable activities of 20 uBq. These devices are powerful tools for screening materials in the development of low-background particle physics experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Toward an integrated multi-gigahertz ionizing particle diagnostic

Needs arising at both current and future accelerator facilities call for the development of radiation-hardened position-sensing diagnostics that can operate with multi-GHz repetition rates. Such instruments are likely to also have applications in the diagnosis of rapid plasma behavior. Here, building on the recent work of our Advanced Accelerator Diagnostics Collaboration, we are exploring the development of integrated multi-GHz ionizing particle detection systems based on chemical-vapor deposition diamond sensors, with the initial goal of producing a quadrant detector that can determine the intensity and centroid position of a particle beam at a repetition rate between 5 and 10 GHz. Results from our initial high-speed characterization work are presented, including those from a single-channel sensor with a GHz response. Approaches to achieving multi-GHz (5–10 GHz) rate capability, including the design of a dedicated Application Specific Integrated Circuit and the use of 3D RF-solver computer aided design software, are presented and discussed in more detail. 3D RF simulations suggest clean pulses of duration less than 250 ps (FWHM less than 125 ps) can be achieved with the approaches developed by this work.

43 PARTICLE ACCELERATORS↗

Calorimetric Identification of Composite Nuclei in LAr

In neutrino-nucleus interactions, Final State Interactions (FSI) can cause nucleons to scatter or form heavier composite particles like deuterons and tritons. Observing these particles would provide direct evidence of FSI and help improve interaction models, which is essential for precise neutrino energy reconstruction in future experiments like DUNE. Our Goal: Develop an analysis to detect particles heavier than protons in ICARUS data to better constrain FSI models.

McCright, Hannah [Maryland U., College Park]↗

Identification of Prompt Proton Emission in $N = Z - 1$ 61 Ga: Isospin Symmetry at the Limit of Nuclear Binding

Excited states in the proton drip line nucleus 61 Ga were populated via the fusion-evaporation reaction 24 Mg ⁢( 40 Ca, 𝑝⁢2⁢𝑛)⁢ 61 Ga. The experimental setup at Argonne National Laboratory comprised a novel combination of the Gammasphere array with two CD-shaped double-sided Si-strip detectors inside the Microball CsI(Tl) charged-particle detection array, as well as the Neutron-Shell liquid scintillators and the Fragment Mass Analyzer. Owing to the setup’s unprecedented in-beam proton spectroscopy and tracking capabilities, a coincidence between a 957.6(5)-keV 𝛾 ray and a 1.876(24)-MeV proton line was observed, which identifies the quasibound proton 𝜋⁢𝑔 9/2 single-particle state in 61 Ga at 𝐸 𝑥 = 2150⁢(34) keV. This probes isospin symmetry at the limit of nuclear binding by providing a unique challenge for the shell-model interpretation of mirror nuclei beyond doubly magic 56 Ni .

Hrabar, Yuliia [Lund Univ. (Sweden)] (ORCID:000000↗

Angular Dependence of Drell-Yan in the SeaQuest Experiment using Deep Neural Network-Based Reconstruction

The SeaQuest and SpinQuest experiments at Fermilab were designed to probe the internal dynamics of protons and neutrons via the angular dependence of muons created by colliding 120 GeV protons into stationary targets. To do this, it is necessary to translate the detector data into coherent information about the particles detected in the experiment. This dissertation describes the development and implementation of QTracker, a neural network-based algorithm designed to reconstruct muons. The application of QTracker to experimental data yields improved reconstruction of muon tracks, allowing for a more precise investigation of the transverse momentum distributions and angular modulations in the Drell-Yan process. This work highlights the potential of neural network-based methods to advance particle tracking and enhance our understanding of nucleon structure.

Conover, Arthur↗

Potential absence of observed π2 linear-chain structures in 14O via 10C(α,α) resonances scattering

Background: The preference for light nuclear systems to coagulate into -particle clusters has been well-studied. The possibility of a linear chain configuration of -particles would allow for a new way to study this phenomenon. Purpose: A rotational band of states in C has been claimed showing a linear chain structure. The mirror system, O, has been studied here to examine how this linear chain structure is affected by replacing the valence neutrons with protons. Method: A beam of C was incident into a chamber filled with He:CO gas with the tracks recorded inside the TexAT Time Projection Chamber and the recoil -particles detected by a silicon detector array to measure the cross section. Results: The experimental cross section was compared with previous studies and fit using R-Matrix theory with the previously-observed O states being transformed to the C using mirror symmetry. The measured cross section does not replicate the claimed states, with the predicted cross section exceeding that observed at several energies and angles. Conclusion: A series of possibilities are highlighted with the most likely being that the originally-seen C states did not constitute a rotational band with a potentially incorrect spin assignment due to the limitations of the angular correlation method with non-zero spin particles. The work highlights the difficulties in measuring broad resonances corresponding to a linear chain state in a high level density.

Bishop, J.↗

ADRIANO2 Calorimeter Performance from 2022 Test Beams

A novel high-granularity dual-readout calorimetric technique was developed as part of the T1604 collaboration. The ADRIANO2 Calorimeter Prototype consists of a pair of optically isolated, small sized tiles made of scintillating plastic and lead glass. Čerenkov light from the lead glass are exploited to for high resolution timing measurements, while high granularity from scintillating plastic can be used to probe the spatial component of the particle shower. This setup works for excellent energy resolution and particle detection for REDTOP as it is crucial for a calorimeter to detect the decay products of eta/eta-prime mesons. Measurements were collected on ADRIANO2 between February to December 2022 to evaluate the detector performance at Fermilab’s Test Beam Facility. The key metrics extracted from my analysis are the detector’s efficiency for various tile configuration and light-yield which will then be used as parameters for an upgraded REDTOP monte-carlo simulation campaign. An in-depth analysis of ADRIANO2 performance are detailed in this presentation.

43 PARTICLE ACCELERATORS↗

Horizontal 1 K refrigerator with novel loading mechanism for polarized solid targets

We describe a helium evaporation refrigerator used to cool dynamically polarized proton and deuteron targets for electron-scattering experiments using the CEBAF Large Acceptance Spectrometer CLAS12 at Jefferson Lab. The geometry of the CLAS12 detector systems places severe design and construction constraints on the refrigerator and its ancillary equipment, resulting in a horizontal cryostat with a length of 4 m. The 16 cm 3 target samples, consisting of frozen ammonia (NH 3 or ND 3 ), are loaded at the upstream end of the cryostat and moved to the beam-interaction region using a novel transport mechanism. At this location they are cooled with superfluid helium and polarized via dynamic nuclear polarization at 1 K and 5 T. In this manner samples can be replaced and cooled to 1 K in about 30 minutes without disturbing any elements of the electron beam line or particle detection system. In conclusion, we estimate that this method saved 18 days of valuable beam time over the course of a recent, 88-day long experiment.

Evaporation refrigerator↗

Measurement of the Z boson invisible width at $\sqrt{s}=13$ TeV with the ATLAS detector

A measurement of the invisible width of the Z boson using events with jets and missing transverse momentum is presented using 37 fb -1 of 13 TeV proton–proton data collected by the ATLAS detector in 2015 and 2016. The ratio of Z → inv to Z → ℓℓ events, where inv refers to non-detected particles and ℓ is either an electron or a muon, is measured and corrected for detector effects. Events with at least one energetic central jet with p T ≥ 110 GeV are selected for both the Z → inv and Z → ℓℓ final states to obtain a similar phase space in the ratio. The invisible width is measured to be 506 ± 2 (stat.) ± 12 (syst.) MeV and is the single most precise recoil-based measurement. The result is in agreement with the most precise determination from LEP and the Standard Model prediction based on three neutrino generations.

13000 GeV-cms↗

Block segmentation in feature space for realtime object detection in high granularity images

Computer vision has applications in object detection, image recognition and classification, and object tracking. One of the challenges of computer vision is the presence of useful information at multiple distance scales. Filtering techniques may sacrifice details at small scales in order to prioritize the analysis of large-scale features of the image. We present a strategy for coarse-graining multidimensional data while maintaining fine-grained detail for subsequent analysis. The algorithm is based on fixed-size block segmentation in the feature space. We apply this strategy to solve the long-standing challenge of detecting particle trajectories at the Large Hadron Collider in real time.

Computer vision↗

First-Principles insights into group-V impurities and their impact on germanium detector performance

The outstanding properties of high-purity germanium (HPGe) detectors, such as excellent energy resolution, high energy sensitivity, and a low background-to-signal ratio, make them essential and ideal candidates for detecting particle signatures in nuclear processes such as neutrino-less double beta decay (0νββ). However, the presence of defects and impurities in HPGe crystals can lead to charge trapping, which affects carrier mobility and results in significant energy resolution degradation. In this work, we employ density functional theory with a hybrid functional to study the energetics of possible point defects in Ge. Our findings indicate that group-V impurities form more readily in Ge compared to vacancy and interstitial of Ge. Unlike N dopants, which yield deep trap states, P, As, and Sb create shallow traps close to the conduction band edge of Ge. Furthermore, we predict that group-V defects can condense into defect complexes with Ge vacancies. These vacancy-impurity complexes form deep traps in Ge, similar to Ge vacancies, suggesting that both vacancies and vacancy-impurity complexes contribute to charge trapping in these detectors, thereby diminishing their performance.

36 MATERIALS SCIENCE↗

The BUTTON-30 detector at Boulby

The BUTTON-30 detector is a 30-tonne technology demonstrator designed to evaluate the potential of hybrid event detection, simultaneously exploiting both Cherenkov and scintillation light to detect particles produced in neutrino interactions. The detector is installed at a depth of 1.1 km in the Boulby Underground Laboratory allowing to test the performance of this new technology underground in a low background environment. This paper describes the design and construction of the experiment.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

High precision measurements of the proton elastic electromagnetic form factors and their ratio at 𝑄 2 = 0.50, 2.64, 3.20, and 4.10 GeV 2

The advent of high-intensity, high-polarization electron beams led to significantly improved measurements of the ratio of the proton’s charge to electric form factors, 𝐺 𝐸⁢ 𝑝 ⁡/𝐺 𝑀⁢ 𝑝 . However, high-𝑄 2 measurements of this ratio yielded significant disagreement with extractions based on unpolarized scattering measurements, raising questions about the reliability of the measurements and consistency of the techniques. Jefferson Lab experiment E01-001 was designed to provide a high precision extraction of 𝐺 𝐸⁢ 𝑝 ⁡/𝐺 𝑀⁢ 𝑝 from unpolarized cross-section measurements using a modified version of the Rosenbluth separation technique to allow for a more precise comparison with polarization data. Rosenbluth separations involve precise measurements of the angular dependence of the elastic 𝑒−𝑝 cross section at fixed momentum transfer, 𝑄 2 . Conventional Rosenbluth separations detect the scattered electron, requiring the comparisons of measurements with very different detected electron energy and rate for electrons at different angles. Our ‘‘super-Rosenbluth’’ measurement detected the struck proton, rather than the scattered electron to extract the elastic 𝑒−𝑝 cross section. This yielded a fixed momentum for the detected particle and dramatically reduced variation of the cross section with angle, significantly reducing rate- and momentum-dependent corrections and uncertainties. We measure the cross section vs angle with high relative precision, allowing for extremely high precision extractions of 𝐺 𝐸⁢ 𝑝 ⁡/𝐺 𝑀⁢ 𝑝 at 𝑄 2 = 2.64, 3.20, and 4.10 GeV 2 . Our results are consistent with traditional Rosenbluth extractions, but with much smaller corrections and systematic uncertainties, comparable to the uncertainties from polarization measurements. Our data confirm the discrepancy between Rosenbluth and polarization extractions of the proton form factor ratio using an improved Rosenbluth extraction that yields smaller and less-correlated uncertainties than those typical of previous Rosenbluth extractions. Here, we compare our results to calculations of two-photon exchange effects and find that the observed discrepancy can be relatively well explained by such effects.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A 32-Channel Cryo-CMOS ASIC for SNSPD Biasing and Readout with Picosecond

Superconducting nanowire single-photon detectors (SNSPD) are a promising technology for particle detection. Although SNSPDs have demonstrated picosecond timing accuracy, scaling up large arrays has proved challenging. In this work, we introduce a 32-channel cryo-CMOS application-specific integrated circuit (ASIC) that can be tightly integrated with SNSPD arrays. The ASIC is designed to operate at a temperature of 4K and can perform up to 32 simultaneous timing measurements with a root-mean-square (RMS) accuracy of 8.0ps. The ASIC includes on-chip circuitry for externally biasing superconducting devices, low-noise amplifiers for reading superconducting devices, high-resolution time-to-digital converters (TDC) for time-tagging events, and serializers for transmitting data to room-temperature electronics. The ASIC is manufactured in a 22nm FDSOI process and occupies an area of 4.0mm x 1.0mm. The performance of the ASIC was verified using custom cryogenic device models internally developed for the 22nm SOI process. Measurement results will be presented at the conference.

Fredenburg, Jeff↗

Evaluating Radiation Impact on Transmon Qubits in Above and Underground Facilities

Superconducting qubits can be sensitive to abrupt energy deposits caused by cosmic rays and ambient radioactivity. Previous studies have focused on understanding possible correlated effects over time and distance due to cosmic rays. In this study, for the first time, we directly compare the response of a transmon qubit measured initially at the Fermilab SQMS above-ground facilities and then at the deep underground Gran Sasso Laboratory (INFN-LNGS, Italy). We observe same average qubit lifetime T$_1$ of roughly 80 microseconds at above and underground facilities. We then apply a fast decay detection protocol and investigate the time structure, sensitivity and relative rates of triggered events due to radiation versus intrinsic noise, comparing above and underground performance of several high-coherence qubits. Using gamma sources of variable activity we calibrate the response of the qubit to different levels of radiation in an environment with minimal background radiation. Results indicate that qubits respond to a strong gamma source and it is possible to detect particle impacts. However, when comparing above and underground results, we do not observe a difference in radiation induced-like events for these sapphire and niobium-based transmon qubits. We conclude that the majority of these events are not radiation related and to be attributed to other noise sources which by far dominate single qubit errors in modern transmon qubits.

Roy, Tanay↗

A 32-Channel Cryo-CMOS ASIC for SNSPD Biasing and Readout with Picosecond Timing

Superconducting nanowire single-photon detectors (SNSPD) are a promising technology for particle detection. Although SNSPDs have demonstrated picosecond timing accuracy, scaling up large arrays has proved challenging. In this work, we introduce a 32-channel cryo-CMOS application-specifc integrated circuit (ASIC) that can be tightly integrated with SNSPD arrays. The ASIC is designed to operate at a temperature of 4K and can perform up to 32 simultaneous timing measurements with a root-mean-square (RMS) accuracy of 8.0ps. The ASIC includes on-chip circuitry for externally biasing superconducting devices, low-noise amplifers for reading superconducting devices, high-resolution time-to-digital converters (TDC) for time-tagging events, and serializers for transmitting data to room-temperature electronics. The ASIC is manufactured in a 22nm FDSOI process and occupies an area of 4.0mm x 1.0mm. The performance of the ASIC was verifed using custom cryogenic device models internally developed for the 22nm SOI process. Measurement results will be presented at the conference.

Fredenburg, Jeff↗