Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “outdoor testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Review of Potential–Induced Degradation in Bifacial Photovoltaic Modules

Bifacial modules are increasingly deployed in the field and are expected to represent half of the market share within 10 years. Their rear structure differs from monofacial modules to allow additional light absorption. However, it brings new reliability challenges to address. In particular, the risk of potential-induced degradation (PID) is increased as both module sides are impacted. Different PID processes have been identified in the literature: shunting type (PID-s), polarization type (PID-p), Na penetration type, and corrosion type (PID-c). Their occurrence depends on the photovoltaic system configuration as well as the module's materials. Apart from PID-s, PID processes are not well understood and extensive research is needed to elucidate the PID scenario and underlying mechanisms. Herein, current knowledge about PID processes and their impact on the main bifacial modules in the market are gathered with the aim to guide future research. Bifacial module technologies and leakage current paths leading to PID are described. Indoor and outdoor PID testing methods are detailed. For each bifacial module technology, the PID processes are investigated with their indicators, mechanism and recovery process. Furthermore, PID-impacting factors and limitation solutions are finally reported and a state of the art on PID modeling is presented.

14 SOLAR ENERGY↗

FY23 Update: Aerosol Sampling for the Canister Deposition Field Demonstration

This report describes the results of preliminary testing of aerosol monitoring equipment that will be used to continuously monitor the aerosol source term for the multi-year Canister Deposition Field Demonstration (CDFD). These data are required inputs for the development and validation of models for the deposition of dust and potentially corrosive salts on the surface of spent nuclear fuel (SNF) dry storage canisters. Surface salt loads correlate with the extent of corrosion damage on a metal surface, and potentially to the likelihood and timing of initiation of stress corrosion cracks. Aerosols will be monitored at the CDFD site using three instruments. A Dekati ® ELPI+ cascade impactor will be used for real-time monitoring of aerosol particle sizes. It will also collect dust in 14 size bins on impactor targets that can be chemically analyzed to determine the soluble salts present as a function of particle size. However, this instrument can only measure dried aerosols, with a diameter of <10 µm. The second instrument is a Topas laser particle size spectrometer, which provides real-time monitoring of aerosol particle sizes up to ~40 µm in size. It monitors both the ambient (potentially deliquesced) aerosol particle size distributions required for the dust deposition models and the distributions of the equivalent dried particles, allowing correlation with the Dekati ® data. However, it does not discriminate between inert dust particles and salt aerosols, and it does not retain samples of the different particle sizes for later analysis. The third instrument that will monitor aerosols at the CDFD site is a Clean Air Status and Trends Network (CASTNET) tower, which uses a multiple canister system to collect weekly samples for analysis to total suspended aerosol particle compositions and atmospheric gas concentrations. This status report describes work in FY23 to develop the capabilities for using these tools. In two training exercises, the cascade impactor and laser particle sizer were deployed in two different testing environments, one indoor and one outdoor. For the cascade impactor, the tests provided opportunities for the operators to familiarize themselves with impactor substrate preparation, and post-test sample removal and analysis. For the laser particle sizer, the tests were used to evaluate different instrument parameters, to determine the most appropriate settings for capturing transient events. Data and samples were collected for weeks to months for each test, and the results are presented here. In addition to the preliminary testing, contracts were developed with WSP Analytical Labs for sample preparation and analysis of the cascade impactor samples. The impactor tower from outdoor test was delivered to WSP and used to train the staff there in disassembly, sample extraction, sample analysis, and tower reassembly with new target substrates. These are tasks that WSP will be performing routinely for the CDFD project. The CASTNET system cannot be purchased or tested until an actual site has been selected for the CDFD test. Work for this FY has been restricted to preparation of contracts for purchasing the CASTNET tower, and for sample analysis, once the tower is in operation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Accelerated Stress Testing of Perovskite Photovoltaic Modules: Differentiating Degradation Modes with Electroluminescence Imaging

Herein, electroluminescence (EL) and thermal imaging are used to examine p–i–n metal halide perovskite (MHP) photovoltaic (PV) mini-modules (MA0.6FA0.4PbI3, 20 cells, 78 cm2) before and after indoor-accelerated stress testing or outdoor deployment. Distinct spatial patterns in the EL images emerge, which depend on the external stress conditions experienced by the mini-module. Imaging results highlight a distribution of dark speckle features that dominate after UV stress, attributed to widespread interfacial contact degradation. Lateral intensity gradients across cells dominate after thermal cycling (TC) stress, attributed to current crowding near scribe defects. While current–voltage analysis alone does not give full insight on the degradation process, this study shows that distinct degradation modes can be further defined by multimodal electro-optical imaging (i.e., EL combined with photoluminescence and dark lock-in thermography). Neither UV exposure nor TC-accelerated stress testing alone replicates the same degradation signatures observed after outdoor deployment, suggesting that multiple degradation modes occur under concurrent stressors outdoors. Finally, spatial characterization of degradation modes in MHP PV mini-modules before and after accelerated stress testing lays the groundwork for developing targeted accelerated stress testing procedures through comparison with outdoor aging.

14 SOLAR ENERGY↗

Reliability Evaluation of Bifacial and Monofacial Glass/Glass Modules with EVA and non-EVA Encapsulants

The market share for bifacial modules is projected to be doubled from 30% to 60% in the next ten years. For the monofacial crystalline silicon glass/backsheet (G/B) modules, extensive reliability data has been available for over 40 years. However, practically little/no long-term field or accelerated reliability test data is available for the new generation glass/glass (G/G) bifacial modules and glass/transparent (G/T) bifacial modules. Therefore, the primary motivation of this project was to identify the reliability strengths and weaknesses of new generation G/G modules compared to G/B modules. In this 3-year project, the goal was to objectively recommend the best construction materials for the new generation G/G (bifacial) modules through a systematic experimental approach with appropriate tasks including: Evaluation of field retrieved old-generation G/G modules; Inspection of new-generation G/G modules installed in the plants; Evaluation of new-generation G/G, G/B and G/T modules using EAST (Extended Accelerated Stress Testing), CAST (Combined Accelerated Stress Testing) and FAST (Field Accelerated Stress Testing); and, dynamic literature search and review. Major accomplishments and outcomes of this project are: Accomplishments: Evaluated more than 60 field retrieved modules and constructed and characterized more than 135 mini-modules with three substrate types (G, B, and T), two encapsulant types (EVA and POE), and two cell types (monofacial and bifacial) as well as evaluated more than 30 commercial G/G and G/B modules; Subjected all the modules to multitude characterization tests and various indoor and outdoor accelerated stress tests including FAST (Field Accelerated Stress Testing), EAST (Extended Accelerated Stress Testing), and CAST (Combined Accelerated Stress Testing) to identify and correlate the failure modes in both field and lab tests. Outcomes: Based on the accelerated test results and handling/mounting experience obtained in this project, the recommended best construction for the glass/glass modules is: “Framed GG modules with cut-cells and POE encapsulant (UVpass front; UVpass back).” However, from a statistical and manufacturing point of view (along with stakeholders surveys), the following cautionary notes are added to the above-mentioned recommendation: (i) Cut cells could introduce a higher level of manufacturing issues, including a higher number of cell interconnects; (ii) POE encapsulant is more expensive than EVA and could present a delamination risk and lower throughput during manufacturing due to lower adhesion strength. Other encapsulants, such as coextruded EPE (EVA/POE/EVA), are also recommended to be investigated. The potential public benefit of the proposed project is to present the strengths and weaknesses of glass/glass modules, so an informed procurement decision can be made.

14 SOLAR ENERGY↗

BENEFIT with Northeastern University: HVAC Hardware-in-the-Loop Experimental Testing of a Heat Pump and Air Conditioner

This dataset includes HVAC Hardware-in-the-Loop (HIL) experimental results for a single stage, SEER 16, HSPF 9.5, 3-ton single-speed air source heat pump with 15 kW of backup auxiliary heating tested in both cooling and heating mode, and a two stage, SEER 21, 2-ton central air conditioner tested in cooling mode for a set of outdoor temperatures and indoor setpoint temperatures. In addition to these tests, experimental tests focused on the operation of auxiliary heating for the heat pump for winter condition were also conducted. The laboratory experiments for transient testing of the heat pump and air conditioner were conducted using the two HIL systems in the Systems Performance Laboratory (SPL) at NREL’s Energy Systems Integration Facility (ESIF). Further information on laboratory design and capabilities of the SPL along with the architecture of HVAC HIL system can be found in: Sparn, B. F. 2018. Laboratory Resources and Techniques to Evaluate Smart Home Technology (No. NREL/CP-5500-71696). National Renewable Energy Laboratory (NREL), Golden, CO (United States). https://www.nrel.gov/docs/fy18osti/71696.pdf and the experimental setup and validation of HVAC HIL platform can be found in: Ramaraj, S. and Sparn, B. 2022. Validation of HVAC Hardware-In-the-Loop Simulation for Advanced Control Strategies in Smart Homes (No. NREL/CP-5500-82562). National Renewable Energy Lab (NREL), Golden, CO (United States). https://www.nrel.gov/docs/fy22osti/82562.pdf. These experimental results can be used to validate how we currently model the cycling behavior of heat pumps and air conditioners. Additionally, many demand response programs implement heat pump and air conditioner control by changing the thermostat set point – these data may also be used to verify our models for heat pump and air conditioner demand response control are implemented correctly. The Test_Matrix file describes all the indoor and outdoor test conditions for heat pump and air conditioner and the file names of data sets include information about the test conditions. A wide range of outdoor air temperatures were chosen to accommodate summer and winter conditions. In addition to operating the HVAC equipment with different outdoor temperatures, we also operate the system with different indoor temperature set points to represent different grid signals or different operating conditions. For cooling conditions, the baseline set point is 72°F. To represent Load Up signals, the setpoint is changed to 68°F. The Load Shed set point is 76°F. For heating conditions, the baseline set point was assumed to be 68°F. The Load add set point is 72°F and the Load shed set point is 64°F. The starting indoor temperature for cooling conditions was set ~2°F above the indoor setpoint temperature so that the equipment turned on quickly. Similarly, the initial indoor temperature was set ~2°F lower than setpoint for heating mode tests to ensure that heating began quickly. The return air temperature was assumed to be equal to the indoor setpoint temperature in all cases. The experimental data are sampled at 1-second intervals. The data from ecobee thermostat at 5-minute interval are resampled and added to the corresponding file. The content of each data set is as follows: • T_Return (C): Measured return air temperature [C] • T_Return_SP (C): Return air temperature setpoint from E+ model, sent to HIL [C] • T_Supply (C): Measured supply air temperature at evaporator outlet [C] • T_Outdoor (C): Measured outdoor air temperature [C] • T_Outdoor_SP (C): Outdoor air temperature setpoint from weather file, sent to HIL [C] • T_Indoor (C): Measured indoor air temperature [C] • T_Indoor_SP (C): Indoor air temperature setpoint from E+ model, sent to HIL [C] • Outdoor Unit Power (W): Measured power of the outdoor unit [W] • Indoor Unit Power (W): Measured power of the indoor unit [W] • Evaporator Airflow Rate (CFM): Measured evaporator or indoor unit airflow rate sent to E+ model [CFM] • Cooling/Heating Capacity (kW): Calculated cooling/heating capacity sent to E+ model [kW] • T_SP_Thermostat (C): Thermostat cooling/heating setpoint temperature [C] • T_Indoor_Thermostat (C): Thermostat indoor air temperature [C]

24 POWER TRANSMISSION AND DISTRIBUTION↗

Long-term impact of light- and elevated temperature-induced degradation on photovoltaic arrays

Low levelized cost of electricity (LCOE) has been identified as critical for widespread adoption of photovoltaics (PV) without subsidies. Maintaining decades-long high-energy production is often an under-recognized opportunity in meeting cost goals because component lifetimes are not fully quantified at the time of manufacture. Whereas certain standardized tests minimize risk of early failure, there is little guidance to quantitatively predict degradation (or lack thereof) over decades, based on accelerated tests. In this article, we move toward bridging the understanding between indoor accelerated tests and outdoor performance data, with the goal of predicting energy yield with enough accuracy to inform financial decisions. Light- and elevated temperature-induced degradation (LETID) in p-type Si modules is analyzed in terms of impact on long-term module performance and thus LCOE. A method to predict the progression of LETID, using fixed kinetic constants and a numerical solution to the basic reaction rate equations, is detailed. Predictions are compared against both published data and that new to this study. These data include both indoor accelerated tests and fielded modules. We use the results in financial models to derive LCOE of modules in different climates with varying amounts of LETID, including uncertainty. Cost models based on the predictions indicate that LETID has a significant and climate-dependent impact on LCOE. Finally, we show that - even given the uncertainties identified in the study - these financial calculations can provide useful guidance to quantify risk based on accelerated test results. The analysis serves as an example of developing a predictive approach to PV reliability using physics of failure.

14 SOLAR ENERGY↗

Photovoltaic fleet degradation insights

Abstract In the PV Fleet Performance Data Initiative, high‐frequency data from commercial and utility‐scale photovoltaic (PV) systems have been collected to examine performance loss rates (PLRs) at a fleet scale. To date, performance data from more than 7.2‐gigawatt (GW) capacity, 1700 sites and 19,000 inverters—approximately equivalent to 6% to 7% of the entire US PV market—have been collected. An overall PLR of −0.75%/year was found, which is in line with historical and recent findings. Tracked silicon (Si) and cadmium telluride (CdTe) performed comparably with all fixed‐tilt systems. Higher PLRs were found for hotter temperature zones; cooler climates exhibit a median −0.48%/year loss, which increases to −0.88%/year in hotter climates. High‐efficiency module technologies showed median PLRs in line with conventional Si technologies but demonstrated markedly different PLR behavior when filtered only for low‐light conditions <600 W/m 2 . Causes for this technology‐dependent behavior are under investigation.

14 SOLAR ENERGY↗

Evidence of Polarization‐Type Potential‐Induced Degradation (PID‐p) in the Field and Investigation of the Recovery Mechanism on Bifacial p ‐PERC Modules

This study investigates the polarization-type potential-induced degradation (PID-p) of bifacial glass/glass p-type passivated emitter rear contact (p-PERC) modules in the field and their recovery behavior. Modules were installed with three mounting configurations providing different albedo conditions. System voltage (–600, –1500, and +1500 V) was applied to the cell circuits, with respect to the grounded module frames. No degradation was observed for positively biased modules, but PID-p was identified on the rear side when cells are negatively biased, with maximum power dropping during the first days and stabilizing at values up to 8% loss. Electroluminescence images revealed a variation of the cells' PID-p susceptibility within a module. Three parameters were shown to impact the degradation rate: rear albedo light, voltage, and wetness conditions. Degraded modules were recovered either by (1) a positive bias (+1500 V), (2) outdoor illumination with the front side facing sun, (3) outdoor illumination with the rear side facing sun, or (4) dark storage. A recovery pattern was identified with I–V parameters decreasing to a local minimum before increasing to full recovery. The proposed mechanism is based on the band bending at the rear p-type Si/AlO x/SiN x interface, going from inversion to depletion and accumulation states. Full recovery was achieved in 2–7 h for the modules recovered with the rear side facing sun, four to eight nights for the modules positively biased at night, and 10–20 days for the modules with the front side facing sun. Dark storage showed slower recovery rates as I–V parameters were not improving even after 1 month. Here, the recovery rates were correlated with the net Coulombs transferred during the preceding PID stress: When more Coulombs are transferred during the degradation, the extent of degradation is greater, leading to slower recovery rates.

14 SOLAR ENERGY↗

Halophyte biorefinery for polyhydroxyalkanoates production from Ulva sp. Hydrolysate with Haloferax mediterranei in pneumatically agitated bioreactors and ultrasound harvesting

Here, the present study tested the outdoor cultivation of Haloferax mediterranei for PHA production from green macroalgae Ulva sp. in pneumatically agitated bioreactors and applied ultrasonic separation for enhanced settling of archaeal cells. Scaled-up cultivation (40 L) yielded maximum biomass productivity of 50.1 ± 0.11 mg·L -1 ·h -1 with a PHA productivity of 27 ± 0.01 mg·L -1 ·h -1 and conversion yield of 0.107 g PHA per gram UlvaDW. The maximum mass fraction of PHA achieved in biomass was calculated to be 56% w/w. Ultrasonic harvesting of Hfx. mediterranei cells approached 30% removal at energy inputs around 7.8 kWh·m -3 , and indicated no significant aggregation enhancement by Ca 2+ addition. Molecular weight analysis showed an increase in Polydispersity Index (PDI) when the corresponding air velocities were increased suggesting that the polymer was more homogeneous at lower mixing velocities. The current study demonstrated scalable processes for PHA production using Ulva sp. feedstock providing new technologies for halophilic biorefinery.

09 BIOMASS FUELS↗

Hybrid Tandem Photovoltaics

Tandem solar cell structures are the only strategy demonstrated to surpass the detailed balance efficiency limit of high-quality single-junction solar cells. To continue to improve the efficiencies of cost-effective terrestrial solar power, hybrid tandems of dissimilar subcells are being considered by many around the world, especially designs that incorporate silicon solar cells as a bottom subcell. In this project, we studied a wide variety of tandem design possibilities including those with three-terminal (3T) and four-terminal (4T) configurations. The use of 3T and 4T designs could be useful for efficient and economical hybrid tandem designs that utilize the best available subcell materials such as emerging perovskite materials. Three-terminal configurations, in particular, have not been sufficiently studied previously. We have laid the foundational groundwork in this project for understanding the operation of 3T tandems: developing a taxonomy for naming, a methodology for measuring and interconnecting, and models for simply characterizing 3T tandems. Electrical and optical subcell coupling between the subcells was also measured and modeled. An important part of this work was the fabrication of novel example tandem structures, including 4T GaAs/Si, 3T GaInP/Si, 3T GaAs/Si, and 3T GaInP/GaAs devices. Using these high-quality tandem cells, we have been able to clearly demonstrate the achievability of high-efficiencies, and subtle physical effects such as photon recycling and luminescent coupling. We have developed and demonstrated essential building-block tools such as transparent conductive adhesives (TCA) and 3T silicon bottom cells with interdigitated back contacts (IBC) that can also be used in many other tandem designs. We have tested the reliability of these tools and devices under standardized testing and outdoor measurements. We have found 4T GaAs/Si tandems to be relatively straightforward to fabricate and robust in real-world outdoor conditions. While we have demonstrated working hybrid 3T III-V/TCA/Si IBC tandems, we experienced low yields even with our best process flows yet. Further work is still needed to improve the processing yield of these devices. We therefore also created tandem cells using an all-III-V 3T tandem process which was very robust with high yields, allowing for the creation of voltage-matched strings in many different configurations using 8 nearly identical 3T tandems. Using these robust 3T tandem examples, we were able measure and precisely characterize 3T tandem behaviors to predict their operation under changing spectrum and temperature. The optoelectronic equivalent-circuit model was shown to be very general and applicable to hybrid tandems, and encompassed the operation 3T Si IBC cells. This general model has been distributed to the public in as open-source Python-based software called PVcircuit. We have calculated the implications of these new tandem device designs on the real-world energy production and shown how the relative performance of different tandem configurations is situational and can be engineered using the tools developed here.

14 SOLAR ENERGY↗

Methane Quantification Performance of the Quantitative Optical Gas Imaging (QOGI) System Using Single-Blind Controlled Release Assessment

Quantitative optical gas imaging (QOGI) system can rapidly quantify leaks detected by optical gas imaging (OGI) cameras across the oil and gas supply chain. A comprehensive evaluation of the QOGI system’s quantification capability is needed for the successful adoption of the technology. This study conducted single-blind experiments to examine the quantification performance of the FLIR QL320 QOGI system under near-field conditions at a pseudo-realistic, outdoor, controlled testing facility that mimics upstream and midstream natural gas operations. The study completed 357 individual measurements across 26 controlled releases and 71 camera positions for release rates between 0.1 kg Ch 4 /h and 2.9 kg Ch 4 /h of compressed natural gas (which accounts for more than 90% of typical component-level leaks in several production facilities). The majority (75%) of measurements were within a quantification factor of 3 (quantification error of –67% to 200%) with individual errors between –90% and 831%, which reduced to –79% to +297% when the mean of estimates of the same controlled release from multiple camera positions was considered. Performance improved with increasing release rate, using clear sky as plume background, and at wind speeds ≤1 mph relative to other measurement conditions.

42 ENGINEERING↗

An Open-Source Python Library for Modeling LETID and LID in Silicon Solar Cells and Wafers

This poster demonstrates an (in development) open-source software library, written in python, to aid in modeling and understanding light- and elevated temperature-induced degradation (LETID) and boron-oxygen light-induced degradation (B-O LID) in silicon solar cells and wafers. We discuss the underlying equations and necessary input parameters for constructing realistic models. We demonstrate several use cases for the library, including modeling LETID progression in scenarios like indoor, accelerated tests and outdoor field deployment. We also demonstrate using the library to model B-O LID, and we demonstrate using the library to model degradation in passivated wafers, rather than solar cells.

LETID↗

Intraday Outdoor Efficiency Changes in Metal-Halide Perovskite Photovoltaic Modules

Here, we present outdoor observations of metal-halide perovskite modules deployed in the Photovoltaic Accelerator for Commercializing Technologies center, which houses one of the world's broadest efforts to test metal-halide perovskite photovoltaic modules outdoors. As of January 2025, outdoor testing has encompassed over 150 modules from 14 different partners. Our findings illustrate how daily changes in efficiency, driven by exposure to light, affect field performance in real-world conditions. These effects cannot be explained by existing outdoor performance models and frustrate the notion of a traditional temperature coefficient.

14 SOLAR ENERGY↗

Novel Algae Technology to Utilize CO 2 for Value Added Products

The Helios-NRG technology for converting coal-based flue CO 2 into valuable products has been successfully validated through a series of rigorous test programs. The key component, the MSC (Multi Stage Continuous System), played a pivotal role in this process. The MSC's various stages were seamlessly integrated and controlled by a second-generation automated system, surpassing project goals in terms of both algal productivity and capture efficiency. Notably, the MSC's operational duration improved while maintaining healthy cultures. The integrated system was rigorously tested under real outdoor conditions with varying sunlight levels and template flue gas. The final MSC test, conducted at the NCCC, successfully met project objectives.

01 COAL, LIGNITE, AND PEAT↗

Towards linking lab and field lifetimes of perovskite solar cells

Metal halide perovskite solar cells (PSCs) represent a promising low-cost, thin-film photovoltaic (PV) technology, with unprecedented power conversion efficiencies (PCEs) obtained for both single-junction and tandem applications. To push PSCs toward commercialization, it is critical, albeit challenging, to understand device reliability under real-world outdoor conditions where multiple stress factors (e.g., light, heat, humidity) coexist, generating complicated degradation behaviors. It is necessary to identify accelerated indoor testing protocols - which can correlate specific stressors with observed degradation modes in fielded devices - to quickly guide PSC development. Here, we use a state-of-the-art p-i-n PSC stack (with PCE up to ~25.5%) to show that indoor accelerated stability tests can predict our 6-month outdoor aging tests. Device degradation rates under illumination and at elevated temperatures are most instructive for understanding outdoor device reliability. Further, we also find that the indium tin oxide (ITO)/self-assembled monolayer (SAM)-based hole transport layer (HTL)/perovskite interface most strongly affects our device operation stability. Improving the ion-blocking properties of the SAM HTL increases averaged device operational stability at 50 degree C-85 °C by a factor of ~2.8, reaching over 1000 h at 85 °C and to near 8200 h at 50 °C with a projected 20% degradation, which is among the best to date for high-efficiency p-i-n PSCs.

14 SOLAR ENERGY↗

A study of degradation mechanisms in PVDF-based photovoltaic backsheets

Abstract Commercial backsheets based on polyvinylidene fluoride (PVDF) can experience premature field failures in the form of outer layer cracking. This work seeks to provide a better understanding of the changes in material properties that lead to crack formation and find appropriate accelerated tests to replicate them. The PVDF-based backsheet outer layer can have a different structure and composition, and is often blended with a poly(methyl methacrylate) (PMMA) polymer. We observed depletion of PMMA upon aging with sequential (MAST) and combined (C-AST) accelerated stress testing. In field-aged samples from Arizona and India, where PVDF crystallizes in its predominant α-phase, the degree of crystallinity greatly increased. MAST and C-AST protocols were, to some extent, able to replicate the increase in crystallinity seen in PVDF after ~ 7 years in the field, but no single-stress test condition (UV, damp heat, thermal cycling) resulted in significant changes in the material properties. The MAST regimen used here was too extreme to produce realistic degradation, but the test was useful in discovering weaknesses of the particular PVDF-based outer layer structure studied. No excessive β-phase formation was observed after aging with any test condition; however, the presence of β-phase was identified locally by Fourier transform infrared spectroscopy (FTIR). We conclude that both MAST and C-AST are relevant tests for screening outdoor failure mechanisms in PVDF backsheets, as they were successful in producing material degradation that led to cracking.

14 SOLAR ENERGY↗

CSP Optical Facilities at the National Renewable Energy Laboratory

The concentrating Solar Power (CSP) Optical Facilities at NREL comprise unique optical tools and facilities for testing and characterizing concentrating solar optical components. These facilities are maintained to aid researchers and industry efforts to reduce market barriers, improve the performance, reduce the cost, and improve the lifetime and reliability of CSP materials, components, subsystems, and integrated concepts, where accurate and timely characterization methods are needed. To reach this goal, NREL is committed to collaborating in ongoing and projected research needs for industry, academia, and government entities, in the development and characterization of low-cost, high-performance reflector and absorber materials in addition to their components-a key element in the conversion of concentrated sunlight into energy. To accomplish this mission, the core laboratory includes the Advanced Optical Materials Laboratory, indoor and outdoor accelerated weather testing tools, "Distant Observer" for parabolic troughs, the High Flux Solar Furnace, and the ultra-accelerated weather testing tools. This equipment enables to rapidly respond to new challenges with novel solutions that align with the goals of the Solar Energy Technology Office (SETO) at the U.S. Department of Energy. The goal of this paper is to present the state-of art-optical facilities available at NREL that can help support the research needs of the CSP community. Therefore, we review here the different components of the CSP Optical Facilities at NREL and highlight their characteristics and importance for the CSP community.

accelerated weather testing↗

Medium-Voltage Testbed for Comparing Advanced Power Line Sensors vs. Measurement Transformers with Electrical Grid Events

Electrical utilities have relied upon potential transformers (PTs) and current transformers (CTs) for very accurate metering and to provide reliable signals for protective relays. Less expensive alternative sensing technologies offer the possibility of wider deployment, particularly in grids that employ distributed energy resources. In this work, the performance of an advanced medi-um-voltage sensor is compared with a reference PT and CT and experimentally evaluated for different power grid scenarios on an advanced outdoor power line sensor testbed at the US De-partment of Energy’s Oak Ridge National Laboratory. The sensor is based on a capacitive divider for voltage monitoring and a Rogowski coil with integrator for current monitoring. The advanced outdoor power line sensor testbed has a real-time simulator that was used to generate transient scenarios (e.g., electrical faults, capacitor bank operation, service restoration), while the analog signals were recorded by the same high resolution power meter. The behavior of analog signals, harmonic components, total harmonic distortion, and crest factors were assessed for this power line sensor compared with the reference PT/CT, because of the absence for testing standards for advanced outdoor power line sensors.

Piesciorovsky, Emilio↗