Decoding Resilience by Modeling Outage and Restoration Processes in Distribution Grids: A Pittsburgh Case Study

Climate-induced extreme weather events, such as floods and heatwaves, pose significant challenges to the resilience of urban power distribution grids. This paper examines the outage and restoration dynamics of Pittsburgh's power grid during the flood event in April 2024 and three heatwaves in June, July, and August 2024. We introduce a comprehensive modeling framework that integrates outage and restoration processes, enabling the quantification of resilience metrics, including total customer-hours of power outage, maximum residual values, and restoration durations across various ZIP codes. Our analysis highlights spatial disparities in outage impacts and restoration efficiencies, with ZIP Code 15222 experiencing the highest cumulative disruptions, while ZIP Code 15217 shows lower susceptibility. By linking statistical trends with weather events, this study underscores the critical need for targeted infrastructure upgrades and advanced restoration strategies. Furthermore, the proposed framework offers valuable insights for planning and managing resilient power systems in the face of increasing climate stress.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Historical Power Outages of the United States and the Social Vulnerability Index

Several works have been documented in the literature to study the societal effect of power outages and to analyze their correlation with the Social Vulnerability Index (SVI). Because the SVI is calculated based on the summed rank of multiple vulnerability factors for environmental hazards, it can include factors irrelevant to power outages caused by extreme events. This work performs a detailed correlation analysis for social vulnerability and power outages by considering different SVI themes (e.g., socioeconomic status, household composition, racial and ethnic minority status, and housing and transportation) and power outages with and without a threshold for extreme weather events. Although there is some relation between specific themes and aspects of power outages and the SVI in the results, there is no strong distinction between power outage durations and low vs. high SVI values. These results point to the need for further research that grounds the specific factors and methods used to develop SVI and related indices to energy services and power systems disruptions.

Bhusal, Narayan↗

Validating Protection System Behavior with Machine Learning in a Master State Overseer

As power system protection devices continue the widespread transition from analog to digital, they become increasingly intricate. The internal functions and communication between critical grid components must now be significantly more complex to keep up with the demands of the modern smart grid. This brings increased difficulty in maintenance and monitoring, making it harder to identify potential misoperation, power anomalies, and cyber threats. Such issues are often only pinpointed after an exhaustive and costly post-mortem analysis, when a major outage or damage has already occurred. A solution is needed for validating protection systems as they operate, independently evaluating grid state and confirming whether the protection system is behaving accordingly. As opposed to incident response, this acts as a constant verification mechanism that raises a flag when subtler issues are noticed, catching them earlier and preventing larger incidents. This work presents the implementation of such a system, expanding on the prototype developed by the authors in a previous paper. This is accomplished with a machine learning (ML) system capable of validating the performance of protection systems by classifying anomalous events and characterizing protection system responses based solely on available current and voltage measurements. Additionally, this system is contextualized within a larger, modular Master State awareness Overseer (MSO) framework, responsible for monitoring, analyzing, and managing an electric grid.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Resilient cooling strategies – A critical review and qualitative assessment

The global effects of climate change will increase the frequency and intensity of extreme events such as heatwaves and power outages, which have consequences for buildings and their cooling systems. Buildings and their cooling systems should be designed and operated to be resilient under such events to protect occupants from potentially dangerous indoor thermal conditions. This study performed a critical review on the state-of-the-art of cooling strategies, with special attention to their performance under heatwaves and power outages. We proposed a definition of resilient cooling and described four criteria for resilience—absorptive capacity, adaptive capacity, restorative capacity, and recovery speed —and used them to qualitatively evaluate the resilience of each strategy. The literature review and qualitative analyses show that to attain resilient cooling, the four resilience criteria should be considered in the design phase of a building or during the planning of retrofits. The building and relevant cooling system characteristics should be considered simultaneously to withstand extreme events. A combination of strategies with different resilience capacities, such as a passive envelope strategy coupled with a low-energy space-cooling solution, may be needed to obtain resilient cooling. Finally, a further direction for a quantitative assessment approach has been pointed out.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Analysis of Correlation between Cold Weather Meteorological Variables and Electricity Outages

The significance of the impact of weather on the electric grid has grown as climate change continues to increase the frequency and intensity of extreme weather events. In recent years (2021-2022) in particular, extreme winter weather has affected the grid in locations in the US rarely exposed to extreme low temperatures, snow and icing conditions. Here we analyze the correlation between cold weather meteorological variables and electricity outages during two large winter storm events, Uri (February 2021) and Landon (February 2022) using Random Forest machine learning and Pearson’s correlation coefficient. Our geographical focus across the two storms is the state of Texas. Extrapolation of the method to winter weather impacts over other years and additional locations is proposed.

Dumas, Melissa↗

Reliability of emergency and standby diesel generators: Impact on energy resiliency solutions

Emergency diesel generators are the most common form of backup power for critical loads when the grid fails and are most often deployed as stand-alone generators (<2000 kW) tied to individual buildings for hospitals, emergency services, military bases, ports, airports, industries, and commercial facilities. Understanding the finite reliability of emergency diesel generators during continuous operation is critical for energy planners, managers, and end-users. A new analysis of two large non-public emergency diesel generator operational data sets shows that commonly used reliability metrics are inadequate to predict the performance during a grid outage. Additional metrics addressing the likelihood of an emergency diesel generator to be available at the time an outage starts, successfully start and carry load, and constantly run for the duration of the outage are needed to predict the continuous run-time reliability of emergency diesel generators during a grid outage. This is the first analysis of the reliability of modern generators that follow standard maintenance protocols commonly used for backup power and these new metrics are shown to be dependent on the level of emergency diesel generator maintenance with values that can vary by more than an order of magnitude. Even using the new metrics for well-maintained emergency diesel generators, the analysis shows that the single emergency diesel generators configurations are only 80% likely to provide power for the duration of a two-week grid outage.

ENERGY PLANNING, POLICY, AND ECONOMY,POWER TRANSMI↗

Correlating Power Outage Spread with Infrastructure Interdependencies During Hurricanes

Power outages caused by extreme weather events, such as hurricanes, can significantly disrupt essential services and delay recovery efforts, underscoring the importance of enhancing our infrastructure's resilience. This study investigates the spread of power outages during hurricanes by analyzing the correlation between the network of critical infrastructure and outage propagation. We leveraged datasets from Hurricanemapping.com, the North American Energy Resilience Model Interdependency Analysis (NAERM-IA), and historical power outage data from the Oak Ridge National Laboratory (ORNL)'s EAGLE-I system. Our analysis reveals a consistent positive correlation between the extent of critical infrastructure components accessible within a certain number of steps (k-hop distance) from initial impact areas and the occurrence of power outages in broader regions. This insight suggests that understanding the interconnectedness among critical infrastructure elements is key to identifying areas indirectly affected by extreme weather events.

Bose, Avishek↗

Understanding the Computing and Analysis Needs for Resiliency of Power Systems from Severe Weather Impacts

As the frequency and intensity of severe weather has increased, its effect on the electric grid has manifested in the form of significantly more and larger outages in the United States. This has become especially true for regions that were previously isolated from weather extremes. In this paper, we analyze the weather impacts on the electric power grid across a variety of weather conditions, draw correlations, and provide practical insights into the operational state of these systems. High resolution computational modeling of specific meteorological variables, computational approaches to solving power system models under these conditions, and the types of resiliency needs are highlighted as goal-oriented computing approaches are being built to address grid resiliency needs. An example analysis correlating outages to 1km day-ahead weather from two historical winter storms, calculated on a large cluster using a combination of interpolated and extrapolated inputs from multiple instrumented sites to workflows that produce primary meteorological outputs, is shown as initial proof of concept.

analysis↗

AGGREGATE: dAta-driven modelinG preservinG contRollable dEr for outaGe mAnagemenT and rEsiliency (Report for Task 10: Controllability and Observability Analysis (Deliverable D7))

It is common to have less than full observability for distribution systems, as the number of available measurements are not sufficient. Considering increasing penetration of distributed energy resources (DERs), it is imperative to understand and control distribution systems better. Developed for the transmission system, the original numerical observability analysis methods were based on the canonical DC Power Flow (DC-PF) model. However, the DC-PF model is ill-suited for the distribution system in which line resistance to reactance (R/X) ratios can be near unity. In this report, we apply the non-iterative Observability Test (OT) and Observable Island Identification Procedure (OIIP) in to the gain matrix from the distribution system state estimator. Because sensors are few in distribution systems, pseudo-measurements based on historical load profiles and zero-injection virtual measurements are often employed to ensure observability. However, both the observability and the accuracy of the state estimates are uncertain when historical data is limited/unavailable.

42 ENGINEERING↗

Summary: Techno-Economic Analysis of Solar Photovoltaics and Battery Energy Storage at a Vietnam Industrial Park

The Clean Energy Investment Accelerator conducted a case study analysis of battery energy storage system (BESS) feasibility for an industrial park in Vietnam using the National Renewable Energy Laboratory's (NREL's) REopt platform (a distributed energy modeling and optimization tool) to evaluate how BESS may reduce electricity costs, increase utilization of onsite renewable energy generation, and improve resilience to utility grid outages. This presentation summarizes the analysis and key takeaways.

batteries↗

Assessing the energy equity benefits of energy storage solutions

Safety, reliability, efficiency, and affordability are no longer the sole tenets of electric grid planning. The evolving social and policy climate have placed new explicit requirements on the electric grid, including resilience, decarbonization, and energy equity and justice. Integrating energy equity strategies into modern grid design is intended to achieve a fair and just distribution of benefits within the energy system. This study aims to characterize the energy equity and community benefits of energy storage systems (ESS) under the following three use-case models: utility ESS that are operated within the distribution system; community-owned ESS; and behind-the-meter ESS that are customer-owned to serve the household. The goal of this energy equity analysis is to characterize the environmental, economic, and social benefits of ESS through applied metrics such as energy burden, energy poverty, energy vulnerability, job creation, and more. A 13.8 kV, 265 node representative feeder corresponding to the hot-humid climate of Louisiana, chosen for its high energy burden, frequent hurricanes and outage events, was used to perform a storage adequacy analysis for six different outage scenarios to determine energy storage access for each use-case. The results of this analysis are then used to characterize both the grid and equity benefits of storage solutions to inform a prioritization framework matching community needs with system preferences for utility planning processes, market regulations, and the wider network of energy system stakeholders.

Energy Equity, energy justice, equity, reliability↗

Protection System Validation Using Post-Event Anomaly Classification with Machine Learning

Power system protection devices have transitioned over the past few decades from mechanical to analog devices, then to solid state and finally digital. Relays and their associated critical network of equipment have significantly increased in complexity. Even internally, relays have gained significant intricacy, with relatively simple overcurrent or differential functions now being assisted by a myriad of other functions. This is necessary as the grid becomes more complex, but it brings increased difficulty in monitoring and upkeep. Misoperation caused by improper relay settings or malicious actions is a constant challenge faced by all utilities. These improper settings can be difficult to identify and may require exhaustive post-mortem analysis, typically after a major outage event has already occurred. A mechanism is needed for monitoring the behavior of protection systems to validate that they act and perform as expected. This work presents a concept for a machine learning (ML) system capable of validating the performance of protection systems by classifying anomalous events and characterizing protection system responses based solely on available current and voltage measurements. As a first step in its development, an experimental dataset is generated, and a random forest model is implemented with high accuracy in distinguishing four power system scenarios.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Post-Event Fault Identification with Machine Learning for Protection System Validation

Power system protection devices have transitioned over the past few decades from mechanical to analog devices, then to solid state and finally digital. Relays and their associated critical network of equipment have significantly increased in complexity. Even internally, relays have gained significant intricacy, with relatively simple overcurrent or differential functions now being assisted by a myriad of other functions. This is necessary as the grid becomes more complex, but it brings increased difficulty in monitoring and upkeep. Misoperation caused by accidental improper relay settings or deliberate malicious actions is a constant challenge faced by all utilities. These improper settings can be difficult to identify and may require exhaustive post-mortem analysis, typically after a major outage event has already occurred. A mechanism is needed for monitoring the behavior of protection systems to validate that their performance falls within expectations. Relays that fail to isolate a fault or trip when there is no system disturbance can be flagged for settings review in situations where this behavior may not have been noticed due to manual restoration or backup protection operations. This work presents a concept for a machine learning (ML) system capable of validating the performance of protection systems by identifying fault events and characterizing protection system responses based solely on available current and voltage measurements. As a first step in its development, an experimental dataset is generated, and a random forest model is implemented with high accuracy in distinguishing four power system scenarios.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Residential Vehicle-to-Home Backup Power Capabilities: Key Findings from a ComEd Beneficial Electrification R&D Pilot

This report summarizes key findings from a collaborative technical study of residential, non-grid-tied vehicle-to-home (V2H) backup power systems in Commonwealth Edison’s (ComEd’s) service territory. The work integrates (1) a feeder-level technoeconomic analysis (TEA) using historical outage-event data and simulated electric-vehicle (EV) driving/charging profiles to estimate potential reliability and customer interruption-cost impacts under V2H and vehicle-to-grid (V2G) adoption scenarios; (2) controlled laboratory performance testing of a representative V2H backup ecosystem to characterize transfer-to-backup behavior, sustained power delivery, efficiency trends, and repeatable reliability limitations; and (3) a cybersecurity assessment aligned with NIST Cybersecurity Framework (CSF) 2.0 and ISO/SAE 21434 to evaluate interface-level risk drivers and identify program-relevant mitigations. Results indicate that V2H can provide measurable resilience value, but outcomes are strongly context dependent on outage patterns and the share of events that are “V2H-applicable.” Typical transfer-to-backup behavior clustered on the order of minutes, but rare long-delay edge cases were observed (including an event approaching 30 minutes) and should be treated as a reliability risk. High-power testing showed that peak-rated output is not necessarily continuously deliverable; stable operation may require operation below nameplate ratings and attention to thermal and installation constraints. The cybersecurity assessment highlights a broad attack surface spanning commissioning, home networks, embedded services, and cloud/OTA pathways, motivating minimum controls for secure onboarding, signed updates, patch cadence, and coordinated vulnerability response for any scaled deployment.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Power Outage Data Informed Resilience Assessment Framework

Catastrophic impacts to power systems due to disruptive events have increased significantly during the last decade. These events highlight the need to develop approaches to assess the resilience of power systems against extreme events. However, the availability of data that capture power system performance during and after disruptive events is scarce. This paper proposes an assessment framework to evaluate the performance aspects of the grid system during extreme outage events using the Environment for Analysis of Geo-Located Energy Information (EAGLE-I) data. EAGLE-I includes information related to the number of impacted customers, duration, and location of power outages in the United States. Statistical analyses were conducted to extract resilient-based outage data and derive probability distribution functions of their impact and recovery characteristics. A list of extreme events is identified based on few predetermined threshold values. Metrics from other power outage assessments were used to measure the characteristics of each event, including impact rate and duration, recovery rate and duration, and impact level. A probability distribution function is obtained for each metric. The obtained results provide a representation of national grid performance during extreme events, which can be applied as a framework to evaluate various resilience enhancement techniques.

EAGLE-I↗

Probabilistic Resilience of DER Systems - A Simulation Assisted Optimization Approach

Energy systems resilience is becoming increasingly important as the frequency of major grid outages increases. In this work, we present a methodology to optimize a behind-tlie-meter distributed energy resource system to sustain a site's critical loads during a pre-defined outage period. With the fixed system design, we then propose an outage simulation approach to estimate the resilience potential of the DER system to sustain loads beyond the fixed outage period - a yearlong resilience performance analysis. We apply statistical analysis to assess the system's resilience performance over a broader parametric problem space on an hourly, monthly, and yearly basis. We demonstrate the impact of the pre-defined outage period on the resilience performance through a case study. Results show that the probability of surviving a random outage of a given duration changes from 20% to 95% when the outage is modeled for a weekday instead of a weekend for the given load-profile.

28 EE - Advanced Manufacturing Office (EE-5A)↗

Strategies for Flood Resilience and Grid Investment Among Iowa's Electric Distribution Utilities

Flooding poses a growing threat to Iowa's electric distribution system, yet utilities face significant data and modeling challenges in planning effective resilience investments. This report provides a foundational assessment of how distribution utilities in Iowa, investor-owned, municipal, and cooperative, approach resilience planning, with a focus on flood risk. It combines hazard characterization, review of state and utility practices, and application of NLR's Energy Resilience Analysis for Distribution Systems (ERAD) and Capacity Expansion Decision Support for Distribution Networks (CADET) tools. Using FEMA floodplains, Iowa Flood Center depth grids, and utility infrastructure data, the analysis quantifies asset exposure, simulates outage risks, and evaluates resilience strategies such as pole hardening, undergrounding, and substation protection. Results indicate that while feeder-level upgrades provide incremental benefits, the most significant reductions in outage risk are achieved through targeted substation interventions. The report highlights key data gaps, such as limited elevation data and fragility functions, and underscores the need for probability-weighted investment frameworks to address both frequent and catastrophic flood events. These insights aim to support utilities, state agencies, and federal partners in prioritizing resilience investments that safeguard Iowa's electric grid against future flooding.

24 POWER TRANSMISSION AND DISTRIBUTION↗