Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “oscillation source location”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Latest Results from the NOvA Experiment

NOvA, is a two-detector, long-baseline neutrino oscillation experiment located at Fermilab, Batavia, IL, USA. The NOvA experiment was designed primarily to constrain neutrino oscillation parameters by analyzing $\nu_\mu (\bar{\nu}_\mu)$ disappearance and $\nu_e (\bar{\nu}_e)$ appearance data observed at the far detector. The Neutrinos at Main Injector (NuMI) beamline at Fermilab provides a high purity beam of neutrinos and anti-neutrinos to the experiment. The NOvA experiment consists of two functionally identical, finely granulated liquid tracking calorimeters, both situated 14.6 mrad off-axis to the beam direction. The NOvA near detector, situated 100 meters underground and 1 kilometer from the beam source, detects the non-oscillated $\nu_\mu (\bar{\nu}_\mu)$ and beam $\nu_e (\bar{\nu}_e)$ events. The far detector, located in Ash River, MN, USA, 810 kilometers from the beam source, records the non-oscillated $\nu_\mu (\bar{\nu}_\mu)$ and the oscillated $\nu_\mu (\bar{\nu}_\mu) \to \nu_e (\bar{\nu}_e)$ events. The latest results on standard 3-flavor neutrino oscillations, joint NOvA-T2K analysis, active-to-sterile neutrino mixing, and non-standard interactions will be presented in this talk.

43 PARTICLE ACCELERATORS↗

Latest Constraints on Three-Flavor Neutrino Oscillation Parameters from the NOvA Experiment.

NOvA, is a two-detector, long-baseline neutrino oscillation experiment located at Fermilab, Batavia, IL, USA. The NOvA experiment was designed primarily to constrain neutrino oscillation parameters by analyzing $\nu_\mu (\bar{\nu}_\mu)$ disappearance and $\nu_e (\bar{\nu}_e)$ appearance data observed at the far detector. The Neutrinos at Main Injector (NuMI) beamline at Fermilab provides a high purity beam of neutrinos and anti-neutrinos to the experiment. The NOvA experiment consists of two functionally identical, finely granulated liquid tracking calorimeters, both situated 14.6 mrad off-axis to the beam direction. The NOvA near detector, situated 100 meters underground and 1 kilometer from the beam source, detects the non-oscillated $\nu_\mu (\bar{\nu}_\mu)$ and beam $\nu_e (\bar{\nu}_e)$ events. The far detector, located in Ash River, MN, USA, 810 kilometers from the beam source, records the non-oscillated $\nu_\mu (\bar{\nu}_\mu)$ and the oscillated $\nu_\mu (\bar{\nu}_\mu) \to \nu_e (\bar{\nu}_e)$ events. The most recent measurements of three flavor neutrino oscillation parameters based on an analysis of the data collected from neutrino-beam exposure of $26.60 \times 10^{20}$ POT and anti-neutrino beam exposure of $12.50\times 10^{20}$ POT including an additional low energy $\nu_e$ sample, will be presented in this talk.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

'Intermittent' solar periodicities

The signal from a stable periodicity can seem to be intermittent when it is partially masked by an unmodelled window function or when the data set is too short to resolve closely spaced periodicities. By taking this into account, short-lived periodicities in solar data can be reinterpreted as evidence for continuously periodic behavior. The periodic sources are located in the solar interior and caused by global oscillation modes. The convective envelope acts as the window for these sources. Recent reports of seven periodicities from 100 to 1000 days are compared with this model. Precise long-term values for the periodicities are predicted and they agree closely with observations. Some elements are suggested that might explain the well-documented 155-day periodicity. Conventional filtering methods to suppress effects of the 11-year cycle are criticized as inadequate.

Wolff, Charles L.↗

Constructing Data-Driven Predictions at the Far Detector for NOvA's Neutrino Oscillation Analysis.

NOvA, is a two-detector, long-baseline neutrino oscillation experiment located at Fermilab, Batavia, IL, USA. It is designed primarily to constrain neutrino oscillation parameters using $\nu_\mu \ (\bar{\nu}_\mu)$ disappearance and $\nu_e \ (\bar{\nu}_e)$ appearance data. The Neutrinos at Main Injector (NuMI) beamline at Fermilab provides a high purity 900 KW intense beam of neutrinos and anti-neutrinos to NOvA. The NOvA Near Detector, located 100m underground and 1km away from the beam source, observes the un-oscillated $\nu_\mu \ (\bar{\nu}_\mu)$ and beam $\nu_e \ (\bar{\nu}_e)$ event spectrum. The Far Detector, located in Ash River, MN, USA, is 809 km from the ND and records the oscillated $\nu_e \ (\bar{\nu}_e)$ and the un-oscillated $\nu_\mu \ (\bar{\nu}_\mu)$ event spectrum. NOvA uses a data-driven technique called extrapolation to predict the expected number of $\nu_\mu \ (\bar{\nu}_\mu)$ and $\nu_e \ (\bar{\nu}_e)$ events at the Far Detector using the Near Detector data. The use of data from a functionally equivalent Near Detector provides a powerful constraint on the systematic uncertainties in NOvA neutrino oscillation analyses. As NOvA continues to add data statistics, a robust constraint on systematics becomes more crucial for neutrino oscillation analysis. The details of the NOvA neutrino oscillation analysis framework and how it constrains dominant systematic uncertainties using the Near Detector data will be discussed in this poster.

43 PARTICLE ACCELERATORS↗

Remote Sensing and Quantization of Analog Sensors

This method enables sensing and quantization of analog strain gauges. By manufacturing a piezoelectric sensor stack in parallel (physical) with a piezoelectric actuator stack, the capacitance of the sensor stack varies in exact proportion to the exertion applied by the actuator stack. This, in turn, varies the output frequency of the local sensor oscillator. The output, F(sub out), is fed to a phase detector, which is driven by a stable reference, F(sub ref). The output of the phase detector is a square waveform, D(sub out), whose duty cycle, t(sub W), varies in exact proportion according to whether F(sub out) is higher or lower than F(sub ref). In this design, should F(sub out) be precisely equal to F(sub ref), then the waveform has an exact 50/50 duty cycle. The waveform, D(sub out), is of generally very low frequency suitable for safe transmission over long distances without corruption. The active portion of the waveform, t(sub W), gates a remotely located counter, which is driven by a stable oscillator (source) of such frequency as to give sufficient digitization of t(sub W) to the resolution required by the application. The advantage to this scheme is that it negates the most-common, present method of sending either very low level signals (viz. direct output from the sensors) across great distances (anything over one-half meter) or the need to transmit widely varying higher frequencies over significant distances thereby eliminating interference [both in terms of beat frequency generation and in-situ EMI (electromagnetic interference)] caused by ineffective shielding. It also results in a significant reduction in shielding mass.

Strauss, Karl F.↗

Fault Location Using the Natural Frequency of Oscillation of Current Discharge in MTdc Networks

This paper discusses a novel offline-fault location approach using single ended measurements. The natural dissipation of the circuit parameters are considered for fault location. A relationship between the damped natural frequency of oscillation of the transmission line current and fault location is established. The hybrid dc circuit breaker (dcCB) interrupts the fault current, whereby the transmission line current attenuates under the absence of any driving voltage source. The line capacitance discharges into the fault at a specific frequency of oscillation and rate of attenuation. Utilizing this information, the fault location in a multi-terminal direct current (MTdc) network can be obtained. A three terminal radial model of a MTdc is used for performance evaluation of the proposed method using Power System Computer Aided Design (PSCAD)/Electromagnetic Transients including dc (EMTdc).

42 ENGINEERING↗

Measurements of three-flavor neutrino oscillations from a PISCES two-detector fit to the NOvA Experiment data

NOvA is a long-baseline neutrino oscillation experiment with two functionally identical detectors: a Near Detector (ND) at Fermilab, placed 1 km from the neutrino source, and a Far Detector (FD) located 810 km away from the ND in Minnesota. NOvA s primary physics goals are to measure the neutrino oscillation parameters $\theta_{23}$ and $\Delta m^2_{32}$ with high precision, determine the neutrino mass hierarchy, and constrain the value of $\delta_{CP}$, primarily via the study of muon neutrino to electron neutrino oscillation. Extracting values for oscillation parameters from fits to data usually relies on treating systematic uncertainties as nuisance parameters, a strategy that suffers from poor scalability as the number of uncertainties becomes larger. This work introduces PISCES (Parameter Inference with Systematic Covariance and Exact Statistics), a novel method that circumvents this scalability problem by encoding systematic uncertainties into a covariance matrix. PISCES utilizes a nested minimization in which optimal systematic pulls are first computed using the covariance matrix in an inner minimization step, then the oscillation parameters are profiled over in the outer minimization. PISCES also uses a Poisson Likelihood term, making it ideal for the inclusion of low-statistic samples in the fits. PISCES is a flexible framework that also supports complex fits, such as a joint Near and Far detector fit. In the standard NOvA analysis, oscillation parameters are extracted using an extrapolation technique in which the ND data indirectly constrain the FD prediction via a ratio method. PISCES, on the other hand, enables a simultaneous ND+FD fit, allowing the high-statistics ND data to directly constrain systematic uncertainties across all samples. This thesis presents the full PISCES joint ND+FD fit for the NOvA three-flavor analysis, details its implementation, and evaluates its performance through extensive robustness tests and fake data studies. It also provides a comparison between the PISCES joint ND+FD results and the standard NOvA extrapolation method using the full NOvA 10-year data set. The results demonstrate that PISCES can successfully fit NOvA data while incorporating the constraints from the ND detectors consistently, using physically motivated systematic uncertainties to account for data/MC discrepancies.

Rajaoalisoa, Miriama [Cincinnati U.]↗

PISCES two-detector covariance matrix fit for the NOvA Experiment

NOvA is a long-baseline neutrino oscillation experiment with two functionally identical detectors: a Near Detector (ND) at Fermilab, placed 1 km from the neutrino source, and a Far Detector (FD) located 810 km away from the ND in Minnesota. NOvA's primary physics goals are the precise measurements of neutrino oscillation parameters $\theta_{23}$ and $\Delta m^2_{32}$ , determine the neutrino mass ordering, and constrain the value of $\delta_{CP}$, via the study of muon neutrino to electron neutrino oscillation. In the standard NOvA three-flavor analysis, oscillation parameters are extracted using an extrapolation technique in which the ND data constrain the FD prediction through a ratio method. While this allows for systematic uncertainties sharing the same effects in both detectors to cancel, it remains an FD-only fit and does not fully leverage the constraining power of the high-statistics ND. This analysis proposes a simultaneous ND+FD fit using the PISCES method. PISCES (Parameter Inference with Systematic Covariance and Exact Statistics) is a framework designed to support complex configurations such as a joint ND+FD fit. This allows PISCES to take full advantage of the ND data to directly constrain systematic uncertainties across all samples. In PISCES, systematic uncertainties are encoded in a fractional covariance matrix, and statistical uncertainties are handled with a Poisson likelihood, making the approach well suited for low-statistics samples. For interpretability, we further use a Newton–Raphson + PCA method to recover per-systematic pulls from the covariance formulation. This poster presents the full PISCES joint ND+FD fit for the NOvA three-flavor analysis, describes its implementation and evaluates its performance through extensive robustness tests and fake data studies. It also provides a comparison between the PISCES joint ND+FD results and the standard NOvA extrapolation method.

Rajaoalisoa, Miriama [Cincinnati U.] (ORCID:000000↗

RF Device for Acquiring Images of the Human Body

A safe, non-invasive method for forming images through clothing of large groups of people, in order to search for concealed weapons either made of metal or not, has been developed. A millimeter wavelength scanner designed in a unique, ring-shaped configuration can obtain a full 360 image of the body with a resolution of less than a millimeter in only a few seconds. Millimeter waves readily penetrate normal clothing, but are highly reflected by the human body and concealed objects. Millimeter wave signals are nonionizing and are harmless to human tissues when used at low power levels. The imager (see figure) consists of a thin base that supports a small-diameter vertical post about 7 ft (=2.13 m) tall. Attached to the post is a square-shaped ring 2 in. (=5 cm) wide and 3 ft (=91 cm) on a side. The ring is oriented horizontally, and is supported halfway along one side by a connection to a linear bearing on the vertical post. A planar RF circuit board is mounted to the inside of each side of the ring. Each circuit board contains an array of 30 receivers, one transmitter, and digitization electronics. Each array element has a printed-circuit patch antenna coupled to a pair of mixers by a 90 coupler. The mixers receive a reference local oscillator signal to a subharmonic of the transmitter frequency. A single local oscillator line feeds all 30 receivers on the board. The resulting MHz IF signals are amplified and carried to the edge of the board where they are demodulated and digitized. The transmitted signal is derived from the local oscillator at a frequency offset determined by a crystal oscillator. One antenna centrally located on each side of the square ring provides the source illumination power. The total transmitted power is less than 100 mW, resulting in an exposure level that is completely safe to humans. The output signals from all four circuit boards are fed via serial connection to a data processing computer. The computer processes the approximately 1-MB data set into a three-dimensional image in a matter of seconds. The innovation is to configure the receiver array in a ring topology surrounding the scanned object. The ring is then scanned vertically to cover the necessary two-dimensional surface. This fabrication of the ring is made possible by using planar antenna and circuit technology. A planar circuit board serves as a medium for both antennas and signal processing components. Using this technique, parts counts are kept low, and the cost per element is a small fraction of a waveguide-based system.

Gaier, Todd C.↗

Muon Time-of-Flight studies for cosmic background rejection in the Short Baseline Near Detector

The Short-Baseline Neutrino (SBN) program at Fermilab is a cutting-edge project in experimental neutrino physics. One of its main goals is to systematically investigate the possible existence of eV-scale sterile neutrinos. This phenomenon has been hypothesized to explain some anomalies found in short-range experiments and, if confirmed, would imply a substantial extension of the Standard Model. SBN also offers an important opportunity to deepen the understanding of neutrino-nucleus interactions in the GeV energy range, through the use of Liquid Argon Time Projection Chambers (LArTPC) detectors, a fundamental technology also for the future DUNE experiment. The SBN experimental infrastructure consists of three detectors aligned along the Booster Neutrino Beamline at Fermilab. Among them, the detector located closest to the neutrino source, SBND (Short-Baseline Near Detector), positioned approximately 110 meters from the target, plays a key role in directly characterizing the initial neutrino flux. This allows for a direct comparison with the measurements from the far detector, ICARUS, located about 600 meters from the source, in order to search for potential signs of anomalous neutrino oscillations. My master's thesis focuses on the commissioning and characterization activities of the SBND detector, with particular reference to the Cosmic Ray Tagger (CRT). The CRT is a subsystem for identifying and rejecting events produced by cosmic rays, which constitute the main source of background for surface experiments like SBND. The activity began with the commissioning of the final components of the detector, as well as their validation to verify their correct functioning and signal acquisition. A central part of my work involved studying the veto efficiency of the CRT system, analyzing the rate of cosmic ray-induced events to quantify any loss of neutrino-induced events caused by cosmic background. This allowed for a more precise evaluation of the systematic impact of the CRT on the useful physics sample. A further phase of my analysis involved an in-depth study of the temporal correlation between the CRT signals and those acquired by the LArTPC's internal photodetector system, consisting of photomultiplier tubes and X-ARAPUCA devices. The objective is to explore the possibility of using combined temporal information as an additional criterion for discriminating between cosmic signals and signals genuinely due to neutrino interaction. Preliminary results indicate the presence of characteristic temporal signatures that could be exploited to improve event selection and increase the purity of the neutrino-induced sample. These methodologies will certainly contribute to the optimization of SBND analysis strategies and, more generally, to a better understanding of background mechanisms in next-generation LArTPC experiments.

Corallo, Annalea [Ferrara U.]↗

Latest Three-Flavor Neutrino Oscillation Results from NOvA

NOvA, is a two-detector, long-baseline neutrino oscillation experiment located at Fermilab, Batavia, IL, USA. It aims to constrain neutrino oscillation parameters by analyzing $\nu_\mu (\bar{\nu}_\mu)$ disappearance and $\nu_e (\bar{\nu}_e)$ appearance data. The experiment uses the Neutrinos at Main Injector (NuMI) beamline at Fermilab, which delivers a high-purity 900 KW beam of neutrinos and anti-neutrinos. The detectors are functionally identical finely granulated liquid tracking calorimeters, both situated 14.6 mrad off-axis to the beam direction. The NOvA Near Detector (ND), situated 100 meters underground and 1 kilometer from the beam source, detects the un-oscillated $\nu_\mu (\bar{\nu}_\mu)$ and beam $\nu_e (\bar{\nu}_e)$ events. The Far Detector (FD), located in Ash River, MN, USA, 809 kilometers from the ND, records the oscillated $\nu_e (\bar{\nu}_e)$ and the un-oscillated $\nu_\mu (\bar{\nu}_\mu)$ events. NOvA employs an extrapolation technique to predict the expected events at the Far Detector based on the Near Detector data, thereby providing a significant constraint on systematic uncertainties in the oscillation analyses. As NOvA accumulates more data, controlling these systematic uncertainties becomes increasingly important. This talk will detail the NOvA neutrino oscillation analysis framework and its approach to minimizing dominant systematic uncertainties using Near Detector data. The latest three flavor neutrino oscillation results based on a neutrino-beam exposure of $26.60 \times 10^{20}$ POT and an anti-neutrino beam exposure of $12.50\times 10^{20}$ POT and a novel low energy $\nu_e$ sample, will also be presented.

Choudhary, Brajesh↗

New NOvA Results with 10 Years of Data

NOvA is a two-detector accelerator neutrino oscillation experiment. Using Fermilab's newly Megawatt-capable NuMI neutrino beam, NOvA measures the disappearance of muon (anti)neutrinos and the appearance of electron (anti)neutrinos at the far detector, 810 km from the source. These oscillations are observed relative to the unoscillated beam composition measured at the functionally equivalent near detector, also located at Fermilab, which enables significant cancellation of systematic uncertainties. From these, we obtain precision measurements of the larger neutrino mass splitting and the largest neutrino mixing angle, as well as constraints on the octant of that angle, the neutrino mass ordering, and neutrino CP violation. In this talk I will present new measurements of these parameters using 10 years of NOvA data collected between 2013 and 2023, which includes twice the neutrino-mode exposure of our previous results.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Neutrino Oscillations at the NOvA Experiment

NOvA is a long-baseline neutrino oscillation experiment located at Fermi National Accelerator Laboratory (Fermilab) in Batavia, IL, USA. Its main goal is to extract neutrino oscillation parameters by examining the disappearance of $\nu_\mu \ (\bar{\nu}_\mu)$ and the appearance of $\nu_e \ (\bar{\nu}_e)$ at its far detector. The experiment uses the NuMI beamline at Fermilab, which delivers a high-purity neutrino and antineutrino beam. NOvA consists of two functionally similar, high-resolution liquid scintillator tracking calorimeters, both placed 14.6 milliradians off the beam axis. The near detector, positioned 100 m underground and 1 km from the beam's origin, captures unoscillated $\nu_\mu (\bar{\nu}_\mu)$ and instrinsic beam $\nu_e \ (\bar{\nu}_e)$ events. The far detector, located 810 km away from the beam source in Ash River, Minnesota, measures both unoscillated $\nu_\mu \ (\bar{\nu}_\mu)$ and those that have oscillated into $\nu_\mu \ (\bar{\nu}_\mu) \to \nu_e \ (\bar{\nu}_e)$. This poster will cover the latest results on three-flavor neutrino oscillation parameters, derived from an exposure of neutrino beam of $26.60 \times 10^{20}$ POT and anti-neutrino beam exposure of $12.50\times 10^{20}$ POT including an additional low energy $\nu_e$ sample.

Singh, Ishwar [Delhi U.]↗

Inference of bipolar neutrino flavor oscillations near a core-collapse supernova based on multiple measurements at Earth

Neutrinos in compact-object environments, such as core-collapse supernovae, can experience various kinds of collective effects in flavor space, engendered by neutrino-neutrino interactions. These include “bipolar” collective oscillations, which are exhibited by neutrino ensembles where different flavors dominate at different energies. Considering the importance of neutrinos in the dynamics and nucleosynthesis in these environments, it is desirable to ascertain whether an Earth-based detection could contain signatures of bipolar oscillations that occurred within a supernova envelope. To that end, we, in this study, continue examining a cost-function formulation of statistical data assimilation (SDA) to infer solutions to a small-scale model of neutrino flavor transformation. SDA is an inference paradigm designed to optimize a model with sparse data. Our model consists of two monoenergetic neutrino beams with different energies emanating from a source and coherently interacting with each other and with a matter background, with radially varying interaction strengths. We attempt to infer flavor transformation histories of these beams using simulated measurements of the flavor content at locations “in vacuum” (that is, far from the source), which could in principle correspond to Earth-based detectors. Within the scope of this small-scale model, we found that: (i) based on such measurements, the SDA procedure is able to infer whether bipolar oscillations had occurred within the protoneutron star envelope, and (ii) if the measurements sample the full amplitude of the neutrino oscillations in vacuum, then the amplitude of the prior bipolar oscillations is well predicted. This result intimates that the inference paradigm can well complement numerical integration codes, via its ability to infer flavor evolution at physically inaccessible locations.

79 ASTRONOMY AND ASTROPHYSICS↗

Physics of Neutrino Oscillations and Neutrino Cross Sections using the NOvA Experiment

NOvA is a long-baseline accelerator-based neutrino experiment based in the US. NOvA uses an intense neutrino beam produced at Fermilab’s accelerator complex to make physics measurements of neutrino oscillations, neutrino cross sections, and much more. For its physics goals, NOvA uses two functionally-identical detectors. The Near Detector (ND) is situated at Fermilab, 1 km from the neutrino target and the Far Detector (FD) is located at Ash River, MN, a distance of 810 km from the neutrino source. The ND receives a high statistics neutrino flux which gives a unique opportunity for high-precision neutrino cross-section measurements and is used as a control for the oscillation analyses. The FD is used to analyze the appearance and disappearance of the neutrinos arriving from the Fermilab. The purpose of the oscillation analysis is to understand the dominance of matter over antimatter in the universe, to resolve the ordering of neutrino masses, and to resolve the octant of the neutrino mixing angle theta23. In this talk, I will give an overview of the NOvA experiment. I will also talk about the status of the NOvA’s cross-section physics program and the latest results from the oscillation analyses. I will also talk about the future prospects of the experiment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Neutrino Scattering in the NOvA Near Detector

aNOvA is a long-baseline accelerator-based neutrino experiment based in the USA. NOvA uses an intense neutrino beam produced at Fermilab’s accelerator complex to make physics measurements of neutrino oscillations, neutrino cross sections, and much more. For its physics goals, NOvA uses two functionally-identical detectors. The Near Detector (ND) is situated at Fermilab, 1 km from the neutrino target and the Far Detector (FD) is located at Ash River, MN, a distance of 810 km from the neutrino source. The ND receives a high statistics neutrino flux which gives a unique opportunity for high-precision neutrino cross-section measurements and is used as a control for the oscillation analyses. In this talk/poster, I will give an overview of the NOvA experiment. I will also talk about the current and future status of the NOvA’s cross-section physics program.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The DUNE Experiment

The Deep Underground Neutrino Experiment (DUNE) is a next generation long-baseline neutrino experiment built to answer some of the most fundamental questions in the universe. DUNE will consist of two neutrino detectors placed in the world’s most intense neutrino beam facility named as Long-Baseline Neutrino Facility (LBNF). It consists of a near detector and a far detector that is comprised initially of two modules and eventually of four modules, each of fiducial mass 17.5 ktons of liquid Argon. The far detector is located 1300 km from the beam source placed underground at the Sanford Underground Research Laboratory in Lead, South Dakota. DUNE will measure the un-oscillated neutrinos nucleus interactions at near detector and oscillated interactions at far detector which will be able to address the questions about the preponderance of matter over antimatter in the early universe, searches for leptonic charge-parity symmetry violation, proton decay, supernova neutrino bursts and unification of forces. This article discussed the goals and physics of the DUNE experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Materials Combustion Testing and Combustion Product Sensor Evaluations in FY12

NASA Centers continue to collaborate to characterize the chemical species and smoke particles generated by the combustion of current space-rated non-metallic materials including fluoropolymers. This paper describes the results of tests conducted February through September 2012 to identify optimal chemical markers both for augmenting particle-based fire detection methods and for monitoring the post-fire cleanup phase in human spacecraft. These studies follow up on testing conducted in August 2010 and reported at ICES 2011. The tests were conducted at the NASA White Sands Test Facility in a custom glove box designed for burning fractional gram quantities of materials under varying heating profiles. The 623 L chamber was heavily instrumented to quantify organics (gas chromatography/mass spectrometry), inorganics by water extraction followed by ion chromatography, and select species by various individual commercially-available sensors. Evaluating new technologies for measuring carbon monoxide, hydrogen cyanide, hydrogen fluoride, hydrogen chloride and other species of interest was a key objective of the test. Some of these sensors were located inside the glovebox near the fire source to avoid losses through the sampling lines; the rest were located just outside the glovebox. Instruments for smoke particle characterization included a Tapered Element Oscillating Microbalance Personal Dust Monitor (TEOM PDM) and a TSI Dust Trak DRX to measure particle mass concentration, a TSI PTrak for number concentration and a thermal precipitator for collection of particles for microscopic analysis. Materials studied included Nomex®, M22759 wire insulation, granulated circuit board, polyvinyl chloride (PVC), Polytetrafluoroethylene (PTFE), Kapton®, and mixtures of PTFE and Kapton®. Furnace temperatures ranged from 340o to 640o C, focusing on the smoldering regime. Of particular interest in these tests was confirming burn repeatability and production of acid gases with different fuel mixture compositions, as well as the dependence of aerosol concentrations on temperature.

Smoke↗