Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “optimized Schwarz method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

32 records · Page 2

Sample preparation methods for scanning electron microscopy of homogenized Al-Mg-Si billets: A comparative study

Characterization of Mg-Si precipitates is crucial for optimizing the homogenization heat treatment of Al-Mg-Si alloys. Although sample preparation is key for high quality scanning electron microscopy imaging, most common methods lead to dealloying of Mg-Si precipitates. In this article we systematically evaluate different sample preparation methods: mechanical polishing, etching with various reagents, and electropolishing using different electrolytes. We demonstrate that the use of a nitric acid and methanol electrolyte for electropolishing a homogenized Al-Mg-Si alloy prevents the dissolution of Mg-Si precipitates, resulting in micrographs of higher quality. This preparation method is investigated in depth and the obtained scanning electron microscopy images are compared with transmission electron micrographs: the shape and size of Mg-Si precipitates appear very similar in either method. The scanning electron micrographs allow proper identification and measurement of the Mg-Si phases including needles with lengths of roughly 200 nm. These needles are β″ precipitates as confirmed by high resolution transmission electron microscopy. - Highlights: •Secondary precipitation in homogenized 6xxx Al alloys is crucial for extrudability. •Existing sample preparation methods for SEM are improvable. •Electropolishing with nitric acid/methanol yields superior quality in SEM. •The obtained micrographs are compared to TEM micrographs.

36 MATERIALS SCIENCE↗

Optimal Methods for Estimating Cactus Pear Biomass Using Cladode Dimensions of Morphologically Diverse Accessions

Current allometric methods for photosynthetic-stem (cladode) plants, such as cactus pear (Opuntia spp.), require refinement to be used in field settings in which diverse accessions are grown. We analysed cladode dimensional data using 14 accessions representing four species and two hybrids to quantify statistically significant morphological differences among accessions and derived cross-accession models to approximate cladode fresh weight. A Box model using cladode dimensions (e.g., length, width, thickness and diameter) and factorial combinations of these measures (e.g., length*width*thickness*diameter vs. fresh weight) resulted in the highest coefficient of determination (R 2 = 0.95 general fit) across all accessions for estimating fresh weight along with parsimony estimates using the Schwarz–Bayes Criterion (SBC), which assesses the most consistent performance on individual accessions. A Fitting-box modelling approach used the measured cladode area captured using ImageJ (R 2 = 0.93 general fit). Lastly, an Elliptical model used an elliptical approximation for the measured area and performed well over all accessions (R 2 = 0.94 general fit) while avoiding extensive manual measurements. These models meet or exceed the performance of previously published approaches when applied across morphologically diverse accessions, providing efficient tools for nondestructive estimation of cactus pear biomass under the conditions tested.

Opuntia↗

Ultrashort pulse laser-triggering of long gap high voltage switches

Laser-triggered high voltage switches need longer length and lifetime laser plasmas at controlled plasma densities in order to achieve optimal operational parameters (such as short runtime, low temporal jitter, and high voltage hold-off). We have approached the problem by considering ultrashort laser pulses of sub-picosecond duration for the high voltage trigger source. To this end, several laser plasma diagnostic techniques were employed to quantify the ionization and to determine methods for appropriately tailoring the laser plasma for switch ing purposes. Switching behavior under basic plasma conditions and with improved plasma channels are discussed.

Rambo, Patrick K.↗

On the Convergence of Overlapping Schwarz Decomposition for Nonlinear Optimal Control

Here, we study the convergence properties of an overlapping Schwarz decomposition algorithm for solving nonlinear optimal control problems (OCPs). The algorithm decomposes the time domain into a set of overlapping subdomains, and solves all subproblems defined over subdomains in parallel. The convergence is attained by updating primal-dual information at the boundaries of overlapping subdomains. We show that the algorithm exhibits local linear convergence, and that the convergence rate improves exponentially with the overlap size. We also establish global convergence results for a general quadratic programming, which enables the application of the Schwarz scheme inside second-order optimization algorithms (e.g., sequential quadratic programming). The theoretical foundation of our convergence analysis is a sensitivity result of nonlinear OCPs, which we call "exponential decay of sensitivity" (EDS). Intuitively, EDS states that the impact of perturbations at domain boundaries (i.e., initial and terminal time) on the solution decays exponentially as one moves into the domain. Here, we expand a previous analysis available in the literature by showing that EDS holds for both primal and dual solutions of nonlinear OCPs, under uniform second-order sufficient condition, controllability condition, and boundedness condition. We conduct experiments with a quadrotor motion planning problem and a partial differential equations (PDE) control problem to validate our theory, and show that the approach is significantly more efficient than alternating direction method of multipliers and as efficient as the centralized interior-point solver.

42 ENGINEERING↗

Two-level overlapping additive Schwarz preconditioner for training scientific machine learning applications

In this work we introduce a novel two-level overlapping additive Schwarz preconditioner for accelerating the training of scientific machine learning applications. The design of the proposed preconditioner is motivated by the nonlinear two-level overlapping additive Schwarz preconditioner. The neural network parameters are decomposed into groups (subdomains) with overlapping regions. In addition, the network’s feed-forward structure is indirectly imposed through a novel subdomain-wise synchronization strategy and a coarse-level training step. Through a series of numerical experiments, which consider physicsinformed neural networks and operator learning approaches, we demonstrate that the proposed two-level preconditioner significantly speeds up the convergence of the standard (LBFGS) optimizer while also yielding more accurate machine learning models. Moreover, the devised preconditioner is designed to take advantage of model-parallel computations, which can further reduce the training time.

97 MATHEMATICS AND COMPUTING↗

Proton reconstruction with the TOTEM Roman pot detectors for high- β * LHC data

The TOTEM Roman pot detectors are used to reconstruct the transverse momentum of scattered protons and to estimate the transverse location of the primary interaction. This paper presents new methods of track reconstruction, measurements of strip-level detection efficiencies, cross-checks of the LHC beam optics, and detector alignment techniques, along with their application in the selection of signal collision events. The track reconstruction is performed by exploiting hit cluster information through a novel method using a common polygonal area in the intercept-slope plane. The technique is applied in the relative alignment of detector layers with μm precision. A tag-and-probe method is used to extract strip-level detection efficiencies. The alignment of the Roman pot system is performed through time-dependent adjustments, resulting in a position accuracy of 3 μm in the horizontal and 60 μm in the vertical directions. The goal is to provide an optimal reconstruction tool for central exclusive physics analyses based on the high-β* data-taking period at $\sqrt({s})$ = 13 TeV in 2018.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Machine learning method for enforcing variable independence in background estimation with LHC data: ABCDisCoTEC

A novel solution is presented for the problem of estimating the backgrounds of a signal search using observed data while simultaneously maximizing the sensitivity of the search to the signal. The 'ABCD method' provides a reliable framework for background estimation by partitioning events into one signal-enhanced region (A) and three background-enhanced control regions (B, C, and D) via two smoothly varying, statistically independent variables. In practice, even slight correlations between the two variables can significantly undermine the method's performance. Thus, choosing appropriate variables by hand can present a formidable challenge, especially when background and signal differ only subtly. To address this issue, the ABCD with distance correlation (ABCDisCo) method was developed to construct two learned variables via a neural network trained to provide strong signal-background discrimination with small values of the distance correlation (DisCo) measure between the two learned variables. However, relying solely on minimizing the DisCo can result in learned variables that may not have distributions of background events that are smoothly varying and localized at extreme values, as necessary for the validity of the background estimation. The ABCDisCo training enhanced with closure (ABCDisCoTEC) method is introduced to solve this issue by directly minimizing the nonclosure, expressed as a dedicated differentiable loss term. This extended method is applied to a data set of proton-proton collisions at a center-of-mass energy of 13 TeV recorded by the CMS detector at the CERN Large Hadron Collider. Additionally, given the complexity of the minimization problem with constraints on multiple loss terms, the modified differential method of multipliers is applied and shown to greatly improve the stability and robustness of the ABCDisCoTEC method, compared to grid search hyperparameter optimization procedures.

Hayrapetyan, Aram [Yerevan Phys. Inst.]↗

Optimizing qPlus sensor assemblies for simultaneous scanning tunneling and noncontact atomic force microscopy operation based on finite element method analysis

Quartz tuning forks that have a probe tip attached to the end of one of its prongs while the other prong is arrested to a holder (“qPlus” configuration) have gained considerable popularity in recent years for high-resolution atomic force microscopy imaging. The small size of the tuning forks and the complexity of the sensor architecture, however, often impede predictions on how variations in the execution of the individual assembly steps affect the performance of the completed sensor. Extending an earlier study that provided numerical analysis of qPlus-style setups without tips, this work quantifies the influence of tip attachment on the operational characteristics of the sensor. The results using finite element modeling show in particular that for setups that include a metallic tip that is connected via a separate wire to enable the simultaneous collection of local forces and tunneling currents, the exact realization of this wire connection has a major effect on sensor properties such as spring constant, quality factor, resonance frequency, and its deviation from an ideal vertical oscillation.

42 ENGINEERING↗

Comparison of proton therapy treatment planning for head tumors with a pencil beam algorithm on dual and single energy CT images

Purpose: Dual energy CT (DECT) has recently been proposed as an improvement over single energy CT (SECT) for stopping power ratio (SPR) estimation for proton therapy treatment planning (TP), thereby potentially reducing range uncertainties. Published literature investigated phantoms. This study aims at performing proton therapy TP on SECT and DECT head images of the same patients and at evaluating whether the reported improved DECT SPR accuracy translates into clinically relevant range shifts in clinical head treatment scenarios. Methods: Two phantoms were scanned at a last generation dual source DECT scanner at 90 and 150 kVp with Sn filtration. The first phantom (Gammex phantom) was used to calibrate the scanner in terms of SPR while the second served as evaluation (CIRS phantom). DECT images of five head trauma patients were used as surrogate cancer patient images for TP of proton therapy. Pencil beam algorithm based TP was performed on SECT and DECT images and the dose distributions corresponding to the optimized proton plans were calculated using a Monte Carlo (MC) simulation platform using the same patient geometry for both plans obtained from conversion of the 150 kVp images. Range shifts between the MC dose distributions from SECT and DECT plans were assessed using 2D range maps. Results: SPR root mean square errors (RMSEs) for the inserts of the Gammex phantom were 1.9%, 1.8%, and 1.2% for SECT phantom calibration (SECT{sub phantom}), SECT stoichiometric calibration (SECT{sub stoichiometric}), and DECT calibration, respectively. For the CIRS phantom, these were 3.6%, 1.6%, and 1.0%. When investigating patient anatomy, group median range differences of up to −1.4% were observed for head cases when comparing SECT{sub stoichiometric} with DECT. For this calibration the 25th and 75th percentiles varied from −2% to 0% across the five patients. The group median was found to be limited to 0.5% when using SECT{sub phantom} and the 25th and 75th percentiles varied from −1% to 2%. Conclusions: Proton therapy TP using a pencil beam algorithm and DECT images was performed for the first time. Given that the DECT accuracy as evaluated by two phantoms was 1.2% and 1.0% RMSE, it is questionable whether the range differences reported here are significant.

61 RADIATION PROTECTION AND DOSIMETRY↗

{sup 18}-F-Fluorodeoxyglucose-Positron Emission Tomography Evaluation of Early Metabolic Response During Radiation Therapy for Cervical Cancer

Purpose: To document changes in cervical tumor {sup 18}-F-fluorodeoxyglocose (FDG) uptake during radiation therapy and to correlate those changes with post-treatment tumor response and survival outcome. Methods and Materials: A total of 36 patients with Stage Ib1 to IIIb cervical cancer were enrolled in an institutional protocol examining the use of fluorodeoxyglucose-positron emission tomography (FDG-PET) for brachytherapy treatment planning. As part of this study, FDG-PET or PET/computed tomograpy (CT) images were obtained before, during, and after the completion of radiation therapy. Tumor metabolic responses were assessed qualitatively and semi-quantitatively by measurement of the maximal standardized uptake value (SUV{sub max}). Results: Post-treatment FDG-PET images were obtained for 36 patients in this study. Of the patients, 29 patients had a complete metabolic response on the post-treatment PET, 4 had a partial metabolic response, and 3 had new sites of FDG uptake. Six patients had a complete metabolic response observed during radiation therapy, 26 had a partial metabolic response and 4 had stable or increased tumor metabolic activity. For patients with complete metabolic response during radiation therapy, median time to complete response was 29.5 days (range, 18-43 days). The mean cervical tumor SUV{sub max} decreased from 11.2 (SD, 6.3; range, 2.1-38.0) pretreatment to 2.4 (SD, 2.7; range, 0-8.8) mid treatment, and 0.5 (SD, 1.7; range, 0-8.3) post-treatment. Conclusions: During radiation therapy for cervical cancer, FDG-PET can be used to monitor treatment response. Complete metabolic response during radiation therapy was observed for a subset of patients. Recommendations regarding the optimal timing of FDG-PET during treatment for cervical cancer will require further systematic study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Helical Tomotherapy vs. Intensity-Modulated Proton Therapy for Whole Pelvis Irradiation in High-Risk Prostate Cancer Patients: Dosimetric, Normal Tissue Complication Probability, and Generalized Equivalent Uniform Dose Analysis

Purpose: To compare intensity-modulated proton therapy (IMPT) and helical tomotherapy (HT) treatment plans for high-risk prostate cancer (HRPCa) patients. Methods and Materials: The plans of 8 patients with HRPCa treated with HT were compared with IMPT plans with two quasilateral fields set up (-100{sup o}; 100{sup o}) and optimized with the Hyperion treatment planning system. Both techniques were optimized to simultaneously deliver 74.2 Gy/Gy relative biologic effectiveness (RBE) in 28 fractions on planning target volumes (PTVs)3-4 (P + proximal seminal vesicles), 65.5 Gy/Gy(RBE) on PTV2 (distal seminal vesicles and rectum/prostate overlapping), and 51.8 Gy/Gy(RBE) to PTV1 (pelvic lymph nodes). Normal tissue calculation probability (NTCP) calculations were performed for the rectum, and generalized equivalent uniform dose (gEUD) was estimated for the bowel cavity, penile bulb and bladder. Results: A slightly better PTV coverage and homogeneity of target dose distribution with IMPT was found: the percentage of PTV volume receiving {>=}95% of the prescribed dose (V{sub 95%}) was on average >97% in HT and >99% in IMPT. The conformity indexes were significantly lower for protons than for photons, and there was a statistically significant reduction of the IMPT dosimetric parameters, up to 50 Gy/Gy(RBE) for the rectum and bowel and 60 Gy/Gy(RBE) for the bladder. The NTCP values for the rectum were higher in HT for all the sets of parameters, but the gain was small and in only a few cases statistically significant. Conclusions: Comparable PTV coverage was observed. Based on NTCP calculation, IMPT is expected to allow a small reduction in rectal toxicity, and a significant dosimetric gain with IMPT, both in medium-dose and in low-dose range in all OARs, was observed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Intensity-Modulated Proton Therapy Versus Helical Tomotherapy in Nasopharynx Cancer: Planning Comparison and NTCP Evaluation

Purpose: To compare intensity-modulated proton therapy (IMPT) and helical tomotherapy (HT) treatment plans for nasopharynx cancer using a simultaneous integrated boost approach. Methods and Materials: The data from 6 patients who had previously been treated with HT were used. A three-beam IMPT technique was optimized in the Hyperion treatment planning system, simulating a 'beam scanning' technique. HT was planned using the tomotherapy treatment planning system. Both techniques were optimized to simultaneously deliver 66 Gy in 30 fractions to planning target volume (PTV1; GTV and enlarged nodes) and 54 Gy to PTV2 subclinical, electively treated nodes. Normal tissue complication probability calculation was performed for the parotids and larynx. Results: Very similar PTVs coverage and homogeneity of the target dose distribution for IMPT and HT were found. The conformity index was significantly lower for protons than for photons (1.19 vs. 1.42, respectively). The mean dose to the ipsilateral and contralateral parotid glands decreased by 6.4 Gy and 5.6 Gy, respectively, with IMPT. The volume of mucosa and esophagus receiving {>=}20 Gy and {>=}30 Gy with IMPT was significantly lower than with HT. The average volume of larynx receiving {>=}50 Gy was significantly lower with HT, while for thyroid, it was comparable. The volume receiving {>=}30, {>=}20, and {>=}10 Gy in total body volume decreased with IMPT by 14.5%, 19.4%, and 23.1%, respectively. The normal tissue complication probability for the parotid glands was significantly lower with IMPT for all sets of parameters; however, we also estimated an almost full recovery of the contralateral parotid with HT. The normal tissue complication probability for the larynx was not significantly different between the two irradiation techniques. Conclusion: Excellent target coverage, homogeneity within the PTVs, and sparing of the organs at risk were reached with both modalities. IMPT allows for better sparing of most organs at risk at medium-to-low doses.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Is there a single spot size and grid for intensity modulated proton therapy? Simulation of head and neck, prostate and mesothelioma cases

Purpose: To assess the quality of dose distributions in real clinical cases for different dimensions of scanned proton pencil beams. The distance between spots (i.e., the grid of delivery) is optimized for each dimension of the pencil beam. Methods: The authors vary the {sigma} of the initial Gaussian size of the spot, from {sigma}{sub x} = {sigma}{sub y} = 3 mm to {sigma}{sub x} = {sigma}{sub y} = 8 mm, to evaluate the impact of the proton beam size on the quality of intensity modulated proton therapy (IMPT) plans. The distance between spots, {Delta}x and {Delta}y, is optimized on the spot plane, ranging from 4 to 12 mm (i.e., each spot size is coupled with the best spot grid resolution). In our Hyperion treatment planning system (TPS), constrained optimization is applied with respect to the organs at risk (OARs), i.e., the optimization tries to satisfy the dose objectives in the planning target volume (PTV) as long as all planning objectives for the OARs are met. Three-field plans for a nasopharynx case, two-field plans for a prostate case, and two-field plans for a malignant pleural mesothelioma case are considered in our analysis. Results: For the head and neck tumor, the best grids (i.e., distance between spots) are 5, 4, 6, 6, and 8 mm for {sigma} = 3, 4, 5, 6, and 8 mm, respectively. {sigma} {<=} 5 mm is required for tumor volumes with low dose and {sigma}{<=} 4 mm for tumor volumes with high dose. For the prostate patient, the best grid is 4, 4, 5, 5, and 5 mm for {sigma} = 3, 4, 5, 6, and 8 mm, respectively. Beams with {sigma} > 3 mm did not satisfy our first clinical requirement that 95% of the prescribed dose is delivered to more than 95% of prostate and proximal seminal vesicles PTV. Our second clinical requirement, to cover the distal seminal vesicles PTV, is satisfied for beams as wide as {sigma} = 6 mm. For the mesothelioma case, the low dose PTV prescription is well respected for all values of {sigma}, while there is loss of high dose PTV coverage for {sigma} > 5 mm. The best grids have a spacing of 6, 7, 8, 9, and 12 mm for {sigma} = 3, 4, 5, 6, and 8 mm, respectively. Conclusions: The maximum acceptable proton pencil beam {sigma} depends on the volume treated, the protocol of delivery, and optimization of the plan. For the clinical cases, protocol and optimization used in this analysis, acceptable {sigma}s are {<=} 4 mm for the head and neck tumor, {<=} 3 mm for the prostate tumor and {<=} 6 mm for the malignant pleural mesothelioma. One can apply the same procedure used in this analysis when given a ''class'' of patients, a {sigma} and a clinical protocol to determine the optimal grid spacing.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Atomic-Scale Surface Studies of Bulk Metallic Glasses. Final Report

Bulk metallic glasses (BMGs) are of both scientific and technological interest because the absence of periodic atomic arrangements provides them with unique physical, chemical, and mechanical properties. Their high strength, superior elasticity, and an ability to be easily formed into virtually unlimited shapes with feature sizes from centimeters to Angstroms by blow molding and thermoplastic forming makes them an attractive choice for more and more practical applications and products. Due to their complex internal structure, however, experiments that yield insight into their exact atomic arrangements have been scarce. As a result, glass physics is one of the last remaining unexplored fields of materials science despite the scientific and technological importance of glasses in our daily lives, and the question how to characterize and control matter away from equilibrium, as glasses are, was listed as one of five Grand Challenges in a recent DoE report. The main reason for the slow progress in glass physics is the lack of experimental tools that enable access to atomic-scale structural and behavioral information for disordered materials. Such atomic-scale knowledge is mandatory to establish structure-property relationships that ultimately could allow to custom-design alloys featuring specific desired characteristics. With no such relationships available, theory development in glass remains basic and the few that exist are often untested. The aim of this research was to enable progress in our understanding of BMGs by developing a new approach that will allow a meaningful application of local surface science methods to specially prepared BMG samples to obtain a wealth of quantitative information on their atomic arrangements. Key was the availability of specially prepared samples whose surfaces feature large atomically flat terraces despite being entirely amorphous, which we have produced from a Pt 57.5 Cu 14.7 Ni 5.3 P 22.5 alloy (‘Pt-BMG’) both under ambient conditions as well as in ultrahigh vacuum using a unique setup that has been specially developed within this grant. Our approach starts with the in-situ preparation of oxide crystals that are terminated by large terraces, from which exact mirror images out of BMG will be produced using thermoplastic forming (TPF); for the research within this grant, we have successfully used (001)-oriented SrTiO 3 single crystal surfaces as well as (100)-, (110)-, and (111)-oriented single crystals made from LaAlO 3 . Since the resulting BMG replicas display all features of the original crystal with sub-Angstrom fidelity, thereby mimicking the original crystal’s termination by atomically flat terraces without being crystalline themselves, they are ideally suited for further investigation. The following atomic-scale local studies were then carried within this proposal: (i) high-resolution surface imaging and local spectroscopy using scanning probe microscopy, which showed disordered atom-like features and revealed changes in the gradient of the local surface potential on a 1-2 nm length scale; (ii) characterization of atomic-scale plastic flow with affected volumes as low as 1000 atoms, which showed local hardness near or above the theoretically predicted maximum and, once plastic deformation was initiated, homogeneous flow of the atoms involved; (iii) characterization of surface relaxation processes and the onset of crystallization induced by annealing, which showed that upon heating over the material’s glass transition temperature, the surface rearranges and relaxes towards a more stable, denser packed glass, which increases on-terrace surface roughness, while surface tension smoothens step edges; and (iv) studies that investigate the dependence of the material’s mechanical properties and structure on processing parameters, revealing that relaxed glasses get denser, harder, and more elastic. In combination, this information allows to combine structural models with mechanical properties and preparation history, thereby facilitating the development of preparation-structure-property relationships for metallic glasses. With the availability of such information, bulk metallic glasses can be further optimized to be used in more and more applications in industry.

36 MATERIALS SCIENCE↗