Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “optimal filter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

New limit on dark photon kinetic mixing in the 0.2 – 1.2 μ eV mass range from the Dark E-field Radio experiment

We report new limits on the kinetic mixing strength of the dark photon spanning the mass range 0.21 − 1.24 μ eV corresponding to a frequency span of 50–300 MHz. The Dark E-field Radio experiment is a wideband search for dark photon dark matter. In this paper we detail changes in calibration and upgrades since our proof-of-concept pilot run. Our detector employs a wide-bandwidth E-field antenna moved to multiple positions in a shielded room, a low noise amplifier, wideband analog-to-digital converter, followed by a 2 24 -point fast Fourier transform. An optimal filter searches for signals with Q ≈ 10 6 . In nine days of integration, this system is capable of detecting dark photon signals corresponding to a kinetic mixing strength ε several orders of magnitude lower than previous limits. We find a 95% exclusion limit on ε over this mass range between 6 × 10 − 15 and 6 × 10 − 13 , tracking the complex resonant mode structure in the shielded room. Published by the American Physical Society 2024

Astronomy & Astrophysics↗

Improving the performance of cryogenic calorimeters with nonlinear multivariate noise cancellation algorithms

Abstract State-of-the-art physics experiments require high-resolution, low-noise, and low-threshold detectors to achieve competitive scientific results. However, experimental environments invariably introduce sources of noise, such as electrical interference or microphonics. The sources of this environmental noise can often be monitored by adding specially designed “auxiliary devices” (e.g. microphones, accelerometers, seismometers, magnetometers, and antennae). A model can then be constructed to predict the detector noise based on the auxiliary device information, which can then be subtracted from the true detector signal. Here, we present a multivariate noise cancellation algorithm which can be used in a variety of settings to improve the performance of detectors using multiple auxiliary devices. To validate this approach, we apply it to simulated data to remove noise due to electromagnetic interference and microphonic vibrations. We then employ the algorithm to a cryogenic light detector in the laboratory and show an improvement in the detector performance. Finally, we motivate the use of nonlinear terms to better model vibrational contributions to the noise in thermal detectors. We show a further improvement in the performance of a particular channel of the CUORE detector when using the nonlinear algorithm in combination with optimal filtering techniques.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Assessment of Low-Level Pu Isotope Ratio Measurements Using Multicollector Inductively Coupled Plasma Mass Spectrometry (MC-ICP-MS/MS) Equipped with a Pre-Mass Filter

We present an initial investigation into the performance of a multicollector inductively coupled plasmamass spectrometer equipped with a pre-mass filter (Neoma MC-ICP-MS/MS) for making plutonium (Pu) isotope ratio measurements on solutions containing low level (i.e., pg mL –1 ) Pu concentrations. This assessment was achieved by comparison of the 240 Pu/ 239 Pu, 241 Pu/ 239 Pu, and 242 Pu/ 239 Pu ratios attained over a one month period on the MC-ICP-MS/MS with the long-term (∼1 year) performance observed on the predecessor MC-ICP-MS (Neptune Plus) instrument each equipped with an equipped with an APEXΩ desolvating nebulizer for repeated measurements of certified reference materials from New Brunswick Program Office (NBL PO) CRM 136a and CRM 137. The MC-ICP-MS/MS performance of repeated measurement of CRM 136a (n = 20) resulted in mean values of 240 Pu/ 239 Pu = 0.1448 ± 0.0006, 241 Pu/ 239 Pu = 0.00371 ± 0.00006, and 242 Pu/ 239 Pu = 0.00682 ± 0.00006 (k = 2). The CRM 137 (n = 20), analyzed during the same analytical sessions, produced mean values for 240 Pu/ 239 Pu = 0.2414 ± 0.0006, 241 Pu/ 239 Pu = 0.00464 ± 0.00007, and 242 Pu/ 239 Pu = 0.0157 ± 0.0001 (k = 2). These results closely align with the certificate values for CRM 136a and CRM 137 and are within the k = 2 envelopes defined by the long-term performance of the traditional MC-ICP-MS approach (Neptune Plus). Examination of the performance of the various Pu isotope ratios as a function of total Pu content revealed accurate results (<3% relative difference, or RD) above ∼50 fg total Pu. The results presented here demonstrate the capability of the MC-ICP-MS/MS making accurate and precise low level Pu isotopic measurements. While the intent of this work was not to investigate the functionality of the collision cell, the pre-mass filter was employed. Future studies are warranted to investigate the entire capability of the MC-ICP-MS/MS collision cell and pre-cell mass filter optimization for performing low level Pu isotope measurements, even in mixed matrix samples.

CRM↗

High rate studies of the ATLAS sTGC detector and optimization of the filter circuit on the input of the front-end amplifier

Abstract The Large Hadron Collider (LHC) at CERN is expected to be upgraded to the High-Luminosity LHC (HL-LHC) by 2029 and achieve instantaneous luminosity around 5–7.5 × 10 34 cm -2 s -1 . This represents a more than 3–4 fold increase in the instantaneous luminosity compared to what has been achieved in Run 2. The New Small Wheel (NSW) upgrade is designed to be able to operate efficiently in this high background rate environment. In this article, we summarize multiple performance studies of the small-strip Thin Gap Chamber (sTGC) at high rate using nearly final front-end electronics. We demonstrate that the efficiency versus rate distribution can be well described by an exponential decay with electronics dead-time being the primary cause of loss of efficiency at high rate. We then demonstrate several methods that can decrease the electronics dead-time and therefore minimize efficiency loss. One such method is to install either a pi-network input filter or pull-up resistor to minimize the charge input into the amplifier. We optimized the pi-network capacitance and pull-up resistor resistance using the results from our measurements. The results shown here were not only critical to finalizing the components on the front-end board, but also are critical for setting the optimal operating parameters of the sTGC detector and electronics in the ATLAS cavern.

Instruments & Instrumentation↗

Consistent boundary conditions for PDE filter regularization in topology optimization

Abstract Design variables in density-based topology optimization are typically regularized using filtering techniques. In many cases, such as stress optimization, where details at the boundaries are crucially important, the filtering in the vicinity of the design domain boundary needs special attention. One well-known technique, often referred to as “padding,” is to extend the design domain with extra layers of elements to mitigate artificial boundary effects. We discuss an alternative to the padding procedure in the context of PDE filtering. To motivate this augmented PDE filter, we make use of the potential form of the PDE filter which allows us to add penalty terms with a clear physical interpretation. The major advantages of the proposed augmentation compared with the conventional padding is the simplicity of the implementation and the possibility to tune the boundary properties using a scalar parameter. Analytical results in 1D and numerical results in 2D and 3D confirm the suitability of this approach for large-scale topology optimization.

42 ENGINEERING↗

Near Optimality of Matched Filter Detection for Cyclic Prefix Direct Sequence Spread Spectrum

Abstract—Cyclic Prefix Direct Sequence Spread Spectrum -DSSS) has been presented as a potential solution for ultrareliable low latency communications (URLLC) and massive machine type communication (mMTC), where the CP-DSSS waveform would operate as a secondary network at the same frequencies as the primary network but at much lower SNR. In this paper, we show that when operating in the low SNR regime, CP-DSSS achieves near optimum performance when using a matched filter (MF) detector at the receiver. Time reversal (TR) precoding at the transmitter is also analyzed. These results also carry forward into multi-antenna scenarios where array gain is preserved. With nearly optimal performance of MF detection, CP-DSSS can be implemented with simple device transceiver structures, reducing per-unit cost for massively deployed networks.

5G and Beyond Communications↗

Optimal Modulation and DM Filter Design for a High Switching Frequency Single-Stage Microinverter

This paper presents an optimal modulation and systematic filter design approach for a single-stage dual-active-bridge (DAB) based dc-ac microinverter to achieve improved differential-mode (DM) noise performance for electromagnetic interference (EMI) tests. As DM filters contribute significantly to the overall converter volume, the main objective of this work is to leverage the degrees of freedom in the DAB converters to effectively attenuate the EMI noise. In addition, the DM filter design method needs to ensure near unity power factor converter operation. To achieve these targets, this paper analyzes three modulation strategies based on fixed or variable switching frequency operation where the different control modulation variables are varied to find the simulated DM noise spectrum. Based on the required DM attenuation, a constrained optimization problem is formulated to determine minimal DM filter parameters. Simulation results show that a spread spectrum approach with variable switching frequency is shown to minimize the DM EMI attenuation effort by spreading the noise profile. A fully GaN 400 W hardware prototype demonstrated the spread-sprectrum approach.

14 SOLAR ENERGY↗

Improving reproducibility in synchrotron tomography using implementation-adapted filters

For reconstructing large tomographic datasets fast, filtered backprojection-type or Fourier-based algorithms are still the method of choice, as they have been for decades. These robust and computationally efficient algorithms have been integrated in a broad range of software packages. The continuous mathematical formulas used for image reconstruction in such algorithms are unambiguous. However, variations in discretization and interpolation result in quantitative differences between reconstructed images, and corresponding segmentations, obtained from different software. This hinders reproducibility of experimental results, making it difficult to ensure that results and conclusions from experiments can be reproduced at different facilities or using different software. In this paper, a way to reduce such differences by optimizing the filter used in analytical algorithms is proposed. These filters can be computed using a wrapper routine around a black-box implementation of a reconstruction algorithm, and lead to quantitatively similar reconstructions. Use cases for this approach are demonstrated by computing implementation-adapted filters for several open-source implementations and applying them to simulated phantoms and real-world data acquired at the synchrotron. Our contribution to a reproducible reconstruction step forms a building block towards a fully reproducible synchrotron tomography data processing pipeline.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Applying Particle Swarm Optimization and Extended Kalman Filtering to Model Kaplan Generation Dynamics for Hydropower Systems

Variable renewable generation is increasing the need for hydropower plants to provide fast and flexible grid support, which places new demands on plant-level dynamic models used for monitoring, control, and operational decision-making. This need is especially important for hydroelectric systems, where turbine and generator dynamics are strongly coupled, nonlinear, and time-varying, making accurate real-time representation difficult. To address this problem, this paper develops a digital twin (DT) framework for a synchronous generator–Kaplan turbine system using an explicit separation of slow turbine dynamics and fast generator dynamics. The turbine subsystem is represented by a six-coefficient model, whose parameters are identified offline using particle swarm optimization, while the generator subsystem is updated online through an extended Kalman filter for real-time state and parameter estimation. These models are integrated within a closed-loop simulation that includes a proportional–integral–derivative–double-derivative governor and excitation system, allowing the DT to track plant behavior under realistic operating conditions. Unlike prior studies that treat turbine and generator modeling separately or rely mainly on simulated inputs, the proposed framework is validated using real operational data from a hydropower plant. Results show that the DT reproduces terminal voltage, active power, and reactive power with a normalized root mean square error of approximately 5%. This hybrid offline–online formulation constitutes the main contribution of the work, providing an adaptive and practically deployable DT for hydropower systems with direct relevance to control improvement, performance monitoring, and grid-support applications under high renewable penetration.

13 HYDRO ENERGY↗

Optimizing photonic ring-resonator filters for OH-suppressed near-infrared astronomy

Near-infrared wavelength observations are crucial for understanding numerous fields of astrophysics, such as supernova cosmology and positronium annihilation detection. However, current ground-based observations suffer from an enormous background due to OH emission in the upper atmosphere. One promising way to solve this problem is to use ring-resonator filters to suppress OH emission lines. Here, we discuss our optimization of ring-resonator filter performance from five perspectives: resonance wavelength matching, polarization-independent operation, low insertion loss, low-loss coupling to astronomical instruments, and broadband operation. In the end, we discuss next steps needed for reliable supernova and positronium observations, thus providing a roadmap for future advances in near-infrared astronomy.

42 ENGINEERING↗

Low Energy Neutron-induced Charged-particle (Z) (LENZ) instrument development with a focus on pulse shape discrimination for low-energy charged particles

To study neutron-induced charged-particle reactions with high precision, the Low Energy Neutron-induced Charged-particle (Z) instrument (LENZ) was developed at the Los Alamos Neutron Science Center. For the interest of measuring (n,p) and (n, α) reactions simultaneously, Pulse Shape Discrimination methods were investigated to identify different charged particles in the energy range of 3 - 20 MeV and improve signal-to-background ratios using Double-sided Silicon Strip Detectors and waveform digitizers. The risetime and pulse shape properties of detected charged particles were characterized for various silicon detector’s thickness with different orientations. During the post-processing of waveforms, we implemented different digital filters for effective particle identifications and improved energy- and timing- resolutions. We validated the optimized digital filters and pulse shape analyses, via measurements with 228 Th and 229 Th calibration sources, proton-induced reactions on a 7 LiF target, and neutron-induced reactions on CH 2 , Ta 2 O 5 , 58 Ni, and 6 LiF/ 59 Ni targets at the time-of-flight facility, LANSCE. In conclusion, the summary of effective thresholds and Figure of Merits on separating different charged particles is reported.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Implementation and optimization of the PTOLEMY transverse drift electromagnetic filter

The PTOLEMY transverse drift filter is a new concept to enable precision analysis of the energy spectrum of electrons near the tritium β-decay endpoint. Here, we detail the implementation and optimization methods for successful operation of the filter for electrons with a known pitch angle. We present the first demonstrator that produces the required magnetic field properties with an iron return-flux magnet. Two methods for the setting of filter electrode voltages are detailed. The challenges of low-energy electron transport in cases of low field are discussed, such as the growth of the cyclotron radius with decreasing magnetic field, which puts a ceiling on filter performance relative to fixed filter dimensions. Additionally, low pitch angle trajectories are dominated by motion parallel to the magnetic field lines and introduce non-adiabatic conditions and curvature drift. To minimize these effects and maximize electron acceptance into the filter, we present a three-potential-well design to simultaneously drain the parallel and transverse kinetic energies throughout the length of the filter. These optimizations are shown, in simulation, to achieve low-energy electron transport from a 1 T iron core (or 3 T superconducting) starting field with initial kinetic energy of 18.6 keV drained to < 10 eV (< 1 eV) in about 80 cm. This result for low field operation paves the way for the first demonstrator of the PTOLEMY spectrometer for measurement of electrons near the tritium endpoint to be constructed at the Gran Sasso National Laboratory (LNGS) in Italy.

47 OTHER INSTRUMENTATION↗

Angular-spectral filtering of recoil protons for optimization of fast neutron imaging employing proton converters

Fast neutron imaging is an important capability for diverse applications such as inertial confinement fusion diagnostics, cargo security, nuclear nonproliferation and arms control, and industrial inspection. Traditional phosphor image plates can be enhanced for fast neutron imaging using hydrogenous plastic converters which allow fast neutrons to scatter off hydrogen nuclei to produce energetic protons that can be recorded by the image plate. However, protons emitted by image plates are not constrained in their emission angle, which contributes to the blur of the resulting image. Here, we investigate two methods that can alter the spatial extent of converted protons that deposit energy in the image plate: reducing the converter thickness, and introducing a proton filter between the plastic converter and image plate to reduce the contribution of lower-energy, off-axis protons to the image. Here we determine the optimal plastic converter thickness for maximizing the signal intensity to be 2–3 mm through Monte Carlo simulations, and we benchmark this result against experimental measurements with a deuterium-tritium (DT) neutron generator. Next, we evaluate the image smearing and signal loss for various converters to show that solely reducing the converter thickness has the expected effect of reducing the blur from proton image smearing of the sharpness of an edge recorded on the image plate at the cost of reducing the signal intensity. The use of a proton filter is shown to achieve a similar improvement of edge sharpness as reducing the converter thickness while also sacrificing the signal intensity. We conclude that the use of proton energy filtering can improve the sharpness of fast neutron images in situations where the converter thickness cannot be reduced below some practical minimum. For more intense neutron sources, the signal intensity is of less concern, and optimizing the resolution of the image plate and therefore of the imaging system could have greater value. In these applications, proton filters may allow for improved fast neutron imaging measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Region of Interest Filter in DUNE DAQ

The Deep Underground Neutrino Experiment (DUNE) is the next generation neutrino experiment currently under construction. It consists of a broadband neutrino beam at Fermilab, a high precision near detector, and the largest liquid argon time projection chamber far detector ever designed at the Sanford Underground Research Facility (SURF). The Region of Interest (ROI) filter is designed for DUNE’s online Data Acquisition (DAQ) system to address data rate constraints and enable low energy physics in the <10 MeV range. The filter employs zero suppression on the detector signal, and by tuning the readout window and threshold the data rates can be reduced by >90%. Performance of the ROI is analyzed in LArsoft on MARLEY generated low energy MC events propagated through the detector simulation. Notably, the optimized ROI filter enables a lower trigger threshold for readout at ~5-10 MeV, allowing DUNE to explore low-energy physics, specifically focusing on solar boron 8 neutrinos which are relevant in this energy range. This advancement enhances DUNE's scientific capabilities, opening avenues for detailed analyses of previously inaccessible low-energy neutrino interactions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Startup regime of high-efficiency tapering-enhanced FEL oscillator

In this paper, we present a design of a high-efficiency high-gain free-electron laser oscillator based on the use of a strongly tapered undulator for extracting energy from high-brightness electron beams. We provide an analytical model of the setup followed by numerical simulations for lasing at the wavelength of 13.5 nm. We discuss the optimization of the system in steady state and the conditions necessary for the pass-per-pass buildup of the power from shot noise level. We propose the use of fast phase shifters as a way to accelerate the buildup. Finally, we present time-dependent simulations of the oscillator and discuss the role of spectral filtering. The optimized working point yields a total energy conversion efficiency from the electron beam to output radiation above 1% at the wavelength of 13.5 nm.

Beam dynamics↗

The gravitational lensing imprints of DES Y3 superstructures on the CMB: a matched filtering approach

Low-density cosmic voids gravitationally lens the cosmic microwave background (CMB), leaving a negative imprint on the CMB convergence |$\kappa$|⁠. This effect provides insight into the distribution of matter within voids, and can also be used to study the growth of structure. We measure this lensing imprint by cross-correlating the Planck CMB lensing convergence map with voids identified in the Dark Energy Survey Year 3 (DES Y3) data set, covering approximately 4200 deg|$^2$| of the sky. We use two distinct void-finding algorithms: a 2D void-finder that operates on the projected galaxy density field in thin redshift shells, and a new code, Voxel, which operates on the full 3D map of galaxy positions. We employ an optimal matched filtering method for cross-correlation, using the Marenostrum Institut de Ciències de l’Espai N-body simulation both to establish the template for the matched filter and to calibrate detection significances. Using the DES Y3 photometric luminous red galaxy sample, we measure |$A_\kappa$|⁠, the amplitude of the observed lensing signal relative to the simulation template, obtaining |$A_\kappa = 1.03 \pm 0.22$| (⁠|$4.6\sigma$| significance) for Voxel and |$A_\kappa = 1.02 \pm 0.17$| (⁠|$5.9\sigma$| significance) for 2D voids, both consistent with Lambda cold dark matter expectations. We additionally invert the 2D void-finding process to identify superclusters in the projected density field, for which we measure |$A_\kappa = 0.87 \pm 0.15$| (⁠|$5.9\sigma$| significance). The leading source of noise in our measurements is Planck noise, implying that data from the Atacama Cosmology Telescope, South Pole Telescope and CMB-S4 will increase sensitivity and allow for more precise measurements.

79 ASTRONOMY AND ASTROPHYSICS↗

Optimal polynomial based quantum eigenstate filtering with application to solving quantum linear systems

We present a quantum eigenstate filtering algorithm based on quantum signal processing (QSP) and minimax polynomials. The algorithm allows us to efficiently prepare a target eigenstate of a given Hamiltonian, if we have access to an initial state with non-trivial overlap with the target eigenstate and have a reasonable lower bound for the spectral gap. We apply this algorithm to the quantum linear system problem (QLSP), and present two algorithms based on quantum adiabatic computing (AQC) and quantum Zeno effect respectively. Both algorithms prepare the final solution as a pure state, and achieves the near optimal $\mathcal{\tilde{O}}$(dκlog(1/ϵ)) query complexity for a d -sparse matrix, where κ is the condition number, and ϵ is the desired precision. Neither algorithm uses phase estimation or amplitude amplification.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗