Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “optimal accuracy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Large Language Model for Validation, Optical Calibration, and Learning (VOCAL) Distributed Temperature Sensing Interface

Distributed temperature sensing (DTS) using fiber optic sensors (FOS) offers a promising method for temperature measurements in advanced reactors, such as sodium fast reactors and molten salt cooled reactors. To support the calibration and validation of DTS measurements, Argonne National Laboratory developed the Validation, Optical Calibration, and Learning (VOCAL) software package. This report describes the integration of a local large language model (LLM) with a retrieval-augmented generation (RAG) system into the VOCAL interface to serve as an interactive user assistant. The LLM framework enhances the VOCAL platform’s accessibility to users by explaining interface components, clarifying inputs and outputs, and answering user queries dynamically in real-time. The accuracy of the LLM assistant performance was evaluated with 20 queries regarding the interface and its parameters using experimental data from the Thermal Hydraulic Experimental Test Article (THETA) facility. Results demonstrate that the LLM achieved a 95% accuracy rate, with a BERTScore of 0.8816 and SBERT value of 0.7417. Furthermore, validation of the RAG system within the LLM framework showed optimal accuracy with k-values between 1 and 2 using the k-refinement convergence test. The prompt perturbation analysis demonstrated good initial consistency for the RAG system, exhibiting the highest accuracy under punctuation variations and the greatest sensitivity under query reordering. Notably, the model’s errors were limited to data retrieval failures rather than factual hallucinations, reinforcing its baseline reliability. The integration of LLM provides a highly accurate, userfriendly enhancement to the VOCAL platform without disrupting its core computational capabilities for FOS calibration and validation.

Hong, Evan↗

Furthering Precision in Sentinel Node Navigational Surgery for Oral Cancer: a Novel Triple Targeting System

To describe an innovative sentinel lymph node (SLN) guidance approach using a radionuclide tracer, 3D augmented reality-guided imaging, and near infrared (NIR) fluorescence over-lay imaging with hand-held probes to optimize accuracy, efficiency, and precise navigation for sentinel node (SN) localization in head and neck cancer. In a cT1N0M0 squamous cell carcinoma of the tongue, pre-operative radionuclide lymphoscintigraphy was performed with a sentinel node-specific radiolabeled tracer. Intraoperatively, a 3D hand-held augmented reality (AR) scanning SPECT probe assessed concordance of the SN with pre-operative SPECT-CT images. The real-time optical video was linked to the SPECT-CT images for added precision. Final guidance to the SN was performed using ICG fluorescence imaging. Dynamic and SPECT-CT showed bilateral lymphatic drainage from the tumor. The 3D hand-held AR SPECT probe SN localization was concordant with pre-operative imaging. The optical video successfully demonstrated the lymphatic drainage in real-time through a unique overlay fluorescence image. The ICG localized to the same nodes identified by both the SPECT-CT and hand-held SPECT images. The use of dual radiation and fluorescence tracers improved SN detection, especially for SN close to the injection site. The hand-held probes allowed the surgeon to dissect continuously, without needing to change tools. The combination of augmented reality, nuclear medicine, and over-lay fluorescence imaging allowed greater accuracy for matching the preoperative imaging with intraoperative identification and precisely guiding the dissection. This method uniquely permitted the surgeon to efficiently dissect the SN with accurate visualization and optimal precision.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Methods for recalibration of mass spectrometry data

Disclosed are methods for recalibrating mass spectrometry data that provide improvement in both mass accuracy and precision by adjusting for experimental variance in parameters that have a substantial impact on mass measurement accuracy. Optimal coefficients are determined using correlated pairs of mass values compiled by matching sets of measured and putative mass values that minimize overall effective mass error and mass error spread. Coefficients are subsequently used to correct mass values for peaks detected in the measured dataset, providing recalibration thereof. Sub-ppm mass measurement accuracy has been demonstrated on a complex fungal proteome after recalibration, providing improved confidence for peptide identifications.

47 OTHER INSTRUMENTATION↗

Capabilities and applications of the Program to Optimize Simulated Trajectories (POST). Program summary document

The capabilities and applications of the three-degree-of-freedom (3DOF) version and the six-degree-of-freedom (6DOF) version of the Program to Optimize Simulated Trajectories (POST) are summarized. The document supplements the detailed program manuals by providing additional information that motivates and clarifies basic capabilities, input procedures, applications and computer requirements of these programs. The information will enable prospective users to evaluate the programs, and to determine if they are applicable to their problems. Enough information is given to enable managerial personnel to evaluate the capabilities of the programs and describes the POST structure, formulation, input and output procedures, sample cases, and computer requirements. The report also provides answers to basic questions concerning planet and vehicle modeling, simulation accuracy, optimization capabilities, and general input rules. Several sample cases are presented.

Brauer, G. L.↗

State of the art in electromagnetic modeling for the Compact Linear Collider

SLAC's Advanced Computations Department (ACD) has developed the parallel 3D electromagnetic time-domain code T3P for simulations of wakefields and transients in complex accelerator structures. T3P is based on state-of-the-art Finite Element methods on unstructured grids and features unconditional stability, quadratic surface approximation and up to 6th-order vector basis functions for unprecedented simulation accuracy. Optimized for large-scale parallel processing on leadership supercomputing facilities, T3P allows simulations of realistic 3D structures with fast turn-around times, aiding the design of the next generation of accelerator facilities. Applications include simulations of the proposed two-beam accelerator structures for the Compact Linear Collider (CLIC) - wakefield damping in the Power Extraction and Transfer Structure (PETS) and power transfer to the main beam accelerating structures are investigated.

43 PARTICLE ACCELERATORS↗

Nonlinear elasticity with the Shifted Boundary Method

Here, we propose a new unfitted/immersed computational framework for nonlinear solid mechanics, which bypasses the complexities associated with the generation of CAD representations and subsequent body-fitted meshing. This approach allows to speed up the cycle of design and analysis in complex geometry and requires relatively simple computer graphics representations of the surface geometries to be simulated, such as the Standard Tessellation Language (STL format). Complex data structures and integration on cut elements are avoided by means of an approximate boundary representation and a modification (shifting) of the boundary conditions to maintain optimal accuracy. An extensive set of computational experiments in two and three dimensions is included.

97 MATHEMATICS AND COMPUTING↗

Matrix-free subcell residual distribution for Bernstein finite elements: Monolithic limiting

This paper is focused on the aspects of limiting in residual distribution (RD) schemes for high-order finite element approximations to advection problems. Both continuous and discontinuous Galerkin methods are considered in this work. Discrete maximum principles are enforced using algebraic manipulations of element contributions to the global nonlinear system. The required modifications can be carried out without calculating the element matrices and assembling their global counterparts. The components of element vectors associated with the standard Galerkin discretization are manipulated directly using localized subcell weights to achieve optimal accuracy. Low-order nonlinear RD schemes of this kind were originally developed to calculate local extremum diminishing predictors for flux-corrected transport (FCT) algorithms. In the present paper, we incorporate limiters directly into the residual distribution procedure, which makes it applicable to stationary problems and leads to well-posed nonlinear discrete problems. To circumvent the second-order accuracy barrier, the correction factors of monolithic limiting approaches and FCT schemes are adjusted using smoothness sensors based on second derivatives. Finally, the convergence behavior of presented methods is illustrated by numerical studies for two-dimensional test problems.

97 MATHEMATICS AND COMPUTING↗

EHR-BERT: A BERT-based model for effective anomaly detection in electronic health records

Objective: Physicians and clinicians rely on data contained in electronic health records (EHRs), as recorded by health information technology (HIT), to make informed decisions about their patients. The reliability of HIT systems in this regard is critical to patient safety. Consequently, better tools are needed to monitor the performance of HIT systems for potential hazards that could compromise the collected EHRs, which in turn could affect patient safety. In this paper, we propose a new framework for detecting anomalies in EHRs using sequence of clinical events. This new framework, EHR-Bidirectional Encoder Representations from Transformers (BERT), is motivated by the gaps in the existing deep-learning related methods, including high false negatives, sub-optimal accuracy, higher computational cost, and the risk of information loss. EHR-BERT is an innovative framework rooted in the BERT architecture, meticulously tailored to navigate the hurdles in the contemporary BERT method; thus, enhancing anomaly detection in EHRs for healthcare applications.Methods: The EHR-BERT framework was designed using the Sequential Masked Token Prediction (SMTP) method. This approach treats EHRs as natural language sentences and iteratively masks input tokens during both training and prediction stages. This method facilitates the learning of EHR sequence patterns in both directions for each event and identifies anomalies based on deviations from the normal execution models trained on EHR sequences.Results: Extensive experiments on large EHR datasets across various medical domains demonstrate that EHR-BERT markedly improves upon existing models. It significantly reduces the number of false positives and enhances the detection rate, thus bolstering the reliability of anomaly detection in electronic health records. This improvement is attributed to the model’s ability to minimize information loss and maximize data utilization effectively.Conclusion: EHR-BERT showcases immense potential in decreasing medical errors related to anomalous clinical events, positioning itself as an indispensable asset for enhancing patient safety and the overall standard of healthcare services. The framework effectively overcomes the drawbacks of earlier models, making it a promising solution for healthcare professionals to ensure the reliability and quality of health data.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

High-performance high-resolution semi-Lagrangian tracer transport on a sphere

Current climate models have a limited ability to increase spatial resolution because numerical stability requires the time step to decrease. We describe a semi-Lagrangian method for tracer transport that is stable for arbitrary Courant numbers, and we test a parallel implementation discretized on the cubed sphere. The method includes a fixer that conserves mass and constrains tracers to a physical range of values. The method shows third-order convergence and maintains nonlinear tracer correlations to second order. It shows optimal accuracy at Courant numbers of 10-20, more than an order of magnitude higher than explicit methods. We present parallel performance in terms of strong scaling, weak scaling, and spatial scaling (where the time step stays constant while the resolution increases). For a 0.2° test with 100 tracers, the implementation scales efficiently to 10,000 MPI tasks.

Computer Science↗

SU-E-T-180: Fano Cavity Test of Proton Transport in Monte Carlo Codes Running On GPU and Xeon Phi

Purpose: In proton dose calculation, clinically compatible speeds are now achieved with Monte Carlo codes (MC) that combine 1) adequate simplifications in the physics of transport and 2) the use of hardware architectures enabling massive parallel computing (like GPUs). However, the uncertainties related to the transport algorithms used in these codes must be kept minimal. Such algorithms can be checked with the so-called “Fano cavity test”. We implemented the test in two codes that run on specific hardware: gPMC on an nVidia GPU and MCsquare on an Intel Xeon Phi (60 cores). Methods: gPMC and MCsquare are designed for transporting protons in CT geometries. Both codes use the method of fictitious interaction to sample the step-length for each transport step. The considered geometry is a water cavity (2×2×0.2 cm{sup 3}, 0.001 g/cm{sup 3}) in a 10×10×50 cm{sup 3} water phantom (1 g/cm{sup 3}). CPE in the cavity is established by generating protons over the phantom volume with a uniform momentum (energy E) and a uniform intensity per unit mass I. Assuming no nuclear reactions and no generation of other secondaries, the computed cavity dose should equal IE, according to Fano's theorem. Both codes were tested for initial proton energies of 50, 100, and 200 MeV. Results: For all energies, gPMC and MCsquare are within 0.3 and 0.2 % of the theoretical value IE, respectively (0.1% standard deviation). Single-precision computations (instead of double) increased the error by about 0.1% in MCsquare. Conclusion: Despite the simplifications in the physics of transport, both gPMC and MCsquare successfully pass the Fano test. This ensures optimal accuracy of the codes for clinical applications within the uncertainties on the underlying physical models. It also opens the path to other applications of these codes, like the simulation of ion chamber response.

60 APPLIED LIFE SCIENCES↗

WE-EF-BRA-04: Evaluation of Dosimetric Uncertainties in Individualized Targeted Radionuclide Therapy (TRT) Treatment Planning Using Pre-Clinical Data

Purpose: Dosimetry for targeted radionuclide therapy (TRT) is moving away from conventional model-based methods towards patient-specific approaches. To address this need, a Monte Carlo (MC) dosimetry platform was developed to estimate patient-specific therapeutic 3D dose distributions based on pre-treatment imaging. However, because a standard practice for patient-specific internal dosimetry has not yet been established, there are many sources of dosimetric uncertainties. The goal of this work was to quantify the sensitivity of various parameters on MC dose estimations. Methods: The ‘diapeutic’ agent, CLR1404, was used as a proof-of-principle compound in this work. CLR1404 can be radiolabeled with either {sup 124}I for PET imaging or {sup 131}I for radiotherapy or SPECT imaging. PET/CT images of 5 mice were acquired out to 240 hrs post-injection of {sup 124}I-CLR1404. The therapeutic {sup 131}I-CLR1404 absorbed dose (AD) distribution was calculated using a Geant4-based MC dosimetry platform. A series of sensitivity studies were performed. The variables that were investigated included the PET/CT voxel resolution, partial volume corrections (PVC), material segmentation, inter-observer contouring variability, and the pre-treatment image acquisition frequency. Results: Resampling the PET/CT voxel size between 0.2–0.8 mm resulted in up to a 13% variation in the mean AD. Application of the PVC increased the mean AD by 0.5–11.2%. Less than 1% differences in ROI mean AD were observed between the tissue segmentation schemes using 4 and 27 different material compositions. Inter-observer contouring variability led to up to a 20% CoV (stdev/mean) in the mean AD between the users. Varying the number and frequency of pre-treatment images used resulted in changes in mean AD up to 176% compared to the case using all 12 images. Conclusion: Voxel resolution, contour segmentation, the image acquisition protocol most significantly impacted patient-specific TRT dosimetry. Further work is needed to develop a standard protocol that optimizes accuracy and efficiency for patient-specific internal dosimetry. BT and JG are affiliated with Cellectar Biosciences which owns the licensing rights to CLR1404 and related compounds.

60 APPLIED LIFE SCIENCES↗

JANUS: Resilient and Adaptive Data Transmission for Enabling Timely and Efficient Cross-Facility Scientific Workflows

In modern science, the growing complexity of large-scale scientific projects has led to an increasing reliance on cross-facility scientific workflows, where resources and expertise from multiple institutions and geographic locations are leveraged to accelerate scientific discovery. These workflows often require transmitting huge amounts of scientific data through wide-area networks. Although high-speed networks like ESnet and transfer services such as Globus have improved data mobility, several challenges remain. The sheer volume of data can overwhelm network bandwidth, widely used transport protocols such as TCP suffer from inefficiencies due to retransmissions triggered by packet loss, and existing fault-tolerance mechanisms like erasure coding introduce substantial overhead. In this paper, we propose Janus, a resilient and adaptable data transmission approach designed for cross-facility scientific workflows. Unlike traditional TCP-based methods, Janus leverages UDP, integrates erasure coding for fault tolerance, and combines it with error-bounded lossy compression to reduce overhead. This novel design allows users to balance data transmission time and accuracy, optimizing transfer performance based on specific scientific requirements. Additionally, Janus dynamically adjusts erasure coding parameters in response to real-time network conditions, ensuring efficient data transfers even in fluctuating environments. We develop optimization models for determining ideal configurations and implement adaptive data transfer protocols to enhance reliability. Through extensive simulations and real-network experiments, we demonstrate that Janus significantly improves transfer efficiency while maintaining data fidelity.

Esaulov, Vladislav [Georgia State University, Atla↗

Understanding machine learning approaches for partial differential equations

Recent works in computational physics have been successful in the super-resolution of numerical solutions of partial differential equations (PDEs) via neural networks. In this paper we explore the possibilities and limitations of the data-driven discretization approach implemented by Bar-Sinai et. al., while contrasting it with a simpler yet weaker approach utilizing the nangs Python library. The results demonstrate what neural network parameters optimize accuracy and performance, as well as what conditions on PDEs are necessary to maintain convergence.

97 MATHEMATICS AND COMPUTING↗

Millimeter-wave integrated-horn antennas. I - Theory. II - Experiment

Full-wave analysis is employed to determine the far-field pattern and input impedance of a dipole-fed horn antenna in a ground plane, and the theoretical results are compared with mm-wave and microwave data. The theoretical work exploits the Green's function corresponding to the horn structure and the method of moments. It is determined that the horn should have 70 sections/wavelength and 50 secondary modes for optimized accuracy, and certain dipole positions can reduce the resonance to zero. The experimentally derived impedance and radiation patterns agree with the constraints developed theoretically. The 70-degree flare-angle horn with selected dipole positions and horn apertures yields good radiation patterns, cross-polarization levels, and resonant dipole impedances. The conclusions are of interest to the development of the horn antennas etched in Si/GaAs for applications to zero-visibility tracking, radio astronomy, plasma diagnostics, and remote sensing.

Eleftheriades, George V.↗

A numerical treatment of geodynamic viscous flow problems involving the advection of material interfaces

Effective numerical treatment of multicomponent viscous flow problems involving the advection of sharp interfaces between materials of differing physical properties requires correction techniques to prevent spurious diffusion and dispersion. We develop a particular algorithm, based on modern shock-capture techniques, employing a two-step nonlinear method. The first step involves the global application of a high-order upwind scheme to a hyperbolic advection equation used to model the distribution of distinct material components in a flow field. The second step is corrective and involves the application of a global filter designed to remove dispersion errors that result from the advection of discontinuities (e.g., material interfaces) by high-order, minimally dissipative schemes. The filter introduces no additional diffusion error. Nonuniform viscosity across a material interface is allowed for by the implementation of a compositionally weighted-inverse interface viscosity scheme. The combined method approaches the optimal accuracy of modern shock-capture techniques with a minimal increase in computational time and memory. A key advantage of this method is its simplicity to incorporate into preexisting codes be they finite difference, element, or volume of two or three dimensions.

Lenardic, A.↗

A 3-Channel Algorithm for Retrieving Spatially and Temporally Continuous Cloud Properties Across Different Geostationary Satellite Imagers

Cloud property retrieval algorithms for passive satellite imagers are generally designed to take advantage of all the useful spectral information available for a particular satellite. This strategy optimizes accuracy and reduces misidentification and retrieval biases, particularly for modern satellites with many spectral channels. However, the application of dissimilar algorithms tailored for different satellite sensor scan present a problem within the climate data record (CDR). Algorithm inconsistencies can introduce artificial trends in the CDR that are tied to instrument changes rather than physical changes, especially when older satellites with limited spectral information are included. The NASA CERES (Clouds and the Earth’s Radiant Energy System) data record provides global cloud property retrievals across 23 years and more than 25 satellites. With the goal of producing a spatially and temporally continuous record of cloud properties, the CERES cloud working group has developed algorithms that use only 3 channels that are common to most geostationary satellite imagers: 0.65, 3.9, and 10.8 μm.

Sarah Bedka↗

Evaluating Property Model Accuracy for Cost Optimization of Desalination Technologies

Conference presentation conveying work conducted on property modeling and implications on cost optimization of seawater desalination technology. The authors assess the accuracy of four different property modeling approaches to represent thermodynamic properties of seawater. These properties are used with process flowsheets that include either reverse osmosis or mechanical vapor compression. The accuracy of property estimation is related to deviations in process design and levelized cost.

Sakhai, Savannah↗

Star Tracker Accuracy Improvement and Optimization for Attitude Measurement in Three-Axis

High precision attitude measurement systems obviate the need for the beacon from the receiver making it possible for the spacecraft to beam a laser communications signal to a ground station without the ground station advertising its location. The research presented targets new detection and estimation methods to improve the accuracy in locating stars on a focal plane detector, and an understanding of the effects of changes in the optics design parameters and aberration, including defocus, on the navigation solution itself. This understanding can lead to an optimization of the attitude solution with respect to those optics realm parameter changes. The methodology discussed includes the development of a model of a current star tracker system. Using this model, multiple algorithms are implemented, including a multi-hypothesis method (MHT), to detect and estimate the position of the stars on the focal plane detector. It will be shown that using the MHT for detection and estimation, a greater accuracy can be found for each star estimation from more traditional detection and estimation algorithms. The approach then uses the model to develop statistics of the star tracker and the attitude estimation outputs to understand the accuracy, or variance, of the system's attitude solution. This solution is repeated for a range of defocus aberration, and a lower limit to the variance of the attitude solution is shown. A Cramer Rao lower bound solution is derived for the star tracker system and the results are compared to the Monte Carlo analysis from the model and shown to correlate very well. The approach uses a star image not as a Gaussian spot on the focal plane as done in previous work, and use of an image that includes the effects of aberrations of the optic system, and the effects of under-sampling and noise from the focal plane detector as well. Analysis includes exploring a star tracker's accuracy improvement through the combination of focus error and under-sampling effects alone, possibly contradicting conventional wisdom and approaches.

Lichter, Michael J.↗