Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “operational considerations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

STREAM: A technology planning and capacity expansion model for the industrial sector

The Strategic Technology Roadmapping and Energy, Environmental, and Economic Analysis Model—STREAM—is an optimization-based modeling tool and analysis framework to assist with strategic planning and technology investments of the industrial sector. This open-source framework is written in Julia using the JuMP package, which enables users to model future “pathways” for incumbent and future production technologies, costs, fuels and energy carriers, and energy and non-energy environmental impacts from industries as they transform in pursuit of a robust and competitive manufacturing sector. The model starts with an initial stock of industrial production technologies and assets at a facility level and then determines pathways that minimize cost, subject to an array of possible constraints on demand, market shares, environmental flows, and other exogenously specified operational considerations such as capacity utilization rates or regional energy costs. Key features of the framework include flexibility to model a wide range of industries and industrial technologies/processes at varying levels of granularity, ability to perform parametric sensitivity analyses, and ability to visualize model results using visualization objects.

capacity expansion↗

Electroprecipitation Mechanism Enabling Silica and Hardness Removal through Aluminum-Based Electrocoagulation

We evaluate the effectiveness of an aluminum-based electrocoagulation pretreatment system to remove dissolved silica and hardness. Silica and hardness limit water recovery during membrane-based desalination applications when silica and hardness exceed the solubility limit and generate scale on the membrane surface. We show that simultaneous removal of nearly all silica (95 ± 4%) and a significant amount of hardness (40–60%) occurs with a hydraulic residence time of 2 h and a charge loading between 0 and 1200 C/L. Increasing the residence time maximized the hardness removal (58 ± 8%) via the formation of larger flocs, which allowed for more constituent removal by gravity settling. We highlight the trade-offs between improved energy efficiency at lower charge loadings and an improved removal rate at a higher charge loading. We further compare the percentage of silica and hardness removed in multicomponent solutions and compare this to single component feed solution. We discuss the implications that operational considerations have in terms of cost and treatment capacity. Finally, a cost–benefit analysis comparing chemical coagulation with electrocoagulation indicates that electrocoagulation could be half the cost of chemical coagulation and could produce more stable effluent pH and conductivity.

36 MATERIALS SCIENCE↗

Agent-Based Coordination Scheme for PV Integration (ABC4PV)

Renewables and especially photovoltaics (PV) have benefitted significantly from a host of incentives and policies targeted toward enhanced integration and adoption of specific energy technologies. However, with the push to move forward into a subsidy-free market framework, behind-the-meter residential PV applications have generally struggled to retain their value (unlike utility scale and commercial projects) [1]. This project focused on developing control-theoretic solutions aimed at improving the integration and interaction of behind-the-meter residential PV with other distribution system assets (controllable and non-controllable) to enhance the integrated value of residential PV. To this end, a suite of decentralized control methodologies have been developed to enable effective coordination and control of behind-the-meter residential load customers’ PV, battery storage systems (BSS), controllable loads and other similar assets within a distribution feeder. This interaction aims at procuring energy savings and, thus, energy bill savings. The main source of savings is drawn from reducing the effect of demand charge pricing and is realized at the feeder level, assuming community level interaction and management among the aforementioned assets. Optimal control of the assets is implemented with a distributed optimization methodology, leveraging consensus-based algorithms. The results gathered from the optimal control simulations demonstrates that the savings can be duly achieved and the algorithm decision times (to dynamically control asset set points, for example) are fast. As for the overall efficiency of PV+BSS systems, to procure energy savings from curtailment of the demand charge pricing effects, the optimal control is set up so as to minimize the variance of the load for all customers, throughout a feeder and throughout time in a rolling horizon scheduling with model predictive control. The control takes into account inter-temporal electrochemical storage (battery) degradation costs: specifically, we have developed a long-term lifetime model for the BSS that weighs in the effect of the degradation factor in the dispatch formulations, thus, a considerable operating cost that affects energy decision making. The levelized cost of energy (LCOE – redefined for the purpose of quantifying asset integration effectiveness through the customers’ energy cost) is shown to be below the threshold set for the combined PV+BSS topology of $ 0.14/kWh for multiple cases of PV penetration all the way up to 50%, provided that a policy of shared ownership of and savings is in place. Further, the LCOE calculated for the case before the deployment PV+BSS systems is also achievable, i.e. the deployment of PV+BSS, if planned and scheduled optimally. will have no effect on customers’ energy costs. From the control methodology viewpoint, the developed consensus-based algorithms are shown to converge for a wide range of problem cases (spanning normal operating scenarios and contingencies), guaranteeing dispatch solutions under forecasting errors, communication break-downs and cyber-security attacks. The proposed control solutions are scalable and real-time implementable, with dispatch computations and device set-point updates converging in less than 2s in most practical instances of the above events.

14 SOLAR ENERGY↗

A Guide to Energy Master Planning of High-Performance Districts and Communities

This guide was developed with partners throughout the United States to demonstrate how implementing district-scale high-performance strategies can be successful and scalable approaches to achieving deep energy savings that increase affordability, improve resilience, reduce emissions, and foster economic development. This document serves as a framework for districts, campuses, and communities, illustrating an iterative process of building support for, planning, and implementing high-performance districts by engaging stakeholders, setting aggressive energy goals, completing technical and financial planning, and implementing a high-performance energy master plan. The information in this guide is based on a 3-year U.S. Department of Energy Zero Energy District Accelerator and a range of real-world examples of emerging high-performance districts. It is particularly useful for architects, planners, engineers, local government agencies, and real estate developers in the early phases of planning a district with high-performance or other deep energy goals. For the purposes of this guide, a high-performance district is a multibuilding development that achieves aggressive energy and related goals such as zero energy, carbon neutrality, sustainability, ultra-efficiency, etc. High-performance districts optimize energy efficiency to reduce energy loads and use renewable energy resources to meet the remaining loads whenever possible. The Energy Independence and Security Act of 2007 defines a high-performance building as “a building that integrates and optimizes on a life cycle basis all major high-performance attributes, including energy conservation, environment, safety, security, durability, accessibility, cost-benefit, productivity, sustainability, functionality, and operational considerations.” High-performance districts are collections of such buildings that take advantage of the synergies available when energy consumption and production are considered at a district level rather than one building at a time.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Feasibility Study for Disposal Control Rod Assemblies Using UNF-ST&DARDS As-Loaded Zion Dual Purpose Cask Models

This report documents an initial evaluation to support future use of disposal control rod assemblies (DCRAs) for post-closure criticality control in dual purpose canisters (DPCs). The work described herein is an extension of previous efforts performed by Walker using inputs generated by the Used Nuclear Fuel-Storage, Transportation & Disposal Analysis Resource and Data System (UNFST&DARDS) for the Zion site DPCs with as-loaded isotopic compositions. The results of this analysis demonstrate that there are multiple pathways to using DCRA for post-closure criticality control. Various configurations of DCRA material, diameter, number of rods per DCRA, and number and location of DCRAs within a DPC were shown to be effective in varying degrees for the set of DPCs analyzed by Walker. Because of the variations in DPC as-loaded isotopic compositions considered in an array of DCRA parametric sweeps, it can be concluded that a DPC-specific methodology is feasible (i.e., a one-size-fits-all approach may not be needed). Instead, the utility program created for this work can be expanded to develop capabilities to provide DPC-specific DCRA arrangements to limit cost and weight and to allow for operational considerations.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Preliminary Design of Engineering-Scale Salt Accident Analysis Facility to Support Molten Salt Reactor Licensing

Systems-level nuclear accident analysis codes for reactor licensing must be validated using experimental data that represent behaviors expected during actual full-scale accidents. Some behaviors may arise from coupled processes and only manifest at large scales. This report presents the preliminary design of the Salt Accident Analysis Facility (SAAF, pronounced “safe”), which is an experimental test facility to be constructed at Argonne that can be used to conduct integrated salt accident tests at an engineering scale. The measurement capabilities of the SAAF are based on previously developed methods and will provide the representative datasets that are needed to support molten salt reactor (MSR) licensing. Details of the design, the processes to be quantified, the measurement techniques for quantifying the processes, the variables that can be adjusted to simulate different accident scenarios, and operational considerations are presented herein. This report provides stakeholders the opportunity to give feedback on the test facility capabilities and planned analyses before it is constructed.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

An Overview of Potential Future Aviation Energy Carriers

Global jet fuel demand is projected to grow to 165 billion gallons by 2050 and there is growing interest in the aviation industry to understand the capabilities of alternative energy carriers. This report considers several potential energy carriers, reviewing their production potential, operational considerations, and economic implications to inform potential next steps in aeronautics research. The following energy carriers (i.e., fuels) were evaluated in this study for future use in aviation: sustainable aviation fuel (SAF) - both biomass-based and power-to-liquids (PtL) - based SAF - cryogenic hydrogen (LH 2 ) - also known as liquid hydrogen - liquefied natural gas (LNG), liquefied ethane (LE), and Jet X. The barriers and opportunities for the evaluated energy carriers vary. SAF is a commercially available drop-in fuel compatible with existing aircraft and infrastructure. SAF is limited by both higher prices and slow commercialization of multiple pathways using different feedstocks necessary to significantly grow supply. Cryogenic fuels, in contrast, have very different thermal, physical, and chemical properties than SAF and Jet A, requiring the construction of new airport storage and dispensing infrastructure and the design of new aircraft energy systems capable of mitigating heat transfer and boil-off. Cryogenic fuels offer an opportunity to diversify aviation fuel carriers from domestic energy relevant for both energy security and resilience. This means cryogenic fuels are more of a longer-term solution for aircraft but are worth exploring for potential future cost savings and emissions benefits. Jet X refers to non-drop-in liquid hydrocarbon fuels in the early stages of investigation seeking favorable properties. There are substantial barriers to non-drop-in liquid aviation fuels that are not compatible with existing aircraft and fuel infrastructure.

33 ADVANCED PROPULSION SYSTEMS↗

Cloud-Based Demonstration of the Eastern Interconnection Situational Awareness Monitoring System (ESAMS)

This report describes a cloud-based implementation and field demonstration of the Eastern Interconnection Situational Awareness and Monitoring System (ESAMS). ESAMS was developed to support the detection and source localization of forced oscillations using synchrophasor measurements from tie-lines connecting areas served by different reliability coordinators (RCs), so that RCs could better coordinate their response to wide-area events. A previous effort had identified deployment barriers associated with hosting shared situational awareness tools at a single RC. To address these barriers, ESAMS was migrated to Amazon Web Services and evaluated in a six-month field demonstration. ISO New England (ISO-NE) and PJM streamed data to the platform using AWS Direct Connect and a site-to-site VPN, respectively. The resulting multi-utility measurement footprint enabled regional source localization across major portions of the U.S. Eastern Interconnection and supported routine identification of oscillation events. During the final three months of the trial, 24 events above 2 MW/MVAR were detected. The largest detected oscillation approached a 25 MW peak-to-peak amplitude, and the longest persisted intermittently for more than 11 hours. The demonstration also assessed operational considerations—including data transfer volumes, end-to-end latency, and cloud computing costs—and found that network and compute requirements were modest relative to typical cloud capabilities while providing performance comparable to prior on-premises deployments. Overall, the results indicate that cloud hosting can provide a practical path to shared interconnection-wide oscillation monitoring. The cloud ESAMS demonstration establishes a foundation for broader utility participation and for building future wide-area analytics that leverage measurements across organizational boundaries.

Follum, James D.↗

Understanding Community Microgrids

Increasing need for distribution circuit reliability and resilience prompt a clearer understanding of community microgrid interconnection and operational requirements. While customer-owned, behind-the-meter microgrid implementation is not always simple, increasing demand for reliability has commercialized many installation approaches. This rapid commercialization has broadened industry understanding of single-customer microgrid integration. Moreover, off-grid behaviors of such microgrids are not required to meet utility standard interconnection requirements. However, multi-customer community microgrids (utility- or third-party operated), are less well explored and introduce more complex design and operational challenges. The control of DER along with distribution automation devices, unmanned operation, protection coordination, and other aspects makes community microgrids challenging to implement and operate in both on-grid and off-grid modes. This whitepaper is a technical primer for understanding community microgrids. It provides a foundation for understanding the components, configurations, design, and operational considerations for community microgrids.

14 SOLAR ENERGY↗

Comparison of Select Thermochemical Conversion Options for Municipal Solid Waste to Energy

This document provides a comparison of several thermochemical conversion options for municipal solid waste (MSW) - combustion, gasification, and pyrolysis - across various metrics such as products, number of current projects in the United States, capital and O&M costs, job development potential, emissions, and incentives associated with each pathway, as well as other parameters, such as operational considerations, land requirements, and public perception.

BIOMASS FUELS,ENVIRONMENTAL SCIENCES↗

Legal and Regulatory Aspects Related to Unmanned Aerial Systems (UAS) for Safeguards Implementation

The International Atomic Energy Agency (IAEA) is exploring the use of innovative technologies such as Unmanned Aerial Systems (UAS) to address safeguards verification challenges such as difficulties in accessing nuclear material in high radiation environments, and remotely located installations, as well as to increase the efficiency of safeguards implementation by automating repetitive and time-consuming tasks. As UAS continue to advance and their use becomes more frequent in high security conscious industries such as nuclear, their advantages in contributing to greater safety and security may weigh in favor of their use. However, as the IAEA begins to use these technologies, the legal, policy, and operational considerations associated with these advanced technologies will also need to be considered to identify any key opportunities, challenges, or areas of concern for the IAEA and its Member States. This paper will explore these areas and identify important considerations for the IAEA and its Member States to consider as the use of UAS is explored further for safeguards applications. It will also provide a series of recommendations for anticipating and addressing legal, regulatory, and policy challenges related to the use of UAS for safeguards implementation.

Siserman-Gray, Ioana-Cristina↗

Operation and Security Considerations for Heat Pipe Cooled Microreactors

Microreactors and small modular reactors (SMRs) are anticipated to be key elements in the United States' carbon-free energy portfolio, serving as reliable power sources for remote communities, disaster relief zones, extraterrestrial deployments, and backup power needs. Microreactors employ technologies that are substantially more advanced and recent compared to conventional reactors. Furthermore, they are of a drastically smaller scale and are designed to be operated in a diverse set of locations, offering operational flexibility and mobility. In addition, the autonomous or semi-autonomous operation of microreactors with minimal or no on-site staff is anticipated. These factors give rise to specific challenges with regards to their safety and security. The present work investigates considerations related to heat pipe operation, reactor transport, and cyber/cyberphysical security to ensure the indirect and direct consequences of nefarious actors’ actions are understood and can be mitigated by design or through physical security measures. In addition, future directions are proposed for consideration by both HPMR designers and for regulators.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Infiltration of molten fluoride salts in graphite: Phenomenology and engineering considerations for reactor operations and waste disposal

The possibility and consequences of salt-infiltration in graphite must be evaluated for graphite used in molten salt reactors (MSRs) and fluoride-salt-cooled high-temperature reactors (FHRs), which can be subjected to salt pressures as high as 500 kPa. The volume of graphite porosity infiltrated by salt can be measured by direct infiltration and it can be predicted from the graphite pore size distribution, the surface tension of the salt, and the contact angle between the graphite and the salt. While these three properties are believed to be insensitive to irradiation, the former can be impacted by chronic or acute oxidation, and the latter two are highly sensitive to the chemistry of the salt and to events such as air ingress. For MSRs, predictions based on nominal properties of salt and graphite reveal that few graphite grades would satisfy the 4 vol% limit set in the Molten Salt Reactor Experiment, and even fewer would satisfy the 0.5 vol% design target. For FHRs, infiltration limits have not been defined and depend on the effect of infiltration on graphite properties, which are discussed. A hypothesis is presented for properties that may be impacted by infiltration and for which future studies are needed.

36 MATERIALS SCIENCE↗

Workforce and Economic Development Considerations from the Operations and Maintenance of Wind Power Plants

As wind capacity in the United States grows, economic opportunities also emerge—supported by the development of the wind workforce, specifically in the operation and maintenance (O&M) phase. Moreover, almost all wind turbines in the United States—about 99%—are located in rural areas (American Wind Energy Association 2018). Communities in these rural areas can anticipate some degree of economic impact from the wind industry. However, the various stakeholders within these communities, such as local businesses and government officials, are not always fully informed of the workforce impacts caused by wind power plants during operational years (Stefek et al. 2019). Although several research studies have focused on workforce and economic impacts of land-based wind facilities (e.g., Tegen et al. 2014; Brown et al. 2012; Halvatzis and Keyser 2013), these studies focused on the quantity of workers and not on O&M workforce interactions with local communities, such as worker commuting and spending patterns. This report is intended to provide stakeholders and community decision makers with qualitative and quantitative information to enable informed decisions that support workforce planning around new wind energy deployment.

17 WIND ENERGY↗

Operations, maintenance, and cost considerations for PV+Storage in the United States

Battery storage systems are increasingly being installed at photovoltaic (PV) sites to address supply-demand balancing needs. Although there is some understanding of costs associated with PV operations and maintenance (O&M), costs associated with emerging technologies such as PV plus storage lack details about the specific systems and/or activities that contribute to the cost values. This study aims to address this gap by exploring the specific factors and drivers contributing to utility-scale PV plus storage systems (UPVS) O&M activities costs, including how technology selection, data collection, and related and ongoing challenges. Specifically, we used semi-structured interviews and questionnaires to collect information and insights from utility-scale owners and operators. Data was collected from 14 semi-structured interviews and questionnaires representing 51.1 MW with 64.1 MWh of installed battery storage capacity within the United States (U.S.). Differences in degradation rate, expected life cycle, and capital costs are observed across different storage technologies. Most O&M activities at UPVS related to correcting under-performance. Fires and venting issues are leading safety concerns, and owner operators have installed additional systems to mitigate these issues. There are ongoing O&M challenges due the lack of storage-specific performance metrics as well as poor vendor reliability and parts availability. Insights from this work will improve our understanding of O&M consideration at PV plus storage sites.

14 SOLAR ENERGY↗