Chemical Composition and Flow Velocity as a Function of Operating Conditions for an Arc Jet Heater

We have used laser-induced fluorescence (LIF) to carry out a detailed, systematic survey of the properties of the free stream of the 20 Megawatt Aerodynamic Heating Facility at NASA/Ames Research Center. In both air and nitrogen flows we have measured the atomic nitrogen absolute number density and flow velocity at each operating condition. In air flows we have also measured the atomic oxygen absolute number density and rotational/translational temperature at each operating condition. These results have been used to provide, for the first time, a direct, nonintrusive measurement of the enthalpy on the centerline of the flow. In addition, the observed arc jet properties can be used to test and improve computer simulations of the arc jet flow which include detailed chemical rate processes (especially nitrogen atom recombination) taking place during the supersonic expansion.

Bamford, Douglas J.↗

Altitude Performance of Modified J71 Afterburner with Revised Engine Operating Conditions

An investigation was conducted in an altitude test chamber at the NACA Lewis laboratory to determine the effect of a revision of the rated engine operating conditions and modifications to the afterburner fue1 system, flameholder, and shell cooling on the augmented performance of the J71-A-2 (x-29) turbo jet engine operating at altitude . The afterburner modifications were made by the manufacturer to improve the endurance at sea-level, high-pressure conditions and to reduce the afterburner shell temperatures. The engine operating conditions of rated rotational speed and turbine-outlet gas temperature were increased. Data were obtained at conditions simulating flight at a Mach number of 0.9 and at altitudes from 40,000 to 60,000 feet. The afterburner modifications caused a reduction in afterburner combustion efficiency. The increase in rated engine speed and turbine-outlet temperature coupled with the afterburner modifications resulted in the over-all thrust of the engine and afterburner being unchanged at a given afterburner equivalence ratio, while the specific fuel consumption was increased slightly. A moderate shift in the range of equivalence ratios over which the afterburner would operate was encountered, but the maximum operable altitude remained unaltered. The afterburner-shell temperatures were also slightly reduced because of the modifications to the afterburner.

Useller, James W.↗

System-state and operating condition sensitive control method and apparatus for electric power delivery systems

This invention provides a method and apparatus for determining a precise switching sequence for the power switching elements of electric power delivery systems of the on-off switching type and which enables extremely fast transient response, precise regulation and highly stable operation. The control utilizes the values of the power delivery system power handling network components, a desired output characteristic, a system timing parameter, and the externally imposed operating conditions to determine where steady state operations should be in order to yield desired output characteristics for the given system specifications. The actual state of the power delivery system is continuously monitored and compared to a state-space boundary which is derived from the desired equilibrium condition, and from the information obtained from this comparison, the system is moved to the desired equilibrium condition in one cycle of switching control. Since the controller continuously monitors the power delivery system's externally imposed operating conditions, a change in the conditions is immediately sensed and a new equilibrium condition is determined and achieved, again in a single cycle of switching control.

Burns, III, William Wesley↗

Effect of pyrolysis operating conditions on the catalytic co‐pyrolysis of low‐density polyethylene and polyethylene terephthalate with zeolite catalysts

Abstract In this study, the catalytic (co‐)pyrolysis of low‐density polyethylene (LDPE) and polyethylene terephthalate (PET) with HZSM‐5 and HY zeolite catalysts was conducted in a micro‐pyrolysis reactor coupled to a two‐dimensional gas chromatography system. Pyrolysis operating conditions, such as the pyrolysis temperature, the catalyst to feedstock (CF) ratio, and the LDPE:PET ratio, were varied. It was found that for the co‐pyrolysis of LDPE and PET, HZSM‐5 led to higher yields of C2‐C4 olefins and monoaromatic products. Lower CF ratios increased the yield of C2‐C4 olefins for LDPE pyrolysis, but decreased benzene yield for PET pyrolysis, concomitant with an increased yield in benzoic acid. A lower temperature of 400°C which was sufficient for the pyrolysis of LDPE, led to incomplete conversion of PET. Surface response diagrams were used to visualize the impact of the various pyrolysis operating conditions on the yield of C2‐C4 olefins and BTEX, which serve as target products for the circular economy.

Okonsky, Sean Timothy↗

Application of a First-Principles Anomalous Transport Model for Electrons to Multiple Hall Thrusters and Operating Conditions

We have developed a physics-based model based on a pseudo-particle description of the electron cyclotron drift instability. A key improvement of the model with respect to previous work is that linear theory is not applied in the event of wave saturation and deviations of electrons or ions from a Maxwellian distribution function. In the acceleration region, the anomalous collision frequency is computed as the minimum value necessary to prevent the electron drift velocity from exceeding the thermal velocity. A functional based on the electron equilibration time is defined to control the transition from high to low resistivity regions. The model was previously applied to a single Hall thruster at its nominal operating condition, showing promising results that captured accurately the location of the thruster’s acceleration region. In this paper, we extend the use of this firstprinciples models to two additional thrusters, also considering multiple operating conditions for each of them. Numerical results are compared to experimental measurements obtained with non-invasive laser induced fluorescence. In general, the agreement between experiments and simulations is good. The model is able to predict the location of the acceleration region for all cases. We observe however that fine details, such as changes in the plasma potential gradient within the acceleration regions, are not captured. The model is also insensitive to changes in the magnetic field strength while experiments show that small shifts in location (of less than 5% of the acceleration channel length) occur. We plan to address the weaknesses of our method with the help of physical insight gained from kinetic simulations of the acceleration region.

Chaplin, Vernon H.↗

Engine Operating Conditions that Cause Thermal-Fatigue Cracks in Turbojet-Engine Buckets

Five engine tests were conducted to definitely establish the failure mechanism of leading-edge cracking and to determine which conditions of engine operation cause the failures. Five groups of S-616 and M-252 buckets from master lots were run consecutively in the same J47-25 engine. The tests included a steady-state run at full-power conditions, rapid cycling between idle and rated speed, and three different start-stop tests. The first start-stop test consisted of cycles of start and stop with 5 minutes of idle speed before each stop; the second included cycles of start and stop but with 15 minutes of rated speed before each stop; the third consisted of cycles of gradual starts and normal stops with 5 minutes at idle speed before each stop. The test results demonstrated that the primary cause of leading-edge cracking was thermal fatigue produced by repeated engine starts. The leading edge of the bucket experiences plastic flow in compression during starts and consequently is subjected to a tensile stress when the remainder of the bucket becomes heated and expands. Crack initiation was accelerated when rated-speed operation was added to each normal start-stop cycle. This acceleration of crack formation was attributed to localized creep damage and perhaps to embrittlement resulting from overaging. It was demonstrated that leading-edge cracking can be prevented simply by starting the engine gradually.

Johnston, James R.↗

Equivalent-Circuit Models for Grid-Forming Inverters under Unbalanced Steady-State Operating Conditions: Preprint

Positive- and negative-sequence equivalent-circuit models are put forth to capture the operation of grid-forming (GFM) inverters in unbalanced steady-state operating conditions acknowledging the impact of current limiting. The particular control architecture examined adopts droop control (for primary control), nested inner-current and outer-voltage control (in the stationary reference frame), and it is adaptable to two different types of current limiting (current-reference saturation and virtual-impedance limiting). We anticipate the proposed models to be of interest in modeling, analysis, and simulation of GFM inverters in unbalanced settings that may arise, e.g., in the face of faults. Validation of the equivalent-circuit models is pursued via comparison with full-order electromagnetic-transient (EMT) simulations for representative balanced and unbalanced faults.

equivalent-circuit models↗

Inner Front Pole Cover Erosion in the 12.5 kW HERMeS Hall Thruster Over a Range of Operating Conditions

Erosion characteristics on the cover of the inner front pole in a 12.5 kW Hall thruster were measured over a wide range of operating conditions in tests of 6 to 14 hours duration using an accelerated test method and a very sensitive radioactive tracer-based erosion diagnostic. The operating points included the nominal 300 - 600 V conditions on a constant 20.8 A throttle curve, but included additional conditions at other currents spanning the throttling envelope and measurements at varying magnetic eld strength, facility pressure, and discharge voltage oscillation amplitude. The results show that the 300 V condition produces the highest wear rates on the 20.8 A throttle curve, but that rates actually increase with decreasing current. The wear rate was insensitive to discharge voltage ripple, but increased monotonically with magnetic eld strength, particularly near the inner radius of the pole cover. The inner region was also sensitive to facility pressure, showing lower rates at a higher pressure level. Separate experiments in which the energy distributions of ions generated by the hollow cathode were measured suggest that the cathode plume may be a source of energetic ions responsible for some of the erosion trends, in addition to ions originating in the thruster plume. The Hall thruster simulation code Hall2De is able to reproduce the erosion characteristics observed at 600 V, 20.8 A, but cannot currently match the rates measured at lower voltages and currents.

Lopez Ortega, Alejandro↗

Using Degradation Modeling to Identify Fragile Operational Conditions in Human- and Component-driven Resilience Assessment

Studying failure events shows that many high-impact events result from the complex interactions between precipitating failure events and degraded operational conditions. Often, when a system is put in operations, unforeseen practical realities (e.g., maintenance and/or workforce availability) lead the system to be operated in configurations outside its envisioned nominal range. However, design-time failure models often assume that the failure events are initiated in an idealized, nominal state of system operation, resulting in an incomplete assessment of future risk. To solve this, this paper develops a framework to consider degraded operational performance in scenario-based resilience models which uses a corresponding model of performance degradation to determine the values of deteriorated model parameters in the resilience model. This framework is demonstrated on a remotely-piloted rover to determine the (individual and combined) effect of drive-train wear and operator fatigue on the resilience of the rover to drive-train faults. This demonstration showed the substantial impact that degradation has on resilience, highlighting the need to account for degradation in resilience models–specifically, unconsidered degradation can lead to overestimates of resilience (and thus underestimates of safety margin) and because resilience can degrade prior to visible unreliability, which can lead to an operational environment with a high propensity for high-impact unforeseen failure events.

resilience↗

Using Degradation Modeling to Identify Fragile Operational Conditions in Human- and Component-driven Resilience Assessment

Studying failure events shows that many high-impact events result from the complex interactions between precipitating failure events and degraded operational conditions. Often, when a system is put in operations, unforeseen practical realities (e.g., maintenance and/or workforce availability) lead the system to be operated in configurations outside its envisioned nominal range. However, design-time failure models often assume that the failure events are initiated in an idealized, nominal state of system operation, resulting in an incomplete assessment of future risk. To solve this, this paper develops a framework to consider degraded operational performance in scenario-based resilience models which uses a corresponding model of performance degradation to determine the values of deteriorated model parameters in the resilience model. This framework is demonstrated on a remotely-piloted rover to determine the (individual and combined) effect of drive-train wear and operator fatigue on the resilience of the rover to drive-train faults. This demonstration showed the substantial impact that degradation has on resilience, highlighting the need to account for degradation in resilience models--specifically, unconsidered degradation can lead to overestimates of resilience (and thus underestimates of safety margin) and because resilience can degrade prior to visible unreliability, which can lead to an operational environment with a high propensity for high-impact unforeseen failure events.

Daniel Hulse↗

Application of a temporal multiscale method for efficient simulation of degradation in PEM Water Electrolysis under dynamic operating conditions

Hydrogen is emerging as a vital energy carrier, driven by the need to reduce carbon emissions. Proton Electrolyte Membrane Water Electrolysis (PEMWE) enables hydrogen production under fluctuating renewable power conditions but requires improved understanding and stability of the anode catalyst layer under dynamic operating conditions, especially with low noble metal loadings. Long-term degradation experiments are both time-consuming and costly; therefore, a systematic, model-aided approach is essential. In the present work, a temporal multiscale method is applied to reduce the computational effort of simulating long-term degradation processes in PEMWE, with an exemplary focus on catalyst dissolution. A mechanistic model incorporating the oxygen evolution reaction, catalyst dissolution, and hydrogen permeation from the cathode to the anode was hypothesized and implemented. In this way, the local periodicity of transport and reaction processes in dynamic PEMWE operation, which influence the gradual degradation of the catalyst layer, is captured. The temporal multiscale method significantly reduces the computational effort of simulation, decreasing processing time from hours to mere minutes. This efficiency gain is attributed to the limited evolution of Slow-Scale variables during each period of time P of the Fast-Scale variables. Consequently, simulation is required only until local periodicity is achieved within each Slow-Scale time step. Hence, the fully resolved dynamic problem is decoupled into these two scales, employing a heterogeneous multiscale technique. The developed approach effectively accelerates parameter estimation and predictive simulations, supporting systematic modeling of PEMWE degradation under dynamic conditions.

08 HYDROGEN↗