Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “opacity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Sub-keV design for the National Ignition Facility’s soft x-ray Opacity Spectrometer (OpSpec) and expansion plans for time-resolved measurements

When compared with the National Ignition Facility’s (NIF) original soft x-ray opacity spectrometer, which used a convex cylindrical design, an elliptically shaped design has helped to increase the signal-to-noise ratio and eliminated nearly all reflections from alternate crystal planes. The success of the elliptical geometry in the opacity experiments has driven a new elliptical geometry crystal with a spectral range covering 520–1100 eV. When coupled with the primary elliptical geometry, which spans 1000–2100 eV, the new sub-keV elliptical geometry helps to cover the full iron L-shell and major oxygen transitions important to solar opacity experimentation. The new design has been built and tested by using a Henke x-ray source and shows the desired spectral coverage. Additional plans are underway to expand these opacity measurements into a mode of time-resolved detection, ~1 ns gated, but considerations for the detector size and photometrics mean a crystal geometry redesign. Here, the new low-energy geometry, including preliminary results from the NIF opacity experiments, is presented along with the expansion plans into a time-resolved platform.

47 OTHER INSTRUMENTATION↗

First Measurement of Z Opacity Sample Evolution near Solar Interior Conditions Using Time-Resolved Spectroscopy

Opacity model differences with Fe opacity measurements at high temperature (T>1⁢8⁢0 eV ) and high electron density (𝑛 𝑒 >3×10 22 cm −3 ) at nearly solar interior conditions have remained unresolved [Bailey et al., Nature 517, 56 (2015) and Nagayama et al., Phys. Rev. Lett. 122, 235001 (2019)]. Systematic errors from temporal gradients are one hypothesis for the discrepancy. Past data recorded on x-ray film provided spectral measurements over a time determined by the 2.8-ns backlighter duration. Here, we present the first measurements of opacity sample temporal evolution using novel hCMOS ultrafast x-ray camera technology. The measured conditions, measured backlighter time history, and modeled opacities are used to show that temporal gradients do not resolve the model-data discrepancy. The methods demonstrated provide potential advantages, including opacities at more extreme conditions, spectral line shift measurements, and improved measurements at other facilities.

atomic spectra↗

Tungsten disulfide nanotubes enhance flow-induced crystallization and radio-opacity of polylactide without adversely affecting in vitro toxicity

Treatment of vascular disease, from peripheral ischemia to coronary heart disease (CHD), is poised for transformation with the introduction of transient implants designed to “scaffold” regeneration of blood vessels and ultimately leave nothing behind. Improved materials could expand the use of these devices. Here, we examine one of the leading polymers for bioresorbable scaffolds (BRS), polylactide (PLA), as the matrix of nanocomposites with tungsten disulfide (WS 2 ) nanotubes (WSNT), which may provide mechanical reinforcement and enhance radio-opacity. We evaluate in vitro cytotoxicity using vascular cells, flow-induced crystallization and radio-opacity of PLA-WSNT nanocomposites at low WSNT concentration. A small amount of WSNT (0.1 wt%) can effectively promote oriented crystallization of PLA without compromising molecular weight. And radio-opacity improves significantly: as little as 0.5 to 1 wt% WSNT doubles the radio-opacity of PLA-WSNT relative to PLA at 17 keV. The results suggest that a single component, WSNT, has the potential to increase the strength of BRS to enable thinner devices and increase radio-opacity to improve intraoperative visualization. Here, the in vitro toxicity results indicate that PLA-WSNT nanocomposites are worthy of investigation in vivo. Although substantial further preclinical studies are needed, PLA-WSNT nanocomposites may provide a complement of material properties that may improve BRS and expand the range of lesions that can be treated using transient implants.

36 MATERIALS SCIENCE↗

In-depth analysis of solar models with high-metallicity abundances and updated opacity tables

Context. As a result of the high-quality constraints available for the Sun, we are able to carry out detailed combined analyses using neutrino, spectroscopic, and helioseismic observations. These studies lay the ground for future improvements of the key physical components of solar and stellar models because ingredients such as the equation of state, the radiative opacities, or the prescriptions for macroscopic transport processes of chemicals are then used to study other stars in the Universe. Aims. We study the existing degeneracies in solar models using the recent high-metallicity spectroscopic abundances by comparing them to helioseismic and neutrino data and discuss the effect on their properties of changes in the micro and macro physical ingredients. Methods. We carried out a detailed study of solar models computed with a high-metallicity composition from the literature based on averaged 3D models that were claimed to resolve the solar modelling problem. We compared these models to helioseismic and neutrino constraints. Results. The properties of the solar models are significantly affected by the use of the recent OPLIB opacity tables and the inclusion of macroscopic transport. The properties of the standard solar models computed using the OPAL opacities are similar to those for which the OP opacities were used. We show that a modification of the temperature gradient just below the base of the convective zone is required to remove the discrepancies in solar models, particularly in the presence of macroscopic mixing. This can be simulated by a localised increase in the opacity of a few percent. Conclusions. We conclude that the existing degeneracies and issues in solar modelling are not removed by using an increase in the solar metallicity, in contradiction to what has been suggested in the recent literature. Therefore, standard solar models cannot be used as an argument for a high-metallicity composition. While further work is required to improve solar models, we note that direct helioseismic inversions indicate a low metallicity in the convective envelope, in agreement with spectroscopic analyses based on full 3D models.

74 ATOMIC AND MOLECULAR PHYSICS↗

Sequential spectral line analysis for accurate density and temperature diagnosis of laboratory opacity measurements

The accuracy of iron opacity calculated in stellar interiors has been questioned since the discovery of the “solar problem” and the discrepancies between the measured and modeled iron opacity reported in 2015. Experimental opacity benchmarks require accurate temperature and density measurements, which were inferred by analyzing tracer magnesium spectra in those experiments. Could the observed discrepancy be explained by insufficient accuracy in the inferred temperature, density, and their uncertainties? Previous analyses may have yielded biased results due to three limitations: (1) simultaneous multi-line fitting, (2) approximations in line-shape models, and (3) exclusion of certain spectral lines due to insufficient background characterization. Notably, the first issue is a common concern for many inversion methods, including Bayesian inferences. We present a refined analysis method that overcomes these limitations, applied to three categories of iron opacity experiments (Anchor 1, 2, and 3). In particular, the sequential fitting method yields unbiased results with more realistic uncertainties by accounting for line inconsistencies in the parameter uncertainties. The average electron temperature and density values are 162 ± 6 eV and (7.0 ± 1.9) × 10 21 cm −3 for six Anchor 1 experiments, 189 ± 7 eV and (3.4 ± 0.3) × 10 22 cm −3 for 21 Anchor 2 experiments, and 201 ± 6 eV and (4.8 ± 1.1) × 10 22 cm −3 for nine Anchor 3 experiments. These results show ∼4% temperature and ∼20% density reproducibility over a decade, which also aligns with the inferred parameter uncertainties. In conclusion, the resulting temperature and density uncertainties lead to a quasi-continuum iron opacity variation of ±4%–7% for wavelengths below 9.5 Å, which is insufficient to explain the significant model-data discrepancies reported in 2015.

Absorption spectroscopy↗

R-matrix calculations for opacities: I. Methodology and computations

Abstract An extended version of the R -matrix methodology is presented for calculation of radiative parameters for improved plasma opacities. Contrast and comparisons with existing methods primarily relying on the distorted wave approximation are discussed to verify accuracy and resolve outstanding issues, particularly with reference to the opacity project (OP). Among the improvements incorporated are: (i) large-scale Breit–Pauli R -matrix calculations for complex atomic systems including fine structure, (ii) convergent close coupling wave function expansions for the ( e + ion) system to compute oscillator strengths and photoionization cross sections, (iii) open and closed shell iron ions of interest in astrophysics and experiments, (iv) a treatment for plasma broadening of autoionizing resonances as function of energy-temperature-density dependent cross sections, (v) a ‘top-up’ procedure to compare convergence with R -matrix calculations for highly excited levels, and (vi) spectroscopic identification of resonances and bound ( e + ion) levels. The present R -matrix monochromatic opacity spectra are fundamentally different from OP and lead to enhanced Rosseland and Planck mean opacities. An outline of the work reported in other papers in this series and those in progress is presented. Based on the present re-examination of the OP work, opacities of heavy elements might require revisions in high temperature-density plasma sources.

Pradhan, A. K. (ORCID:0000000187753643)↗

Time-dependent density functional theory applied to average atom opacity

We focus on studying the opacity of iron, chromium, and nickel plasmas at conditions relevant to experiments carried out at Sandia National Laboratories. In this work, we calculate the photoabsorption cross sections and subsequent opacity for plasmas using linear-response time-dependent density functional theory (TD-DFT). Our results indicate that the physics of channel mixing accounted for in linear-response TD-DFT leads to an increase in the opacity in the bound-free quasicontinuum, where the Sandia experiments indicate that models underpredict iron opacity. However, the increase seen in our calculations is only in the range of 5%–10%. Further, we do not see any change in this trend for chromium and nickel. This behavior indicates that channel mixing effects do not explain the trends in opacity observed in the Sandia experiments.

74 ATOMIC AND MOLECULAR PHYSICS↗

Addressing the impact of Lyman opacity in inference of divertor plasma conditions with 2D spectroscopic camera analysis of Balmer emission during detachment in JET L-mode plasmas

The impact of re-absorption of the deuterium Lyman series emission was addressed in inferring divertor plasma conditions from Balmer series emission with 2D spectroscopic camera analysis during detachment in JET L-mode plasmas. The previously presented methodology was amended by modifying the standard photon emission coefficients and ionization and recombination rate coefficients of the ADAS database to consider the re-population of excited states due to Lyman opacity. This resulted in the estimate for the atomic density near the outer strike point to decrease by up to 75% at the onset of detachment at strike point temperatures of T e,osp ≈ 1.0–3.0 eV with respect to the strongly overestimated previously obtained values, whereas the estimated electron temperature and density were unaffected by the opacity correction within the scatter of the data and only a moderate reduction by up to 20% was observed in the estimate for the molecularly induced fraction of the Balmer emission. No noticeable change was seen in the ionization rate, calculated from the estimated outer strike point conditions, due to the decrease in the atomic density estimate compensating for the increased values of the opacity-corrected ADAS rate coefficients for ionization. In detached conditions at T e,osp ≈ 0.5–1.0 eV, 25%–35% lower recombination rates were provided by the opacity-corrected model. The observed effects on the experimental analysis were supported by a corresponding synthetic analysis based on EDGE2D-EIRENE simulations.

Balmer emission↗

Density measurements for the National Ignition Facility (NIF) opacity platform

The Opacity Platform on the National Ignition Facility (NIF) has been developed to measure opacities at varying densities and temperatures relevant to the solar interior and thermal cooling rates in white dwarf stars. The typical temperatures reached at NIF range between 150 and 210 eV, which allow these measurements to be performed experimentally. The captured opacities are crucial to validating radiation-hydrodynamic models that are used in astrophysics. The NIF opacity platform has a unique new capability that allows in situ measurement of the sample expansion. The sample expansion data are used to better understand the plasma conditions in our experiments by inferring the sample density throughout the duration of the laser drive. Here, we present the details of the density measurement technique, data analysis, and recent results for Fe and MgO.

47 OTHER INSTRUMENTATION↗

2nd and 3rd order spectral energy corrections with penumbral de-blurring methodology for opacity platform used on the National Ignition Facility

The Opacity Spectrometer (OpSpec) used in the National Ignition Facility’s opacity experiments measures x-ray spectra from 0.9 to 2.1 keV from the different experimental regions: the backlight source, emission source, and the absorption region with the transmission calculated from these regions. The OpSpec designs have gone through several iterations to help improve the signal-to-noise ratio, remove alternate crystal plane reflections, and improve spectral resolution, which helps to increase the validity of the opacity measurements. However, the source spans well outside the current working spectral range, and higher-order reflections are intrinsic to the crystal, which increases the overall signal seen in the data regions. The recorded data are the convolution of 1st order transmission, higher-order reflections, and the penumbra blurring. In conclusion, this work represents the details for deconvolving the 2nd and 3rd order spectral energy corrections with a penumbral de-blurring to correct the relative measurement of x-ray intensity of different spectral energies and further analysis of datasets relevant to the opacity experiments.

47 OTHER INSTRUMENTATION↗

Medium-induced radiative kernel with the Improved Opacity Expansion

We calculate the fully differential medium-induced radiative spectrum at next-to-leading order (NLO) accuracy within the Improved Opacity Expansion (IOE) framework. This scheme allows us to gain analytical control of the radiative spectrum at low and high gluon frequencies simultaneously. The high frequency regime can be obtained in the standard opacity expansion framework in which the resulting power series diverges at the characteristic frequency ω c ~ q^L 2 . In the IOE, all orders in opacity are resumed systematically below ωc yielding an asymptotic series controlled by logarithmically suppressed remainders down to the thermal scale T « ω c , while matching the opacity expansion at high frequency. Furthermore, we demonstrate that the IOE at NLO accuracy reproduces the characteristic Coulomb tail of the single hard scattering contribution as well as the Gaussian distribution resulting from multiple soft momentum exchanges. Finally, we compare our analytic scheme with a recent numerical solution, that includes a full resummation of multiple scatterings, for LHC-inspired medium parameters. Furthermore, we find a very good agreement both at low and high frequencies showcasing the performance of the IOE which provides for the first time accurate analytic formulas for radiative energy loss in the relevant perturbative kinematic regimes for dense media.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Background measurement methods for opacity experiments conducted at the Z facility

Laboratory experiments typically test opacity models by measuring spectrally resolved transmission of a sample using bright backlight radiation. A potential problem is that any unaccounted background signal contaminating the spectrum will artificially reduce the inferred opacity. Methods developed to measure background signals in opacity experiments at the Sandia Z facility are discussed. Preliminary measurements indicate that backgrounds are 9%–11% of the backlight signal at wavelengths less than 10 Å. Background is thus a relatively modest correction for all Z opacity data published to date. Future work will determine how important background is at longer wavelengths.

47 OTHER INSTRUMENTATION↗

Smokeless Chimney using Smoke Opacity as a Combustion Control Parameter (CRADA Final Report)

If operated poorly, wood burning heaters can produce large amounts of particulate matter (PM). Although several instruments are available to monitor PM, most require dilution air and are unable to sample directly from a flue due to the high PM concentrations and temperatures. Opacity sensors can measure color, opacity and smoke density from wood heater stacks. They operate by transmitting a light beam through the emission source and measuring the amount of light intensity lost (opacity) and light not reflected (color). Although opacity sensors are used in several areas, none have been thoroughly evaluated or optimized for measuring smoke from wood heaters.

47 OTHER INSTRUMENTATION↗

Cosmic Reionization on Computers: Statistical Properties of the Distributions of Mean Opacities

Quasar absorption lines provide a unique window to the relationship between galaxies and the intergalactic medium during the Epoch of Reionization. In particular, high redshift quasars enable measurements of the neutral hydrogen content of the universe. However, the limited sample size of observed quasar spectra, particularly at the highest redshifts, hampers our ability to fully characterize the intergalactic medium during this epoch from observations alone. In this work, we characterize the distributions of mean opacities of the intergalactic medium in simulations from the Cosmic Reionization on Computers (CROC) project. We find that the distribution of mean opacities along sightlines follows a non-trivial distribution that cannot be easily approximated by a known distribution. When comparing the cumulative distribution function of mean opacities measurements in subsamples of sample sizes similar to observational measurements from the literature, we find consistency between CROC and observations at redshifts $z\lesssim 5.7$. However, at higher redshifts ($z\gtrsim5.7$), the cumulative distribution function of mean opacities from CROC is notably narrower than those from observed quasar sightlines implying that observations probe a systematically more opaque intergalactic medium at higher redshifts than the intergalactic medium in CROC boxes at these same redshifts. This is consistent with previous analyses that indicate that the universe is reionized too early in CROC simulations.

79 ASTRONOMY AND ASTROPHYSICS↗

A superconfiguration calculation of opacity with consistent bound and continuum electron treatments using green’s functions

One of the challenges in calculating the opacity of dense plasmas is the difficulty in consistently modeling electrons bound to nuclei and those that exist within the continuum of free states in electronic structure models. We address this issue by adapting the green's function approach, originally developed for use in average atom calculations, to the determination of superconfiguration (SC) electronic structure. The spectra created using these SCs indicate that a consistent treatment of continuum electronic structure is important for phenomena involving electrons near ionization thresholds, such as the pressure ionization of bound states and the opacity due to transitions near bound-free edges. Though important for dense plasmas, the detailed incorporation of continuum electrons into structure calculations does not have significant impact on the recent discrepancies between the predicted and measured opacity of hot, dense iron (Bailey et al 2015 Nature517 56). Here we find that the inclusion of plasma effects through an ion-sphere model along with our treatment of continuum electronic states gives a description of pressure ionization in hot, dense aluminum that is in better agreement with experiment than methods that rely on perturbative descriptions of the plasma environment (Hoarty et al 2013 Phys. Rev. Lett.110 265003).

74 ATOMIC AND MOLECULAR PHYSICS↗

Application of New Los Alamos OPLIB Opacities in Solar Modeling Using the Mesa Code

The Sun provides the only local laboratory to test our understanding of stellar physics. The production, then, of valid dynamical models of the Sun is critical to how we think about other stars. Despite improvements in modeling methodologies and abundance measurements, solar models continue to reproduce errors in convection zone depth and surface helium abundance compared to helioseismic observations. Using the 1D stellar evolution code MESAstar, this work first evaluates the effect of changes to timestep resolution and mixing length theory on model outputs. A standard test case is then constructed with both GS98 and AGSS09 abundances using OP and OPAL opacities before implementing the new Los Alamos OPLIB opacities. It is shown that, when using GS98 abundances, OPLIB opacities improve agreement with helioseismic inference of the convection zone base radius, R czb , by 1.68-σ and 1.19-σ compared to OP and OPAL, respectively, while worsening agreement with the inferred envelope helium mass fraction, Y surf , by 0.63-σ and 0.98-σ for OP and OPAL.

14 SOLAR ENERGY↗

Transfer learning as a method to reproduce high-fidelity non-local thermodynamic equilibrium opacities in simulations

Simulations of high-energy density physics often need non-local thermodynamic equilibrium opacity data. These data, however, are expensive to produce at relatively low fidelity. It is even more so at high fidelity such that the opacity calculations can contribute 95 % of the total computation time. This proportion can even reach large proportions. Neural networks can be used to replace the standard calculations of low-fidelity data, and the neural networks can be trained to reproduce artificial, high-fidelity opacity spectra. In this work, it is demonstrated that a novel neural network architecture trained to reproduce high-fidelity krypton spectra through transfer learning can be used in simulations. Further, it is demonstrated that this can be done while achieving a relative per cent error of the peak radiative temperature of the hohlraum of approximately 1 % to 4 % while achieving a 19.4 $\times$ speed up.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Testing the optical components for the National Ignition Facility time-resolved soft x-ray opacity spectrometer (OpSpecTR)

Opacity measurements are being carried out at the Z-facility at Sandia National Laboratories and at the National Ignition Facility (NIF) at Lawrence Livermore National Laboratory. The current soft x-ray Opacity Spectrometer (OpSpec) used on the NIF uses two elliptically bent crystals in time-integrated mode on either an image plate or a film. Plans are under way to expand these opacity measurements into a mode of time-resolved detection, called OpSpecTR. Previously, considerations for the available hCMOS detector size and photometrics led to a crystal geometry redesign and the use of a grazing angle x-ray mirror. The mirror acts as a low-pass x-ray energy filter, reducing the contribution of higher energy x rays. The first tests of the mirror and the crystal for OpSpecTR are presented here. The size of the mirror reflection and the reflectivity is tested using a Manson x-ray source. The mirror coupled with the new elliptical crystal shape demonstrates OpSpecTR’s spectral coverage. Finally, the results from the x-ray optics performance testing are shown along with the intended design.

47 OTHER INSTRUMENTATION↗