Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “online monitoring system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Fast spark-detection system for GEM detectors

The sPHENIX experiment is currently under commissioning at the Relativistic Heavy Ion Collider (RHIC) at Brookhaven National Lab (BNL). The Time Projection Chamber (TPC) serves as a tracking detector for the experiment. The sPHENIX TPC uses a stack of four Gas Electron Multipliers (GEMs) as a gain stage in a reduced ion back-flow configuration. To mitigate the damaging effects of sparks in the GEMs, an online spark monitoring system was created. Once the system detects a spark in a GEM stack, the voltages across the GEMs in that stack can be lowered to prevent further sparking without affecting the gain and efficiency of the other modules. Spark signals are coupled out of the GEM stack by a pick-off capacitor attached to the bottom of the bottom GEM. Custom PCBs convert the oscillatory spark signal into a mono-polar pulse that is then digitized. The software then saves the waveform in a server and uses experimentally derived thresholds to determine how to react. As a result, the system has so far proven to be effective at improving the stability of the TPC and preventing damaging events while collecting cosmic ray data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sparge Sampling of Molten Salts for Online Monitoring via Laser-Induced Breakdown Spectroscopy

A method was developed to sample molten salts by sparging to generate and transport aerosols to an isolated instrument for compositional analysis by laser-induced breakdown spectroscopy (LIBS). Real-time monitoring of molten salt composition is critical to developing molten salt nuclear reactors, which offer enhanced safety and efficiency. In this article, the sparge sampling method is described and compared with sampling using a Collison nebulizer. The size distribution and transport of aerosols produced from molten eutectic NaNO 3 –KNO 3 salt were compared for multiple gas flow rates (75–1200 mL min –1 ) and transport distances (0.68–2.61 m). Both methods produced aerosols ranging from 0.5 to 5.0 μm determined using a cascade impactor. Aerosols were effectively transported without pre- or trace-heating of gas lines, but transport efficiency was reduced by the formation of agglomerates. Sparge sampling was found to use less sample and less gas than a Collison nebulizer while producing a more concentrated aerosol stream (up to 5 μg L –1 ). The effects of laser energy and delay time on the signal quality of LIBS measurements of these aerosols were also studied. High energy and short delay times were found to enhance signal and repeatability, whereas signal-to-background and signal-to-noise ratios were highest at low energy and longer delay times. The capabilities of this system for online monitoring of molten salts were demonstrated with calibrations for Sr and Li with relative standard deviations of 2.6% and 1.5% and limits of detection of 380 and 180 μg g –1 , respectively.

Aerosols↗

Development and Demonstration of a Prototype Molten Salt Sampling System

Molten salt reactors (MSRs) offer potential operability and safety advantages when compared to commercial light water reactors (LWRs). However, operating experience with MSRs is sparse in comparison to what exists for LWRs. Further, the chemical and isotopic composition of the fuel and/or coolant salt is dynamic and difficult to characterize continuously, posing potential safety, operability, and safeguards unknowns that need to be addressed. A molten salt sampling system (MSSS) is regarded as a necessary subsystem within first generation MSRs used to obtain samples of salt for chemical and isotopic analysis in support of the need to monitor and control salt composition during operation. The MSSS is being developed using the Safety-in-Design (SiD) methodology, which incorporates incremental integration of safety analysis into the design process. The MSSS conceptual design emerging from the application of the early stages of the SiD methodology consists of a sample collection system and its housing, a freeze port, and inert gas control and delivery systems. This article describes the prototypes developed to test the functions of these MSSS subsystems, presents the results of testing in both dry and molten salt environments (including reliability data collection performed in accordance with the principles of SiD and the development of a semiquantitative fault tree model), and summarizes the opportunities for future design and testing enhancements based on the results of prototype testing.

molten salt reactor↗

The CMS Barrel Calorimeter Processor demonstrator (BCPv1) board evaluation

For the CERN LHC phase 2, the barrel region of the CMS electromagnetic (ECAL EB) and hadronic calorimeters (HCAL HB) require new back-end electronics for their readout. To this purpose, a first version of the ATCA-based blade, the Barrel Calorimeter Processor (BCPv1), has been developed. The performance of the optical links as well as clock distribution are also presented here. Here, the BCPv1 has been tested together with front-end and trigger boards, as well as with the new DAQ and TCDS Hub (DTH) [1], to demonstrate that the BCPv1 meets the required specifications.

47 OTHER INSTRUMENTATION↗

EPICS for small-scale laboratories with Python soft IOCs

While the Experimental Physics and Industrial Control System (EPICS) is widely used at large laboratories for slow controls and instrumentation, the deployment of a full EPICS installation can be difficult, with a steep learning curve to new users. Taking advantage of the pythonSoftIOC module, we developed an EPICS slow controls implementation for Jefferson Lab's Hall B cryotarget written entirely in Python and based on software IOCs that communicate with instruments over Ethernet. Here, this system ran successfully, interfacing with Jefferson Lab's full EPICS network, and we offer it as an example of the capabilities of pythonSoftIOC to build lightweight, yet robust and flexible instrumentation platforms that would be easily adapted for use at a small-scale laboratory. University groups can use these examples to build complete slow controls systems, from device communication to data archiving and display, using open-source, mature EPICS tools and student-friendly Python as an alternative to expensive and proprietary systems such as LabVIEW.

Computing↗

Checking Flight Rules with TraceContract: Application of a Scala DSL for Trace Analysis

Typically during the design and development of a NASA space mission, rules and constraints are identified to help reduce reasons for failure during operations. These flight rules are usually captured in a set of indexed tables, containing rule descriptions, rationales for the rules, and other information. Flight rules can be part of manual operations procedures carried out by humans. However, they can also be automated, and either implemented as on-board monitors, or as ground based monitors that are part of a ground data system. In the case of automated flight rules, one considerable expense to be addressed for any mission is the extensive process by which system engineers express flight rules in prose, software developers translate these requirements into code, and then both experts verify that the resulting application is correct. This paper explores the potential benefits of using an internal Scala DSL for general trace analysis, named TRACECONTRACT, to write executable specifications of flight rules. TRACECONTRACT can generally be applied to analysis of for example log files or for monitoring executing systems online.

temporal logic↗

A Web Service and Android Application for the Distribution of Rainfall Estimates and Earth Observation Data

The full potential of Satellite Rainfall Estimates (SRE) can only be realized if timely access to the datasets is possible. Existing data distribution web portals are often focused on global products and offer limited customization options, especially for the purpose of routine regional monitoring. Furthermore, most online systems are designed to meet the needs of desktop users, limiting the compatibility with mobile devices. In response to the growing demand for SRE and to address the current limitations of available web portals a project was devised to create a set of freely available applications and services, available at a common portal that can: (1) simplify cross-platform access to Tropical Rainfall Measuring Mission Online Visualization and Analysis System (TOVAS) data (including from Android mobile devices), (2) provide customized and continuous monitoring of SRE in response to user demands and (3) combine data from different online data distribution services, including rainfall estimates, river gauge measurements or imagery from Earth Observation missions at a single portal, known as the Tropical Rainfall Measuring Mission (TRMM) Explorer. The TRMM Explorer project suite includes a Python-based web service and Android applications capable of providing SRE and ancillary data in different intuitive formats with the focus on regional and continuous analysis. The outputs include dynamic plots, tables and data files that can also be used to feed downstream applications and services. A case study in Southern Angola is used to describe the potential of the TRMM Explorer for SRE distribution and analysis in the context of ungauged watersheds. The development of a collection of data distribution instances helped to validate the concept and identify the limitations of the program, in a real context and based on user feedback. The TRMM Explorer can successfully supplement existing web portals distributing SRE and provide a cost-efficient resource to small and medium-sized organizations with specific SRE monitoring needs, namely in developing and transition countries.

precipitation↗

Raman Spectroscopic In Situ Monitoring of Highly Turbid Media

The ability to run chemical processing more efficiently and cost effectively is a need that spans critical materials recovery and legacy nuclear waste cleanup. Sensors integrated to provide online monitoring are essential to addressing this need by providing near-real time feedback on process conditions, which can improve efficiency, aid in decision making, and reduce the need for grab sample measurements. Optical spectroscopy is well-suited for providing online chemical composition information and has been widely applied in varied chemical systems. However, applications in turbid matrices continue to represent substantial challenges to sensor performance, where absorption or scattering of excitation light can cause significant signal interference. Here, in this study, close-focus Raman probes are investigated for use in turbid media as a way to overcome the signal loss from the scattering of the Raman excitation source. This, paired with advanced data science techniques, allowed for the development of chemometric models for the accurate quantification of several analytes of interest (NO 3 – , NO 2 – , and PO 4 3– ) in highly turbid solutions with solids loadings of up to 20 wt %. This work focuses on offline sample measurement and characterization as an initial step toward the development of online monitoring capabilities. Chemical systems of interest were focused on nuclear waste at the Hanford Site, which represents highly complex matrices that could realize significant processing benefits through the integration of online monitoring.

Felmy, Heather M. [Pacific Northwest National Labo↗

Online monitoring of lanthanide species with combined spectroscopy in flowing aqueous aerosol systems

Combined spectroscopic analysis through absorption and laser-induced breakdown spectroscopy (LIBS) was used to monitor Nd and Pr concentrations in a flowing aqueous system. A unique, online sampling approach was employed that allowed for an approximately closed analysis loop of liquids from a reservoir. Absorption spectroscopy was performed with an optical flow cell, and LIBS was performed on an aerosol stream. Multivariate calibrations based on combined absorption and LIBS signals were built for Nd and Pr and then used to monitor concentrations in mixed solutions in a series of spiking tests. In these tests, the concentrations of Nd and Pr in solution were intermittently changed while spectroscopic signals were monitored in real-time. The combined spectroscopic signals and multivariate models were successful in monitoring changing concentrations of lanthanide species with high accuracy and minimal latency. Root-mean squared error of predictions were 0.015 mol L −1 and 0.019 mol L −1 for Nd and Pr respectively, and these lanthanides were able to be monitored to an accuracy of < 0.2 wt%. This work demonstrates both the capabilities of a sampling system for online analysis of liquids and the capabilities of multimodal spectroscopic characterization for real-time, continuous tracking of species in potentially hazardous liquid systems.

absorbance spectroscopy↗

Investigation of a U(IV)/U(III) Thermodynamic Reference Electrode for High-Temperature Molten Fluoride Salts

While thermodynamic reference electrodes with known and stable potentials are common in traditional aqueous systems, the high temperature and corrosive environment of a molten fluoride salt makes achieving long term stability with a thermodynamic reference electrode challenging, especially at temperatures of 600°C or higher. In this work, a thermodynamic reference electrode consisting of U(IV)/U(III) in a boron nitride compartment was evaluated for use in FLiBe at temperatures ≥ 600°C. FLiBe used in the study was purified by AlphaTech's proprietary process and characterized by ICP-MS and square wave voltammetry. The free oxide concentration was <2 ppm. Using the purified FLiBe, the U(IV)/U(III) thermodynamic reference electrode was shown to provide a stable, well-defined, and reproducible potential for more than 600+ hours of use in different tests. Moreover, the thermodynamic reference electrode showed a consistent potential with no signs of failure, even after being cooled between tests and then reheated for reuse. Thus, the U(IV)/U(III) reference electrode is suitable for use in rigorous electrochemical studies in molten fluoride salts. As a result, it may be useful as a common standard, facilitating the advancement of nuclear applications such as isotope separation or online monitoring of reactor systems through improved certainty in the measurement of thermodynamic potentials.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Study program of NASA/GSFC weld quality monitor system

The Weld Quality Monitor has provided online control through the application of linear transducers. The electronic systems must be upgraded to increase confidence level required in production. The Weld Quality Monitor has been used with a recent model solid state power supply to evaluate ability to differentiate between sound and defective weld joints. The Weld Quality Monitor has been evaluated on Dumet and Kovar to interconnect materials Nickel and Alloy 180 in weld joints used on microelectronic module fabrication. Distinct separation was achieved between low strength welds and sound welds by the Quality Monitor. Evaluation performed indicates a drift level at less than 2 percent on a series of 50 consecutive welds. Operation under shop conditions identified need for controlled electrode impact. This was achieved with pneumatic actuation.

Hutchinson, W. R.↗

Feasibility of Lead Fast Reactor Heat Exchanger Tube Online Monitoring

Within virtually all reactor systems with heat exchangers, the thinnest barriers between primary and secondary fluids are the heat exchanger tubes. Consistent with light water reactor experience, the advanced reactor heat exchangers are the most susceptible regions for corrosion and leakage (NRC, 2019). Moreover, traditional inspections and repairs using robotics will be expensive or impractical. On-line structural health corrosion monitoring (OLSHM) is therefore desirable to detect tube degradation prior to leaks that may allow mixing of heat exchanger fluids. Rhetorically many molten salt reactor (MSR) designers plan for on-line monitoring of critical reactor components including heat exchangers but there are no proven OLSHM sensors or systems for MSR heat exchangers. Guided wave ultrasound from the tube-end or ID using conventional low-temperature piezoelectric sensors has been shown to be sensitive to pits and cracks less than 50% through-wall in long pipes and tubes (Narayanan M.M., 2019) . Mode and frequency selection are important for practical sensor design decisions and ultimate performance. The L-0 wave-mode is easily excited by L-mode transducers but they have surface normal wave motion that will be sensitive to and more attenuative because of fluid interaction with the tube surface (Rose J.L., 1994). Shear Horizontal (SH) wave modes have material motion parallel to the tube surface therefore are virtually unaffected by fluid interaction. For SH-0 to be nondispersive in steel, the frequency-thickness product (MHz-mm) must be less than approximately 1.5. SH mode transducers must be coupled by a material that can support shear stress; a thin layer of honey works well for temporary sensors and an adhesive or a brazed metallurgical bond for permanent sensors. If sensors are incorporated into the fabrication process, the same kinds of SH-0 waves can be generated from the stagnant flow area of the tube OD without compromising the heat-exchange tube function. Piezoelectric materials are also available that can withstand harsh temperatures of molten salt heat exchangers (Stevenson T., 2015) (Machura et al., 2008). Though they may not have as high-performance characteristics, their performance only needs to be good enough to detect flaws of interest. This project attempts to demonstrate feasibility to develop a sensor that can be sensitive to flaws of interest and perform long-term monitoring of a molten salt reactor heat exchanger. Benefits to the advanced reactor system include: • Minimizing the expense of a reactor shut down for periodic inspection—only shutdown for cause. • Reduce risk of unexpected tube rupture by detecting flaws before they grow to through-wall leaks. • Cost reduction by minimizing need to design for manual/robotic inspectability. Transducer design, characterization of the beam profile, wedges vs. direct application of piezoelectric sensors, and ultrasonic pulse-echo responses from a representative heat exchange tube with fabricated flaw types are discussed.

On-Line Tube Monitor, Guided Wave Ultrasound, SH-0↗

Anomaly Detection Based on Machine Learning for the CMS Electromagnetic Calorimeter Online Data Quality Monitoring

Using a semi-supervised machine learning approach we present a real-time anomaly detection system based on an autoencoder used for online data quality monitoring of the CMS electromagnetic calorimeter operating at the CERN LHC. We introduce a novel method that maximizes the anomaly detection performance making use of the time-dependence of anomalies and the spatial variations in the detector response. The autoencoder-based system efficiently detects anomalies in real time and maintains a very low false discovery rate. We validate the performance of this novel system with anomalies from LHC collision data taken in 2018 and 2022. In addition, results are presented after deploying the autoencoder-based system in the CMS online Data Quality Monitoring workflow at the beginning of LHC Run 3 resulting in the system to detect issues that were missed by the existing system.

Harilal, Abhirami [Carnegie Mellon University, Pit↗

Nondestructive Evaluation (NDE) of Cable Anomalies using Frequency Domain Reflectometry (FDR) and Spread Spectrum Time Domain Reflectometry (SSTDR)

This report presents a comparative assessment of the performance of frequency domain reflectometry (FDR) and spread spectrum time domain reflectometry (SSTDR) in detecting a wide range of electrical cable anomalies. All tests and results reported herein were performed at the PNNL Accelerated and Real-Time Environmental Nodal Assessment (ARENA) cable and motor test bed. The primary objective of this work was to evaluate the effectiveness of SSTDR, a fledgling cable monitoring technique that shows promise for application in online monitoring of energized cable systems, against FDR, an offline technique widely employed in the nuclear power plant (NPP) industry. FDR tests are becoming more widely used in nuclear power plant cable aging management and test programs – particularly for low voltage cables. FDR capabilities for these kinds of tests have been reported by PNNL and others. The FDR test is performed on de-energized cables by connecting the FDR instrument to two of the cable conductors, or one conductor and the shield. A broad band low voltage (< 5 V) chirp is introduced in the cable, and any reflected response is captured in the frequency domain. The captured reflection is then processed by performing an inverse Fourier transform to a time domain response which can then be converted to a distance response based on the cable velocity of propagation (VoP). SSTDR measurements are functionally similar to FDR measurements in that a broad-band voltage signal composed of a square or sine wave modulated pseudo-random sequence of chips (< 5 volts), is injected onto one of the cable conductors. The injected signal will experience partial energy reflection and transmission at each impedance discontinuity along the transmission line. Any reflected response is detected by computing a cross-correlation between the reflected signals and a delayed copy of the incident SSTDR signal. the time delay for the reflected signal to experience the best matched correlation with the incident signal, indicates the travel time for the signal to reach a change in impedance. By knowing this time delay and velocity of propagation (VoP) of the signal, one can compute the physical distance. A big advantage that SSTDR measurements have over other methods is the ability to be connected to energized or live wires (currently up to 1kV) thereby enabling online monitoring of cables. SSTDR has been used successfully in several applications, e.g., aircraft, rail, and photovoltaic systems. In this work FDR and SSTDR cable assessment techniques were used to characterize a variety of cable anomalies and faults including: (1) Presence or absence of a motor; (2) Ground faults and short circuit faults; (3) Moist environments and water ingress faults; (4) Accelerated thermal aging. Both shielded and non-shielded cables were evaluated in this report. Offline measurements were made using FDR and online measurements were made by SSTDR for a range of test scenarios. Based on the results across all cable anomalies evaluated in this study, FDR displayed high sensitivity towards cable condition assessment, while SSTDR showed promise for future application in monitoring NPP cable systems. However, further developments are suggested to improve the resolution and sensitivity of SSTDR towards faults and anomalies in low voltage cables.rt presents a comparative

42 ENGINEERING↗

Hydra: Computer Vision for Online Data Quality Monitoring

Hydra is a system utilizing computer vision for near real-time data quality monitoring. Currently operational across all of Jefferson Lab’s experimental halls, it reduces the workload of shift takers by autonomously monitoring diagnostic plots during experiments. Hydra uses "off-the-shelf" supervised learning technologies and is supported by a comprehensive MySQL database. To simplify access, web apps have been developed to facilitate both labeling and monitoring of Hydra’s inferences. Hydra can connect with the alarm system and incorporates complete historical tracking, enabling it to identify issues that shift takers could miss. When issues are detected, a natural first question is: "Why does Hydra think there is a problem?" To answer, Hydra employs Gradient-weighted Class Activation Maps (GradCAM) to identify regions of the image that are important for the specific classification. This interpretive layer enhances transparency and trustworthiness, which is essential for integration with experiment workflows and operation. The Hydra system, results, and sociological considerations for deployment will be discussed.

Jeske, Torri↗

Partitioning of Radionuclides in Various Streams of the Mo-99 Purification Process

The Universal Neutron Irradiator (UNI) was designed to irradiate a small volume of uranium solution and to achieve high fission power without creating a large radionuclide (RN) inventory. The UNI system is equipped with a fully enclosed off-gas system with online hydrogen gas monitoring to prevent the production of an explosive atmosphere, as well as storage cylinders for capturing fission gases. It also includes a catalytic recombiner in the target capsule (to immediately recombine radiolytic hydrogen and oxygen gas in the system) and access ports for sampling the target solution and capsule headspace. In UNI Phase I experiments, 50 mL of uranyl sulfate solution was irradiated at 0.3–0.5 W/mL fission power using a tantalum target assembly to produce photoneutrons via irradiation with an electron beam. The purposes of the Phase I experiments were to test the efficacy of adding 200 ppm Fe 2+ to the target solution to prevent uranyl peroxide precipitation under representative irradiation conditions, and to monitor iodine speciation in the irradiated uranyl sulfate solution. The focus of the UNI Phase II experiments was to use an irradiated uranyl sulfate solution containing a mixture of fission products and monitor their distribution in various streams during the primary recovery column (titania-based column) that separates Mo-99 from uranium. Irradiations were designed to create sufficient activity for tracking their distribution in various processing streams using a combination of gamma counting and inductively coupled plasma mass spectrometry (ICP-MS) analyses. Obtained data will be used to better understand the composition of waste streams, accumulation of RN on the titania column, and identify what RNs accumulate in the uranyl sulfate solution. Furthermore, this knowledge will allow us to determine waste classifications for various streams produced during the Mo-99 purification process and develop an appropriate waste clean-up strategy.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗