Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “nuclear pulse processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

A Simple Criterion to Estimate Performance of Pulse Jet Mixed Vessels

Pulse jet mixed process vessels comprise a key element of the U.S. Department of Energy’s strategy to process millions of gallons of legacy nuclear waste slurries. Slurry suctioned into a pulse jet mixer (PJM) tube at the end of one pulse is pneumatically driven from the PJM toward the bottom of the vessel at the beginning of the next pulse, forming a jet. The jet front traverses the distance from nozzle outlet to the bottom of the vessel and spreads out radially. Varying numbers of PJMs are typically arranged in a ring configuration within the vessel at a selected radius and operated concurrently. Centrally directed radial flows from neighboring jets collide to create a central upwell that elevates the solids in the center of the vessel when the PJM tubes expel their contents. An essential goal of PJM operation is to elevate solids to the liquid surface to minimize stratification. Solids stratification may adversely affect throughput of the waste processing plant. Unacceptably high slurry densities at the base of the vessel may plug the pipeline through which the slurry exits the vessel. Additionally, chemical reactions required for processing may not achieve complete conversion. To avoid these conditions, a means of predicting the elevation to which the solids rise in the central upwell that can be used during vessel design remains essential. In this paper we present a simple criterion to evaluate the extent of solids elevation achieved by a turbulent upwell jet. The criterion asserts that at any location in the central upwell the local velocity must be in excess of a cutoff velocity to remain turbulent. We find that local velocities in excess of 0.6 m/s are necessary for turbulent jet flow through both Newtonian and yield stress slurries. By coupling this criterion with the free jet velocity equation relating the local velocity to elevation in the central upwell, we estimate the elevation at which turbulence fails, and consequently the elevation at which the upwell fails to further lift the slurry. Comparing this elevation to the vessel fill level predicts whether the jet flow will achieve the full vertical extent of the vessel at the center. This simple local-velocity criterion determines a minimum PJM nozzle velocity at which the full vertical extent of the central upwell in PJM vessels will be turbulent. The criterion determines a minimum because flow in regions peripheral to the central upwelling jet may not be turbulent, even when the center of the vessel in the upwell is turbulent, if the jet pulse duration is too short. The local-velocity criterion ensures only that there is sufficient wherewithal for the turbulent jet flow to drive solids to the surface in the center of the vessel in the central upwell.

mixing↗

Measuring radiation damage dynamics by pulsed ion beam irradiation. 2015 Annual Progress Report for DOE/NE/NEET

The major goal of this project is to develop and demonstrate a novel experimental approach to access the dynamic regime of radiation damage formation processes in nuclear materials. In particular, the project exploits a pulsed-ion-beam method in order to gain insight into defect interaction dynamics by measuring effective defect interaction time constants and defect diffusion lengths. For Year 2, this project had the following two major milestones: (i) measurement of the temperature dependence of defect dynamics in SiC and (ii) the evaluation of the robustness of the pulsed beam method from studies of the defect generation rate. As we describe below, both of these milestones have been met.

36 MATERIALS SCIENCE↗

Electronics Upgrades to the Green is Clean Phoswich Detector Systems and Programmatic Implementation at LANL - Phase II Completion - 18403

Los Alamos National Laboratory (LANL) radiological facilities produce low-density room trash that, in many cases, is not contaminated with radioactivity. It has been estimated that 50 to 90% of low-density room trash is free of radioactive contamination and eligible for inclusion in LANL's Green is Clean (GIC) program. The GIC program is a verification program for non-regulated waste from radiation controlled areas that has been actively segregated as nonradioactive through the use of the waste generator's acceptable knowledge. The GIC program has employed two large area Phoswich gamma ray detector systems (HERCULES and ZEUS) to verify that GIC candidate low-density waste contains no radioactivity above background. The large area (127 cm{sup 2}) Phoswich detectors consist of a thin NaI front crystal (3 mm thick) that is optically coupled to a thick CsI back crystal (50 mm thick). The scintillation properties of the two crystals are different enough to allow the system's electronic components to identify the origin of any pulse. The original systems utilize Nuclear Instrumentation Module (NIM) electronics to process the detector signals. The electronics currently in use by the systems are out of date and some components are no longer manufactured. In 2015, phase I upgrades to the GIC detector systems were completed. Phase I objectives included identifying more modern commercially available electronics that could replace the NIM electronics. A pulse shape discriminator (PSD) module, the Digital Gamma Finder (DGF) Pixie-4 made by XIA LLC, that fits in a compact National Instruments{sup TM} PXI chassis was identified to replace the majority of the original NIM bin electronics - a single Pixie-4 module replaces four NIM amplifiers and four NIM pulse shape analyzers (PSAs). Another phase I objective was to show that that new PSD could separate out the NaI and CsI detector signals in a manner equivalent to or better than the NIM electronics. Proof of concept was achieved in 2015 when a prototype upgrade system on ZEUS was built and tested and gating parameter settings were determined that successfully separated the NaI and CsI signals. Phase II required establishing a LabVIEW software interface with Pixie-4 electronics in lieu of the manufacturer provided Pixie-4 software called the Pixie Viewer. In addition, phase II included 1) final optimization of the gating parameters on the prototype Pixie-4 ZEUS system, 2) finalizing Requirements, Design and Test Plan documents, 3) LabVIEW software interface quality assurance (QA) testing, 4) setting up the HERCULES system with the Pixie-4 upgrade electronics, 5) check source and background calibration of both systems, 6) absolute efficiency determination on both systems and 7) procedure revisions and implementation of both systems into routine operations. In 2017 phase II was completed including the preparation of detailed Requirements, Design and Test Plan documents. The LabVIEW interface software that communicates and controls the Pixie-4 has been completed, merged with the preexisting LabVIEW operations software and fully tested. Gating parameter optimization, configuration of HERCULES with the Pixie-4 electronics, check source and background calibrations and absolute efficiency determinations have all been performed - quantitative results are presented in the full paper. For performance validation, comparison measurements of actual GIC bags on both the HERCULES system using the old NIM Bin electronics and the ZEUS system using the upgraded Pixie-4 electronics have been done and evaluated. Finally, procedure revisions and implementation of both systems into routine operations is currently in process and planned to be complete by the end of calendar year 2017. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Digital pulse deconvolution with adaptive shaping for real-time high-resolution high-throughput gamma spectroscopy

A high-resolution high-throughput real-time adaptive digital pulse processing system is developed for high count rate gamma-ray spectroscopy applications. The adaptive digital pulse processing algorithms are implemented on a reconfigurable FPGA and include a pulse deconvolver, adaptive shaping filter, timing filter, baseline restorer, and pile-up rejecter. Digital pulse deconvolution is implemented to reconstruct the original detector signal from the preamplifier signal, which reduces the resolution deterioration due to pulse pile-up. The deconvoluted signal is shaped with a trapezoid filter and the shaping parameter is selected adaptively based on the time separation between successive input pulses. Experimental measurements are performed with a 137Cs source under varying count-rate conditions and using germanium detectors equipped with resistive feedback and transistor reset preamplifiers (TRP). The results herein demonstrate that when using a TRP, adaptive digital signal processing allows handling 106 counts/s. In addition, the implementation of a deconvolution approach limits resolution deterioration for throughput rates that are 4 to 10 times better than achievable in typical digital and analog gamma-ray spectroscopy systems.

47 OTHER INSTRUMENTATION↗

Exploring Interatomic Coulombic Decay by Free Electron Lasers

To exploit the high intensity of laser radiation, we propose to select frequencies at which single-photon absorption is of too low energy and two or more photons are needed to produce states of an atom that can undergo interatomic Coulombic decay (ICD) with its neighbors. For Ne{sub 2} it is explicitly demonstrated that the proposed multiphoton absorption scheme is much more efficient than schemes used until now, which rely on single-photon absorption. Extensive calculations on Ne{sub 2} show how the low-energy ICD electrons and Ne{sup +} pairs are produced for different laser intensities and pulse durations. At higher intensities the production of Ne{sup +} pairs by successive ionization of the two atoms becomes competitive and the respective emitted electrons interfere with the ICD electrons. It is also shown that a measurement after a time delay can be used to determine the contribution of ICD even at high laser intensity.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Active Interrogation using Photofission Technique for Nuclear Materials Control and Accountability

Innovative systems with increased sensitivity and resolution are in great demand to detect diversion and to prevent misuse in support of nuclear materials management for the U.S. fuel cycle. Nuclear fission is the most important multiplicative process involved in non-destructive active interrogation. This process produces the most easily recognizable signature for nuclear materials. In addition to thermal or high-energy neutrons, high-energy gamma rays can also excite a nucleus and cause fission through a process known as photofission. Electron linear accelerators (linacs) are widely used as the interrogating photon sources for inspection methods involving photofission technique. After photofission reactions, prompt signals are much stronger than the delayed signals, but it is difficult to quantify them in practical measurements. Delayed signals are easily distinguishable from the interrogating radiation. Linac-based, advanced inspection techniques utilizing the delayed signals after photofission have been extensively studied for homeland security applications. Previous research also showed that a unique delayed gamma ray energy spectrum exists for each fissionable isotope. In this work, high-energy delayed γ-rays were demonstrated to be signatures for detection, identification, and quantification of special nuclear materials. Such γ-rays were measured in between linac pulses using independent data acquisition systems. A list-mode system was developed to measure low-energy delayed γ-rays after irradiation. Photofission product yields of 238 U and 239 Pu were determined based on the measured delayed γ-ray spectra. The differential yields of delayed γ-rays were also proven to be able to discriminate nuclear from non-nuclear materials. The measurement outcomes were compared with Monte Carlo simulation results. It was demonstrated that the current available codes have capabilities and limitations in the simulation of photofission process. A two-fold approach was used to address the high-rate challenge in used nuclear fuel assay based on photofission technique. First, a standard HPGe preamplifier was modified to improve its capabilities in high-rate pulsed photofission environment. Second, advanced pulse processing algorithms were shown to greatly improve throughput rate without large sacrifice in energy resolution at ultra-high input count rate. Two customized gamma spectroscopy systems were also developed in real-time on FPGAs. They were shown to have promising performance matching available commercial units.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Streaking at high energies with electrons and positrons

State-of-the-art attosecond metrology deals with the detection and characterization of photon pulses with typical energies up to the hundreds of eV and time resolution of several tens of attoseconds. Such short pulses are used for example to control the motion of electrons on the atomic scale or to measure inner-shell atomic dynamics. The next challenge of time-resolving the inner-nuclear dynamics, transient meson states and resonances requires photon pulses below attosecond duration and with energies exceeding the MeV scale. Here we discuss a detection scheme for time-resolving high-energy gamma ray pulses down to the zeptosecond timescale. The scheme is based on the concept of attosecond streak imaging, but instead of conversion of photons into electrons in a nonlinear medium, the high-energy process of electron-positron pair creation is utilized. These pairs are produced in vacuum through the collision of a test pulse to be characterized with an intense laser pulse, and they acquire additional energy and momentum depending on their phase in the streaking pulse at the moment of production. A coincidence measurement of the electron and positron momenta after the interaction provides information on the pair production phase within the streaking pulse. We examine the limitations imposed by quantum radiation reaction in multiphoton Compton scattering on this detection scheme, and discuss other necessary conditions to render the scheme feasible in the upcoming Extreme Light Infrastructure (ELI) laser facility.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Feasibility of Pulsed Current Technology for Removing Bulk Carbon from TRISO-based Fuels

The work described in this report has evaluated the technical feasibility of maturing the pulsed current technology and its full-scale application to processing TRISO used nuclear fuel. No insurmountable technological or safety barriers were identified to successfully maturing the technology to the fourth TRL, which was considered appropriate for a DOE-NE program. The authors recommend DOE-NE’s Nuclear Fuel Cycle and Supply Chain Office should pursue the technology on that basis. In the immediate future, the authors recommend DOE-NE’s Nuclear Fuel Cycle and Supply Chain Office should acquire non-radioactive surrogate and natural uranium TRISO compacts and pebbles as they become available from commercial vendors. These surrogates could then be used to mature the pulsed current technology.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Pulsed Thermal Tomography Nondestructive Examination of Additively Manufactured Reactor Materials and Components. Third Annual Progress Report

Additive manufacturing (AM) of high-strength corrosion resistance alloys for nuclear energy applications, such as stainless steel and Inconel, is currently based on laser powder bed fusion (LPBF) process. Some of the challenges with using LPBF method for nuclear manufacturing include the possibility of introducing pores into metallic structures. Probability of crack initiation at the pore depends on size, shape, and orientation of the defect. Pulsed Infrared Thermography Imaging (PIT) provides a capability for non-destructive evaluation (NDE) of sub-surface defects in arbitrary size structures. The PIT method is based on recording material surface temperature transients with infrared (IR) camera following thermal pulse delivered on material surface with flash light. The PIT method has advantages for NDE of actual AM structures because the method involves one-sided non-contact measurements and fast processing of large sample areas captured in one image. Following initial qualification of an AM component for deployment in a nuclear reactor, a PIT system can also be used for in-service nondestructive evaluation (NDE) applications. In this report, we describe recent progress in enhancing PIT capabilities in detecting microscopic subsurface defects in metals, and classifying shapes and orientation of pores in thermal images. For detection of microscopic defects in PIT imaging data, we have developed Spatial Temporal Denoised Thermal Source Separation (STDTSS) unsupervised machine learning (ML) image processing algorithm. We show that flat bottom hole (FBH) defects as small as 200µm in SS316 and IN718 specimens, can be detected with STDTSS algorithm. To the best of our knowledge, these are the smallest detected defects which are reported in literature. For classification of defects shapes, we have previously developed thermal tomography (TT) algorithm to obtain depth reconstructions of material defects from data cube of sequentially recorded surface temperatures. However, interpretation of TT images is non-trivial because of blurring with increasing depth. To address this challenge, we have developed a deep learning convolutional neural network (CNN) to classify size and orientation subsurface defects in simulated TT images.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Sensitivity study for s process nucleosynthesis in AGB stars

In this paper we present a large-scale sensitivity study of reaction rates in the main component of the s process. The aim of this study is to identify all rates, which have a global effect on the s process abundance distribution and the three most important rates for the production of each isotope. We have performed a sensitivity study on the radiative {sup 13}C-pocket and on the convective thermal pulse, sites of the s process in AGB stars. We identified 22 rates, which have the highest impact on the s-process abundances in AGB stars.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Radioisotope production using lasers: From basic science to applications

The discovery of chirped pulse amplification has led to great improvements in laser technology, enabling energetic laser beams to be compressed to pulse durations of tens of femtoseconds and focused to a few micrometers. Protons with energies of tens of MeV can be accelerated using, for instance, target normal sheath acceleration and focused on secondary targets. Under such conditions, nuclear reactions can occur, with the production of radioisotopes suitable for medical application. The use of high-repetition lasers to produce such isotopes is competitive with conventional methods mostly based on accelerators. In this paper, we study the production of 67Cu, 63Zn, 18F, and 11C, which are currently used in positron emission tomography and other applications. At the same time, we study the reactions 10B(p,α)7Be and 70Zn(p,4n)67Ga to put further constraints on the proton distributions at different angles, as well as the reaction 11B(p,α)8Be relevant for energy production. The experiment was performed at the 1 PW laser facility at Vega III in Salamanca, Spain. Angular distributions of radioisotopes in the forward (with respect to the laser direction) and backward directions were measured using a high purity germanium detector. Our results are in reasonable agreement with numerical estimates obtained following the approach of Kimura and Bonasera [Nucl. Instrum. Methods Phys. Res., Sect. A 637, 164–170 (2011)].

11C↗

Applying Hanford Tank Mixing Data to Define Pulse Jet Mixer Operation

Pulse jet mixed (PJM) process vessels are being developed for storing, blending, and chemical processing of nuclear waste slurries at the Waste Treatment and Immobilization Plant (WTP) to be built at Hanford, Washington. These waste slurries exhibit variable process feed characteristics including Newtonian to non-Newtonian rheologies over a range of solids loadings. Waste feed to the WTP from the Hanford Tank Farms will be accomplished via the Waste Feed Delivery (WFD) system which includes million-gallon underground storage double-shell tanks (DSTs) with dual-opposed jet mixer pumps. Experience using WFD type jet mixer pumps to mobilize actual Hanford waste in DSTs may be used to establish design threshold criteria of interest to pulse jet mixed process vessel operation. This paper describes a method to evaluate the pulse jet mixed vessel capability to process waste based on information obtained during mobilizing and suspending waste by the WFD system jet mixer pumps in a DST. Calculations of jet velocity and wall shear stress in a specific pulse jet mixed process vessel were performed using a commercial computational fluid dynamics (CFD) code. The CFD-modelled process vessel consists of a 4.9-m- (16-ft-) diameter tank with a 2:1 semi-elliptical head, a single, 10-cm (4-in.) downward facing 60-degree conical nozzle, and a 0.61-m (24-in.) inside diameter PJM. The PJM is located at 70% of the vessel radius with the nozzle stand-off-distance 14 cm (6 in.) above the vessel head. The CFD modeled fluid velocity and wall shear stress can be used to estimate vessel waste-processing performance by comparison to available actual WFD system process data. Test data from the operation of jet mixer pumps in the 23-m (75-ft) diameter DSTs have demonstrated mobilization, solid particles in a sediment matrix were moved from their initial location, and suspension, mobilized solid particles were moved to a higher elevation in the vessel than their initial location, of waste solids. Jet mixer pumps were used in Hanford waste tank 241-AZ-101, and at least 95% of the 0.46-m (18-in.) deep sediment, with a shear strength of 1,500 to 4,200 Pa, was mobilized. Solids with a median particle size of 43 μm, 90th percentile of 94μm, were suspended in tank 241-AZ-101 to at least 5.5 m (216 in.) above the vessel bottom. Analytical calculations for this jet mixer pump test were used to estimate the velocities and wall shear stress that mobilized and suspended the waste. These velocities and wall shear stresses provide design threshold criteria which are metrics for system performance that can be evaluated via testing. If the fluid motion in a specific pulse jet mixed process vessel meets or exceeds the fluid motion of the demonstrated performance in the WFD system, confidence is provided that that vessel will similarly mobilize and suspend those solids if they were within the WTP. The single PJM CFD-calculated jet velocity and wall shear stress compare favorably with the design threshold criterion estimated for the tank 241-AZ-101 process data. Therefore, for both mobilization and suspension, the performance data evaluated from the WFD system testing increases confidence that the performance of the pulse jet mixed process vessels will be sufficient to process that waste even if that waste is not fully characterized.

mixing' slurry↗

Microwave-Free Dynamic Nuclear Polarization via Sudden Thermal Jumps

Dynamic nuclear polarization (DNP) presently stands as the preferred strategy to enhance the sensitivity of nuclear magnetic resonance measurements, but its application relies on the use of high-frequency microwave to manipulate electron spins, an increasingly demanding task as the applied magnetic field grows. Here we investigate the dynamics of a system hosting a polarizing agent formed by two distinct paramagnetic centers near a level anticrossing. We theoretically show that nuclear spins polarize efficiently under a cyclic protocol that combines alternating thermal jumps and radio-frequency pulses connecting hybrid states with opposite nuclear and electronic spin alignment. Central to this process is the difference between the spin-lattice relaxation times of either electron spin species, transiently driving the electronic spin bath out of equilibrium after each thermal jump. Without the need for microwave excitation, this route to enhanced nuclear polarization may prove convenient, particularly if the polarizing agent is designed to feature electronic level anticrossings at high magnetic fields.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Method and apparatus for studying high-temperature properties of conductive materials in the interests of nuclear power engineering

Physical processes during a rapid (microsecond) heating of metals, carbon, and their compounds by a single pulse of electric current are discussed. Effects arising in such short-term heating near the melting point are noted: the electron emission and heat capacity anomalies and the possible occurrence of Frenkel pair (interstitial atom and vacancy). The problem of measuring the temperature using optical methods under pulse heating is considered, including the use of a specimen in the form of a blackbody model. The melting temperature of carbon (4800–4900 K) is measured at increased pulse pressure. The results of studying the properties of metals (by example of zirconium and hafnium) and of zirconium carbide at high temperatures are discussed. The schematics of the pulse setups and the instrumentation, as well as specimens for a pulse experiment, are presented.

36 MATERIALS SCIENCE↗

YALINA-booster subcritical assembly pulsed-neutron experiments : data processing and spatial corrections.

The YALINA-Booster experiments and analyses are part of the collaboration between Argonne National Laboratory of USA and the Joint Institute for Power & Nuclear Research - SOSNY of Belarus for studying the physics of accelerator driven systems for nuclear energy applications using low enriched uranium. The YALINA-Booster subcritical assembly is utilized for studying the kinetics of accelerator driven systems with its highly intensive D-T or D-D pulsed neutron source. In particular, the pulsed neutron methods are used to determine the reactivity of the subcritical system. This report examines the pulsed-neutron experiments performed in the YALINA-Booster facility with different configurations for the subcritical assembly. The 1141 configuration with 90% U-235 fuel and the 1185 configuration with 36% or 21% U-235 fuel are examined. The Sjoestrand area-ratio method is utilized to determine the reactivities of the different configurations. The linear regression method is applied to obtain the prompt neutron decay constants from the pulsed-neutron experimental data. The reactivity values obtained from the experimental data are shown to be dependent on the detector locations inside the subcritical assembly and the types of detector used for the measurements. In this report, Bell's spatial correction factors are calculated based on a Monte Carlo model to remove the detector dependences. The large differences between the reactivity values given by the detectors in the fast neutron zone of the YALINA-Booster are reduced after applying the spatial corrections. In addition, the estimated reactivity values after the spatial corrections are much less spatially dependent.

43 PARTICLE ACCELERATORS↗

Understanding the impact of nuclear-data covariances on various integral responses using adjustment

The EUCLID (Experiments Underpinned by Computational Learning for Improvements in Nuclear Data) project created a library of sensitivities for nine different integral responses with respect to nuclear data. These integral responses were obtained from measurements at LLNL (Lawrence Livermore National Laboratory) pulsed spheres, critical and sub-critical assemblies. At the same time, covariances for ENDF/B-VIII.0 were processed at LANL (Los Alamos National Laboratory). The combination of these data allow us to study the impact of nuclear-data covariances on various integral responses, either by forward-propagating covariances via sensitivities, or by using nuclear data, integral responses, and sensitivities for adjustment. Here, we will present: the impact of 1 H, 9 Be, 12 C, 27 Al, 56 Fe, 235,238 U, and 239,240 Pu ENDF/B-VIII.0 covariances on simulated bounds of the following integral responses: LLNL pulsed-spheres neutron-leakage spectra, the effective neutron multiplication factor, reaction rates, and reactivity coefficients of ICSBEP critical assemblies. Also, adjustment results with the same nuclear-data covariances and responses will be discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Residual waste detection in HLW tanks - 15701

This research uses commercial sonar technology to monitor residual waste in the U.S. Department of Energy's (DOE) Hanford Site high-level-waste staging tanks, with primary focus on the detection and imaging of the settled solids at specified areas of interest along the tank surface within a limited amount of time. High-level waste (HLW) is generated at the US-DOE Hanford Site as a by-product from the processing of nuclear materials. Waste is currently stored in 177 underground carbon-steel waste tanks. Pulse jet mixers (PJM) are often used to break loose and suspend the solids that have settled at the bottom of the tanks. A typical tank can have 6-8 pulse tubes. The Solid Liquid Interface Monitor (SLIM) must be capable of measuring dynamic movements in Region 1 zone between each PJM cycle. SLIM was originally developed to map the sludge/supernate interface within the U.S. DOE Hanford Site's HLW tanks. SLIM is a dual-axis mechanically rotating sonar and consists of an acoustic transducer, rotation motor with gearbox, tilt motor, position reference sensor, and pressure balancing mechanisms and its associated deployment platform. The sonar gathers a swath of data in the horizontal plane and rotates the transducer through a programmed angle around the vertical axis. Oil-filled device. No user serviceable parts. No semiconductors. Hard anodized aluminum and polyurethane delrin. May be deployed in areas of significant radioactivity. Kaolin will be used during mixing operations in order to simulate the physical properties of the expected slurry. In order to reduce the amount of time needed to image and object, all settings were decreased to their minimal state. The low resolution settings provide insufficient data for the manufacturer's 3D profiler to compile a visible point cloud and much less to allow the meshing algorithm to work properly. Several filtering algorithms have been applied to each scan in order to remove erroneous spikes and ghosting effects. Data has been collected for the mixing process of kaolin. This data consists of scans executed while the pump was active and inactive. The imaging algorithm has also been used with data derived from scans of 3% or less of kaolin. Future work: Mixing of kaolin within an experimental tank will be conducted in order to simulate the settling time of the HLW within the tank. The same filtering algorithms will be applied to each of these scans to evaluate the SLIM's efficiency to image solids at the bottom of a tank through increasing volume of kaolin.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗