Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “nuclear detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Development of High Gradient Laser Wakefield Accelerators Towards Nuclear Detection Applications at LBNL

Compact high-energy linacs are important to applications including monochromatic gamma sources for nuclear material security applications. Recent laser wakefield accelerator experiments at LBNL demonstrated narrow energy spread beams, now with energies of up to 1 GeV in 3 cm using a plasma channel at low density. This demonstrates the production of GeV beams from devices much smaller than conventional linacs, and confirms the anticipated scaling of laser driven accelerators to GeV energies. Stable performance at 0.5 GeV was demonstrated. Experiments and simulations are in progress to control injection of particles into the wake and hence to improve beam quality and stability. Using plasma density gradients to control injection, stable beams at 1 MeV over days of operation, and with an order of magnitude lower absolute momentum spread than previously observed, have been demonstrated. New experiments are post-accelerating the beams from controlled injection experiments to increase beam quality and stability. Thomson scattering from such beams is being developed to provide collimated multi-MeV monoenergetic gamma sources for security applications from compact devices. Such sources can reduce dose to target and increase accuracy for applications including photofission and nuclear resonance fluorescence.

43 PARTICLE ACCELERATORS↗

Nuclear Detection Figure Of Merit (NDFOM) Version 1.2 User's Guide

NDFOM is a detector database and detector evaluation system, accessible as a web service. It runs on the same server as the Patriot service, but uses port 8081. In this user's guide, we will use the example case that the patriot service is running on http://patriot.lanl.gov. Then the NDFOM service would be accessible at the URL http://patriot.lanl.gov:8081/ndfom. In addition to local server installations, common server locations are 1) a patriot server running on a virtual machine (use the virtual machine URL with :8081/ndfom), and 2) a patriot server running on a local machine (use http://localhost:8081/ndfom or http://127.0.0.1:8081/ndfom).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Vela Hotel Program: The AEC's Space-Based Nuclear Detection and Treaty Verification Program [Slides]

Early Interest in "Detection": "I would suggest that the best way to get reliable information in a short time would be to send from the States a man qualified to do the testing of the samples on the spot. This man should be officially a representative of the State Department, and his detecting devices, such as small portable Geiger Counters, could then go into Switzerland in the diplomatic pouch via air from Southern Italy. This man could then contact, through the Embassy, suitable people who could collect the water samples without arousing too much curiosity. A fishing trip in a boat would probably give the best disguise, as the fisherman could carry a water bottle in his lunch basket, and fill it after drinking the original contents. The water should be collected from the center of the river, to get the swiftest flowing water, so that the holdup could be minimized. In the lake, the water should be collected as near to the suspected site as possible, or as near to each of the inlet rivers as can be done. Speed in getting from the collection point to the counting room is of great importance, as you are, no doubt, aware." - Luis Alvarez to Major Furman, May 1944.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ammonium Fluoride Passivation of CdZnTeSe Sensors for Applications in Nuclear Detection and Medical Imaging

Cadmium zinc telluride selenide (Cd1−xZnxTe1−ySey or CZTS) is one of the emerging CdTe-based semiconductor materials for detecting X- and gamma-ray radiation at or near room temperature (i.e., without cryogenic cooling). Potential applications of CZTS sensors include medical imaging, X-ray detection, and gamma-ray spectroscopy. Chemical passivation of CZTS is needed to reduce the conductivity of Te-rich surfaces, which reduces the noise and improves the device performance. In this study, we focus on the effect of surface passivation of CZTS using a 10% aqueous solution of ammonium fluoride. The effects of the chemical treatment were studied on the leakage current, charge transport measured as the electron mobility-lifetime (µτ) product, and the spectral resolution measured as the full-width at half-maximum (FWHM) of specific peaks. After passivation, the leakage current increased and began to decrease towards pre-passivation levels. The energy resolutions were recorded for eight applied voltages between −35 V and −200 V. The results showed an average of 25% improvement in the detector’s energy resolution for the 59.6 keV gamma peak of Am-241. The electron µτ product was unchanged at 2 × 10−3 cm2/V. These results show that ammonium fluoride is effective for chemical passivation of CZTS detectors.

36 MATERIALS SCIENCE↗

Growth of InI single crystals for nuclear detection applications

In this paper, we have developed a procedure to purify, synthesize and grow InI single crystals using the Bridgman technique. The commercial product of InI from Alfa Aesar (99.998% InI or 4 N) was zone refined by 50 passes of a zone-heater at 420 °C, traveling at 2 cm/h (the melting point of InI is 360 °C). InI was also synthesized using high purity In and I 2 by vapor transport technique. The grown InI single crystal showed a clear band edge excitonic emission around 2.02 eV at 6 K using photoluminescence measurement. The resistivities of InI detectors were found to be ~2×10 9 and 1×10 8 Ω cm for zone refined and vapor synthesized starting materials, respectively. Finally, the InI detector formed by Pd–Pd contact showed clear peak of alpha particle detection at room temperature using 241 Am source.

36 MATERIALS SCIENCE↗

Measurement of neutrino and antineutrino neutral-current quasielasticlike interactions on oxygen by detecting nuclear deexcitation γ rays

Neutrino- and antineutrino-oxygen neutral-current quasielasticlike interactions are measured at Super-Kamiokande using nuclear deexcitation γ rays to identify signal-like interactions in data from a 14.94 ( 16.35 ) × 10 20 protons-on-target exposure of the T2K neutrino (antineutrino) beam. The measured flux-averaged cross sections on oxygen nuclei are < σ ν - NCQE > = 1.70 ± 0.17 ( stat . ) - 0.38 + 0.51 ( syst . ) × 10 - 38 cm 2 / oxygen with a flux-averaged energy of 0.82 GeV and < σ ν ¯ - NCQE > = 0.98 ± 0.16 ( stat . ) - 0.19 + 0.26 ( syst . ) × 10 - 38 cm 2 / oxygen with a flux-averaged energy of 0.68 GeV, for neutrinos and antineutrinos, respectively. These results are the most precise to date, and the antineutrino result is the first cross section measurement of this channel. They are compared with various theoretical predictions. The impact on evaluation of backgrounds to searches for supernova relic neutrinos at present and future water Cherenkov detectors is also discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Detecting nuclear mass distribution in isobar collisions via charmonium

Abstract The collective properties of final state hadrons produced in the high statistics $$_{44}^{96}$$ 44 96 Ru + $$_{44}^{96}$$ 44 96 Ru and $$_{40}^{96}$$ 40 96 Zr + $$_{40}^{96}$$ 40 96 Zr collisions at $$\sqrt{s_\textrm{NN}} = 200~\textrm{GeV}$$ s NN = 200 GeV are found to be significantly different. Such differences were argued to be precise probes of the difference in nucleon distribution in the isobar nuclei. We investigate the $$J/\psi $$ J / ψ production in the isobar collision via a relativistic transport approach. By comparing the isobar systems according to equal centrality bin and equal multiplicity bin, we find that the yield ratio of $$J/\psi $$ J / ψ is sensitive to the differences in both the number of binary collisions and the medium evolution. Besides, the elliptic flow $$v_2$$ v 2 of $$J/\psi $$ J / ψ is qualitatively different from the light hadrons, and the ratio between Ru + Ru and Zr + Zr collisions is sensitive to the medium evolution. The charmonium production provides an independent probe to study the nucleon distribution in the isobar system.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

White paper : the fourth amendment : implications for radiological and nuclear detection.

The need to improve the radiation detection architecture has given rise to increased concern over the potential of equipment or procedures to violate the Fourth Amendment. Protecting the rights guaranteed by the Constitution is a foremost value of every government agency. However, protecting U.S. residents and assets from potentially catastrophic threats is also a crucial role of government. In the absence of clear precedent, the fear of potentially violating rights could lead to the rejection of effective and reasonable means that could reduce risks, possibly savings lives and assets. The goal of this document is not to apply case law to determine what the precedent may be if it exists, but rather provide a detailed outline that defines searches and seizures, identifies what precedent exists and what precedent doesn't exist, and explore what the existing (and non-existing) precedent means for the use of radiation detection used inside the nation's borders.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗