Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “normal measurement error”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

A control network of Triton

A control network for Triton has been computed using a bundle-type analytical triangulation program. The network contains 105 points that were measured on 57 Voyager-2 pictures. The adjustment contained 1010 observation equations and 382 normal equations and resulted in a standard measurement error of 13.36 microns. The coordinates of the control points, the camera orientation angles at the times when the pictures were taken, and Triton's mean radius were determined. A separate statistical analysis confirmed Triton's radius to be 1352.6 + or - 2.4 km. Attempts to tie the control network around the satellite were unsuccessful because discontinuities exist in high-resolution coverage between 66 deg and 289 deg longitude, north of 38 deg latitude, and south of 78 deg latitude.

Davies, Merton E.↗

Dynamic modeling of structures from measured complex modes

A technique is presented to use a set of identified complex modes together with an analytical mathematical model of a structure under test to compute improved mass, stiffness and damping matrices. A set of identified normal modes, computed from the measured complex modes, is used in the mass orthogonality equation to compute an improved mass matrix. This eliminates possible errors that may result from using approximated complex modes as normal modes. The improved mass matrix, the measured complex modes and the higher analytical modes are then used to compute the improved stiffness and damping matrices. The number of degrees-of-freedom of the improved model is limited to equal the number of elements in the measured modal vectors. A simulated experiment shows considerable improvements, in the system's analytical dynamic model, over the frequency range of the given measured modal information.

Ibrahim, s. R.↗

Dynamic Modeling of Structures from Measured Complex Modes

A technique is presented to use a set of identified complex modes together with an analytical mathematical model of a structure under test to compute improved mass, stiffness and damping matrices. A set of identified normal modes, computed from the measured complex modes, is used in the mass orthogonality equation to compute an improved mass matrix. This eliminates possible errors that may result from using approximated complex modes as normal modes. The improved mass matrix, the measured complex modes and the higher analytical modes are then used to compute the improved stiffness and damping matrices. The number of degrees-of-freedom of the improved model is limited to equal the number of elements in the measured modal vectors. A simulated experiment shows considerable improvements, in the system's analytical dynamic model, over the frequency range of the given measured modal information.

Ibrahim, S. R.↗

Performability modeling based on real data: A casestudy

Described is a measurement-based performability model based on error and resource usage data collected on a multiprocessor system. A method for identifying the model structure is introduced and the resulting model is validated against real data. Model development from the collection of raw data to the estimation of the expected reward is described. Both normal and error behavior of the system are characterized. The measured data show that the holding times in key operational and error states are not simple exponentials and that a semi-Markov process is necessary to model the system behavior. A reward function, based on the service rate and the error rate in each state, is then defined in order to estimate the performability of the system and to depict the cost of different types of errors.

Hsueh, M. C.↗

Performability modeling based on real data: A case study

Described is a measurement-based performability model based on error and resource usage data collected on a multiprocessor system. A method for identifying the model structure is introduced and the resulting model is validated against real data. Model development from the collection of raw data to the estimation of the expected reward is described. Both normal and error behavior of the system are characterized. The measured data show that the holding times in key operational and error states are not simple exponentials and that a semi-Markov process is necessary to model system behavior. A reward function, based on the service rate and the error rate in each state, is then defined in order to estimate the performability of the system and to depict the cost of apparent types of errors.

Hsueh, M. C.↗

An in-flight investigation of ground effect on a forward-swept wing airplane

A limited flight experiment was conducted to document the ground effect characteristics of the X-29A research aircraft. This vehicle has an aerodynamic platform which includes a forward-swept wing and close-coupled, variable incidence canard. The flight-test program obtained results for errors in the air data measurement and for incremental normal force and pitching moment caused by ground effect. Correlations with wind-tunnel and computational analyses were made. The results are discussed with respect to the dynamic nature of the flight measurements, similar data from other configurations, and pilot comments. The ground effect results are necessary to obtain an accurate interpretation of the vehicle's landing characteristics. The flight data can also be used in the development of many modern aircraft systems such as autoland and piloted simulation.

Curry, Robert E.↗

A Factorial Data Rate and Dwell Time Experiment in the National Transonic Facility

This report is an introductory tutorial on the application of formal experiment design methods to wind tunnel testing, for the benefit of aeronautical engineers with little formal experiment design training. It also describes the results of a Study to determine whether increases in the sample rate and dwell time of the National Transonic Facility data system Would result in significant changes in force and moment data. Increases in sample rate from 10 samples per second to 50 samples per second were examined, as were changes in dwell time from one second per data point to two seconds. These changes were examined for a representative aircraft model in a range of tunnel operating conditions defined by angles of attack from 0 deg to 3.8 degrees, total pressure from 15.0 psi to 24.1 psi, and Mach numbers from 0.52 to 0.82. No statistically significant effect was associated with the change in sample rate. The change in dwell time from one second to two seconds affected axial force measurements, and to a lesser degree normal force measurements. This dwell effect comprises a "rectification error" caused by incomplete cancellation of the positive and negative elements of certain low frequency dynamic components that are not rejected by the one-Hz low-pass filters of the data system. These low frequency effects may be due to tunnel circuit phenomena and other sources. The magnitude of the dwell effect depends on dynamic pressure, with angle of attack and Mach number influencing the strength of this dependence. An analysis is presented which suggests that the magnitude of the rectification error depends on the ratio of measurement dwell time to the period of the low-frequency dynamics, as well as the amplitude of the dynamics The essential conclusion of this analysis is that extending the dwell time (or, equivalently, replicating short-dwell data points) reduces the rectification error.

DeLoach, R.↗

Phase-Shifting Liquid Crystal Interferometers for Microgravity Fluid Physics

The initial focus of this project was to eliminate both of these problems in the Liquid Crystal Point-Diffraction Interferometer (LCPDI). Progress toward that goal will be described, along with the demonstration of a phase shifting Liquid Crystal Shearing Interferometer (LCSI) that was developed as part of this work. The latest LCPDI, other than a lens to focus the light from a test section onto a diffracting microsphere within the interferometer and a collimated laser for illumination, the pink region contained within the glass plates on the rod-mounted platform is the complete interferometer. The total width is approximately 1.5 inches with 0.25 inches on each side for bonding the electrical leads. It is 1 inch high and there are only four diffracting microspheres within the interferometer. As a result, it is very easy to align, achieving the first goal. The liquid crystal electro-optical response time is a function of layer thickness, with thinner devices switching faster due to a reduction in long-range viscoelastic forces between the LC molecules. The LCPDI has a liquid crystal layer thickness of 10 microns, which is controlled by plastic or glass microspheres embedded in epoxy 'pads' at the corners of the device. The diffracting spheres are composed of polystyrene/divinyl benzene polymer with an initial diameter of 15 microns. The spheres deform slightly when the interferometer is assembled to conform to the spacing produced by the microsphere-filled epoxy spacer pads. While the speed of this interferometer has not yet been tested, previous LCPDIs fabricated at the Laboratory for Laser Energetics switched at a rate of approximately 3.3 Hz, a factor of 10 slower than desired. We anticipate better performance when the speed of these interferometers is tested since they are approximately three times thinner. Phase shifting in these devices is a function of the AC voltage level applied to the liquid crystal. As the voltage increases, the dye in the liquid crystal tends to become more transparent, thus introducing a rather large amount of error into the phase-shifting measurement. While that error can be greatly reduced by normalization, we prefer eliminating the source of the error. To that end, we have pursued development of a 'blend' of custom dyes that will not exhibit these properties. That goal has not yet been fully achieved. Guardalben, et al, presented a similar set of interferograms in a paper partially funded by this grant. Shearing interferometers are a second class of common path interferometers. Typically they consist of a thick glass plate optimized for equal reflection from the front and back surface. While not part of the original thrust of the project, through the course of laboratory work, we demonstrated a prototype of a shearing interferometer capable of phase shifting using a commercial liquid crystal retardation plate. A schematic of this liquid crystal shearing interferometer (LCSI) and a sample set of interferograms are in the reference. This work was also supported by the U.S. Department of Energy Office of Inertial Confinement Fusion under Cooperative Agreement No. DE-FC03-92SF19460, the University of Rochester, and the New York State Energy Research and Development Authority. The support of DOE does not constitute an endorsement by DOE of the views expressed in this article. Additional information is included in the original extended abstract.

Griffin, DeVon W.↗

A method for remote sensing the emissivity, fractional cloud cover and cloud top temperature of high-level, thin clouds

A methodology for retrieving the emissivity, cloud cover and cloud top temperature of high-level, thin clouds is developed and described. In the thermal infrared windows, the outgoing radiances from the earth's atmosphere contain information about cloud emissivity and cloud top temperature. This information is clearly demonstrated in the brightness temperature difference curves of two window channels. For the purpose of illustration, two window channels centered at 810 and 930 cm are chosen to construct the brightness temperature difference curves for a range of cloud top temperatures. These curves vary for different cloud top temperatures, and along each of these curves the emissivity changes. The brightness temperature difference method is used in a simulation study to demonstrate the feasibility of retrieving the cloud top temperature and emissivity by the utilization of measurements in two window channels. As expected, a perfect retrieval is found if perfect measurements and ideal atmospheric conditions are assumed. If a random error, which has a normal distribution with a mean of zero and standard deviation of + or - 0.5 C, is imposed to the measurements, a reasonable retrieval is found for emissivity greater than 0.3. The algorithm has been applied to a limited amount of HIRS2 data, which has 3.7, 3.98 and 11 micron channels. The cloud top temperature, emissivity and cloud cover are determined by using these channels.

Wu, Man-Li C.↗

Reciprocal - MSE and SNR as distinct performance measures in below-threshold communication.

The possible advantages of using algorithms that are minimum mean-square-error (MSE) optimal, or other averaging-type demodulators with frequency position modulation (FPM), are investigated. An attempt is made to describe the performance of the optimal and various suboptimal demodulators in terms of three parameters which depend on SNR and bandwidth expansion. The performance measures investigated are the reciprocal of the normalized mean-square error and the output SNR, which are different in the below-threshold region. The former is compared to the rate-distortion bound. The possible advantage of averaging-type discriminators from the point of view of the threshold is discussed.

Bar-David, I.↗

Fault detection of helicopter gearboxes using the multi-valued influence matrix method

In this paper we investigate the effectiveness of a pattern classifying fault detection system that is designed to cope with the variability of fault signatures inherent in helicopter gearboxes. For detection, the measurements are monitored on-line and flagged upon the detection of abnormalities, so that they can be attributed to a faulty or normal case. As such, the detection system is composed of two components, a quantization matrix to flag the measurements, and a multi-valued influence matrix (MVIM) that represents the behavior of measurements during normal operation and at fault instances. Both the quantization matrix and influence matrix are tuned during a training session so as to minimize the error in detection. To demonstrate the effectiveness of this detection system, it was applied to vibration measurements collected from a helicopter gearbox during normal operation and at various fault instances. The results indicate that the MVIM method provides excellent results when the full range of faults effects on the measurements are included in the training set.

Chin, Hsinyung↗

Effect of gyro verticality error on lateral autoland tracking performance for an inertially smoothed control law

The results of a simulation study performed to determine the effects of gyro verticality error on lateral autoland tracking and landing performance are presented. A first order vertical gyro error model was used to generate the measurement of the roll attitude feedback signal normally supplied by an inertial navigation system. The lateral autoland law used was an inertially smoothed control design. The effect of initial angular gyro tilt errors (2 deg, 3 deg, 4 deg, and 5 deg), introduced prior to localizer capture, were investigated by use of a small perturbation aircraft simulation. These errors represent the deviations which could occur in the conventional attitude sensor as a result of the maneuver-induced spin-axis misalinement and drift. Results showed that for a 1.05 deg per minute erection rate and a 5 deg initial tilt error, ON COURSE autoland control logic was not satisfied. Failure to attain the ON COURSE mode precluded high control loop gains and localizer beam path integration and resulted in unacceptable beam standoff at touchdown.

Thibodeaux, J. J.↗

Photon-scattering cross sections of H2 and He measured with synchrotron radiation

Total (elastic + inelastic) differential photon-scattering cross sections have been measured for H2 gas and for He, using an X-ray beam. Absolute measured cross sections agree with theory within the probable errors. Relative cross sections (normalized to theory at large S) agree to better than 1% with theoretical values calculated from wave functions that include the effect of electron-electron Coulomb correlation, but the data deviate significantly from theoretical independent-particle (e.g., Hartree-Fock) results. The ratios of measured absolute He cross sections to those of H2, at any given S, also agree to better than 1% with theoretical He-to-H2 cross-section ratios computed from correlated wave functions. It appears that photon scattering constitutes a very promising tool for probing electron correlation in light atoms and molecules. The degree of polarization of the synchrotron radiation beam has been measured by rotating the scattering plane about the beam axis; results are compared with theory.

Ice, G. E.↗

Photon scattering cross sections of H2 and He measured with synchrotron radiation

Total (elastic + inelastic) differential photon scattering cross sections have been measured for H2 gas and He, using an X-ray beam. Absolute measured cross sections agree with theory within the probable errors. Relative cross sections (normalized to theory at large S) agree to better than one percent with theoretical values calculated from wave functions that include the effect of electron-electron Coulomb correlation, but the data deviate significantly from theoretical independent-particle (e.g., Hartree-Fock) results. The ratios of measured absolute He cross sections to those of H2, at any given S, also agree to better than one percent with theoretical He-to-H2 cross-section ratios computed from correlated wave functions. It appears that photon scattering constitutes a very promising tool for probing electron correlation in light atoms and molecules.

Ice, G. E.↗

The Effect of Ultrapolish on a Transonic Axial Rotor

Back-to-back testing has been done using NASA fan rotor 67 in the Glenn Research Center W8 Axial Compressor Test Facility. The rotor was baseline tested with a normal industrial RMS surface finish of 0.5-0.6 m (20-24 microinches) at 60, 80 and 100% of design speed. At design speed the tip relative Mach number was 1.38. The blades were then removed from the facility and ultrapolished to a surface finish of 0.125 m (5 microinch) or less and retested. At 100% speed near the design point, the ultrapolished blades showed approximately 0.3 - 0.5% increase in adiabatic efficiency. The difference was greater near maximum flow. Due to increased relative measurement error at 60 and 80% speed, the performance difference between the normal and ultrapolished blades was indeterminate at these speeds.

Roberts, William B.↗

CORRELATED ERRORS IN EARTH POINTING MISSIONS

Two different Earth-pointing missions dealing with attitude control and dynamics changes illustrate concerns with correlated error sources and coupled effects that can occur. On the OrbView-2 (OV-2) spacecraft, the assumption of a nearly-inertially-fixed momentum axis was called into question when a residual dipole bias apparently changed magnitude. The possibility that alignment adjustments and/or sensor calibration errors may compensate for actual motions of the spacecraft is discussed, and uncertainties in the dynamics are considered. Particular consideration is given to basic orbit frequency and twice orbit frequency effects and their high correlation over the short science observation data span. On the Tropical Rainfall Measuring Mission (TRMM) spacecraft, the switch to a contingency Kalman filter control mode created changes in the pointing error patterns. Results from independent checks on the TRMM attitude using science instrument data are reported, and bias shifts and error correlations are discussed. Various orbit frequency effects are common with the flight geometry for Earth pointing instruments. In both dual-spin momentum stabilized spacecraft (like OV-2) and three axis stabilized spacecraft with gyros (like TRMM under Kalman filter control), changes in the initial attitude state propagate into orbit frequency variations in attitude and some sensor measurements. At the same time, orbit frequency measurement effects can arise from dynamics assumptions, environment variations, attitude sensor calibrations, or ephemeris errors. Also, constant environment torques for dual spin spacecraft have similar effects to gyro biases on three axis stabilized spacecraft, effectively shifting the one-revolution-per-orbit (1-RPO) body rotation axis. Highly correlated effects can create a risk for estimation errors particularly when a mission switches an operating mode or changes its normal flight environment. Some error effects will not be obvious from attitude sensor measurement residuals, so some independent checks using imaging sensors are essential and derived science instrument attitude measurements can prove quite valuable in assessing the attitude accuracy.

Steve Bilanow↗

Sensitivity of C-Band Polarimetric Radar-Based Drop Size Distribution Measurements to Maximum Diameter Assumptions

The estimation of rain drop size distribution (DSD) parameters from polarimetric radar observations is accomplished by first establishing a relationship between differential reflectivity (Z(sub dr)) and the central tendency of the rain DSD such as the median volume diameter (D0). Since Z(sub dr) does not provide a direct measurement of DSD central tendency, the relationship is typically derived empirically from rain drop and radar scattering models (e.g., D0 = F[Z (sub dr)] ). Past studies have explored the general sensitivity of these models to temperature, radar wavelength, the drop shape vs. size relation, and DSD variability. Much progress has been made in recent years in measuring the drop shape and DSD variability using surface-based disdrometers, such as the 2D Video disdrometer (2DVD), and documenting their impact on polarimetric radar techniques. In addition to measuring drop shape, another advantage of the 2DVD over earlier impact type disdrometers is its ability to resolve drop diameters in excess of 5 mm. Despite this improvement, the sampling limitations of a disdrometer, including the 2DVD, make it very difficult to adequately measure the maximum drop diameter (D(sub max)) present in a typical radar resolution volume. As a result, D(sub max) must still be assumed in the drop and radar models from which D0 = F[Z(sub dr)] is derived. Since scattering resonance at C-band wavelengths begins to occur in drop diameters larger than about 5 mm, modeled C-band radar parameters, particularly Z(sub dr), can be sensitive to D(sub max) assumptions. In past C-band radar studies, a variety of D(sub max) assumptions have been made, including the actual disdrometer estimate of D(sub max) during a typical sampling period (e.g., 1-3 minutes), D(sub max) = C (where C is constant at values from 5 to 8 mm), and D(sub max) = M*D0 (where the constant multiple, M, is fixed at values ranging from 2.5 to 3.5). The overall objective of this NASA Global Precipitation Measurement Mission (GPM/PMM Science Team)-funded study is to document the sensitivity of DSD measurements, including estimates of D0, from C-band Z(sub dr) and reflectivity to this range of D(sub max) assumptions. For this study, GPM Ground Validation 2DVD's were operated under the scanning domain of the UAHuntsville ARMOR C-band dual-polarimetric radar. Approximately 7500 minutes of DSD data were collected and processed to create gamma size distribution parameters using a truncated method of moments approach. After creating the gamma parameter datasets the DSD's were then used as input to a T-matrix model for computation of polarimetric radar moments at C-band. All necessary model parameterizations, such as temperature, drop shape, and drop fall mode, were fixed at typically accepted values while the D(sub max) assumption was allowed to vary in sensitivity tests. By hypothesizing a DSD model with D(sub max) (fit) from which the empirical fit to D0 = F[Z(sub dr)] was derived via non-linear least squares regression and a separate reference DSD model with D(sub max) (truth), bias and standard error in D0 retrievals were estimated in the presence of Z(sub dr) measurement error and hypothesized mismatch in D(sub max) assumptions. Although the normalized standard error for D0 = F[Z(sub dr)r] can increase slightly (as much as from 11% to 16% for all 7500 DSDs) when the D(sub max) (fit) does not match D(sub max) (truth), the primary impact of uncertainty in D(sub max) is a potential increase in normalized bias error in D0 (from 0% to as much as 10% over all 7500 DSDs, depending on the extent of the mismatch between D(sub max) (fit) and D(sub max) (truth)). For DSDs characterized by large Z(sub dr) (Z(sub dr) > 1.5 to 2.0 dB), the normalized bias error for D0 estimation at C-band is sometimes unacceptably large (> 10%), again depending on the extent of the hypothesized D(sub max) mismatch. Modeled errors in D0 retrievals from Z(sub dr) at C-band are demonstrated in detail and comparedo similar modeled retrieval errors at S-band and X-band where the sensitivity to D(sub max) is expected to be less. The impact of D(sub max) assumptions to the retrieval of other DSD parameters such as Nw, the liquid water content normalized intercept parameter, are also explored. Likely implications for DSD retrievals using C-band polarimetric radar for GPM are assessed by considering current community knowledge regarding D(sub max) and quantifying the statistical distribution of Z(sub dr) from ARMOR over a large variety of meteorological conditions. Based on these results and the prevalence of C-band polarimetric radars worldwide, a call for more emphasis on constraining our observational estimate of D(sub max) within a typical radar resolution volume is made

Carey, Lawrence D.↗

Dynamic-overlapped-grid simulation of aerodynamically determined relative motion

Currently, there is a need to develop a means of analyzing and studying unsteady flowfields which involve multiple component configurations with at least one of the components in relative motion with respect to the others. Two of the important phenomena that such analyses can help to understand are the unsteady aerodynamic interference and the boundary-induced component of the flowfield. With this motivation, a computational method is developed which couples the governing equations of the unsteady flowfield and the rigid-body dynamics in six degrees-of-freedom. These equations are solved on composite meshes of overlapped subdomain grids which can move with respect to each other. Initially, several measures that reduce the numerical error are studied and compared with the exact solution of a moving normal shock in a tube. It is concluded that a second-order accurate method, for spatial and temporal discretizations as well as for the moving subdomain interpolations, is needed as a minimum measure. Furthermore, the CFL numbers should be restricted to unity. Then, the method is used to simulate the flowfield history and predict the aerodynamically determined trajectory of a store dropped from its initial position under a wing.

Yen, Guan-Wei↗