Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “non-invasive imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Joint Inversion of Surface Electrical Resistivity Tomography and Seismic Refraction Data between the 200 Areas

Geologic stratigraphy on the Hanford Site influences groundwater and contaminant migration through the aquifer system and the vadose zone. The current geologic framework model (GFM) relies heavily on a sparse distribution of borehole data in some locations to map geologic contacts and hydrologic properties in the subsurface. Non-invasive geophysical methods such as electrical resistivity tomography (ERT), transient electromagnetic surveying, and seismic imaging are being used at Hanford to map subsurface structure in areas with limited well observations. This is to develop and mature the capability of geophysical methods to aid in GFM refinement, to identify regions of subsurface complexity, and for optimal well siting. A joint inversion of co-located seismic refraction and ERT data was carried out for data collected on a ~2.3-km profile between the 200 Areas on the Hanford Site. While ERT and seismic refraction images have sensitivity to overlapping physical properties (porosity, moisture content, lithology), the resolution and physics used to acquire each of these datasets are different and therefore information can be different or mutually complementary. Performing a joint inversion provides a reasonable option for a coherent, coupled interpretation for mutually complementary datasets. Between the 200 Areas, there are few boreholes to interpret the geologic framework model, and these data sets were obtained to provide a first line of evidence toward identifying stratigraphic structure. The seismic refraction and ERT data were independently inverted during fiscal year 2022 and broadly showed a two-layer structure with a trough-like feature that is ~1 km wide and upwards of 150 m deep. The depth of the trough feature was greater in the ERT image compared to the seismic image, which indicated a maximum depth of approximately 110 m. The objective of the joint inversion described in this report was to invert the seismic refraction and ERT data together while constraining the ERT image to be structurally similar to the seismic refraction image. The approach was applied using the geophysical inverse modeling program E4D, which has the capability to invert first-arrival times from seismic refraction data and ERT resistances using a “cross-gradient” constraint. The application of cross-gradient constraints with different weights produces ERT models that show a high degree of similarity within the upper 100 m (above ~120 m elevation). None of the ERT models show an improved structural similarity to the seismic result; therefore, it is recommended that further attempts to jointly interpret these models focus on petrophysics and image resolution. Petrophysical measurements of core samples would improve knowledge of what drives the ERT response in this region and, along with downhole geophysical measurements, could be used to “ground truth” the surface-based geophysical results. Image resolution studies would provide insight into which regions of the inverted images are reliable and which regions are poorly constrained.

58 GEOSCIENCES↗

Imaging shapes of atomic nuclei in high-energy nuclear collisions

Atomic nuclei are self-organized, many-body quantum systems bound by strong nuclear forces within femtometre-scale space. These complex systems manifest a variety of shapes, traditionally explored using non-invasive spectroscopic techniques at low energies. However, at these energies, their instantaneous shapes are obscured by long-timescale quantum fluctuations, making direct observation challenging. Here we introduce the collective-flow-assisted nuclear shape-imaging method, which images the nuclear global shape by colliding them at ultrarelativistic speeds and analysing the collective response of outgoing debris. This technique captures a collision-specific snapshot of the spatial matter distribution within the nuclei, which, through the hydrodynamic expansion, imprints patterns on the particle momentum distribution observed in detectors. We benchmark this method in collisions of ground-state uranium-238 nuclei, known for their elongated, axial-symmetric shape. Our findings show a large deformation with a slight deviation from axial symmetry in the nuclear ground state, aligning broadly with previous low-energy experiments. This approach offers a new method for imaging nuclear shapes, enhances our understanding of the initial conditions in high-energy collisions and addresses the important issue of nuclear structure evolution across energy scales.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Detection and imaging of chemicals and hidden explosives using terahertz time-domain spectroscopy and deep learning

Detecting concealed chemicals and explosives remains a critical challenge in global security. Terahertz time-domain spectroscopy (THz-TDS) offers a promising non-invasive and stand-off detection technique owing to its ability to penetrate optically opaque materials without causing ionization damage. While many chemicals exhibit distinct spectral features in the terahertz range, conventional terahertz-based detection methods often struggle in real-world environments, where variations in sample geometry, thickness, and packaging can lead to inconsistent spectral responses. In this study, we present a chemical imaging system that integrates THz-TDS with deep learning to enable accurate pixel-level identification and classification of different explosives. Operating in reflection mode and enhanced with plasmonic nanoantenna arrays, our THz-TDS system achieves a peak dynamic range of 96 dB and a detection bandwidth of 4.5 THz, supporting practical, stand-off operation. By analyzing individual time-domain pulses with deep neural networks, the system exhibits strong resilience to environmental variations and sample inconsistencies. Blind testing across eight chemicals—including pharmaceutical excipients and explosive compounds—resulted in an average classification accuracy of 99.42% at the pixel level. Notably, the system maintained an average accuracy of 88.83% when detecting explosives concealed under opaque paper coverings, demonstrating its robust generalization capability. These results highlight the potential of combining advanced terahertz spectroscopy with neural networks for highly sensitive and specific chemical and explosive detection in diverse and operationally relevant scenarios.

Imaging and sensing↗

Personalized and uncertainty-aware coronary hemodynamics simulations: From Bayesian estimation to improved multi-fidelity uncertainty quantification

Non-invasive simulations of coronary hemodynamics have improved clinical risk stratification and treatment outcomes for coronary artery disease, compared to relying on anatomical imaging alone. However, simulations typically use empirical approaches to distribute total coronary flow amongst the arteries in the coronary tree, which ignores patient variability, the presence of disease, and other clinical factors. Further, uncertainty in the clinical data often remains unaccounted for in the modeling pipeline. We present an end-to-end uncertainty-aware pipeline to (1) personalize coronary flow simulations by incorporating vessel-specific coronary flows as well as cardiac function; and (2) predict clinical and biomechanical quantities of interest with improved precision, while accounting for uncertainty in the clinical data. We assimilate patient-specific measurements of myocardial blood flow from clinical CT myocardial perfusion imaging to estimate branch-specific coronary artery flows. Simulated noise in the clinical data is used to estimate the joint posterior distributions of the model parameters using adaptive Markov Chain Monte Carlo sampling. Additionally, the posterior predictive distribution for the relevant quantities of interest is determined using a new approach combining multi-fidelity Monte Carlo estimation with non-linear, data-driven dimensionality reduction. This leads to improved correlations between high- and low-fidelity model outputs. Our framework accurately recapitulates clinically measured cardiac function as well as branch-specific coronary flows under measurement noise uncertainty. We observe substantial reductions in confidence intervals for estimated quantities of interest compared to single-fidelity Monte Carlo estimation and state-of-the-art multi-fidelity Monte Carlo methods. This holds especially true for quantities of interest that showed limited correlation between the low- and high-fidelity model predictions. In addition, the proposed multi-fidelity Monte Carlo estimators are significantly cheaper to compute than traditional estimators, under a specified confidence level or variance. The proposed pipeline for personalized and uncertainty-aware predictions of coronary hemodynamics is based on routine clinical measurements and recently developed techniques for CT myocardial perfusion imaging. The proposed pipeline offers significant improvements in precision and reduction in computational cost.

Bayesian parameter estimation↗

Time-lapse electrical resistivity and induced polarization monitoring of a simulated ecosystem-scale coastal flooding experiment

Accurate estimation of the spatio-temporal variation in soil saturation and salt concentration is valuable for calibrating and evaluating Earth system models as well as detecting important eco-hydrological interactions. Such representative models play a vital role in investigating the stability of ecosystems facing changing hydrologic disturbance regimes. Ecosystem-scale field experiments are a useful way to capture hydrological disturbance and gain a deeper understanding of the complex mechanisms driving environmental changes. However, previous studies have not explored the use of quantitative imaging at a large spatial scale to reproduce breakthrough curves and inform system response and recovery following hydrologic disturbance events. Therefore, in this study, non-invasive geophysical methods were used to capture the spatio-temporal variation in subsurface saturation and salt concentrations during an ecosystem-scale coastal forest flooding experiment.

coastal↗

Patch2Self2: Self-supervised Denoising on Coresets via Matrix Sketching

Diffusion MRI (dMRI) non-invasively maps brain white matter yet necessitates denoising due to low signal-to-noise ratios. Patch2Self (P2S) employing self-supervised techniques and regression on a Casorati matrix effectively denoises dMRI images and has become the new de-facto standard in this field. P2S however is resource intensive both in terms of running time and memory usage as it uses all voxels (n) from all-but-one held-in volumes (d-1) to learn a linear mapping Phi : \mathbb R ^ n x(d-1) \mapsto \mathbb R ^ n for denoising the held-out volume. The increasing size and dimensionality of higher resolution dMRI acquisitions can make P2S infeasible for large-scale analyses. This work exploits the redundancy imposed by P2S to alleviate its performance issues and inspect regions that influence the noise disproportionately. Specifically this study makes a three-fold contribution: (1) We present Patch2Self2 (P2S2) a method that uses matrix sketching to perform self-supervised denoising. By solving a sub-problem on a smaller sub-space so called coreset we show how P2S2 can yield a significant speedup in training time while using less memory. (2) We present a theoretical analysis of P2S2 focusing on determining the optimal sketch size through rank estimation a key step in achieving a balance between denoising accuracy and computational efficiency. (3) We show how the so-called statistical leverage scores can be used to interpret the denoising of dMRI data a process that was traditionally treated as a black-box. Experimental results on both simulated and real data affirm that P2S2 maintains denoising quality while significantly enhancing speed and memory efficiency achieved by training on a reduced data subset.

Fadnavis, Shreyas↗

Laser-Induced Fluorescence for Monitoring Environmental Contamination and Stress in the Moss Thuidium plicatile

The ability to detect, measure, and locate the source of contaminants, especially heavy metals and radionuclides, is of ongoing interest. A common tool for contaminant identification and bioremediation is vegetation that can accumulate and indicate recent and historic pollution. However, large-scale sampling can be costly and labor-intensive. Hence, non-invasive in-situ techniques such as laser-induced fluorescence (LIF) are becoming useful and effective ways to observe the health of plants through the excitation of organic molecules, e.g., chlorophyll. The technique presented utilizes images collected of LIF in moss to identify different metals and environmental stressors. Analysis through image processing of LIF response was key to identifying Cu, Zn, Pb, and a mixture of the metals at nmol/cm 2 levels. Specifically, the RGB values from each image were used to create density histograms of each color channel’s relative pixel abundance at each decimal code value. These histograms were then used to compare color shifts linked to the successful identification of contaminated moss samples. Photoperiod and extraneous environmental stressors had minimal impact on the histogram color shift compared to metals and presented with a response that differentiated them from metal contamination.

59 BASIC BIOLOGICAL SCIENCES↗

Optical contrast analysis of α -RuCl 3 nanoflakes on oxidized silicon wafers

α-RuCl 3 , a narrow-band Mott insulator with a large work function, offers intriguing potential as a quantum material or as a charge acceptor for electrical contacts in van der Waals devices. In this work, we perform a systematic study of the optical reflection contrast of α-RuCl 3 nanoflakes on oxidized silicon wafers and estimate the accuracy of this imaging technique to assess the crystal thickness. Via spectroscopic micro-ellipsometry measurements, we characterize the wavelength-dependent complex refractive index of α-RuCl 3 nanoflakes of varying thickness in the visible and near-infrared. Building on these results, we simulate the optical contrast of α-RuCl 3 nanoflakes with thicknesses below 100 nm on SiO 2 /Si substrates under different illumination conditions. We compare the simulated optical contrast with experimental values extracted from optical microscopy images and obtain good agreement. Finally, we show that optical contrast imaging allows us to retrieve the thickness of the RuCl 3 nanoflakes exfoliated on an oxidized silicon substrate with a mean deviation of –0.2 nm for thicknesses below 100 nm with a standard deviation of only 1 nm. Our results demonstrate that optical contrast can be used as a non-invasive, fast, and reliable technique to estimate the α-RuCl 3 thickness.

2D materials↗

Using Low-Field Nuclear Magnetic Resonance and X-Ray Computed Microtomography Imaging to Explore Potential of Microbially-Induced Calcium Carbonate Precipitation Treatment to Seal Shale Fractures

Microbially-induced calcium carbonate precipitation (MICP) is a biological process in which microbially produced urease enzymes convert urea and calcium into solid calcium carbonate (CaCO 3 ) deposits. Studies have shown that MICP can be used to seal fractures in shale, raising the possibility of applying this technology to restimulate fracking wells by plugging underperforming fractures. For this and other applications to become a reality, non-invasive tools are needed to determine how effectively MICP seals shale fractures under subsurface conditions. In this study, a 2.54 cm wide and 5.08 cm long Marcellus shale core with a single, ~1 mm wide fracture held open by sand "proppant" underwent MICP-treatment at 60°C until reaching three orders of magnitude permeability reduction. Low-field nuclear magnetic resonance (LF-NMR) and X-Ray computed microtomography (μ-CT) techniques were used to assess the extent of biomineralization within the fracture. These tools revealed that while CaCO 3 precipitation occurred throughout the fracture, there was preferential precipitation around proppant, and the core sealed at the effluent end before filling most of the fracture. Both tools were able to independently calculate of the amount of solid biomineral formed inside the fracture. Furthermore, this study found that the distribution of proppant within the shale fracture was an important parameter controlling the degree of biomineralization.

clastic rock↗

Low latency optical-based mode tracking with machine learning deployed on FPGAs on a tokamak

Active feedback control in magnetic confinement fusion devices is desirable to mitigate plasma instabilities and enable robust operation. Optical high-speed cameras provide a powerful, non-invasive diagnostic and can be suitable for these applications. Here, in this study, we process high-speed camera data, at rates exceeding 100 kfps, on in situ field-programmable gate array (FPGA) hardware to track magnetohydrodynamic (MHD) mode evolution and generate control signals in real time. Our system utilizes a convolutional neural network (CNN) model, which predicts the n = 1 MHD mode amplitude and phase using camera images with better accuracy than other tested non-deep-learning-based methods. By implementing this model directly within the standard FPGA readout hardware of the high-speed camera diagnostic, our mode tracking system achieves a total trigger-to-output latency of 17.6 μs and a throughput of up to 120 kfps. This study at the High Beta Tokamak-Extended Pulse (HBT-EP) experiment demonstrates an FPGA-based high-speed camera data acquisition and processing system, enabling application in real-time machine-learning-based tokamak diagnostic and control as well as potential applications in other scientific domains.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Retinal microvascular and neuronal pathologies probed in vivo by adaptive optical two-photon fluorescence microscopy

The retina, behind the transparent optics of the eye, is the only neural tissue whose physiology and pathology can be non-invasively probed by optical microscopy. The aberrations intrinsic to the mouse eye, however, prevent high-resolution investigation of retinal structure and function in vivo. Optimizing the design of a two-photon fluorescence microscope (2PFM) and sample preparation procedure, we found that adaptive optics (AO), by measuring and correcting ocular aberrations, is essential for resolving putative synaptic structures and achieving three-dimensional cellular resolution in the mouse retina in vivo. Applying AO-2PFM to longitudinal retinal imaging in transgenic models of retinal pathology, we characterized microvascular lesions with sub-capillary details in a proliferative vascular retinopathy model, and found Lidocaine to effectively suppress retinal ganglion cell hyperactivity in a retinal degeneration model. Tracking structural and functional changes at high-resolution longitudinally, AO-2PFM enables microscopic investigations of retinal pathology and pharmacology for disease diagnosis and treatment in vivo.

59 BASIC BIOLOGICAL SCIENCES↗

Quantitative local state of charge mapping by operando electrochemical fluorescence microscopy in porous electrodes

We introduce operando quantitative electrochemical fluorescence state of charge mapping (QEFSM), a non-invasive technique to study operating electrochemical systems along with a new design of optically transparent microfluidic redox flow cells compatible with the most demanding optical requirements. QEFSM allows quantitative mappings of the concentration of a particular oxidation state of a redox-active species within a porous electrode during its operation. In this study, we used confocal microscopy to map the fluorescence signal of the reduced form of 2,7-anthraquinone disulfonate (AQDS) in a set of multistep-chronoamperometry experiments. Calibrating these images and incorporating an analytical model of quinhydrone heterodimer formation with no free parameters, and accounting for the emission of each species involved, we determined the local molecular concentration and the state of charge (SOC) fields within a commercial porous electrode during operation. With this method, electrochemical conversion and species advection, reaction and diffusion can be monitored at heretofore unprecedented transverse and axial resolution (1 μm and 25 μm, respectively) at frame rates of 0.5 Hz, opening new routes to understanding local electrochemical processes in porous electrodes. Here, we observed pore-scale SOC inhomogeneities appearing when the fraction of electroactive species converted in a single pass through the electrode becomes large.

42 ENGINEERING↗

Evaluating User Errors and Temporal Trends in Marine Fish Communities Using 360-Degree Underwater Photography

The use of environmental DNA (eDNA) sampling has been proposed as a complementary method to monitor fish species in marine environments, offering a non-invasive and potentially more efficient approach to marine species observations. eDNA monitoring could be especially useful in and around sites targeted for marine energy generation as these regions need regular monitoring that would be impractical with traditional techniques. Before we can fully rely upon eDNA, we must first verify its accuracy against other proven methods, such as the use of underwater photography. In this study, I deployed a 360-degree camera in the tidal channel of Sequim Bay once a month during several hours overlapping slack tide. I investigated how having multiple people identify and count fish on underwater images could affect the overall results. Using chi square tests in R, I compared my fish identifications and counts to those made by another intern on the same images recorded in August. I found significant differences in the number of species identified and the total individual counts between the two different datasets. I also tested the statistical differences in both Shannon diversity and Pielou evenness indices between the August, September, and November camera deployments using a Hutcheson t-test. Only one significant difference was found in the Shannon index comparisons, and none were found between the Pielou evenness comparisons. These findings show that if multiple identifiers are used to process underwater images, quality control checks must be made to reduce the potential for error. This also points toward the possibility to leverage more advanced image analysis processes, such as automated image analysis software. The findings from this study also show that the dynamics of marine fish communities can vary over a few months; however, further analysis is needed to determine the extent of the seasonal changes in Sequim Bay.

59 BASIC BIOLOGICAL SCIENCES↗

Revolutionizing Waste Management: AI-Powered Real-Time Characterization for Efficient Handling of Non-Recyclable Municipal Solid Waste

According to EPA, -300 MM tons of municipal solid waste (MSW) was available in the US as of 2018. Of that total material, nearly 50% was landfilled resulting in a significant loss for the potential to convert its energy value into cost effective and sustainable biofuels. Redirecting this material away from the landfill and into conversion ready feedstock for energy generation can directly address DOE's selling price < $2.50/GGE while securing the US national energy independence [1]. However, the paramount challenges in any rational fuel conversion strategy are understanding the chemical makeup, quality and associated calorific value of the MSW. Understanding these parameters is critical in achieving any acceptable fuel conversion and requires rapid characterization followed by accurate separation technologies. Therefore, we are proposing to address the rapid characterization by building a non-invasive, rapid, and highly accurate Artificial Intelligence (AI)-enabled spectrometric/optical approach augmented with multi-sensory information for advanced characterization of domestic heterogeneous MSW. North Carolina State University (NCSU) and the National Renewable Energy Laboratory (NREL), in partnership with strong support from the Town of Cary and IBM, Inc., will closely work together to implement this ground-breaking technology for the effective characterization of MSW for sustainable and affordable production of conversion-ready feedstocks, while solving the environment issue of planetary proportions.

artificial intelligence↗

Conditional guided generative diffusion for particle accelerator beam diagnostics

Abstract Advanced accelerator-based light sources such as free electron lasers (FEL) accelerate highly relativistic electron beams to generate incredibly short (10s of femtoseconds) coherent flashes of light for dynamic imaging, whose brightness exceeds that of traditional synchrotron-based light sources by orders of magnitude. FEL operation requires precise control of the shape and energy of the extremely short electron bunches whose characteristics directly translate into the properties of the produced light. Control of short intense beams is difficult due to beam characteristics drifting with time and complex collective effects such as space charge and coherent synchrotron radiation. Detailed diagnostics of beam properties are therefore essential for precise beam control. Such measurements typically rely on a destructive approach based on a combination of a transverse deflecting resonant cavity followed by a dipole magnet in order to measure a beam’s 2D time vs energy longitudinal phase-space distribution. In this paper, we develop a non-invasive virtual diagnostic of an electron beam’s longitudinal phase space at megapixel resolution (1024 × 1024) based on a generative conditional diffusion model. We demonstrate the model’s generative ability on experimental data from the European X-ray FEL.

43 PARTICLE ACCELERATORS↗

Where do the fish go in winter? A year of observing seasonal changes in Sequim Bay’s nearshore fish community

The use of environmental DNA (eDNA) sampling has been proposed as a complementary method to monitor fish species in marine environments. eDNA offers a non-invasive, cost-effective, and scalable way to detect aquatic species. It is appealing in environments where traditional methods are limited by access or visibility, especially in complex or sensitive habitats such as tidal channels and other marine energy sites. Before eDNA can be fully relied upon, we must verify its accuracy against established methods, like underwater photography. In this study, we collected eDNA samples and concurrently deployed a 360-degree camera near the floating dock of PNNL-Sequim in the tidal channel of Sequim Bay once a month for twelve consecutive months. During deployments, the camera remained on the seafloor for several hours overlapping slack tide and captured time-lapse photographs at ten second intervals. Counts and identifications of fish species observed in the images were used to calculate monthly Shannon diversity and Pielou evenness indices. These values were compared across the months using a Kruskal-Wallis test paired with a Conover-Iman post-hoc test. Cliff’s Delta was also calculated to quantify the effect size of the monthly differences. No fish were observed from December through April, likely due to seasonal behavior changes within the local fish community. Fish returned to the shoreline in May, with the greatest diversity and evenness recorded in September. These findings reveal substantial seasonal variation in nearshore fish communities. Many monthly comparisons were found to contain statistically significant differences within the diversity and evenness, and even more were found to have large effect sizes, signifying large ecological changes throughout the seasons. The absence of fish observed during the winter months is a key outcome of this survey that will hopefully be reflected in the eDNA results still to come, which would help validate the eDNA approach.

59 BASIC BIOLOGICAL SCIENCES↗

Quantum Enhanced Tracker (Final Report)

A new concept of charged particle detector, called Quantum Enhanced Tracker (QET) is proposed and intended for optical imaging of charged particle tracks. We present a quantum-based detection method for reconstructing the spatial profile of an electron beam by passing it through a dilute vapor of rubidium atoms. The perturbation of the atomic spin’s quantum state by the electron beam’s magnetic field is detected via nonlinear magneto-optical polarization rotation. Consequently, the electron beam’s position, size and current density can be measured, and its transverse profile reconstructed by analyzing the polarization rotation of a transverse probe laser. This method was experimentally studied using e-beams with currents ranging from 1 to 200 μA and energies between 10 to 20 keV. The results show that this approach is sensitive to the e-beam current and independent of e-beam energy. This technique provides a potentially 3-D capable approach for non-invasive characterization and monitoring of charged particles used in accelerators and nuclear physics research.

43 PARTICLE ACCELERATORS↗

Review of Ultrasonic Methods for Monitoring, Damage Detection, and Processing of Lithium-Ion Batteries Throughout Their Life Cycle

Lithium-ion batteries (LIBs) are the leading technology used in consumer electronics, electric vehicles, and grid-level electrochemical energy storage applications. The ever-increasing use of LIBs has highlighted a gap in understanding of their behavior throughout their life cycle. Current monitoring systems rely on electrical and sometimes temperature measurements to assess the internal state which limits information about complex electrochemical processes. In response, ultrasonic testing (UT) has shown promise for non-invasive assessment due to its ease of use and sensitivity to mechanical changes which are correlated with electrochemical changes within the battery. We summarize the research in UT methods applied to LIBs throughout their life cycle. We also discuss physics-based and data-driven modeling approaches used to interpret ultrasonic signals in the context of LIBs, with an emphasis on the existing challenge of establishing rigorous links between electrochemical behavior and elastic and poroelastic wave physics to gain insight regarding physical changes in the LIB that can be directly measured using UT. Finally, we discuss the challenges of implementing UT across the LIB life cycle and identify opportunities for further research. This review aims to provide helpful guidance to researchers and practitioners of UT in the growing field of UT for electrochemical battery systems.

25 ENERGY STORAGE↗