Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “noise exposure”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

DESI DR1 Lyα 1D power spectrum: the optimal estimator measurement

The one-dimensional power spectrum P 1D of Lyα forest offers rich insights into cosmological and astrophysical parameters, including constraints on the sum of neutrino masses, warm dark matter models, and the thermal state of the intergalactic medium. We present the measurement of P 1D using the optimal quadratic maximum likelihood estimator applied to over 300,000 Lyα quasars from Data Release 1 (DR1) of the Dark Energy Spectroscopic Instrument (DESI) survey. This sample represents the largest to date for P 1D measurements and is larger than the Extended Baryon Oscillation Spectroscopic Survey (eBOSS) by a factor of 1.7. We conduct a meticulous investigation of instrumental and analysis systematics and quantify their impact on P 1D . This includes the development of a cross-exposure estimator that eliminates the need to model the pipeline noise and has strong potential for future P 1D measurements. We also present new insights into metal contamination through the 1D correlation function. Using a fitting function we measure the evolution of the Lyα forest bias with high precision: b F (z) = (-0.218 ± 0.002) × ((1 + z)/4) 2.96±0.06 . In a companion validation paper, we substantially extend our previous suite of CCD image simulations to quantify the pipeline's exquisite performance accurately. In another companion paper, we present DR1 P 1D measurements using the Fast Fourier Transform (FFT) approach to power spectrum estimation. These two measurements produce a forest bias parameter that differs by 2.2 sigma. However, our model is simplistic, so this disagreement will be investigated in future work.

Lyman alpha forest↗

On-line Measurement of Hydrogen Gas using Raman Spectroscopy for Process Gas Systems

Advanced reprocessing schemes such as the Zircex process are important for continued development of the nuclear fuel cycle. The hydrochlorination reaction of the Zircex process flow sheet for metallic fuels has a known off-gas stream of H 2 (g) and HCl. The flow sheet can be simplified through HCl recycling, which requires detection and quantification of any residual H 2 (g) for safety and purity. In this work, commercially available Raman spectroscopy was applied for low-level, on-line detection of H 2 (g) in process gas streams, and parameters were adjusted to optimize the H 2 (g) Raman signal. Increasing the number of scans and exposure time in the spectrometer increased the signal-to-noise ratio of the H 2 (g) Raman signal, while the gas flow rate was optimized at 2.3 L/min. The limit of detection for H 2 (g) was estimated to be 2,100 ppm H 2 (g) in an N 2 (g) background. This scoping study for the application of Raman spectroscopy for on-line measurements of H 2 (g) shows that H 2 (g) can be detected at low levels (approximately 5% of the lower explosive limit (LEL)) in flowing gas streams.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The Interstellar Mapping And Acceleration Probe High Energy (IMAP-Hi) Neutral Atom Imager

The IMAP-Hi Energetic Neutral Atom (ENA) Imager on NASA’s Interstellar Mapping and Acceleration Probe (IMAP) mission (McComas et al. 2018a, 2025) is designed to measure ENAs from the global interaction between the heliosphere and the local interstellar medium (LISM). These ENAs are initially plasma ions of solar wind origin that are neutralized by charge exchange with the cold neutral atoms of LISM that freely flow through the heliosphere-LISM interaction region. IMAP-Hi consists of two identical single-pixel sensors, each covering the ENA spectral range from 0.44 keV to 15.6 keV over nine contiguous energy passbands and having an approximately conical field-of-view (FOV) of 4.1o full width at half maximum (FWHM). The Hi-45 sensor points 45o relative to the spacecraft spin axis from the antisunward direction; each spacecraft spin, it measures ENA intensity over a circular swath with half-cone angle 45o centered on the ecliptic plane. The Hi-90 sensor points 90o relative to the spin axis; each spacecraft spin, it measures ENA intensity over a great circle in the sky, sampling both the north and south ecliptic poles. As the IMAP spin vector is re-pointed daily toward the Sun, the ecliptic longitude of the swaths moves daily by ∼1o such that a full sky map is acquired by Hi-90 every six months and a complete low latitude (−45o to +45o) map is acquired by Hi-45 annually. The IMAP-Hi sensor design has direct heritage from the IBEX-Hi imager on the Interstellar Boundary Explorer (IBEX) mission, with substantial improvements in energy range, energy resolution, angular resolution, signal-to-noise ratio, and, for ecliptic latitudes within ±45o, temporal resolution and exposure time. The global ENA maps acquired by IMAP-Hi partially overlap in energy and viewing with the ENA maps acquired by the IMAP-Lo and IMAP-Ultra ENA imagers, which we combine to answer fundamental questions about the structure and dynamics of the interaction of the heliosphere and the LISM.

79 ASTRONOMY AND ASTROPHYSICS↗

SDSS-IV MaNGA: a catalogue of spectroscopically detected strong galaxy–galaxy lens candidates

ABSTRACT We spectroscopically detected candidate emission-lines of 8 likely, 17 probable, and 69 possible strong galaxy–galaxy gravitational lens candidates found within the spectra of $\approx 10\, 000$ galaxy targets contained within the completed Mapping of Nearby Galaxies at Apache Point Observatory survey. This search is based upon the methodology of the Spectroscopic Identification of Lensing Objects project, which extends the spectroscopic detection methods of the BOSS Emission-Line Lensing Survey and the Sloan Lens ACS Survey. We scanned the co-added residuals that we constructed from stacks of foreground subtracted row-stacked-spectra so a sigma-clipping method can be used to reject cosmic rays and other forms of transients that impact only a small fraction of the combined exposures. We also constructed narrow-band images from the signal to noise of the co-added residuals to observe signs of lensed source images. We also use several methods to compute the probable strong lensing regime for each candidate lens to determine which candidate background galaxies may reside sufficiently near the galaxy centre for strong lensing to occur. We present the spectroscopic redshifts within a value-added catalogue (VAC) for data release 17 (DR17) of SDSS-IV. We also present the lens candidates, spectroscopic data, and narrow-band images within a VAC for DR17. High resolution follow-up imaging of these lens candidates are expected to yield a sample of confirmed grade-A lenses with sufficient angular size to probe possible discrepancies between the mass derived from a best-fitting lens model, and the dynamical mass derived from the observed stellar velocities.

79 ASTRONOMY AND ASTROPHYSICS↗

Total-Ionizing-Dose Effects on Read Noise of MLC 3-D NAND Memories T

This paper analyzes the total ionizing dose (TID) effects on noise characteristics of commercial multi-level-cell (MLC) 3-D NAND memory technology during the read operation. Additionally, the chips were exposed to a Co-60 gamma-ray source for up to 100 krad(Si) of TID. We find that the number of noisy cells in the irradiated chip increases with TID. Bit-flip noise was more dominant for cells in an erased state during irradiation compared to programmed cells.

3-D NAND Flash↗

Quieting a noisy antenna reproduces photosynthetic light-harvesting spectra

Photosynthesis achieves near unity light-harvesting quantum efficiency yet it remains unknown whether there exists a fundamental organizing principle giving rise to robust light harvesting in the presence of dynamic light conditions and noisy physiological environments. Here, we present a noise-canceling network model that relates noisy physiological conditions, power conversion efficiency, and the resulting absorption spectra of photosynthetic organisms. Using light conditions in full solar exposure, light filtered by oxygenic phototrophs, and light filtered under seawater, we derived optimal absorption characteristics for efficient solar power conversion. We show how light-harvesting antennae can be tuned to maximize power conversion efficiency by minimizing excitation noise, thus providing a unified theoretical basis for the observed wavelength dependence of absorption in green plants, purple bacteria, and green sulfur bacteria.

Science & Technology - Other Topics↗

Developing a robust sensor for infrared imaging bolometers

A new type of large area sensor for infrared imaging bolometers has been developed. It replaces the thin and fragile free-standing metal foils, which typically have been used, with a multi-layer coated sapphire (or diamond) substrate. Sapphire is transparent to mid-infrared wavelengths, is robust against transients, and can be thick enough to even be the vacuum window. The primary radiation absorber is still a thin deposited metal layer, but now it is partially insulated from the supporting sapphire substrate by a black (carbon-based) layer, which also acts as a blackbody remitter. Test results indicate 6× more noise equivalent power density (estimated NEPD = 23 W/m 2 at 5 ms camera exposure time, foil temperature decay time 60 ms) for a 2 μm gold-coated sapphire disk compared to estimated NEP = 4 W/m 2 at 1.8 ms exposure time, with foil decay time 420 ms, for a nominal 2.5 μm thick platinum-free-standing foil.

47 OTHER INSTRUMENTATION↗

Performance testing of the iX Cameras iSpeed 727 high-speed camera

This work evaluated the iX Cameras iSpeed 727, a commercial CMOS-based continuous- recording high-speed camera. Various parameters of importance in the scheme of accurate time-resolved measurements and photonic quantification have been measured under controlled conditions on the bench, using state-of-the-art instrumentation. We will detail the procedures and results of the tests laid out to measure sensor sensitivity, linearity, signal-to-noise ratio and image lag. We also looked into the electronic shutter performance and accuracy, as exposure time is of particular interest to high-speed imaging. The results of the tests show that this camera matches or exceeds the performance of competing units in most aspects, but that, as is the case for other high-speed camera systems, corrections are necessary to make full use of the image data from a quantitative perspective.

42 ENGINEERING↗

Performance Verification of the EXtreme PREcision Spectrograph

The EXtreme PREcision Spectrograph (EXPRES) is a new Doppler spectrograph designed to reach a radial-velocity measurement precision sufficient to detect Earth-like exoplanets orbiting nearby, bright stars. We report on extensive laboratory testing and on-sky observations to quantitatively assess the instrumental radial-velocity measurement precision of EXPRES, with a focused discussion of individual terms in the instrument error budget. We find that EXPRES can reach a single-measurement instrument calibration precision better than 10 cm s{sup −1}, not including photon noise from stellar observations. We also report on the performance of the various environmental, mechanical, and optical subsystems of EXPRES, assessing any contributions to radial-velocity error. For atmospheric and telescope related effects, this includes the fast tip-tilt guiding system, atmospheric dispersion compensation, and the chromatic exposure meter. For instrument calibration, this includes the laser fRequency comb (LFC), flat-field light source, CCD detector, and effects in the optical fibers. Modal noise is mitigated to a negligible level via a chaotic fiber agitator, which is especially important for wavelength calibration with the LFC. Regarding detector effects, we empirically assess the impact on the radial-velocity precision due to pixel-position nonuniformities and charge transfer inefficiency (CTI). EXPRES has begun its science survey to discover exoplanets orbiting G-dwarf and K-dwarf stars, in addition to transit spectroscopy and measurements of the Rossiter–McLaughlin effect.

79 ASTRONOMY AND ASTROPHYSICS↗

Deep Spectroscopy with DESI for Photometric Redshift Training and Calibration

Deep spectroscopic samples can improve photometric redshift (photo-z) estimates and reduce uncertainties on redshift distributions. Such improvements can increase the cosmological constraining power of large imaging-based experiments such as the Vera C. Rubin Observatory’s Legacy Survey of Space and Time (LSST) and mitigate what may be a limiting systematic effect. We present results from the “DESI-Deep pilot” program, which was designed to assess the capability of the Dark Energy Spectroscopic Instrument (DESI) on the 4m Mayall telescope to measure redshifts of galaxies as faint as expected lensing samples for early LSST data (m i ≤ 24.5). We find that DESI is remarkably efficient at this task, with redshift success rates comparable to the results of observations from 10 m class telescopes with only ∼2 × longer integration time (rather than ∼8 × longer as would be expected from aperture-area scaling), while simultaneously achieving ∼30 times larger multiplexing. We also find that the signal-to-noise ratio of the spectra scales as expected for background-limited observations even for the longest exposure times (∼7 hr) and faintest targets in the program. These results demonstrate that DESI could provide the definitive redshift sample for the early years of LSST with a modest investment of observing time. Based upon the results of this program, we provide updated predictions for the time required to collect benchmark samples for photo-z training and calibration using a variety of spectroscopic facilities. Finally, we describe a potential “DESI-Deep” survey designed to train and calibrate photo-z’s for imaging experiments, and provide forecasts of its impact on cosmological inference.

Dey, Biprateep [University of Toronto; University ↗

JWST Noise Floor. II. Systematic Error Sources in JWST NIRCam Time Series

The James Webb Space Telescope (JWST) holds great promise for characterizing atmospheres of transiting exoplanets, potentially providing insights into Earth-sized planets within the habitable zones of M-dwarf host stars if photon-limited performance can be achieved. Here, we discuss the systematic error sources that are expected to be present in grism time-series observations with the NIRCam instrument. We find that pointing jitter and high-gain antenna moves in addition to the detectors’ subpixel crosshatch patterns will produce relatively small variations (less than 6 parts per million, ppm). The time-dependent aperture losses due to thermal instabilities in the optics can also be kept to below 2 ppm. To achieve these low noise values, it is important to employ a sufficiently large (more than 11) extraction aperture. Persistence due to charge-trapping will have a minor (less than 3 ppm) effect on the time series 20 minutes into an exposure and is expected to play a much smaller role than it does for the Hubble Space Telescope WFC3 detectors. We expect detector temperature fluctuations to contribute less than 3 ppm. In total, our estimated noise floor from known systematic error sources is only 9 ppm per visit. We urge caution, however, because unknown systematic error sources could be present in flight and will only be measurable on astrophysical sources such as quiescent stars. We find that reciprocity failure may introduce a perennial instrument offset at the 40 ppm level, so corrections may be needed when a multi-instrument multi-observatory spectrum is stitched together over wide wavelength ranges.

47 OTHER INSTRUMENTATION↗

LAMOST Time-Domain survey: first results of four K2 plates

From Oct. 2019 to Apr. 2020, LAMOST performed a time-domain (TD) spectroscopic survey of four K2 plates with both low- and medium-resolution observations. The low-resolution spectroscopic survey acquired 282 exposures ( ≈ 46.6 h) over 25 nights, yielding a total of about 767 000 spectra, and the medium-resolution survey took 177 exposures ( ≈ 49.1 h) over 27 nights, collecting about 478 000 spectra. More than 70%/50% of low-resolution/medium-resolution spectra have signal-to-noise ratio higher than 10. We determine stellar parameters (e.g., T eff , log g, [Fe/H]) and radial velocity (RV) with different methods, including LASP, DD-Payne and SLAM. In general, these parameter estimations from different methods show good agreement, and the stellar parameter values are consistent with those of APOGEE. We use the Gaia DR2 RV values to calculate a median RV zero point (RVZP) for each spectrograph exposure by exposure, and the RVZP-corrected RVs agree well with the APOGEE data. The stellar evolutionary and spectroscopic masses are estimated based on the stellar parameters, multi-band magnitudes, distances and extinction values. Finally, we construct a binary catalog including about 2700 candidates by analyzing their light curves, fitting the RV data, calculating the binarity parameters from medium-resolution spectra and cross-matching the spatially resolved binary catalog from Gaia EDR3. In conclusion, the LAMOST TD survey is expected to represent a breakthrough in various scientific topics, such as binary systems, stellar activity, stellar pulsation, etc.

79 ASTRONOMY AND ASTROPHYSICS↗

Material and Interface Engineering Strategies to Mitigate Decoherence in Superconducting Qubits

While significant strides have been made to increase the coherence time of superconducting qubits, further advancements are essential for realizing scalable quantum computing. Decoherence is often a result of loss and noise stemming from two-level systems and excess quasiparticles, arising due to material defects, fabrication processes, and ambient exposure, particularly at surfaces and interfaces. Our recent efforts to mitigate these decoherence mechanisms have employed a variety of strategies, including low-loss surface encapsulation materials, advanced substrate preparation techniques, modifications to metal film growth, and the development of novel fabrication processes. The structural and chemical properties of materials, surfaces, and interfaces are studied using scanning probe microscopy, electron microscopy, photoelectron spectroscopy, mass spectrometry, and X-ray diffraction, which is correlated to device performance metrics, including superconducting resonator internal quality factor and qubit T1 time. This information is used to identify and understand material sources of loss and their origins in the device fabrication process. Through multi-institution efforts within SQMS we have identified the loss mechanism of interstitial hydrogen in niobium-based devices and shown how standard fabrication processes introduce these hydrides, developing strategies to mitigate their formation.1 Furthermore, we have characterized the metal-substrate interface, including the loss of niobium-silicides formed at that interface, and developed silicon surface treatments that reduce atomic scale roughness and oxygen content at the metal-substrate and Josephson junction interfaces.2-4 By developing the connection between materials properties and the overall performance of superconducting quantum circuitry, we can develop fabrication strategies to mitigate material losses, thus supporting the ongoing efforts to enhance coherence time in superconducting quantum devices. 1. Torres-Castanedo, C. G.*, Goronzy, D. P.*, et al., Adv. Funct. Mater., 2401365 (2024) 2. Lu, X., et al., Phys. Rev. Materials 6, 064402 (2022) 3. Berti, G., Appl. Phys. Lett. 122, 192605 (2023) 4. Kopas, C. J., Goronzy, D. P., et al., arXiv:2408.02863 (2024)

Goronzy, Dominic P.↗

Self-reported health impacts of do-it-yourself air cleaner use in a smoke-impacted community

Smoke exposure from wildfires or residential wood burning for heat is a public health problem for many communities. Do-It-Yourself (DIY) portable air cleaners (PACs) are promoted as affordable alternatives to commercial PACs, but evidence of their effect on health outcomes is limited. Pilot test an evaluation of the effect of DIY PAC usage on self-reported symptoms, and investigate barriers and facilitators of PAC use, among members of a tribal community that routinely experiences elevated concentrations of fine particulate matter (PM 2.5 ) from smoke. We conducted studies in Fall 2021 (“wildfire study”; N = 10) and Winter 2022 (“wood stove study”; N = 17). Each study included four sequential one-to-two-week phases: 1) initial, 2) DIY PAC usage ≥8 h/day, 3) commercial PAC usage ≥8 h/day, and 4) air sensor with visual display and optional PAC use. We continuously monitored PAC usage and indoor/outdoor PM 2.5 concentrations in homes. Concluding each phase, we conducted phone surveys about participants’ symptoms, perceptions, and behaviors. We analyzed symptoms associated with PAC usage and conducted an analysis of indoor PM 2.5 concentrations as a mediating pathway using mixed effects multivariate linear regression. We categorized perceptions related to PACs into barriers and facilitators of use. No association was observed between PAC usage and symptoms, and the mediation analysis did not indicate that small observed trends were attributable to changes in indoor PM 2.5 concentrations. Small sample sizes hindered the ability to draw conclusions regarding the presence or absence of causal associations. DIY PAC usage was low; loud operating noise was a barrier to use. This research is novel in studying health effects of DIY PACs during wildfire and wood smoke exposures. Such research is needed to inform public health guidance. Recommendations for future studies on PAC use during smoke exposure include building flexibility of intervention timing into the study design.

54 ENVIRONMENTAL SCIENCES↗

Effect of Gamma Radiation on TaOₓ ECRAM

Electrochemical random access memory (ECRAM) is an emerging three-terminal nonvolatile memory (NVM) with highly controllable channel conductance which is promising for use as an analog memory (or synapse) in analog in-memory computing (IMC) systems. Energy-efficient analog IMC computing is particularly desirable for power-constrained, high-radiation environments such as satellites. However, little is known about the suitability of ECRAM for use in a total ionizing dose (TID) environment. Here, this work investigates the effect of Co-60 gamma radiation on the channel conductance and noise—two properties critical for analog IMC systems—of a TaO x -based ECRAM up to 17.3 Mrad(SiO 2 ) for both low- and high-channel-conductance state devices. A transient increase in conductance is observed in response to radiation which consists of two elements: an immediate increase in conductivity due to photocurrent and a secondary increase in conductivity, which has a slower rise and saturation and can persist for hours after exposure. This secondary, persistent photoconductivity is attributed to charging caused by hole trapping. These transient effects would not likely occur in a space environment due to the low dose rate compared with this experiment. No permanent change is found in the low conductance state (LCS) following exposure and the minor shift in the high conductance change would be less significant than the regular retention decay in this state. A permanent increase in the random telegraph noise is observed, possibly due to increased traps created in the channel. This work demonstrates that TaO x -based ECRAM is suitable for use in spaceborne analog IMC systems that are subject to significant TID.

ECRAM↗

Mixed gain detector configurations for time-resolved X-ray solution scattering

X-ray detection at X-ray free-electron lasers is challenging in part due to the XFEL's extremely short and intense X-ray pulses. Experimental measurements are further complicated by the large fluctuations inherent to the self-amplified spontaneous emission process producing the X-rays. At the Linac Coherent Light Source the ePix10ka2M detector offers multiple gain modes, and auto-ranging between these, to increase the dynamic range while retaining low noise. For diffuse scattering techniques, such as time-resolved X-ray solution scattering, where the shape of the scattering pattern largely does not change between exposures, a fixed mix of different gain modes offers many of the same advantages as auto-ranging. We find that configuring individual ASICs in separate gain modes does not impact the intensity linearity of the gain response and has a limited effect on the effective dynamic range in regions with different gain mode settings while avoiding the complexities of auto-ranging. Small (<5%) non-linear gain contributions arise when pixels on the same ASIC are configured in different gain modes. We present a configuration scheme that is designed to select the optimal mixed gain configuration to minimize effects of saturation in the high-/medium-gain region, while maximizing the number of pixels with higher gain to improve the signal-to-noise ratio.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigation of ASIC-based signal readout electronics for LEGEND-1000

LEGEND, the Large Enriched Germanium Experiment for Neutrinoless ββ Decay, is a ton-scale experimental program to search for neutrinoless double beta (0νββ) decay in the isotope 76 Ge with an unprecedented sensitivity. Building on the success of the low-background 76 Ge-based GERDA and Majorana Demonstrator experiments, the LEGEND collaboration is targeting a signal discovery sensitivity beyond 10 28 yr on the decay half-life with approximately 10 t∙yr of exposure. Signal readout electronics in close proximity to the detectors plays a major role in maximizing the experiment's discovery sensitivity by reducing electronic noise and improving pulse shape analysis capabilities for the rejection of backgrounds. However, the proximity also poses unique challenges for the radiopurity of the electronics. Application-specific integrated circuit (ASIC) technology allows the implementation of the entire charge sensitive amplifier (CSA) into a single low-mass chip while improving the electronic noise and reducing the power consumption. In this work, we investigated the properties and electronic performance of a commercially available ASIC CSA, the XGLab CUBE preamplifier, together with a p-type point contact high-purity germanium detector. We show that low noise levels and excellent energy resolutions can be obtained with this readout. Moreover, we demonstrate the viability of pulse shape discrimination techniques for reducing background events.

47 OTHER INSTRUMENTATION↗

Prevalence of Self-Reported Voice Concerns and Associated Risk Markers in a Nonclinical Sample of Military Service Members

Introduction: Difficult communication environments are common in military settings, and effective voice use can be critical to mission success. This study aimed to estimate the prevalence of self-reported voice disorders among U.S. military service members and to identify factors that contribute to their voice concerns. Method: A nonclinical sample of 4,123 active-duty service members was recruited across Department of Defense hearing conservation clinics. During their required annual hearing evaluation, volunteers provided responses to voice-related questions including a slightly adapted version of the Voice Handicap Index-10 (VHI-10) as part of a larger survey about communication issues. Changepoint detection was applied to age and years of service to explore cohort effects in the reporting of voice concerns. Logistic regression analyses examined multiple available factors related to communication to identify factors associated with abnormal results on the VHI-10. Results: Among the respondents, 41% reported experiencing vocal hoarseness or fatigue at least several times per year, and 8.2% ( n = 336) scored above the recommended abnormal cut-point value of 11 on the VHI-10. Factors independently associated with the greatest risk for self-reported voice concerns were sex (female), cadmium exposure, vocal demands (the need for a strong, clear voice), and auditory health measures (frequency of experiencing temporary threshold shifts; self-reported hearing difficulties). Conclusions: Based on self-reported voice concerns and false negative rates reported in the literature, the prevalence of dysphonia in a large sample of active-duty service members is estimated to be 11.7%, which is higher than that in the general population. Certain predictors for voice concerns were expected based on previous literature, like female sex and voice use, but frequency of temporary threshold shifts and exposure to cadmium were surprising. The strong link between voice and auditory problems has particular implications regarding the need for effective communication in high-noise military and other occupational environments.

Audiology & Speech-Language Pathology↗