Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “noble gas”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

The MSFC Noble Gas Research Laboratory (MNGRL): A NASA Investigator Facility

Noble-gas isotopes are a well-established technique for providing detailed temperature-time histories of rocks and meteorites. We have established the MSFC Noble Gas Research Laboratory (MNGRL) at Marshall Space Flight Center to serve as a NASA investigator facility in the wake of the closure of the JSC laboratory formerly run by Don Bogard. The MNGRL lab was constructed to be able to measure all the noble gases, particularly Ar-Ar and I-Xe radioactive dating to find the formation age of rocks and meteorites, and Ar/Kr/Ne cosmic-ray exposure ages to understand when the meteorites were launched from their parent planets.

noble gas↗

Noble Gas Analysis for Mars Robotic Missions: Evaluating K-Ar Age Dating for Mars Rock Analogs and Martian Shergottites

The purpose of this noble gas investigation was to evaluate the possibility of measuring noble gases in martian rocks and air by future robotic missions such as the Mars Science Laboratory (MSL). The MSL mission has, as part of its payload, the Sample Analysis at Mars (SAM) instrument, which consists of a pyrolysis oven integrated with a GCMS. The MSL SAM instrument has the capability to measure noble gas compositions of martian rocks and atmosphere. Here we suggest the possibility of K-Ar age dating based on noble gas release of martian rocks by conducting laboratory simulation experiments on terrestrial basalts and martian meteorites. We provide requirements for the SAM instrument to obtain adequate noble gas abundances and compositions within the current SAM instrumental operating conditions, especially, a power limit that prevents heating the furnace above approx.1100 C. In addition, Martian meteorite analyses from NASA-JSC will be used as ground truth to evaluate the feasibility of robotic experiments to constrain the ages of martian surface rocks.

Park, J.↗

Biomedical Investigations with Laser-Polarized Noble Gas Magnetic Resonance

We pursued advanced technology development of laser-polarized noble gas nuclear magnetic resonance (NMR) as a novel biomedical imaging tool for ground-based and eventually space-based application. This new multidisciplinary technology enables high-resolution gas-space magnetic resonance imaging (MRI)-e.g., of lung ventilation-as well as studies of tissue perfusion. In addition, laser-polarized noble gases (3He and 129Xe) do not require a large magnetic field for sensitive detection, opening the door to practical MRI at very low magnetic fields with an open, lightweight, and low-power device. We pursued two technology development specific aims: (1) development of low-field (less than 0.01 T) noble gas MRI of humans; and (2) development of functional MRI of the lung using laser-polarized noble gas and related techniques.

Walsworth, Ronald L.↗

On the presolar origin of the 'normal planetary' noble gas component in meteorites

Several components of planetary noble gases, including CCFXe (Xe-X), s-process Kr and Xe, and Ne-E, are now thought to have had a presolar origin. It is proposed that the 'normal planetary' noble gas component, which contains most of the planetary Ar, Kr, and Xe, is also presolar. This component was trapped in carbonaceous mantles as the mantles formed on grain surfaces in the molecular cloud. The presolar dust grains and their carbonaceous mantles were then incorporated into primitive meteorites. This model naturally explains: (1) the affinity of 'normal planetary' noble gases for carbonaceous material in primitive chondrites; (2) the near absence of He and Ne in the 'normal planetary' component; (3) the elemental fractionation patterns of the 'exotic' and 'normal planetary' components; (4) the similarity of the isotopic compositions of 'normal planetary' and trapped solar Ar, Kr, and Xe; (5) the high noble gas content of the 'normal planetary' gas carrier; (6) several aspects of the chemistry of the 'normal planetary' gas carrier; (7) the correlation of planetary noble gases with the fine-grained material in primitive chondrites; and (8) the widespread occurrence of the planetary fractionation pattern throughout the solar system.

Huss, Gary R.↗

Short-lived noble gas effluent trends from a research reactor

An understanding of anthropogenic sources of radioactive noble gases in the atmosphere is needed to enhance the discrimination ability of the International Monitoring System's sensors. These sources include commercial and research nuclear reactors and medical isotope production facilities. While abiding by local environmental ordinances these facilities all emit noble gas radioisotopes through normal operation. Here, this research presents measurements and analysis of noble gas isotopes ( 41 Ar, 135 Xe, 135m Xe, 137 Xe, 138 Xe, 87 Kr, 88 Kr, and 89 Kr) made directly at the stack of the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory. The Xe and Kr noble gases are concurrently observed with 41 Ar, a neutron activation product, when the reactor is operational. The magnitude of the Xe and Kr noble gases released is not constant over the HFIR cycle, but they temporally match the 41 Ar trend. An isotope activity ratio analysis of these shorter lived isotopes combined with the observation of the cycle's temporal trend helps understand the noble gas production mechanism at the HFIR. Isotopes with short half-lives are not useful for long-range environmental monitoring. However, these measurements could potentially be combined with atmospheric modeling to predict the background source term of the longer-lived Xe ratios at a monitoring station.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Genesis Noble Gas Measurements

The original thrust of our Genesis funding was to extend and refine the noble gas analytical capabilities of this laboratory to improve the precision and accuracy of noble gas measurements in order to optimize the scientific return from the Genesis Mission. This process involved both instrumental improvement (supplemented by a SRLIDAP instrument grant) and refinement of technique. The Genesis landing mishap shifted our emphasis to the irregular aluminum heat shield material from the flat collector wafers. This has required redesign of our laser extraction cells to accommodate the longer focal lengths required for laser extraction from non-flat surfaces. Extraction of noble gases from solid aluminum surfaces, rather than thin coatings on transparent substrates has required refinement of controlled-depth laser ablation techniques. Both of these bring new problems, both with potentially higher blanks form larger laser cells and the larger quantities of evaporated aluminum which can coat the sapphire entrance ports. This is mainly a problem for the heavy noble gases where larger extraction areas are required, necessitating the new aluminum vapor containment techniques described below. With the Genesis Mission came three new multiple multiplier noble gas mass spectrometers to this laboratory, one built solely by us (Supergnome-M), one built in collaboration with Nu-Instruments (Noblesse), and one built in collaboration with GVI (Helix). All of these have multiple multiplier detection sections with the Nu-Instruments using a pair of electrostatic quad lenses for isotope spacing and the other two using mechanically adjustable positions for the electron multipliers. The Supergnome-M and Noblesse are installed and running. The GVI instrument was delivered a year late (in March 2005) and is yet to be installed by GVI. As with all new instruments there were some initial development issues, some of which are still outstanding. The most serious of these are performance issues with the miniature channel electron multipliers. The delayed installation of Helix by the GVI is partly due to failure of the initial batch of Burle channel multipliers to perform as expected. A number of the channel multipliers designed for Noblesse by Burle have also failed upon baking. Burle has now refined the design of these and we have installed two of the new multipliers and are assessing their performance. The remaining multipliers Will be upgraded to the new design from Burle once we confirm that the problem has been fixed.

Hohenberg, Charles M.↗

Optimal strategies for optical quantum memories using long-lived noble-gas spins

Nuclear spins of noble gases exhibit exceptionally long coherence times and can potentially serve as a long-lived storage medium for quantum information. We analyze and compare the performance of two mechanisms for mapping the quantum state of light onto the collective spin state of noble gases. The first mechanism utilizes collisional exchange with the electronic spin state of metastable noble-gas atoms, while the second relies on spin-exchange collisions with ground-state alkali-metal atoms. We describe the operation of an optical quantum memory relying on these two mechanisms using a compact model and study strategies that optimize the memory storage efficiency. Through numerical simulations, we identify optimal sequences for storing optical signals with different signal bandwidths and electronic spin relaxation rates. This work highlights the qualitative difference between the two approaches for using noble gases as long-lived quantum memories at noncryogenic conditions and outlines the regimes in which they are expected to be efficient.

atomic ensemble↗

A review of noble gas geochemistry in relation to early Earth history

One of the most fundamental noble gas constraints on early Earth history is derived from isotopic differences in (129)Xe/(130)Xe between various terrestrial materials. The short half life (17 m.y.) of extinct (129I, parent of (129)Xe, means that these differences must have been produced within the first 100 m.y. after terrestrial accretion. The identification of large anomalies in (129)Xe/(130)Xe in mid ocean ridge basalts (MORB), with respect to atmospheric xenon, suggests that the atmosphere and upper mantle have remained separate since that time. This alone is a very strong argument for early catastrophic degassing, which would be consistent with an early fractionation resulting in core formation. However, noble gas isotopic systematics of oceanic basalts show that the mantle cannot necessarily be regarded as a homogeneous system, since there are significant variations in (3)He/(4)He, (40)Ar/(36)Ar, and (129)Xe/(130)Xe. Therefore, the early degassing cannot be considered to have acted on the whole mantle. The specific mechanisms of degassing, in particular the thickness and growth of the early crust, is an important variable in understanding present day noble gas inventories. Another constraint can be obtained from rocks that are thought to be derived from near the lithosphere asthenosphere boundary: ultramafic xenoliths.

Kurz, M. D.↗

Solubility of noble gases in serpentine - Implications for meteoritic noble gas abundances

An investigation of the solubilities of the noble gases from synthesis and solubility studies of the sheet silicate mineral serpentine in carbonaceous chondrites is presented. Hydrothermal synthesis and exchange experiments were made at 340C and 1 kbar with noble gas partial pressures from 2 times 10 to the -8th power to 0.1 atm. The measured distribution coefficients for noble gases are not sufficiently high to account for the trapped noble gases in carbonaceous chondrites by exchange in solar nebula if meteoritic minerals have comparable distribution coefficients. Also, serpentine gains and loses noble gases to approach equilibrium values with the terrestrial atmosphere, indicating that this exposure may have influenced the noble gas abundances in phyllosilicate minerals of these chondrites. The dispersion of K-Ar ages of carbonaceous chondrites could be the result of phyllosilicates approaching equilibrium solubility of atmospheric Ar-40.

Zaikowski, A.↗

Biomedical Investigations with Laser-Polarized Noble Gas Magnetic Resonance

We are developing laser-polarized noble gas nuclear magnetic resonance (NMR) as a novel biomedical imaging tool for ground-based and eventually space-based application. This emerging multidisciplinary technology enables high-resolution gas-space magnetic resonance imaging (MRI) (e.g., of lung ventilation) as well as studies of tissue perfusion. In addition, laser-polarized noble gases (He-3 and Xe-129) do not require a large magnetic field for sensitive detection, opening the door to practical MRI at very low magnetic fields with an open, lightweight, and low-power device. We are pursuing two specific aims in this research. The first aim is to develop a low-field (< 0.01 T) instrument for noble gas MRI of humans, and the second aim is to develop functional MRI of the lung using laser-polarized Xe-129 and related techniques.

Walsworth, Ronald L.↗

Using groundwater noble gas measurements to confirm paleorecharge hypotheses at Pahute Mesa, Nevada National Security Site, Nevada, USA

Pahute Mesa (Nevada, USA) was the site of 85 underground nuclear tests between 1965 and 1992 whose residual radio-chemical inventory poses a contaminant threat to local groundwater resources. To assess the fate and transport of these radionuclides in groundwater, several geochemical studies, including this one, have been conducted to understand long-term groundwater flow patterns at, and downgradient of, Pahute Mesa. Groundwater samples from the Pahute Mesa area at the Nevada National Security Site were analyzed for noble gases ( 3 He/ 4 He isotopic ratio and He, Ne, Kr, Ar and Xe concentrations) to infer groundwater recharge temperatures and provide additional evidence in support of groundwater flow patterns and the presence of late-pluvial Pleistocene groundwater. These data confirm recent findings (based on groundwater geochemistry and isotope compositions) that most recharge in the area occurred under temperature conditions much cooler than are found today, except near major drainages where ephemeral run of continues to recharge shallow groundwater. These noble gas data indicate that noble gas recharge temperatures and terrigenic He components have been reset where groundwater has flowed upward over barriers formed by caldera margins, or near the regional discharge area (Oasis Valley) where shallow groundwater has interacted with shallow soil gas. This evidence from groundwater noble gas measurements, in combination with other isotopic and geochemical studies, supports the current understanding of the unusual hydrogeology and recharge history of Pahute Mesa.

54 ENVIRONMENTAL SCIENCES↗

Signal-to-noise ratio comparison of encoding methods for hyperpolarized noble gas MRI

Some non-Fourier encoding methods such as wavelet and direct encoding use spatially localized bases. The spatial localization feature of these methods enables optimized encoding for improved spatial and temporal resolution during dynamically adaptive MR imaging. These spatially localized bases, however, have inherently reduced image signal-to-noise ratio compared with Fourier or Hadamad encoding for proton imaging. Hyperpolarized noble gases, on the other hand, have quite different MR properties compared to proton, primarily the nonrenewability of the signal. It could be expected, therefore, that the characteristics of image SNR with respect to encoding method will also be very different from hyperpolarized noble gas MRI compared to proton MRI. In this article, hyperpolarized noble gas image SNRs of different encoding methods are compared theoretically using a matrix description of the encoding process. It is shown that image SNR for hyperpolarized noble gas imaging is maximized for any orthonormal encoding method. Methods are then proposed for designing RF pulses to achieve normalized encoding profiles using Fourier, Hadamard, wavelet, and direct encoding methods for hyperpolarized noble gases. Theoretical results are confirmed with hyperpolarized noble gas MRI experiments. Copyright 2001 Academic Press.

Non-NASA Center↗

Examining the potential for detecting simultaneous noble gas and aerosol samples in the international monitoring system radionuclide network

The purpose of the Comprehensive Nuclear-Test-Ban Treaty (CTBT) is to establish a legally binding ban on nuclear weapon test explosions or any other nuclear explosions. The Preparatory Commission for the CTBT Organization (CTBTO PrepCom) is developing the International Monitoring System (IMS) that includes a global network of 80 stations to monitor for airborne radionuclides upon entry into force of the CTBT. All 80 radionuclide stations will monitor for particulate radionuclides and at least half of the stations will monitor for radioxenon. The airborne radionuclide monitoring is an important verification technology both for the detection of a radionuclide release and in the determination of whether the release event originates from a nuclear explosion as opposed to an industrial use of nuclear materials. Nuclear power plants and many medical isotope production facilities release radioxenon into the atmosphere. Low levels of a few particulate isotopes, such as iodine, may also be released. Detections of multiple isotopes are useful for screening the radionuclide samples for relevance to the Treaty. This paper examines the anticipated joint detections in the IMS of noble gas and particulate isotopes from underground nuclear explosions where breaches in the underground containment vents from low levels to up to 1% of the radionuclide inventory of the resulting fission products to the atmosphere. Detection probabilities are based on 844 simulated release events spaced out at 17 release locations and one year in time. Six different release (venting) scenarios, including two fractionated scenarios, were analyzed. When ranked by detection probability, 11 particulate isotopes and one noble gas isotope ( 133 Xe) appear in the top 20 isotopes for all six release scenarios. Using the 11 particulate isotopes and the one noble gas isotope, the IMS has nearly the same detection probability as when 45 particulate and 4 noble gas isotopes are used. Thus, a limited list of relevant radionuclides may be sufficient for treaty verification purposes. The probability that at least one particulate and at least one radioxenon isotope would be detected in the IMS from the release events ranged from 0.15 to 0.86 depending on the release scenario.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Quantum-chemical modeling of boron and noble gas dopants in silicon

The electron effects of the presence of boron and noble gas dopants in a model silicon lattice were investigated using a self-consistent charge extended Hueckel program. The extent of electronic interaction of the noble gas with the lattice is given by: Kr greater than Ar greater than Ne. Theoretically, boron diffusion in the presence of neon, argon or krypton was examined using a self-consistent charge extended Hueckel program. The net energy of interaction between boron and neon is strongly repulsive while argon-boron exhibits a region of relative stability; krypton exhibits behavior similar to argon though no region of stability was found for the range of separations used in the calculations. Finally, it is noted, from the relative energy of the topmost filled molecular orbital associated with boron (in an interstitial position), that activation of the boron does not require boron movement but can be accomplished by indirect transitions.

Aronowitz, S.↗

Planetary noble gas components in Orgueil

In the reported investigation, the approach employed by Jeffery and Anders (1970) and Eberhardt (1974), who used colloidal suspensions in separating minerals of the Orgueil carbonaceous chondrite (C1), was extended to an application involving the enrichment of a planetary noble gas carrier in several C1 and C2 meteorites. The thermal release pattern of Orgueil 'carbon' is considered, taking into account elemental effects, a comparison of noble gas release from 'carbon' separates and bulk meteorite samples, isotopic effects, and a comparison with Murray 'carbon'. An evaluation is conducted of the noble gas components in carbonaceous chondrites. The origin of primordial noble gases in carbonaceous chondrites is also discussed, giving attention to the origin of solar gases, the role of 'carbon' as the novel vehicle for planetary gases, and plausible astrophysical sites for the production of anomalous krypton and xenon.

Frick, U.↗

133Xe Noble Gas Mass Spectrometry Measurement for High Purity Germanium Detector Performance Verification

Idaho National Laboratory produces quality control standards for laboratories that operate xenon radionuclide monitoring systems. Activities reported with each quality control standard are quantified using high purity germanium detectors. A collection of measurement capabilities are being set up at Idaho National Laboratory to establish an in-house high purity germanium detector performance verification system, with noble gas mass spectrometry being one of these measurement capabilities. The first noble gas mass spectrometry and high purity germanium measurement comparison is presented here. A Xe-133 gas sample was prepared and the activity was quantified with high purity germanium detectors. The Xe-133 sample was diluted with a known quantity of isotopically enriched Xe-126 gas; the resulting Xe-133 : Xe-126 atom ratio was calculated to be 1.15x10-4 +/- 2% at reference time t. An aliquot of this gas sample containing approximately 10 million Xe-133 atoms was introduced into a ThermoFisher Scientific Helix MC Plus noble gas mass spectrometer for analysis. The measured Xe-133 : Xe-126 atom ratio was determined to be 1.10x10-4 +/- 2% (1-sigma uncertainty) at reference time t, about 4.3% lower than the atom ratio determined with the measured high purity germanium activity.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Noble gas studies on grain size separates of Apollo 15 and 16 deep drill cores

A description is presented of noble gas analyses of grain-size separates of eight Apollo 15 drill-core samples over the depth range 2-80 cm. Noble gas data on grain-size separates of seven Apollo 16 drill-core samples are also reported. On the basis of the obtained results it is suggested that cosmogenic Ne and He in the Apollo 15 core material has been preferentially lost relative to cosmogenic Ar in the Apollo 15 core material in proportion to soil maturity and degree of solar irradiation. A plot of He-4/Ne-20 against Ar-40/Ar-36 demonstrates that material in the lowest 35 cm of the Apollo 16 drill core is distinct from all other analyzed samples in the core, and distinct from nearly all surface soils.

Bogard, D. D.↗