At least 37 records · Page 2

Research Reactors Division Infrastructure Investment Plan for the High Flux Isotope Reactor

The High Flux Isotope Reactor (HFIR) is a unique national asset. Operational for nearly 60 years, continued investment into the aging infrastructure is necessary to ensure operation for another 6 decades. Additionally, growing missions require HFIR as well as important upgrades. Consequently, carefully integrated planning is required to ensure that infrastructure investments are timely executed to ensure long-term, reliable operation of HFIR. Concerns about challenges to the operational reliability of HFIR resulted in a recommendation from the 2023 Operations Review by the US Department of Energy (DOE) Office of Basic Energy Sciences that a HFIR management strategy be developed to address the infrastructure needs. This report defines the investment needs, which are evolving as new upgrade efforts are better defined. HFIR is part of the three-source strategy within the Neutron Sciences Directorate (NScD) and contributes to the five strategic science areas outlined in the NScD 10 Year Strategic Science Plan: quantum materials, soft matter, materials and engineering, chemistry, and biosciences. Fundamental to this strategy are three core values: operational excellence, responsible stewardship, and servant leadership. These values guide our mission of safe and reliable operation of the reactor and require a strong and just nuclear safety culture, a solemn respect for responsible care of the facility, good workforce development, robust procedures and processes, an effective communication strategy, world-class asset management, a determined customer focus, and a commitment to protecting the environment, the safety and health of the public and our people, and the quality of work performed within our facility. These principles are all essential to operate HFIR at a world-class level. The Research Reactors Division (RRD) will lead a new era of neutron science and isotope production at HFIR through responsible and purposeful leadership and unwavering support of the science community. The approach outlined in this plan highlights the direction leadership is taking to ensure that HFIR is ready to support the science challenges and national needs of the future and that the United States maintains world leadership in neutron sciences. The plan is in alignment with the DOE’s desire to continue operating HFIR and with the NScD strategic science goals for the future. HFIR is an aging facility with numerous infrastructure challenges and needs. It has an aging workforce in relation to the general population of Oak Ridge National Laboratory (ORNL), with many expected retirements over the next 5–10 years. With an increase in work scope caused by changing national priorities and science goals, several critical hires have been identified. To manage HFIR’s infrastructure needs, a prioritized list of equipment upgrades has been identified along with an analysis of future staffing requirements. A desire to operate HFIR at eight cycles per year will necessarily require some significant changes to procedures and processes currently in place as well as targeted staffing additions. Many of the equipment upgrades identified in this plan will significantly increase the reliability of the plant, thus contributing to the effort to reach the goal of safely operating eight cycles per year. A plan to attain eight-cycle operation is being prepared in parallel with the activities identified in this plan, although the actions identified to satisfy both plans will overlap. This plan identifies new infrastructure needs—for both plant equipment and staffing—thus necessitating formulation of future budget requests to fund the increased work scope and improvement activities. Some activities are currently being scheduled with the expectation that funding will be received. Any delays to funding or reductions of funding from the identified cost estimations will directly and negatively affect the plan’s implementation.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Reactor Performance Improvement Options to Sustain High Flux Isotope Reactor Leadership into the Future

The mission of the Neutron Sciences Directorate (NScD) at the U.S. Department of Energy’s Oak Ridge National Laboratory (ORNL) is the undertaking of high-impact research into the structure and properties of materials across the spectrum of biology, chemistry, physics, materials science, and engineering. NScD operates two world-leading neutron scattering facilities including the High Flux Isotope Reactor (HFIR) and the Spallation Neutron Source. HFIR achieved full power in 1966, and over a half century later, it continues to serve a variety of national missions. HFIR provides one of the highest steady-state neutron fluxes of any research reactor in the world to support scientific missions including cold and thermal neutron scattering, isotope production, and materials irradiation research. To sustain leadership in neutron sciences into the future, ORNL is exploring areas in which HFIR can be improved to enhance its performance. Many improvement areas are being explored such as upgrading the cold source and neutron scattering facilities; however, the improvement areas focused on in this paper include replacing the reactor pressure vessel, upgrading the neutron reflector, and converting from high-enriched uranium to low-enriched uranium fuel.

Chandler, David↗

The Mini-CAPTAIN liquid argon time projection chamber

This manuscript describes the commissioning of the Mini-CAPTAIN liquid argon detector in a neutron beam at the Los Alamos Neutron Science Center (LANSCE), which led to a first measurement of high-energy neutron interactions in argon. The Mini-CAPTAIN detector consists of a Time Projection Chamber (TPC) with an accompanying photomultiplier tube (PMT) array sealed inside a liquid-argon-filled cryostat. The liquid argon is constantly purified and recirculated in a closed-loop cycle during operation. The specifications and assembly of the detector subsystems and an overview of their performance in a neutron beam are reported.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of charged-particle emission in neutron reactions on 10 B

The 10 B + n system has been studied by measuring charged particles from neutron-induced reactions in the 1 to 20 MeV energy range. Protons, deuterons, tritons, and α particles were measured at four angles using the pulsed white neutron spectrum at the Los Alamos Neutron Science Center Weapons Neutron Research facility. Differential cross sections for each species are reported. These new data are combined with literature data in an R-matrix analysis of the 11 B compound system. Furthermore, a comparison is made to the molecular and cluster states candidates observed in these reactions.

43 PARTICLE ACCELERATORS↗

Development of a High-Energy Neutron Sniffer and Subsequent Dose Quantification for High-Energy Particle Accelerator Shielding Surveys

The objective of this research is to design a portable neutron detector that is lightweight and responds to neutrons with energies of 20 MeV and greater. The instrument will be used as a ‘sniffer’ probe for identifying shielding weaknesses at high-energy particle accelerators and be paired with a plastic scintillator to quantify the high-energy neutron dose equivalent. The sniffer probes are two different sizes and comprised of either cesium iodide or sodium iodide, all doped with thallium, making a total of four detectors. The probes were calibrated to respond only to radiations with 8 MeV electron equivalent energy or higher, vastly reducing detector response from background and lower energy radiations. The sniffer probes were tested using californium- 252 and americium-beryllium sources, followed by high-energy (up to 800 MeV) neutron exposures at the Los Alamos Neutron Science Center Weapons Neutron Research (WNR) facility. The sniffer probes were then used to identify areas around the accelerator facility where elevated levels of high-energy radiation was present and the plastic scintillators were placed in these locations to determine the high-energy neutron dose equivalent. The dose equivalent is calculated by measuring the 12 C(n,2n) 11 C reaction, which has a 20.4 MeV neutron threshold. Two locations behind the WNR facility were identified with the probes and the dose equivalent rates from neutron energies above 20 MeV were calculated to be 1.24 mrem/h behind flightpath 30-left and 1.53 behind flightpath 30-right. Of the four sniffer probes, the 2-inch x 2-inch cesium iodide is the recommended probe for performing high-energy shielding surveys. The larger crystal size yields higher sensitivity at lower count rates and the more dense material increases the likelihood of interaction within the crystal.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-precision Measurement of the 16 O($n, n'γ$) Cross Section using $γ$-ray Detection in Liquid Scintillators with H 2 O and BeO Targets

The 16 O($n, n'γ$) reaction was measured at the Los Alamos Neutron Science Center white neutron source using γ-ray detection in liquid scintillators present in the upper hemisphere of the Correlated Gamma-Neutron Array for sCattering (CoGNAC). Separate measurements of this reaction were performed using H 2 O and BeO targets in successive years. The unique high energies of γ rays emitted from the 16 O($n, n'γ$) reaction facilitated a clean selection of this reaction from threshold to 9.8 MeV incident neutron energy without the need for precise measurements of the γ-ray energy or the scattered neutrons. The precise time resolution of the liquid scintillator detectors was then exploited to obtain high-resolution incident neutron energy measurements, and good agreement was obtained between the H 2 O and BeO results reported here. The dominant literature data sets for this reaction have systematic differences between them, but the present results improve upon the neutron energy resolution of earlier measurements and show important discrepancies in recent data. Finally, tentative data are also shown up to 20 MeV incident neutron energy but are potentially subject to improved understanding of the relative γ-ray and α decay branches from 16 O excited states.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of the prompt fission neutron spectrum from 800 keV to 10 MeV for 240 Pu(sf) and for the 240 Pu($n,f$) reaction induced by neutrons of energy from 1–20 MeV

Here, the presence of 240 Pu in nuclear fuels for reactors has resulted in high uncertainties in the results of reactor and nuclear transmutation calculations because of deficiencies in 240 Pu-related nuclear data. Specifically for the prompt fission neutron spectrum (PFNS) of 240 Pu, there is only one neutron-induced, (n,f), measurement at 0.85 MeV incident neutron energy and only one complete spontaneous fission, (sf), measurement. This limited availability of data does not sufficiently guide nuclear data evaluations of these quantities. Here we report on a measurement of both the 240 Pu(sf) and the 240 Pu(n,f) PFNS, both over the emitted neutron energy range of 0.79–10.0 MeV, and from incident neutron energies of 1.0–20.0 MeV for the (n,f) reaction. Measurements were made with a hemispherical array of liquid scintillators at the high-energy Los Alamos Neutron Science Center white neutron source at the Weapons Neutron Research facility as part of the joint LANL-LLNL Chi-Nu experimental campaign to measure actinide fission neutron spectra. These measurements are the first of their kind, and provide clear experimental evidence for second-chance fission, third chance fission, and pre-equilibrium neutron emission processes in neutron-induced fission of 240 Pu, and are the first ever measurements above 1 MeV incident neutron energy.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of the Prompt Fission Neutron Spectrum from 800 keV to 10 MeV for 240 Pu($sf$) and for the 240 Pu($n,f$) Reaction Induced by Neutrons of Energy from 1-20 MeV

The presence of 240 Pu in nuclear fuels for reactors has resulted in high uncertainties in the results of reactor and nuclear transmutation calculations because of deficiencies in 240 Pu-related nuclear data. Specifically for the prompt fission neutron spectrum (PFNS) of 240 Pu, there is only one neutron-induced, ($n,f$), measurement at 0.85 MeV incident neutron energy and only one complete spontaneous fission, ($sf$), measurement. This limited availability of data does not sufficiently guide nuclear data evaluations of these quantities. Here we report on a measurement of both the 240 Pu($sf$) and the 240 Pu($n,f$) PFNS, both over the emitted neutron energy range of 0.79–10.0 MeV, and from incident neutron energies of 1.0–20.0 MeV for the ($n,f$) reaction. Measurements were made with a hemispherical array of liquid scintillators at the high-energy Los Alamos Neutron Science Center white neutron source at the Weapons Neutron Research facility as part of the joint LANL-LLNL Chi-Nu experimental campaign to measure actinide fission neutron spectra. These measurements are the first of their kind, and provide clear experimental evidence for second-chance fission, third-chance fission, and pre-equilibrium neutron emission processes in neutron-induced fission of 240 Pu, and are the first ever measurements above 1 MeV incident neutron energy.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Resilient GaN-based Power Module with Improved Diagnostic for Future Accelerator

Los Alamos Neutron Science Center (LANSCE) and Dual-Axis Radiographic Hydrodynamic Test facility (DARHT) play a pivotal role in advancing scientific research and national security initiatives. As a premier facility for neutron science, LANSCE and DARHT provide invaluable insights into fundamental research, materials science, nuclear physics, high-energy physics, material science, and medical imaging. Existing (DC) power supply and pulse modulation technologies used in LANSCE and DARHT face limitations in terms of reliability, maintainability, and diagnostics which hinder the progress of these cutting-edge facilities. By proposing improvements to LANL accelerator facilities’ performance and addressing component failure, we aim to enhance scientific outcomes and minimize disruptions, allowing for more efficient and productive research activities while ensuring the continuity of valuable contributions to the user community. This proposal aims to revolutionize (DC) power supply and pulse power systems for future particle accelerators via the development of a resilient GaN-based power module with improved diagnostic and redundant submodules.

43 PARTICLE ACCELERATORS↗

Improving Longitudinal Impedance of Inductive Inserts

In this article, we discuss methods for improving the longitudinal impedance of inductive inserts used for space charge compensation in the proton storage ring (PSR) at Los Alamos Neutron Science Center (LANSCE) Facility. The PSR relies on inductive inserts to counteract the capacitive impedance produced by the space charge of the proton beam, which can otherwise lead to beam debunching. Existing inductive inserts, which utilize Toshiba M4C21A ferrite, have been effective but require heating to reduce resistive components that can cause instabilities at higher frequencies. This article explores the potential of alternative ferrite materials, specifically National Magnetics C2050, to enhance the performance of these inserts by reducing the need for heating and minimizing resistive impedance. Through both analytical modeling and CST Particle Studio simulations, it is demonstrated that optimized ferrite materials and geometries can significantly improve space charge compensation while mitigating instability risks, ultimately enhancing the performance of the PSR.

43 PARTICLE ACCELERATORS↗

Efficient Data Management in Neutron Scattering Data Reduction Workflows at ORNL

Oak Ridge National Laboratory (ORNL) experimental neutron science facilities produce 1.2 TB a day of raw event-based data that is stored using the standard metadata-rich NeXus schema built on top of the HDF5 file format. Performance of several data reduction workflows is largely determined by the amount of time spent on the loading and processing algorithms in Mantid, an open-source data analysis framework used across several neutron sciences facilities around the world. The present work introduces new data management algorithms to address identified input output (I/O) bottlenecks on Mantid. First, we introduce an in-memory binary-tree metadata index that resemble NeXus data access patterns to provide a scalable search and extraction mechanism. Second, data encapsulation in Mantid algorithms is optimally redesigned to reduce the total compute and memory runtime footprint associated with metadata I/O reconstruction tasks. Results from this work show speed ups in wall-clock time on ORNL data reduction workflows, ranging from 11% to 30% depending on the complexity of the targeted instrument-specific data. Nevertheless, we highlight the need for more research to address reduction challenges as experimental data volumes increase.

Godoy, William↗

Negative hydrogen ion sources for particle accelerators: Sustainability issues and recent improvements in long-term operations

High brightness, negative hydrogen ion sources are used extensively in scientific facilities operating worldwide. Negative hydrogen beams have become the preferred means of filling circular accelerators and storage rings as well as enabling efficient extraction from cyclotrons. Several well-known facilities now have considerable experience with operating a variety of sources such as RF-, filament-, magnetron- and Penning-type H- ion sources. These facilities include the US Spallation Neutron Source (SNS), Japan Proton Accelerator Research Complex (J-PARC), Rutherford Appleton Laboratory (RAL-ISIS), Los Alamos Neutron Science Center (LANSCE), Fermi National Accelerator Laboratory (FNAL), Brookhaven National Laboratory (BNL), numerous installations of D-Pace (licenced by TRIUMF) ion sources used mainly on cyclotrons and, most recently, the CERN-LINAC-1 injector. This report first summarizes the current performance of these ion sources in routine, daily operations with attention toward source service-periods and availability metrics. Sustainability issues encountered at each facility are also reported and categorized to identify areas of common concern and key issues. Recent ion source improvements to address these issues are also discussed as well as plans for meeting future facility upgrade requirements.

Welton, Robert F.↗

Measurement of the 240 Pu(n,f) Prompt Fission Neutron Spectra with Chi-Nu

The DOE Nuclear Criticality Safety Program has funded a multi-year effort to measure the 240 Pu(n,f) Prompt Fission Neutron Spectrum at Chi-Nu. This project is a joint LANL-LLNL effort, involving the preparation of 12 240 Pu foils and construction of a Parallel-Plate Avalanche Counter at LLNL, with subsequent measurements of the 240 Pu(n,f) PFNS at the Chi-Nu beamline at the Los Alamos Neutron Science Center’s Weapons Neutron Research facility (LANSCE/WNR). We expect the PPAC to be ready in time to perform the measurements this run cycle.

240Pu Foils↗

Simulation and measurement of the dynamic strain response in a prototypical spallation target

The Second Target Station (STS) at the Spallation Neutron Source (SNS) will address emerging scientific challenges by providing a source of intense cold neutrons to instruments optimized for this source. The STS target will use rotating tungsten blocks and will receive 1.3 GeV proton beam pulses from the SNS accelerator at a repetition rate of 15 Hz. The facility life is planned for 40 years, and each target assembly life is expected to be approximately 10 years. An accurate strain prediction is then critical for fatigue life assessment of STS target blocks because they will be subject to approximately 10 8 beam pulses per lifetime. As an R&D activity, the Los Alamos Neutron Science Center (LANSCE) Weapons Neutron Research (WNR) Target 2 (Blue Room) facility was used to test the strain response of prototypical target blocks to the thermal shock of a proton pulse. The blue room was well suited for a pulsed proton beam impact test of subscale STS target blocks; the 800 MeV proton energy is approximately 60 % of the 1.3 GeV proton energy expected from the SNS accelerator to the STS. The LANSCE Proton Storage Ring (PSR) and SNS are both short-pulse proton beam sources with nominal pulse widths of 250 ns and 661 ns, respectively, so the energy deposition in the target occurs in <1 μs pulse duration. Strain measurements on the outer surface of three target blocks (bare tungsten, tantalum-clad tungsten, niobium-clad tungsten) were recorded for comparison against neutronics and structural simulations. In conclusion, this experiment and the supporting simulations satisfied the following primary research goals for the STS target.

Dynamic strain response↗

Gallium oxide (Ga 2 O 3 ) energy dependent scintillation response to fast neutrons and flash gamma-rays

Gallium oxide is a newly emerged ultrawide bandgap (4.9 eV) semiconductor that is suitable as a combined electronics and radiation detection platform. We have experimentally demonstrated fast neutron and gamma-ray scintillation from Czochralski-grown β-Ga 2 O 3 in a recent series (October 2023) of experiments at the unmoderated pulsed neutron spallation source located at the Los Alamos Neutron Science Center. Using the neutron time-of-flight (TOF) technique and a fast-gated intensified CCD camera, we observed energy-dependent neutron scintillation for neutron energies ranging from 1 to 400 MeV, including the 14.1 MeV neutron energy relevant to D–T fusion. Neutron flux is quantified and calibrated by cascading the scintillator after the fission chamber, enabling a detailed analysis of temporal and energy-dependent characteristics of the scintillation events. Further, a pronounced scintillation signal from the spallation gamma flash with a temporal full width of half maximum of ~4 ns is indicative of the material’s rapid response. Neutron energy dependent scintillation is observed using the TOF method at a 22.6-m distance from the neutron source. These results highlight the possibility of developing a Ga 2 O 3 based fusion neutron diagnostic platform integrated with both scintillation and electronics functions on the integrated chip scale.

47 OTHER INSTRUMENTATION↗

γ-ray measurements in fast-neutron-induced reactions on 203 Tl

Fast-neutron-induced reactions can be used to characterize reaction mechanisms, investigate nuclear structure, and impose constraints on nuclear models. Because of the difficulty in predicting such effects, experimental data are important to constrain models. Thallium isotopes located close to the doubly magic Pb 208 nucleus are important for comparison with shell-model calculations. Study the population of excited states in Tl 203 and lighter isotopes in such reactions. Our methods are as follows. γ -ray cross sections were measured. The data were taken by using the Germanium Array for Neutron-Induced Excitations spectrometer. The pulsed neutron source of the Los Alamos Neutron Science Center's Weapons Neutron Research facility provided neutrons in the energy range from 1 to 300 MeV. The time-of-flight technique was used to determine the incident neutron energies. Cross sections for emission of several γ rays in 20 reaction channels were determined. Candidates for the intruder 9 / 2 - state in Tl 203 , from the odd proton in the h 9 / 2 orbital, and the first 5 + states in Tl 202 , 204 , from admixture of configurations, were identified. The excitation energy of the candidate 9 / 2 - , π h 9 / 2 state is in good agreement with the theoretical prediction from a semi-empirical weak-coupling model and its half-life is in the range of tens of nanoseconds. The feeding of a previously known isomer in Tl 202 exhibits similarities with the feeding of other isomers in this mass region.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of the 238 U( n,f ) prompt fission neutron spectrum from 10 keV to 10 MeV induced by neutrons with 1.5–20 MeV energy

With the recent emergence of fast nuclear reactors, there has been a corresponding increasing interest in 238 U-related nuclear data. However, while existing literature data span much of the energy ranges of interest for the prompt fission neutron spectrum (PFNS) for neutron-induced fission of 238U, most literature data sets are highly correlated, and thus new, independent measurements of this quantity are needed. In this work, we report the results of a new measurement of the 238 U PFNS at the Los Alamos Neutron Science Center for incident neutron energies from 1.5–20.0 MeV, and outgoing neutron energies of 0.01–10.0 MeV. With some notable exceptions, the present results generally agree with existing literature data, especially with regard to features relating to multichance fission and pre-equilibrium features in the PFNS, thus adding confidence to existing nuclear data evaluations and filling in gaps of knowledge at previously unmeasured incident neutron energies. This result is the third in a series of PFNS measurements by the Chi-Nu collaboration now spanning all three major actinides, 239 Pu, 235 U, and 238 U. Thus, for the first time, we report reliable experimental PFNS ratios and average PFNS energy comparisons for measurements of all three of these isotopes including accurate correlations between the different, but correlated experiments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Large Area Picosecond Photodetector for Neutron Transmission Measurements at DICER at LANSCE

The Device for Indirect Capture Experiments on Radionuclides (DICER) is a new instrument that is being developed at the Los Alamos Neutron Science Center (LANSCE) to study neutron capture reactions on short-lived radionuclides. To achieve that, DICER is using an indirect technique based on measuring the neutron transmission through very small samples (0.12–1.2 mm in diameter, $\mu \text{g}$ -mg in mass). The main detection system of DICER consists of two dual photomultiplier (PMT)-based detectors which are sensitive to the scintillation light produced when neutrons interact with 6 Li glass disks. DICER is developing a new collimation system that includes a 0.1-mm collimator. In such small sizes, the need for neutron beam imaging is crucial and necessary to confirm the appropriate alignment between the irradiated sample and the neutron detectors. The large area picosecond photodetector (LAPPD) is a multichannel plate (MCP)-based photodetector, with picosecond-level timing, single-photon detection capabilities, and spatial resolution of the order of 1 mm. Coupling the LAPPD with a 6 Li glass scintillator results in a neutron imaging detector. The first irradiation of the LAPPD at DICER indicated that apart from imaging the beam, the LAPPD can be used as the main neutron detection system. Furthermore, these results were proof of principle measurements demonstrating the capabilities of the beamline, and the challenge with small samples will be addressed in the future. The first efforts and developments, including irradiations of the LAPPD and the first beam images, will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗