Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “neutron radiography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

In-situ neutron radiography of pore-water movement in portland cement mortar under subzero temperature exposure: Insights from D 2 O-H 2 O systems

Neutron radiography was employed in this study to monitor real-time pore water movement in portland cement mortar exposed to subzero temperatures, providing novel insights into freeze-thaw (F-T) damage mechanisms. Deuterated water (D 2 O) was used to hydrate the cement in the mortar specimens, and the pore structure was saturated with water (H 2 O), allowing for a contrast that enabled detailed tracking of water movement predominantly in the pore structure. Furthermore, the mortar sample was placed on a chiller plate set to subzero temperatures, thereby providing a one-dimensional temperature gradient vertically in the sample. Neutron radiography revealed that unfrozen water migrated upward as the freezing front advanced, which can create hydraulic pressure within the mortar microstructure and may contribute to the initiation and propagation of microcracks during F-T cycles. Additional characterization of the concrete made with D 2 O showed a marked contrast to the samples made with H 2 O, including delayed hydration, diminished compressive strength, and greater porosity. Therefore, while mortar made with D 2 O allowed for greater neutron contrast to the pores filled with H 2 O, further study is required to produce mortars with similar properties to those made with H 2 O. In addition, further refinement is needed to the radiography experiment to allow for greater control of temperatures and potential quantification of the water concentration.

Air-void system↗

Visualization of in-situ chemical flow through sand using neutron radiography

Chemical movement through soil is an important process in agriculture and ecology. Observing the spatial and temporal dynamics of these processes using conventional chemical ecology methods requires techniques that are destructive and/or lack resolution. Neutron radiography has the capability to allow chemical motion through sand/soil to be tracked with high spatial and temporal resolution, and we show that it allows for the motion of hydrophobic and hydrophilic chemicals to be distinguished. This technique can have an important impact on introducing neutron radiography to a wider community and into our understanding of chemical communication dynamics between plants and movement of applied chemicals in agricultural soils.

MORRIS, KATHRYN [Xavier University]↗

Preliminary hyperspectral neutron radiography of binder jet 3D printed and melt infiltrated Si–SiC

The preliminary results of hyperspectral neutron radiography of Si–SiC made with binder jet additive manufacturing, subsequent carbon addition, and silicon melt infiltration are presented. The samples were measured in the processing states before and after the melt infiltration to determine if neutrons would help characterize the microstructure to better understand the melt infiltration process. Theoretical Bragg edges were calculated for comparison with the radiographic results. The changes in the Bragg edges from pre- to post-infiltrated reaction-bonded SiC were evident, that could be used to address the differences in microstructures. In conclusion, the preliminary results presented in this study demonstrated that neutron Bragg-edge imaging is possible with Si–SiC reaction-bonded ceramics and can help determine the microstructure of melt infiltrated samples.

SiC↗

Gantryless Associated-Particle Neutron Radiography

The present work reports on the development of techniques for in-field fast-neutron radiography measurements using the associated-particle imaging (API) method. The API method employs alpha-neutron coincidences from the d+t→α+n reaction to enable fast neutron transmission imaging with excellent contrast using a wide cone beam. However, for field radiography applications, the API method is burdened by the need for the relative positions of the source and detector to be known. Fortunately, these relative positions can be inferred from transmission data. The inferred positions also enable accurate stitching of multiple images into a composite image even when using a low-resolution detector panel and acquiring images having few overlapping pixels. The developed techniques address analysis of measurements where (1) the source and detector panel are separately hand positioned rather than held in registration by a gantry, (2) multiple detector panel positions within the “coincident cone” of tagged neutrons are required to piece together an image of an item of interest, and (3) normalization measurements that have identical source-detector positioning but without the inspected object are not possible. The present work will describe the system calibrations (including timing calibrations and neutron direction calibrations) necessary for subsequent analyses, the method of locating the detector in the coincident cone of neutrons with millimeter precision using the timing and directions of coincident neutrons, the method of calculating a normalization image for a given detector panel position, and the method used to project multiple images into a common image.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The measurement of capsule heat transfer gaps using neutron radiography.

The use of neutron radiographs to determine dimensional changes of heat transfer gaps in cylindrical nuclear fueled capsules is described. A method was developed which involves scanning a very fine grained neutron radiograph negative with a recording microdensitometer. The output of the densitometer is recorded on graph paper and the heat transfer gap is plotted as a well-defined optical density change. Calibration of the recording microdensitometer ratio arms permits measurements to be made of the heat transfer optical density change from the microdensitometer trace. Total heat transfer gaps, measured by this method, agree with the physical measurements within plus or minus 0.005 cm over a range of gaps from 0.061 to 0.178 cm.

Thaler, L. A.↗

System Response Characterization for a d–t Neutron Radiography System

We report the system response of a pixelated associated particle imaging (API) neutron radiography system. The detector readout currently consists of a 2x2 array of organic glass scintillator detectors, each with an 8x8 array of optically isolated pixels that match the size and pitch of the ARRAYJ-60035-64P-PCB Silicon Photomultiplier (SiPM) array from SensL/onsemi with 6x6 mm 2 SiPMs. The alpha screen of the API deuterium-tritium neutron generator is read out with the S13361-3050AE-08 from Hamamatsu, which is an 8x8 array of 3x3 mm 2 SiPMs. Data from the 320 channel system is acquired with the TOFPET2-based readout system. We present the predicted imaging capability of an eventual 5x5 detector array, the waveform-based energy and pulse shape characterization of the individual detectors, and the timing and energy response from the TOFPET2 system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron Radiography and Computed Tomography of Biological Systems at the Oak Ridge National Laboratory's High Flux Isotope Reactor

Neutrons have historically been used for a broad range of biological applications employing techniques such as small-angle neutron scattering, neutron spin echo, diffraction, and inelastic scattering. Unlike neutron scattering techniques that obtain information in reciprocal space, attenuation-based neutron imaging measures a signal in real space that is resolved on the order of tens of micrometers. The principle of neutron imaging follows the Beer-Lambert law and is based on the measurement of the bulk neutron attenuation through a sample. Greater attenuation is exhibited by some light elements (most notably, hydrogen), which are major components of biological samples. Contrast agents such as deuterium, gadolinium, or lithium compounds can be used to enhance contrast in a similar fashion as it is done in medical imaging, including techniques such as optical imaging, magnetic resonance imaging, X-ray, and positron emission tomography. For biological systems, neutron radiography and computed tomography have increasingly been used to investigate the complexity of the underground plant root network, its interaction with soils, and the dynamics of water flux in situ. Moreover, efforts to understand contrast details in animal samples, such as soft tissues and bones, have been explored. This manuscript focuses on the advances in neutron bioimaging such as sample preparation, instrumentation, data acquisition strategy, and data analysis using the High Flux Isotope Reactor CG-1D neutron imaging beamline. The aforementioned capabilities will be illustrated using a selection of examples in plant physiology (herbaceous plant/root/soil system) and biomedical applications (rat femur and mouse lung).

Bilheux, Hassina↗

Design Investigation of a Scalable Fast Neutron Radiography Panel

Advances in flat-panel radiography device design have increased the use of radiation imaging as a nondestructive evaluation tool. Neutron radiography offers many advantages compared to photon-based radiography.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Internal flow measurements of the SSME fuel preburner injector element using real time neutron radiography

Due to observations of unsteady flow in the Space Shuttle Main Engine fuel preburner injector element, several flow studies have been performed. Real time neutron radiography tests were recently completed. This technique provided real time images of MiL-c-7024 and Freon-22 flow through an aluminum liquid oxygen post model at three back pressures (0, 150, and 545 psig) and pressure drops up to 1000 psid. Separated flow appeared only while operating at back pressures of 0 and 150 psig. The behavior of separated flow was similar to that observed for water in a 3x acrylic model of the LOX post. On the average, separated flow appeared to reattach near the exit of the post when the ratio of pressure drop to supply pressure was about 0.75.

Lindsay, John T.↗

Quantitative near-field water–air spray measurements at elevated pressures by neutron radiography imaging

Extensive experimental research on high-pressure spray has been conducted for decades to deepen our understanding and optimize its use in transportation, aviation, and propulsion applications; however, the near-field and in-nozzle flow characteristics are not fully understood. Dense near-field spray is among the most challenging diagnostic tasks since light is severely scattered and diffused by the liquid droplets and columns. In this work, the near-field spray and in-nozzle flow characteristics of an aeration nozzle at elevated pressures were characterized by neutron radiography imaging at the Oak Ridge National Laboratory High Flux Isotope Reactor. Neutron imaging benefits via strong penetration depths for some metals (i.e., aluminum, lead, and steel) and is sufficiently sensitive to detection of light elements, especially for hydrogen-based molecules, due to the large incoherent scattering cross section of neutrons. Both two-dimensional snapshots of the near-field spray and a three-dimensional tomographic scan of the nozzle geometry and in-nozzle water were obtained. This work provides new quantitative characterization of practical metal nozzle geometry for accurate boundary conditions, internal flow patterns inside the nozzle, and high-pressure spray flows. In conclusion, the findings may be used to improve performance and operating conditions of transportation vehicles and propulsion systems.

42 ENGINEERING↗

Epithermal and Fast Neutron Radiography Facility HFIR Futures – Enhanced Capabilities Series (Vol. 8)

The Sustaining and Enhancing Nuclear Science Initiative at Oak Ridge National Laboratory (ORNL) was created to explore potential enhancements to scientific capabilities in the High Flux Isotope Reactor as part of a reactor pressure vessel replacement project. One proposed scientific enhancement included creation of an epithermal and fast neutron radiography station on the HB-3 beam tube with the capability to image highly radioactive specimens such as irradiated nuclear fuel rods, isotope production targets, or spallation neutron target materials. This document summarizes findings and recommendations from a working group of ORNL staff tasked with conceptualizing such a facility and includes a background of similar instruments at other research facilities, technical specifications, and an estimate of procurement cost and schedule.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Operando neutron radiography validates a parameter-free transport–kinetics model for thick solid-state battery cathodes

Tortuosity-weighted interfacial flux for lithium (TWIF-Li) predicts through-thickness Li gradients in thick composite all-solid-state cathodes without fitted parameters. Image-derived microstructures, GITT-derived concentration-dependent solid diffusion, and tortuosity-weighted interfacial kinetics reproduce operando neutron radiography across practical rates, delivering transferable design rules to suppress transport-limited reaction fronts.

Adam, Andre [ORNL] (ORCID:0000000245023033)↗