Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “narrow linewidth”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Titanium-doped sapphire laser research and design study

Three main topics were considered in this study: the fundamental laser parameters of titanium-doped sapphire, characterization of commercially grown material, and design of a tunable, narrow-linewidth laser. Fundamental parameters investigated included the gain cross section, upper-state lifetime as a function of temperature and the surface-damage threshold. Commercial material was found to vary widely in the level of absorption of the laser wavelength with the highest absorption in Czochralski-grown crystals. Several Yi:sapphire lasers were constructed, including a multimode laser with greater than 50mJ of output energy and a single-transverse-mode ring laser, whose spectral and temporal characteristics were completely characterized. A design for a narrow-linewidth (single-frequency) Ti:sapphire laser was developed, based on the results of the experimental work. The design involves the use of a single-frequency, quasi-cw master oscillator, employed as an injection source for a pulsed ring laser.

Moulton, Peter F.↗

The Challenges of Measuring Methane from Space with a Lidar

The global and regional quantification of methane fluxes and identification of its sources and sinks has been highlighted as one of the goals of the NASA 2017 Earth Science Decadal Survey. Detecting methane from space and airborne platforms with an active (laser) remote sensing instrument presents several unique technology and measurement challenges. The instrument must have a single frequency, narrow-linewidth light source, and photon-sensitive detector at the right spectral region to make continuous measurements from orbit, day and night, all seasons and at all latitudes. It must have a high signal to noise ratio and must be relatively immune to biases from aerosol/cloud scattering, spectroscopic and meteorological data uncertainties, and instrument systematic errors. At Goddard Space Flight Center (GSFC), in collaboration with industry, we have developed an airborne instrument to measure methane. Our instrument is a nadir-viewing lidar that uses Integrated Path Differential Absorption (IPDA), to measure methane near 1.65 µm. We sample the absorption line using multiple wavelengths from a narrow linewidth laser source and a sensitive photodetector. This measurement approach provides maximum information content about the CH4 column, and minimizes biases in the XCH4 retrieval. In this paper, we will review our progress to date and discuss the technology challenges, options and tradeoffs to measure methane from space and airborne platforms.

airborne instruments↗

Semiconductor Laser Linewidth Measurements for Space Interferometry Applications

Narrow linewidth (<100KHz) semiconductor lasers are expected to be a key technology in NASA's stellar interferometry missions to search for planets around nearby stars. Long coherence length lasers are needed for precise (20 pm to 5 mn) measurements of the optical path difference. This work discusses results using the self-heterodyne delay technique to measure 1.3 micrometer InP based DFB lasers. We will also address practical issues concerning detection and elimination of back reflections, choice of fiber length and resolution, and measurement of laser 1/f and current supply noise.

Dougherty, D. J.↗

Stable isotope laser spectroscopy

Recent advances in semiconductor laser technology have produced a reliable lightweight device ideally suited for a spacecraft high resolution molecular spectrometer. Lead-salt tunable diode lasers (TDL) emit in several spectral modes, each with a very narrow linewidth of -0.0003/cm. This spectral resolution is much narrower than typical Doppler broadened molecular linewidths in the mid-IR range. Thus it is possible to detect individual rotational lines within the vibrational band and measure their intensity, which can be used to determine gas concentration. The narrow spectral lines of any impurity gas tend to lie between the narrow lines of the gas of interest. This represents a major advantage over the accepted gas chromatograph mass spectrometer (GCMS) technique for measuring gas concentrations and isotope ratios. The careful and extensive gas purification procedures required to remove impurities for reliable GCMS measurements will not be required for an IR laser gas analysis. The infrared laser gas analysis technique is being developed to measure stable isotopic ratios of gases such as CO2, CH4, N2O, and NH3. This will eventually lead to development of instruments capable of in situ istopic measurements on planets such as Mars. The carbon (C-12, C-13) isotope ratio is indicative of the type of carbon fixation mechanisms (e.g., photosynthesis, respiration) in operation on a planet, while the nitrogen (N-14, N-15) isotope ratio can probably be used to date nitrogen-bearing Martian samples. The absorbance ratio of two adjacent lines of CO2 in the 2300/cm (4.3 micron) region of the spectrum was measured. The precision of the measurement is presently better than 1 percent and significant improvement is anticipated as rapid sweep-integration techniques and computer controlled data acquistion capabilities are incorporated.

Becker, J. F.↗

A quasioptical resonant-tunneling-diode oscillator operating above 200 GHz

We have fabricated and characterized a quasioptically stabilized resonant-tunneling-diode (RTD) oscillator having attractive performance characteristics for application as a radiometric local oscillator. The fundamental frequency of the oscillator is tunable from about 200 to 215 GHz, the instantaneous linewidth is between 10 and 20 kHz, and the output power across the tuning band is about 50 micro-W. The narrow linewidth and fine tuning of the frequency are made possible by a scanning semiconfocal open cavity which acts as the high-Q resonator for the oscillator. The cavity is compact, portable, and insensitive to vibration and temperature variation. The total dc power consumption (RTD plus bias supply) is only 10 mW. The present oscillator provides the highest power obtained to date from an RTD above 200 GHz. We attribute this partly to the use of the quasioptical resonator, but primarily to the quality of the RTD. It is fabricated from the In(0.53)Ga(0.47)As/AlAs materials system, which historically has yielded the best overall resonant-tunneling characteristics of any material system. The RTD active area is 4 sq microns, and the room-temperature peak current density and peak-to-valley current ratio are 2.5x10(exp 5) A cm(exp -2) and 9, respectively. The RTD is mounted in a WR-3 standard-height rectangular waveguide and is contacted across the waveguide by a fine wire that protrudes through a via hole in a Si3N4 'honeycomb' overlayer. We estimate that the theoretical maximum frequency of oscillation of this RTD is approximately 1.1 THz, and that scaled-down versions of the same quasioptical oscillator design should operate in a fundamental mode up to frequencies of at least 500 GHz.

Brown, E. R.↗

Measuring Rocket Engine Temperatures with Hydrogen Raman Spectroscopy

Optically accessible, high pressure, hot fire test articles are available at NASA Marshall for use in development of advanced rocket engine propellant injectors. Single laser-pulse ultraviolet (UV) Raman spectroscopy has been used in the past in these devices for analysis of high pressure H2- and CH4-fueled combustion, but relies on an independent pressure measurement in order to provide temperature information. A variation of UV Raman (High Resolution Hydrogen Raman Spectroscopy) is under development and will allow temperature measurement without the need for an independent pressure measurement, useful for flows where local pressure may not be accurately known. The technique involves the use of a spectrometer with good spectral resolution, requiring a small entrance slit for the spectrometer. The H2 Raman spectrum, when created by a narrow linewidth laser source and obtained from a good spectral resolution spectrograph, has a spectral shape related to temperature. By best-fit matching an experimental spectrum to theoretical spectra at various temperatures, a temperature measurement is obtained. The spectral model accounts for collisional narrowing, collisional broadening, Doppler broadening, and collisional line shifting of each Raman line making up the H2 Stokes vibrational Q-branch spectrum. At pressures from atmospheric up to those associated with advanced preburner components (5500 psia), collisional broadening though present does not cause significant overlap of the Raman lines, allowing high resolution H2 Raman to be used for temperature measurements in plumes and in high pressure test articles. Experimental demonstrations of the technique are performed for rich H2-air flames at atmospheric pressure and for high pressure, 300 K H2-He mixtures. Spectrometer imaging quality is identified as being critical for successful implementation of technique.

Wehrmeyer, Joseph A.↗

NASA Space Laser Technology

Over the next two decades, the number of space based laser missions for mapping, spectroscopy, remote sensing and other scientific investigations will increase several fold. The demand for high wall-plug efficiency, low noise, narrow linewidth laser systems to meet different systems requirements that can reliably operate over the life of a mission will be high. The general trends will be for spatial quality very close to the diffraction limit, improved spectral performance, increased wall-plug efficiency and multi-beam processing. Improved spectral performance will include narrower spectral width (very near the transform limit), increased wavelength stability and or tuning (depending on application) and lasers reaching a wider range of wavelengths stretching into the mid-infrared and the near ultraviolet. We are actively developing high efficiency laser transmitter and high-sensitivity laser receiver systems that are suitable for spaceborne applications.

Electro-Optics↗

Free-flying experiment to measure the Schawlow-Townes linewidth limit of a 300 THz laser oscillator

Recent advances in laser diode-pumped solid state laser sources permit the design and testing of laser sources with linewidths that approach the Schawlow-Townes limit of 1 Hz/mW of output power. Laser diode pumped solid state ring oscillators have been operated with CW output power levels of 25 mW at electrical efficiencies that exceed 6 percent. These oscillators are expected to operate for lifetimes that approach those of the laser diode sources which is now approaching 20,000 hours. The efficiency and lifetime of these narrow linewidth laser sources will enable space measurements of gravity waves, remote sensing applications (including local range rate and measurements), and laser sources for frequency and time standards. A free-flight experiment, 'SUNLITE', is being designed to measure the linewidth of this all-solid-state laser system.

Byer, R. L.↗

Linewidth characteristics of Raman-shifted dye laser output at 720 and 940 nm

Existing DIAL systems for water vapor measurements in the troposphere operate at wavelengths near 720 nm. The use of stronger water vapor absorption lines in the range 930 to 960 nm will significantly improve DIAL measurements in the upper troposphere and lower stratosphere where water vapor concentrations are low. The generation of light at 940 nm using a frequency doubled Nd:YAG pumped dye laser is inefficient due to the small absorption if infrared dyes at the pump wavelength. However, 940 nm generation utilizing stimulated Raman scattering of dye lasers is attractive because of a potentially high conversion efficiency plus the possibility of retaining the narrow linewidth available from some dye lasers. The Raman conversion efficiency and line broadening are presented for first Stokes operation at 720 and 940 nm using hydrogen and deuterium as the Raman media.

Grossmann, B. E.↗

Advanced Water Vapor Lidar Detection System

In the present water vapor lidar system, the detected signal is sent over long cables to a waveform digitizer in a CAMAC crate. This has the disadvantage of transmitting analog signals for a relatively long distance, which is subjected to pickup noise, leading to a decrease in the signal to noise ratio. Generally, errors in the measurement of water vapor with the DIAL method arise from both random and systematic sources. Systematic errors in DIAL measurements are caused by both atmospheric and instrumentation effects. The selection of the on-line alexandrite laser with a narrow linewidth, suitable intensity and high spectral purity, and its operation at the center of the water vapor lines, ensures minimum influence in the DIAL measurement that are caused by the laser spectral distribution and avoid system overloads. Random errors are caused by noise in the detected signal. Variability of the photon statistics in the lidar return signal, noise resulting from detector dark current, and noise in the background signal are the main sources of random error. This type of error can be minimized by maximizing the signal to noise ratio. The increase in the signal to noise ratio can be achieved by several ways. One way is to increase the laser pulse energy, by increasing its amplitude or the pulse repetition rate. Another way, is to use a detector system with higher quantum efficiency and lower noise, on the other hand, the selection of a narrow band optical filter that rejects most of the day background light and retains high optical efficiency is an important issue. Following acquisition of the lidar data, we minimize random errors in the DIAL measurement by averaging the data, but this will result in the reduction of the vertical and horizontal resolutions. Thus, a trade off is necessary to achieve a balance between the spatial resolution and the measurement precision. Therefore, the main goal of this research effort is to increase the signal to noise ratio by a factor of 10 over the current system, using a newly evaluated, very low noise avalanche photo diode detector and constructing a 10 MHz waveform digitizer which will replace the current CAMAC system.

Elsayed-Ali, Hani↗

Enhanced Lamb dip for absolute laser frequency stabilization

Enhanced Lamb dip width is 5 MHz and total depth is 10 percent of peak power. Present configuration is useful as frequency standard in near infrared. Technique extends to other lasers, for which low pressure narrow linewidth gain tubes can be constructed.

Siegman, A. E.↗

Measurement of the gravitational redshift using a clock in an orbiting satellite

A hydrogen maser clock is proposed for enclosure in an orbiting satellite to measure the gravitational effect on time scales with high accuracy. This experiment is used to test the principle of equivalence for clocks in space. Extremely narrow linewidth of Fe-57 radiation and absorption due to Mossbauer effect over 75 ft vertical distance was used to confirm the prediction of the equivalence principle to 1 part in 100. The fractional frequency shift of a satellite-borne oscillator observed from earth is also given.

Vessot, R. F. C.↗

High-power broadly tunable difference-frequency generation in proustite.

High-power wavelength-tunable coherent radiation has been produced by generating the difference frequency between the output from a tunable narrow-linewidth ruby-pumped infrared dye laser and a Q-switched ruby laser in a proustite crystal. Peak infrared powers in the kilowatt range and wavelength tunability from 3.20 to 5.65 microns have been achieved. The experimentally determined infrared power tuning curves are compared to those predicted by theory for interacting Gaussian light beams.

Decker, C. D.↗

Resonant Doppler velocimeter

Narrow linewidth tunable lasers augur a new kind of laser Doppler velocimetry employing resonant absorption and fluorescence from trace atomic species rather than scattering from particles. This technique may provide better turbulence and small volume information than present velocimetry.

Miles, R. B.↗

Laser-induced two-photon blackbody radiation in the vacuum ultraviolet

Experimental measurements of a new type of vacuum-ultraviolet radiation source are reported. It is shown that the maximum source brightness, within its narrow linewidth, is that of a blackbody at the temperature of a metastable storage level. The laser-induced emission at 569 A from a He glow discharge corresponded to a metastable temperature of 22,700 K and was over 100 times brighter than the 584-A He resonance line.

Zych, L. J.↗

Submillimeter local oscillators for heterodyne spectroscopy

The major technological innovations in continuous wave (CW) submillimeter sources which are specifically suitable for application as local oscillators in heterodyne systems are reviewed. A description of the various sources is given which underscores the general principles and operating features for each type of device. Particular emphasis is placed on CW optically pumped lasers, which have had a dramatic impact as widely available sources of narrow linewidth coherent radiation. The state-of-the-art is summarized for these lasers and performance data are presented for several local oscillator packages. Optically pumped lasers are then compared and contrasted with other competing sources such as backward wave oscillators, IMPATT diodes, and Josephson junctions. By comparing their advantages and limitations for use as local oscillators, the potential applications of these different sources are projected. The prospects for increased tunability, reliability, and scalability are briefly considered, and several novel techniques for generating partially tunable radiation using Schottky diode mixers or CW Raman lasers are highlighted.

Danielewicz, E. J., Jr.↗

Anti-Stokes scattering as an XUV radiation source

Harris (1977) has shown that laser induced scattering from atoms stored in a metastable level may be used to produce an XUV radiation source with several unique properties, including narrow linewidth, tunability, linear polarization, picosecond pulsewidth, and relatively high peak spectral brightness. The present investigation provides a summary concerning the progress made on the use of this radiation source as a unique instrument for XUV spectroscopy, and as a possible flashlamp for a 200 A laser. Zych et al. (1978) demonstrated that the maximum spectral brightness of the source is that of a blackbody with a temperature of the metastable storage level. The peak count rate and peak spectral brightness of the anti-Stokes emission at 569 A are 17 times and 139 times greater than those of the 584 A resonance line. The anti-Stokes process was employed as an external source of radiation for high resolution spectroscopy of the 3p6 shell of potassium. Attention is also given to emission spectroscopy of lithium, metastable levels which are appropriate for storage, and a hollow cathode discharge.

Harris, S. E.↗

Supersonic-nitrogen flow-field measurements with the resonant Doppler velocimeter

The application of the resonant Doppler velocimeter (RDV) for obtaining the mean velocity, temperature, and pressure measurements and flow-field visualization in a supersonic free nitrogen jet is reported. This method utilizes laser-induced fluorescence to determine the spectral absorption of an atomic or molecular species seeded into the flow. A narrow linewidth tunable laser is directed into the flow and the total fluorescence from any point is obtained as the laser is tuned. The velocity of the flow is obtained from the Doppler shifted absorption frequency, and the temperature and pressure of the gas are determined from line broadening measurements. Results are presented for the use of this technique to determine the velocity, temperature, and pressure of the flow of sodium atoms seeded into a supersonic nitrogen jet. It is concluded that the visible signal is sufficiently intense for spatially resolved flow visualization purposes.

Cheng, S.↗