Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “multipoint”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Upgraded multipulse laser and multipoint Thomson scattering diagnostics on EAST

Recently a new Thomson scattering diagnostic system was upgraded in EAST tokamak experiment using a multipulse Nd:YAG (neodymium--yttrium aluminium garnet) laser and a multipoint observation volumes. This diagnostic uses a new optical laser alignment technique that was made to determine accurately the laser position, and a new lens collection system that enables the measurement of wider plasma's object. A composite control system made we can get the results in several seconds. Furthermore, a new data processing method was adopted for much exact results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multipoint vibrometry with dynamic and static holograms

We report on two multipoint vibrometers with user-adjustable position of the measurement spots. Both systems are using holograms for beam deflection. The measurement is based on heterodyne interferometry with a frequency difference of 5 MHz between reference and object beam. One of the systems uses programmable positioning of the spots in the object volume but is limited concerning the light efficiency. The other system is based on static holograms in combination with mechanical adjustment of the measurement spots and does not have such a general efficiency restriction. Design considerations are given and we show measurement results for both systems. In addition, we analyze the sensitivity of the systems which is a major limitation compared to single point scanning systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

In vivo visualization method by absolute blood flow velocity based on speckle and fringe pattern using two-beam multipoint laser Doppler velocimetry

Two-beam multipoint laser Doppler velocimetry (two-beam MLDV) is a non-invasive imaging technique able to provide an image of two-dimensional blood flow and has potential for observing cancer as previously demonstrated in a mouse model. In two-beam MLDV, the blood flow velocity can be estimated from red blood cells passing through a fringe pattern generated in the skin. The fringe pattern is created at the intersection of two beams in conventional LDV and two-beam MLDV. Being able to choose the depth position is an advantage of two-beam MLDV, and the position of a blood vessel can be identified in a three-dimensional space using this technique. Initially, we observed the fringe pattern in the skin, and the undeveloped or developed speckle pattern generated in a deeper position of the skin. The validity of the absolute velocity value detected by two-beam MLDV was verified while changing the number of layers of skin around a transparent flow channel. The absolute velocity value independent of direction was detected using the developed speckle pattern, which is created by the skin construct and two beams in the flow channel. Finally, we showed the relationship between the signal intensity and the fringe pattern, undeveloped speckle, or developed speckle pattern based on the skin depth. The Doppler signals were not detected at deeper positions in the skin, which qualitatively indicates the depth limit for two-beam MLDV.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The multipoint de la Vallee-Poussin problem for a convolution operator

Conditions are discovered which ensure that the space of entire functions can be represented as the sum of an ideal in the space of entire functions and the kernel of a convolution operator. In this way conditions for the multipoint de la Vallee-Poussin problem to have a solution are found. Bibliography: 14 titles.

97 MATHEMATICS AND COMPUTING↗

On the use of a single-fiber multipoint plastic scintillation detector for {sup 192}Ir high-dose-rate brachytherapy

Purpose: The goal of this study was to prove the feasibility of using a single-fiber multipoint plastic scintillation detector (mPSD) as an in vivo verification tool during {sup 192}Ir high-dose-rate brachytherapy treatments.Methods: A three-point detector was built and inserted inside a catheter-positioning template placed in a water phantom. A hyperspectral approach was implemented to discriminate the different optical signals composing the light output at the exit of the single collection optical fiber. The mPSD was tested with different source-to-detector positions, ranging from 1 to 5 cm radially and over 10.5 cm along the longitudinal axis of the detector, and with various integration times. Several strategies for improving the accuracy of the detector were investigated. The device's accuracy in detecting source position was also tested.Results: Good agreement with the expected doses was obtained for all of the scintillating elements, with average relative differences from the expected values of 3.4 {+-} 2.1%, 3.0 {+-} 0.7%, and 4.5 {+-} 1.0% for scintillating elements from the distal to the proximal. A dose threshold of 3 cGy improved the general accuracy of the detector. An integration time of 3 s offered a good trade-off between precision and temporal resolution. Finally, the mPSD measured the radioactive source positioning uncertainty to be no more than 0.32 {+-} 0.06 mm. The accuracy and precision of the detector were improved by a dose-weighted function combining the three measurement points and known details about the geometry of the detector construction.Conclusions: The use of a mPSD for high-dose-rate brachytherapy dosimetry is feasible. This detector shows great promise for development of in vivo applications for real-time verification of treatment delivery.

61 RADIATION PROTECTION AND DOSIMETRY↗

Experimental study of a multipoint cathode corona in an argon flow

Results are presented from experimental studies of a multipoint negative corona in an atmospheric-pressure argon flow. It is shown that a decrease in the interpoint distance, gas circulation through the discharge gap, and the adjustment of ballast resistances in the corona supply circuit allow one to stabilize the discharge and enlarge the operating range of discharge currents.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Autoemission of Multipointed Cathode Matrices Based on p-Type Silicon in Strong Pulsed Electric Fields

In this paper, we experimentally studied the dynamic properties of autoelectron emission in strong pulsed electric fields of microsecond duration for multipointed cathode arrays based on surface-modified silicon crystals of the hole type. A decrease in the thresholds for the autoemission onset with an increase in the pulse duration is shown to increase the transparency of potential barriers due to an increase in the electron energy. Autoemission parameters are determined by surface dipole moments and embedded surface potentials that are formed during plasma etching of silicon in various chemically active media.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Higher order multipoint flux mixed finite element methods on quadrilaterals and hexahedra

We develop higher order multipoint flux mixed finite element (MFMFE) methods for solving elliptic problems on quadrilateral and hexahedral grids that reduce to cell-based pressure systems. The methods are based on a new family of mixed finite elements, which are enhanced Raviart–Thomas spaces with bubbles that are curls of specially chosen polynomials. The velocity degrees of freedom of the new spaces can be associated with the points of tensor-product Gauss–Lobatto quadrature rules, which allows for local velocity elimination and leads to a symmetric and positive definite cell-based system for the pressures. We prove optimal [Formula: see text]th order convergence for the velocity and pressure in their natural norms, as well as [Formula: see text]st order superconvergence for the pressure at the Gauss points. Moreover, local postprocessing gives a pressure that is superconvergent of order [Formula: see text] in the full [Formula: see text]-norm. Numerical results illustrating the validity of our theoretical results are included.

Mathematics↗

Putting multipoint kinetics to the test: preliminary analysis of the MUSE-4 experiment with APOLLO3

Modeling neutron kinetics is a challenging task and over the years, several approaches have been developed offering different tradeoffs between precision and cost. Probably the most popular one is point kinetics (PK), which, despite being very cheap, provides good results for many applications. One of the limitations of PK is that it is not able to model effects that happen before the prompt jump time scale. In practice, applications, where those time scales are interesting, are rare and those for which experimental data are available are even rarer. One of those cases is the MUSE-4 experiment for which the focus is on the very fast behavior and where we have no thermal feedback. As we have shown in a recent paper, a simple extension of PK, known as multipoint kinetics (MPK), can overcome this limitation. In this paper, which is intended as a preliminary study, we show how a simple MPK model can qualitatively reproduce the fast behavior that we cannot model with PK. Moreover, we will show how to exploit its low cost and compact form to model also slow effects as the precursors built up, behaviours that are not affordable to model with more expensive techniques, such as kinetic Monte Carlo simulations. For the periodic pulse transients with no feedbacks we will also provide an analytical solution in closed form. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Local Velocity Postprocessing for Multipoint Flux Methods on General Hexahedra

The authors formulated in a multipoint flux mixed finite element method that reduces to a cell-centered pressure system on general quadrilaterals and hexahedra for elliptic equations arising in subsurface flow problems. In addition they showed that a special quadrature rule yields O(h) convergence for face fluxes on distorted hexahedra. Here a first order local velocity postprocessing procedure using these face fluxes is developed and analyzed. The algorithm involves solving a 3 × 3 system on each element and utilizes an enhanced mixed finite element space introduced by Falk, Gatto, and Monk. Computational results verifying the theory are demonstrated.

97 MATHEMATICS AND COMPUTING↗

Local Velocity Postprocessing for Multipoint Flux Methods on General Hexahedra

The authors formulated a multipoint flux mixed finite element method that reduces to a cell-centered pressure system on general quadrilaterals and hexahedra for elliptic equations arising in subsurface flow problems. In addition they showed that a special quadrature rule yields O(h) convergence for face fluxes on distorted hexahedra. Here a first order local velocity postprocessing procedure using these face fluxes is developed and analyzed. The algorithm involves solving a 3×3 system on each element and utilizes an enhanced mixed finite element space introduced by Falk, Gatto, and Monk. Computational results verifying the theory are demonstrated.

97 MATHEMATICS AND COMPUTING↗