Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “multiple faults”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Fault Slip and Fluid Flow: Seismic Source Analysis to Assess Role of Multiple Slip Patches in Fault Permeability

The relationship between fault reactivation, microearthquakes (MEQs), and permeability evolution during fluid injection plays a critical role in energy harvesting and waste disposal. Recent studies have demonstrated the possibility of predicting fault permeability using cumulative seismic moments of MEQs quantitatively. To understand the underlying physical processes, we conduct fault reactivation experiments using Utah FORGE granitoid and analyze acoustic emission (AE) signals generated during stepwise increases in fluid injection pressure. Frequency analysis of thousands of calibrated AE signals reveals that fault reactivation produces multiple AE source patches with millimeter-scale radii—smaller than the sample fault radius. The cumulative area of the reactivated patches covers the fault multiple times over (∼10x–50x area) for each pressure step. These findings provide mechanistic insight that measured permeability enhancement is not driven by a single large slip event, but by the sequential and interacting activation of multiple slip patches that create a continuous flow pathway.

Nurshal, M. E. M. [Pennsylvania State University, ↗

A multi-agent approach to distribution system fault section estimation in smart grid environment

We report that Multi-Agent Systems (MAS) are seen from different areas as one of the paramount trends for the next generation of power systems. Numerous published studies about MAS discuss its utilization in power distribution networks but none focuses on the prior step to restoration and self-healing that is fault section estimation. This paper aims to show how MAS can improve the utilities’ reliability indexes and consumer satisfaction by overcoming the multiple fault section estimation problem. In order to do this, the authors considered using MAS as a means of communication between smart meters. The purpose of smart meters usage is to employ devices that are already present in smart grids, mainly because of their reading and saving data capacity. The proposed method was tested on a radial feeder generated by the authors. The network was built on HYPERSIM, a software platform of OPAL-RT Technologies. The simulation results show that this MAS provides speed, efficiency, and automation for the process of fault section estimation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Summary Article: IEA HPP Annex 36: Quality Installation / Quality Maintenance Sensitivity Studies

The outcome from this Annex activity clearly identifies that poorly designed, installed, and/or maintained heat pumps operate inefficiently and waste considerable energy compared to their as-designed potential. Additionally, it is clear that small faults for a given field-observed practice are significant, that some attribute deviations (in various equipment applications and geographical locations) have a larger impact than others, and that multiple faults or deviations have a cumulative impact on heat pump performance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A SIMULATION BASED APPROACH TO IMPACT ASSESSMENT OF PHYSICAL FAULTS: LARGE COMMERCIAL BUILDING HVAC CASE STUDY

We develop a simulation-based approach to fault impact analysis for a single duct VAV system, and analyze the dynamic and steady-state impact of equipment physical faults on building operation. The simulation model, a virtual testbed, can capture physical faults in the HVAC system of a large commercial building. The model can be utilized for generating data that can then be analyzed to quantify the impact of single or multiple faults. We illustrate the implementation of three physical faults: supply air temperature sensor bias, outdoor air temperature sensor bias, and cooling coil valve stuck. We simulate each fault with several fault intensity levels and at different seasonal operating conditions. Then, we analyze the impact of the above-mentioned faults using the metrics. The results show that the impact of a given physical fault depends on implemented control logic sequence and the seasonal operating conditions.

Chen, Yan↗

Bearing Fault Detection on Wind Turbine Gearbox Vibrations Using Generalized Likelihood Ratio-Based Indicators: Preprint

Studies in condition monitoring literature often aim to detect rolling element bearing faults because they have one of the biggest shares among defects in turbo machinery. Accordingly, several prognosis and diagnosis methods have been devised to identify fault signatures from vibration signals. The underlying idea behind traditional indicators often revolves around tracking both cyclostationarity and abnormal impulses in the vibration signals without distinguishing the two. A recently proposed method to capture the rolling element bearing degradation lays out the groundwork for new indicator families utilizing generalized likelihood ratio test. This novel approach exploits the cyclostationarity and the impulsiveness of vibration signals independently in order to estimate the most suitable indicators for a given fault. However, the method has yet to be tested on complex experimental vibration signals such as those of a wind turbine gearbox. In this study, the approach is applied to the NREL Wind Turbine Gearbox Condition Monitoring Round Robin Study data set for bearing fault detection purposes. The data set is measured on an experimental test rig of a wind turbine gearbox, hence the complexity of the vibration signals is similar to a real case. Furthermore, the new indicators are also tested with signals that carry multiple fault signatures. The outcome demonstrates that the proposed method is capable of distinguishing between healthy and damaged vibration signals measured on a complex wind turbine gearbox.

condition monitoring↗

Source complexity of the 2015 Mw 7.9 Bonin earthquake

The 30 May 2015 Mw 7.9 Bonin earthquake, one of the largest and deepest earthquakes ever recorded by modern seismology, provides a unique opportunity to study the source process and physical mechanisms of deep-focus earthquakes. We develop a novel back-projection technique that allows source imaging in full three-dimensional space with high depth resolution. Our results indicate an initial SW-NE bilateral source propagation followed by a northwest source extension. The multiple-source inversion reveals a two-step source process with propagating directions near-perpendicular to each other, consistent with the 3D back-projection result. The spatial distribution and focal mechanisms of the sub-events cannot be modeled by a single planar rupture, which may display a curved rupture plane or sub-events crossing multiple fault interfaces. Thus, the complex source process can be best explained by stress or structure heterogeneity within the deep slab.

58 GEOSCIENCES↗

Development of Characterization Technology for Fault Zone Hydrology

Several deep trenches were cut, and a number of geophysical surveys were conducted across the Wildcat Fault in the hills east of Berkeley, California. The Wildcat Fault is believed to be a strike-slip fault and a member of the Hayward Fault System, with over 10 km of displacement. So far, three boreholes of ~;; 150m deep have been core-drilled and borehole geophysical logs were conducted. The rocks are extensively sheared and fractured; gouges were observed at several depths and a thick cataclasitic zone was also observed. While confirming some earlier, published conclusions from shallow observations about Wildcat, some unexpected findings were encountered. Preliminary analysis indicates that Wildcat near the field site consists of multiple faults. The hydraulic test data suggest the dual properties of the hydrologic structure of the fault zone. A fourth borehole is planned to penetrate the main fault believed to lie in-between the holes. The main philosophy behind our approach for the hydrologic characterization of such a complex fractured system is to let the system take its own average and monitor a long term behavior instead of collecting a multitude of data at small length and time scales, or at a discrete fracture scale and to ?up-scale,? which is extremely tenuous.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Limitations of traditional tools for beyond design basis external hazard PRA

Probabilistic risk assessment (PRA) is being used increasingly by the nuclear industry for safety during normal operations as well as for the protection against external hazards. Computation of total risk in an external hazard PRA is dependent on hazard assessment, fragility assessment, and systems analysis. A systems analysis for propagation of component fragilities is conducted using event and fault trees. The event and fault trees for an actual power plant can be fairly large in size, which imposes computational challenges. Hence, certain assumptions are employed for computational efficiency. These assumptions typically represent the conditions imposed during the design basis (DB) scenario. The traditional PRA tools based on these assumptions are also widely applied to perform risk assessment in the context of beyond design basis (BDB) scenarios. However, some of these assumptions may not be valid for certain BDB scenarios. In addition, the probability of dependent failures also increases in BDB scenarios due to common cause failures (CCF) which usually results from design modifications, human errors, etc. In this manuscript, a simple and a relatively more complex illustrative examples are used to show the limitation of these assumptions in the numerical quantification of risk for the case of BDB conditions. Case studies with CCF events across multiple fault trees are also presented to illustrate the effect of these assumptions when traditional approach is used in BDB risk assessment. It is shown that the assumptions are valid for the case of DB conditions but may lead to excessively conservative risk estimates in the case of BDB conditions. Finally, a Bayesian network based top-down algorithm is proposed as an alternative tool for accurate numerical quantification of total risk in systems analysis.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Direct observation of multiple rotational stacking faults coexisting in freestanding bilayer MoS 2

Electronic properties of two-dimensional (2D) MoS 2 semiconductors can be modulated by introducing specific defects. One important type of defect in 2D layered materials is known as rotational stacking fault (RSF), but the coexistence of multiple RSFs with different rotational angles was not directly observed in freestanding 2D MoS 2 before. In this report, we demonstrate the coexistence of three RSFs with three different rotational angles in a freestanding bilayer MoS 2 sheet as directly observed using an aberration-corrected transmission electron microscope (TEM). Our analyses show that these RSFs originate from cracks and dislocations within the bilayer MoS 2 . First-principles calculations indicate that RSFs with different rotational angles change the electronic structures of bilayer MoS 2 and produce two new symmetries in their bandgaps and offset crystal momentums. Therefore, employing RSFs and their coexistence is a promising route in defect engineering of MoS 2 to fabricate suitable devices for electronics, optoelectronics, and energy conversion.

Science & Technology - Other Topics↗

Iterative multi-task learning and inference from seismic images

Seismic interpretation aims to extract quantitative and interpretable attributes from a seismic image produced using some migration method to inform characteristics of a subsurface reservoir or target of interest. Current paradigms for computing seismic attributes mostly rely on single-task algorithms. We develop an iterative, multi-task machine learning method to learn and infer multiple attributes from a seismic image. This method is composed of two stages: a multi-task inference stage and a multi-modal, multi-task refinement stage. The basic mechanism of this method is that we train a multi-task inference neural network (NN) to estimate a set of attributes, including a relative geological time (RGT), a denoised higher-resolution (DHR) seismic image, and multiple fault attributes (including probability, dip, and strike), from a low-resolution, noisy seismic image; then we input the inferred attributes to a multi-task refinement NN to enhance the raw inference results iteratively. The two multi-task NNs are trained separately based on synthetic seismic images and associated attributes generated by a geological modeling algorithm. The software we intend to release is a PyTorch implementation of this multi-task learning method for both 2D and 3D cases along with scripts to run the training/validation. The algorithm and software can be a useful tool for automatic seismic interpretation.

Gao, Kai↗

Description and Analysis of the Hardware Safety Systems for the DOE/SNL SWiFT Wind Turbines

This report covers the design and analysis of the hardware safety systems of the DOE/SNL Scaled Wind Farm Technology facility wind turbines. An analysis of the stopping capability of the turbines in multiple scenarios is presented. Included are calculations of braking torque, simulations of high wind speed emergency stops including multiple fault scenarios, and comparisons of predicted turbine performance to the relevant design standards.

17 WIND ENERGY↗

Simulation Results of a Thermal Power Dispatch System from a Generic Pressurized Water Reactor in Normal and Abnormal Operating Conditions

Amid economic pressures in the U.S. electricity market, nuclear utilities are exploring new revenue streams, including hydrogen production. A generic pressurized water reactor simulator was modified to incorporate a novel design for a TPD system coupled to a hydrogen production plant. Standard malfunctions were included in the simulation design, including steam line breaks at various system locations and flow interruptions in the hydrogen plant due to multiple faults, reflecting anticipated operational challenges. It is imperative that the TPD system operation has a minimal effect on the reactor power, primary coolant system, and turbine system operation and performance. Due to the specific design and application of this TPD system, with the proposed turbine control system changes, the overall impact on the existing plant systems is low. Normal TPD operating scenarios resulted in minor effects on the existing plant systems: reactor power changes by at most 0.2%, and gross generator output changes by 20.5 MWe from 100 MWt of TPD. The most severe malfunction analyzed in this work is a full TPD steam line break downstream of the extraction location, which results in an increase in reactor power of about 0.5%. The gross generator output decreases by 36 MWe, a total decrease of 60 MWe from the full power steady state (FPSS) condition. These results indicate that an industrial hydrogen production plant could be coupled thermally to a nuclear power plant with limited effects on the existing system operation and safety.

08 HYDROGEN↗

Model-Based Investigation of Multi-Fault Interactions and Performance Degradation in Residential Heat Pump Systems

Faults in heat pump systems can significantly degrade performance, reduce efficiency, and accelerate component wear, leading to higher operating costs and maintenance demands. While numerous studies have investigated the impact of individual faults, the interactions between multiple concurrent faults remain insufficiently understood, despite their common occurrence in real-world operation. This study conducts a comprehensive simulation analysis of multiple simultaneous faults in a vapor compression heat pump using a validated heat pump design model (HPDM) tool. Detailed component-level modeling methods are implemented to examine performance sensitivity under combinations of refrigerant flow and heat exchanger faults. The results reveal complex fault interactions that can mask or amplify system deviations, challenging conventional diagnostic approaches. Findings from this work provide meaningful insights for the development of more robust fault detection and diagnosis algorithms, supporting improved reliability and energy efficiency in next-generation heat pump technologies.

Hu, Yifeng [ORNL] (ORCID:0000000242875185)↗

Structural Inventory of Great Basin Geothermal Systems and Definition of Favorable Structural Settings

Structural controls of 426 geothermal systems in the Great Basin region including western Nevada, central Nevada, northwestern Nevada, northeastern Nevada, east-central Nevada, eastern California, southern Oregon, and western Utah were analyzed with literature research, air photos, Google Earth imagery, and/or field reviews. Of the systems analyzed, we were able to determine the structural settings of more than 240 sites. The structural catalogue is stored in a master spreadsheet included in this submission. Data components include structural setting, primary fault orientation, presence or absence of Quaternary faulting, reservoir lithology, geothermometry, presence or absence of recent magmatism, and distinguishing blind systems from those that have surface expressions. Systems were cataloged into the following eight major groups, based on the dominant pattern of faulting: - Major normal fault segments (i.e., near displacement maxima). - Fault bends. - Fault terminations or tips. - Step-overs or relay ramps in normal faults. - Fault intersections. - Accommodation zones (i.e., belts of intermeshing oppositely dipping normal faults), - Displacement transfer zones whereby strike-slip faults terminate in arrays of normal faults. - Transtensional pull-aparts. These settings form a hierarchal pattern with respect to fault complexity. - Major normal faults and fault bends are the simplest. - Fault terminations are typically more complex than mid-segments, as faults commonly break up into multiple strands or horsetail near their ends. - A fault intersection is generally more complex, as it generally contains both multiple fault strands and can include discrete dilational quadrants. - A step-over consists of two overlapping fault terminations and thus involves additional complexity, especially where the relay ramp is breached by multiple fault splays between the main overlapping faults and thus contains multiple fault intersections. - Accommodation zones involve further complexity, as they contain multiple fault terminations and fault intersections.

15 GEOTHERMAL ENERGY↗

Fault isolation and fault-tolerant control for Takagi-Sugeno fuzzy time-varying delay stochastic distribution systems

A fault isolation, estimation, and fault-tolerant control (FTC) scheme for nonlinear time-varying delay stochastic distribution control systems was presented in this paper. The Takagi-Sugeno fuzzy model was adopted to approach the nonlinear dynamics of time-varying delay systems. According to the output equivalence principle and Laplace transformation, an augmented state vector was given to solve the time-varying delay problem. When multiple actuator faults and interference occur simultaneously, fault detection, isolation and fault estimation was designed to obtained the fault information. To decouple faults and obtain the value and location information of the fault, the system was separated into two parts through the designed multiple conversion matrices, in which one subsystem was only affected by one actuator fault. This has simplified the design of fault isolation and estimation. A adaptive observer for fault estimation was given. Then, fault information such as the time, location, and size was determined. The observer gain matrices were calculated using linear matrix inequality (LMI). When a fault was detected and diagnosed, a FTC algorithm was devised using the proportional-integral control scheme to compensate the fault as much as possible. It has been shown that even if multiple faults actuator occurred simultaneously, the FTC controller still ensured the output probability density function of the system traced the desired probability density function when a fault occurred. Finally, the expected results were obtained through the simulation example, which confirmed the effectiveness of the method.

42 ENGINEERING↗

Detailed analysis of geothermal potential in Crescent Valley, north-central Nevada

This study has synthesized geological, geochemical, and geophysical data sets to elucidate the structural architecture and history of the Crescent basin in order to assess its geothermal potential. The Crescent basin is a complex composite basin, consisting primarily of multiple east-tilted half grabens and horst blocks bounded by several major faults of variable strike. Fault kinematic data indicate a present-day west-northwesttrending least principal stress, which in turn suggests that north-northeast-striking normal faults have relatively high slip and dilation tendency. However, a protracted history of changing Cenozoic extension directions has produced a mosaic of fault patterns, which has generated both segmented fault geometries and multiple fault intersections. These structural complexities have ultimately primed the basin for geothermal activity. Detailed analyses and application of the play fairway methodology have respectively denoted and ranked 12 favorable structural settings capable of hosting geothermal fluids in the Crescent basin. Of the 12 favorable structural settings, five were identified as having a higher likelihood of hosting a relatively high-temperature (>130°C) geothermal system, including Hand-Me-Down Creek, Hot Springs Point, and three other unnamed areas. The Hand-Me-Down Creek hybrid structural setting along the Crescent Valley fault is the only documented relatively high temperature geothermal system identified in the basin. It contains an active 87°C hot spring actively depositing sinter and geothermometry greater than 170°C (possibly >180°C). Future exploration efforts at Hand-Me-Down Creek would benefit from focusing on targeting high permeability zones at depth utilizing densely spaced electromagnetic surveys, fluid flow modeling, and selective drilling that targets specific fault intersections within the greater step-over at depth. The Hot Springs Point hybrid structural setting along the Dry Hills fault hosts a geothermal system, but geothermometry, spring temperatures, and well temperatures indicate that fluids do not exceed ~100°C. Three other relatively promising areas include a fault intersection in the central part of the basin and two step-overs (relay ramps) along the Crescent Valley fault, but additional exploration is needed at these sites, such as 2-m temperature surveys in the dry season, measuring deeper subsurface temperatures through temperature-gradient drilling, and collecting water samples through geoprobe drilling to estimate geothermometry.

15 GEOTHERMAL ENERGY↗

Aftershock sequence of the 2011 Virginia earthquake derived from the dense AIDA array and backprojection

After the 23 August 2011 Mineral, Virginia, earthquake, a temporary dense array (Aftershock Imaging with Dense Arrays (AIDA)) consisting of ~200 stations was deployed at 200-400 m spacing near the epicenter for 12 days. Backprojection of the data was used to automatically detect and locate aftershocks. The co-deployment of a traditional aftershock network of 36 stations at ~2-10 km spacing enables a quantitative comparison. The AIDA backprojection aftershock catalog is complete to magnitude -1.0 and includes events as small as M-1.8. For comparison, the traditional network was complete to M-0.3 for the same time period. The AIDA backprojection catalog observes the same major patterns of seismicity in the epicentral region, but additional details are illuminated. The primary zone of seismicity is not a single fault but is a tabular zone of multiple small faults, this zone has a subtle concave shape along strike and with depth, and a broader zone of new events is observed at shallow depth. In addition, a new separate, shallow cluster was detected and located to the east of the main aftershock zone. The addition of smaller events to the catalog did not change the b-value or the temporal decay constant, but illuminated spatial and temporal patterns. Both the b-value and temporal decay constant are different for 12 days than for 4 months and are different at < 3km depth than at greater depth. Very low b-value, especially at greater depth, is consistent with observed very high stress drops. Conclusively, the results indicate the benefits of dense arrays and auto-detection by backprojection for aftershock studies. And finally, the reduced detection threshold and higher spatial resolution enabled the study of earthquake mechanisms and strain transfer at an unprecedented small scale.

Beskardes, Gungor Didem↗