At least 37 records · Page 2

Machine learning models of intermittent operation of RO wellhead water treatment for salinity reduction and nitrate removal

Machine learning models were developed for intermittent multi-mode operation of a wellhead reverse osmosis water purification and desalination system to predict salt passage, nitrate passage, and permeate flux. The models, based on long short-term memory (LSTM) recurrent neural network (RNN) architecture, included an attention mechanism to increase model performance in proximity of the regulatory limit for nitrate. Training and testing of the models for the Startup, Production, Shutdown and Flushing operational modes were based on operational data (consisting of 22 process variables per data sample) acquired every 2–5 s over a six-month period. The significant sets of model input attributes for the different operational modes were assessed via Spearman ranking correlation, Self-Organizing Map (SOM) analysis and feed forward feature selection (FFFS). Although the variability of nitrate passage, salt passage and permeate flux was significant over the four operational modes, prediction performance for the three outcomes were with R2 and Average Absolute Relative Error (AARE) of 0.78–0.95 and 2.96–6.16 %, respectively. Model updates post membrane elements replacement demonstrated similar levels of prediction accuracy. The study results suggest that there is merit in exploring the utility of multi-mode models for sensor fault detection, data imputation, and for potential use in model-predictive control.

Intermittent RO operation↗

Data-driven profile prediction for DIII-D

A new, fully data-driven algorithm has been developed that uses neural networks to predict plasma pro les on a scale of τ E into the future given actuators and the present plasma state. The model was trained and tested on DIII-D data from the 2013-2018 experimental campaigns. The model is accurate on average, with q predictions the worst and pressure predictions the best. The model can run in milliseconds and is very simple to use. This makes it a potentially useful tool for operators and physicists when planning plasma scenarios. It also is a candidate for doing phase-space exploration without going through the DIIID database or complicated and computationally expensive simulation codes. Here, a reduced model using only realtime diagnostics has also been developed and formed the basis for a model-predictive control algorithm implemented and successfully tested on DIII-D.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Time-dependent SOLPS-ITER simulations of the tokamak plasma boundary for model predictive control using SINDy *

Abstract Time-dependent SOLPS-ITER simulations have been used to identify reduced models with the sparse identification of nonlinear dynamics (SINDy) method and develop model-predictive control of the boundary plasma state using main ion gas puff actuation. A series of gas actuation sequences are input into SOLPS-ITER to produce a dynamic response in upstream and divertor plasma quantities. The SINDy method is applied to identify reduced linear and nonlinear models for the electron density at the outboard midplane n e , s e p O M P and the electron temperature at the outer divertor T e , s e p d i v . Note that T e , s e p d i v is not necessarily the peak value of T e along the divertor. The identified reduced models are interpretable by construction (i.e. not black box), and have the form of coupled ordinary differential equations. Despite significant noise in T e , s e p d i v , the reduced models can be used to predict the response over a range of actuation levels to a maximum deviation of 0.5% in n e , s e p O M P and 5%–10% in T e , s e p d i v for the cases considered. Model retraining using time history data triggered by a preset error threshold is also demonstrated. A model predictive control strategy for nonlinear models is developed and used to perform feedback control of a SOLPS-ITER simulation to produce a setpoint trajectory in n e , s e p O M P using the integrated plasma simulator framework. The developed techniques are general and can be applied to time-dependent data from other boundary simulations or experimental data. Ongoing work is extending the approach to model identification and control for divertor detachment, which will present transient nonlinear behavior from impurity seeding, including realistic latency and synthetic diagnostic signals derived from the full SOLPS-ITER output.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Transient Efficiency, Flexibility, and Reliability Optimization of Coal-Fired Power Plants - Final Report

This program developed an advanced model-based monitoring and model-predictive control algorithms for a coal fired power plant (CFPP), and deployed these algorithms in a real-time platform to demonstrate performance benefits for transient flexibility and plant operation efficiency. More specifically, the objectives were successfully achieved through a combination of (i) developing a high-fidelity transient plant model in Apros, which was used as a high-fidelity plant simulation between $100-50\% TMCR$ where TMCR denotes the turbine maximum continuous rating, i.e., baseload, (ii) developing a very fast physics-based reduced-order model (ROM) of the plant, which ran more than $100\times$ faster than real-time, enabling its use as real-time embedded model for model-based estimation (MBE) and model predictive control (MPC) (iii) implementing a real-time MBE based on ROM using a robust unscented Kalman filter (UKF) to continuously tune the ROM to match the measurements from high-fidelity Apros plant model despite significant plant-model mismatch, and thus, obtain a Digital Twin of the plant (iv) designing and implementing a real-time MPC with dual objectives of transient plant load tracking with high ramp rates and minimizing coal consumption, i.e., improving plant efficiency in the baseload-partload operation range of $100-50\% TMCR$. Each key element above was developed and tested individually, and has been reported in corresponding Topical Reports. Finally, all the individual elements were integrated in an overall closed-loop system, that was successfully tested in desktop Simulink test harness simulations with ROM or high-fidelity model as the plant. Thereafter, the Simulink implementation was used to auto-generate C-code and deploy as real-time Docker microservice containers in Linux, and validate that they can run in real-time in the hardware-in-the loop (HIL) setup and produce the same results as in Simulink. The results of the integrated simulation tests in Simulink as well as the real-time HIL deployment are documented in this final report, showing good load tracking for load ramps at $3-4\%/min$ ramp rates, and achieving up to $5.5\%$ reduction in coal relative to baseline operation at $50\% TMCR$ load. The desktop and HIL simulations show successful performance of the overall model based estimation and control solution and achieve the key objectives of the program for flexible, efficient and reliable operation of subcritical coal fired power plants.

20 FOSSIL-FUELED POWER PLANTS↗

Melter Modeling over a Range of Scales to Support Vitrification at the WTP

Computational modeling is a powerful complement to laboratory experiments and testing of systems at various scales. When properly applied and validated, computational fluid dynamics (CFD) can provide information not readily obtainable by physical testing, especially in cases where the operating environment does not permit visual observation or the insertion of typical data acquisition instrumentation as in the case of waste glass vitrification. A series of CFD and heat transfer models over a range of scales are being developed to support melter operations at the Hanford Waste Treatment and Immobilization Plant. This paper provides a description of the models and the resulting information they provide that can be used to improve melter throughput, as well as aid in evaluating and resolving operating plant issues or upsets. This work is important for the WTP operation by providing a potential for model-predictive control of the melter operation. Increases in the rate of glass production and avoiding idling can significantly decrease the duration and cost of the vitrification campaign, potentially saving billions of dollars.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Transient Efficiency, Flexibility, and Reliability Optimization of Coal-Fired Power Plants - Final Program Review

This program developed an advanced model-based monitoring and model-predictive control algorithms for a coal fired power plant (CFPP), and deployed these algorithms in a real-time platform to demonstrate performance benefits for transient flexibility and plant operation efficiency. More specifically, the objectives were successfully achieved through a combination of (i) developing a high-fidelity transient plant model in Apros, which was used as a high-fidelity plant simulation between $100-50\% TMCR$ where TMCR denotes the turbine maximum continuous rating, i.e., baseload, (ii) developing a very fast physics-based reduced-order model (ROM) of the plant, which ran more than $100\times$ faster than real-time, enabling its use as real-time embedded model for model-based estimation (MBE) and model predictive control (MPC) (iii) implementing a real-time MBE based on ROM using a robust unscented Kalman filter (UKF) to continuously tune the ROM to match the measurements from high-fidelity Apros plant model despite significant plant-model mismatch, and thus, obtain a Digital Twin of the plant (iv) designing and implementing a real-time MPC with dual objectives of transient plant load tracking with high ramp rates and minimizing coal consumption, i.e., improving plant efficiency in the baseload-partload operation range of $100-50\% TMCR$. Each key element above was developed and tested individually, and has been reported in corresponding Topical Reports. Finally, all the individual elements were integrated in an overall closed-loop system, that was successfully tested in desktop Simulink test harness simulations with ROM or high-fidelity model as the plant. Thereafter, the Simulink implementation was used to auto-generate C-code and deploy as real-time Docker microservice containers in Linux, and validate that they can run in real-time in the hardware-in-the loop (HIL) setup and produce the same results as in Simulink. The results of the integrated simulation tests in Simulink as well as the real-time HIL deployment are documented in this final report, showing good load tracking for load ramps at $3-4\%/min$ ramp rates, and achieving up to $5.5\%$ reduction in coal relative to baseline operation at $50\% TMCR$ load. The desktop and HIL simulations show successful performance of the overall model based estimation and control solution and achieve the key objectives of the program for flexible, efficient and reliable operation of sub-critical coal fired power plants.

20 FOSSIL-FUELED POWER PLANTS↗

Melter Modeling over a Range of Scales to Support Vitrification at the WTP - 19664

Computational modeling is a powerful complement to laboratory experiments and testing of systems at various scales. When properly applied and validated, computational fluid dynamics (CFD) can provide information not readily obtainable by physical testing, especially in cases where the operating environment does not permit visual observation or the insertion of typical data acquisition instrumentation as in the case of waste glass vitrification. A series of CFD and heat transfer models over a range of scales are being developed to support melter operations at the Hanford Waste Treatment and Immobilization Plant. This paper provides a description of the models and the resulting information they provide that can be used to improve melter throughput, as well as aid in evaluating and resolving operating plant issues or upsets. This work is important for the WTP operation by providing a potential for model-predictive control of the melter operation. Increases in the rate of glass production and avoiding idling can significantly decrease the duration and cost of the vitrification campaign, potentially saving billions of dollars. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

IoT-Based Comfort Control and Fault Diagnostics System for Energy-Efficient Homes

This project studies an Internet of Things (IoT)-based comfort control and fault diagnostics system (referred as iComfort in this report) for energy-efficient homes. The system delivers an occupant-comfort-oriented thermal environment adaptive to fault scenarios and achieves HVAC energy savings in a cost-effective and straightforward way. This smart iComfort home system consists of the following key features. 1) Cost-effectiveness and scalability of the entire hardware and software system: The system includes low-cost temperature, humidity, and airflow sensors, and a Raspberry Pi-based local hub that interfaces with the cloud and IoT-enabled devices. The cost is low, not only for sensors, but also the costs associated with sensor installation, system setup and commissioning, data communication and storage, and data analytics (e.g., the development of automated fault detection and diagnosis (AFDD), as well as adaptive control strategies that are both computationally efficient and practical to implement). 2) Energy performance and user satisfaction: The system delivers user satisfaction and energy savings. This includes a) ease of use, b) optimal occupant thermal comfort, and c) accurate system feedback (e.g., low false alarm of AFDD strategies). 3) Favorable demonstrated prototype performance: The prototype tested at the Pacific Northwest National Laboratory (PNNL) Lab Homes demonstrates the accuracy of fault detections and diagnoses and shows thermal comfort improvement and energy savings through adaptive and optimal HVAC operations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Automated model-predictive design of synthetic promoters to control transcriptional profiles in bacteria

Abstract Transcription rates are regulated by the interactions between RNA polymerase, sigma factor, and promoter DNA sequences in bacteria. However, it remains unclear how non-canonical sequence motifs collectively control transcription rates. Here, we combine massively parallel assays, biophysics, and machine learning to develop a 346-parameter model that predicts site-specific transcription initiation rates for any σ 70 promoter sequence, validated across 22132 bacterial promoters with diverse sequences. We apply the model to predict genetic context effects, design σ 70 promoters with desired transcription rates, and identify undesired promoters inside engineered genetic systems. The model provides a biophysical basis for understanding gene regulation in natural genetic systems and precise transcriptional control for engineering synthetic genetic systems.

42 ENGINEERING↗

Modular Isolated Soft-Switching Medium Voltage String Inverter for Large-Scale PV Farm

This paper presents a single-stage modular isolated soft-switching medium voltage string inverter (MVSI) with tri-port configuration to interconnect PV and storage to medium voltage (MV) grid. The modular MVSI provides advanced functionalities such as energy storage elements integration without additional converters, connection to MV grid resulting in lower distribution losses in the PV farm, high-frequency galvanic isolation, independent control of PV, storage and grid power, high modularity and scalability. The topology of the MVSI, operation principle and model-predictive priority-switching (MPPS) control to achieve fast dynamic balancing across stacked modules are discussed. The independent power control is validated in PLECS simulation and the operation of stacked MVSI with MPPS control is verified through Hardware-in-the-loop (HIL) simulation. Here, the hardware prototype of 25 kVA MVSI building block is developed. 18 kW experimental results of single building block verifying tri-ports operation and 20 kW experimental results of two modules stacked operation are presented. A clean sinusoidal waveform with negligibly low THD in both tests is obtained. A low dv/dt of <; 1kV/us and soft-switching are achieved.

30 DIRECT ENERGY CONVERSION↗

Building Operation Model (Morpheus) for Dallas Fort Worth Airport (CRADA CRD-19-16301 Final Report)

The primary objective of this project was to leverage digital twin technology to enhance the design and operation of DFW Airport terminals and their associated energy systems. To achieve this, Morpheus, a building digital twin, was developed to guide improvements in airport operations, specifically targeting reductions in peak power demand and overall energy consumption.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Field evaluation of performance of HVAC optimization system in commercial buildings

Smart new building technologies that offer continuous dynamic optimization of Heating, Ventilation, and Air Conditioning (HVAC) control hold promise to advance building operations for efficiency and grid response. These technologies use data from the control system to determine the analytically optimal setpoints, and then write back the optimal setpoints into the control system to minimize system energy consumption or costs. There are limited studies documenting field validations of these technologies. This paper presents the results from a long-term field evaluation of a model-predictive HVAC optimization system that installed in four commercial buildings. Energy savings analysis was conducted based on pre/post submetered energy use. Across the cohort of evaluation sites, HVAC savings following the implementation of the optimization system were mixed, ranging from 0–9%. Analysis of site operational data showed that occupant comfort was neither positively nor negatively impacted. Key technology adoption considerations and recommendations are summarized in the paper. The technology performs best when HVAC systems are in good working condition, and can be exercised to achieve the full range of its optimized setpoints–however it may not provide extensive additional savings over cases where best practice sequences of operation and reset strategies are already comprehensively implemented.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance Assessment of a Dual-purpose HP-TES for a Typical Year Comparing Different Climate Zones

Complete electrification of heating and cooling systems in the United States would overload the existing electrical grid. To this end, recent research efforts have focused on energy storage as one way to reduce ever-increasing peak electricity demands. One such technology is heat pump integrated thermal-energy storage (HP-TES) systems, which can enable load-shifting and reduce demand during peak hours. In this work, a Modelica model of a 4-Ton, dual-mode (heating and cooling) HP-TES system using a room-temperature phase-change material (PCM) integrated through a secondary hydronic loop was developed and simulated for a typical meteorological year in Riverside, CA (ASHRAE Climate Zone 2B), and Chicago, IL (ASHRAE Climate Zone 5A), for a DOE small office prototype building. The COP improvement and demand reduction were analyzed during the time-of-use peak hours along with the required recharge cycle energy demand. A typical summer in Riverside, CA resulted in model-predicted peak COP increases of 50 – 100% compared to the baseline heat pump, especially at higher outdoor temperatures, coupled with maximum peak energy reductions of 22%. During shoulder and winter season simulations, heating energy savings were higher as outdoor temperatures dropped below the PCM phase change temperature. For Chicago, IL, backup heating was necessary to meet the required system capacity for very cold ambient conditions, resulting in winter peak energy savings between 16 – 60% when accounting for backup heating requirements. The recharge energy was found to be mostly below the baseline HP energy during the peak. With improved component selections and controls, the recharge energy may be reduced. The outcomes from the simulations can provide first-order estimates for potential peak energy savings, challenges, and required controls in any location before conducting any field testing.

25 ENERGY STORAGE↗

Plasma parameters and the reduction potential at a plasma-liquid interface

We report nonthermal plasmas in contact with liquids have been shown to generate a variety of reactive species capable of initiating reduction–oxidation (redox) reactions at the electrochemically active plasma–liquid interface. In conventional electrochemical cells, selective redox chemistry is achieved by controlling the reduction potential at the solid electrode–electrolyte interface by applying a bias via an external circuit. In the case of plasma–liquid systems, an analogous means of tuning the reduction potential near the interface has not clearly been identified. When treated as a floating surface, the liquid is expected to adopt a net negative charge to balance the flux of hot electrons and relatively cold positive ions. The reduction potential near the plasma–liquid interface is hypothesized to be proportional to the floating potential, which can be approximated using an analytical model provided the plasma parameters are known. Herein, we present a framework for correlating the electron density and electron temperature of a noble gas plasma jet to the reduction potential near the plasma–liquid interface. The plasma parameters were acquired for an argon atmospheric plasma jet in contact with an aqueous solution by means of laser Thomson scattering. The reduction potential was determined using identical reference electrodes to measure the potential difference between the plasma–liquid interface and bulk solution. Interestingly, the measured reduction potentials near the plasma–liquid interface were found to be in good agreement with the model-predicted values determined using the plasma parameters obtained from the Thomson scattering experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Processing Aleatory and Epistemic Uncertainties in Experimental Data From Sparse Replicate Tests of Stochastic Systems for Real-Space Model Validation

This paper presents a practical methodology for propagating and processing uncertainties associated with random measurement and estimation errors (that vary from test-to-test) and systematic measurement and estimation errors (uncertain but similar from test-to-test) in inputs and outputs of replicate tests to characterize response variability of stochastically varying test units. Also treated are test condition control variability from test-to-test and sampling uncertainty due to limited numbers of replicate tests. These aleatory variabilities and epistemic uncertainties result in uncertainty on computed statistics of output response quantities. The methodology was developed in the context of processing experimental data for “real-space” (RS) model validation comparisons against model-predicted statistics and uncertainty thereof. The methodology is flexible and sufficient for many types of experimental and data uncertainty, offering the most extensive data uncertainty quantification (UQ) treatment of any model validation method the authors are aware of. It handles both interval and probabilistic uncertainty descriptions and can be performed with relatively little computational cost through use of simple and effective dimension- and order-adaptive polynomial response surfaces in a Monte Carlo (MC) uncertainty propagation approach. A key feature of the progressively upgraded response surfaces is that they enable estimation of propagation error contributed by the surrogate model. Sensitivity analysis of the relative contributions of the various uncertainty sources to the total uncertainty of statistical estimates is also presented. Finally, the methodologies are demonstrated on real experimental validation data involving all the mentioned sources and types of error and uncertainty in five replicate tests of pressure vessels heated and pressurized to failure. Simple spreadsheet procedures are used for all processing operations.

97 MATHEMATICS AND COMPUTING↗

Validation and Recalibration of the Solubility Models in Support of the Heater Test in Salt Formations

The US Department of Energy Office of Nuclear Energy is conducting a brine availability heater test to characterize the thermal, mechanical, hydrological and chemical response of salt at elevated temperatures. In the heater test, brines will be collected and analyzed for chemical compositions. In order to support the geochemical modeling of chemical evolutions of the brines during the heater test, we are recalibrating and validating the solubility models for the mineral constituents in salt formations up to 100°C, based on the solubility data in multiple component systems as well as simple systems from literature. In this work, we systematically compare the model-predicted values based on the various solubility models related to the constituents of salt formations, with the experimental data. As halite is the dominant constituent in salt formations, we first test the halite solubility model in the Na-Mg-Cl dominated brines. We find the existing halite solubility model systematically over-predict the solubility of halite. We recalibrate the halite model, which can reproduce halite solubilities in Na-Mg-Cl dominated brines well. As gypsum/anhydrite in salt formations controls the sulfate concentrations in associated brines, we test the gypsum solubility model in NaCl solutions up to 5.87 mol•kg –1 from 25 ° C to 50 ° C. The testing shows that the current gypsum solubility model reproduces the experimental data well when NaCl concentrations are less than 1 mol•kg –1 . However, at NaCl concentrations higher than 1, the model systematically overpredicts the solubility of gypsum. In the Na + —Cl – —SO 4 2– —CO 3 2– system, the validation tests up to 100 ° C demonstrate that the model excellently reproduces the experimental data for the solution compositions equilibrated with one single phase such as halite (NaCl) or thenardite (Na 2 SO 4 ), with deviations equal to, or less than, 1.5 %. The model is much less ideal in reproducing the compositions in equilibrium with the assemblages of halite + thenardite, and of halite + thermonatrite (Na 2 CO 3 •H 2 O), with deviations up to 31 %. The high deviations from the experimental data for the multiple assemblages in this system at elevated temperatures may be attributed to the facts that the database has the Pitzer interaction parameters for Cl – —CO 3 2– and SO 4 2– —CO 3 2– only at 25 ° C. Finally, in the Na + —Ca 2+ —SO 4 2– —HCO 3 – system, the validation tests also demonstrate that the model reproduces the equilibrium compositions for one single phase such as gypsum better than the assemblages of more than one phase.

36 MATERIALS SCIENCE↗

Induced microearthquakes predict permeability creation in the brittle crust

Predicting the evolution of permeability accurately during stimulation at the reservoir scale and at the resolution of individual fractures is essential to characterize the fluid transport and the reactive/heat-transfer characteristics of reservoirs where stress exerts significant control. Here, we develop a hybrid machine learning (ML) model to visualize in situ permeability evolution for an intermediate-scale (~10 m) hydraulic stimulation experiment. This model includes an ML model that was trained using the well history of flow rate and wellhead pressure and MEQ data from the first three stimulation episodes to predict average permeability from the statistical features of the MEQs alone for later episodes. Moreover, a physics-inspired model is integrated to estimate in situ fracture permeability spatially. This method relates fracture permeability to fracture dilation and scales dilation to the equivalent MEQ magnitude, according to laboratory observations. The seismic data are then applied to define incremental changes in permeability in both space and time. Our results confirm the excellent agreement between the ground truth and model-predicted permeability evolution. The resulting permeability map defines and quantifies flow paths in the reservoir with the averaged permeability comparing favorably with the ground truth of permeability.