Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “model predictive control scheme”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Model predictive control for integrated control of air-conditioning and mechanical ventilation, lighting and shading systems

Modern buildings are increasingly automated and often equipped with multiple building services (e.g., air-conditioning and mechanical ventilation (ACMV), dynamic shading, dimmable lighting). These systems are conventionally controlled individually without considering their interactions, affecting the building’s overall energy inefficiency and occupant comfort. A model predictive control (MPC) system that features a multi-objective MPC scheme to enable coordinated control of multiple building services for overall optimized energy efficiency, indoor thermal and visual comfort, as well as a hybrid model for predicting indoor visual comfort and lighting power is proposed. The MPC system was implemented in a test facility having two identical, side-by-side experimental cells to facilitate comparison with a building management system (BMS) employing conventional reactive feedback control. The MPC system coordinated the control of the ACMV, dynamic façade and automated dimmable lighting systems in one cell while the BMS controlled the building services in the other cell in a conventional manner. The MPC side achieved 15.1–20.7% electricity consumption reduction, as compared to the BMS side. Simultaneously, the MPC system improved indoor thermal comfort by maintaining the room within the comfortable range (-0.5 < predicted mean vote < 0.5) for 98.3% of the time, up from 91.8% of the time on the BMS side. Visual comfort, measured by indoor daylight glare probability (DGP) and horizontal illuminance level at work plane height, was maintained for the entire test period on the MPC side, improving from having visual comfort for 94.5% and 85.7% of the time, respectively, on the BMS side.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Vertical Structure and Ice Production Processes of Shallow Convective Postfrontal Clouds over the Southern Ocean in MARCUS. Part II: Modeling Study

Abstract Part I of this series presented a detailed overview of postfrontal mixed-phase clouds observed during the Measurements of Aerosols, Radiation, and Clouds over the Southern Ocean (MARCUS) field campaign. In Part II, we focus on a multiday (23–26 February 2018) case with the aim of understanding ice production as well as model sensitivity to ice process parameterizations using the Weather Research and Forecasting (WRF) Model. The control simulation with the Predicted Particle Properties (P3) microphysics scheme underestimates the ice content and overestimates the supercooled liquid water content, contrary to the bias common in global climate models. The simulations targeted at ice production processes show negligible sensitivity to cloud droplet number concentrations. Further, neither increasing ice nuclei particle (INP) concentrations to an unrealistic level nor adjusting it to MARCUS field estimations alone guarantees more ice production in the model. However, the simulated clouds are found to be highly sensitive to the implementation of immersion freezing, the thresholding of condensation/deposition freezing initiation, and the rime splintering process. By increasing immersion freezing of cloud droplets, relaxing thresholds for condensation/deposition freezing, or removing rime splintering thresholds, the model significantly improves its performance in producing ice. The relaxation of the immersion freezing temperature threshold to the observed cloud-top temperature suggests an in-cloud seeder–feeder mechanism. The results of this work call for an increase in observations of INP, especially over the remote Southern Ocean and at relatively high temperatures, and measurements of ice particle size distributions to better constrain ice nucleating processes in models.

Meteorology & Atmospheric Sciences↗

An Introduction to the Federated Architecture for Secure and Transactive Distributed Energy Management Solutions (FAST-DERMS)

Deployment and capability of distributed energy resources (DER) in power systems is growing rapidly. These resources present an opportunity for low-cost provision of energy and grid services. The Federal Energy Regulatory Commission recently provided rulings to enable market participation of these distribution-connected resources, but the prevailing strategies for their management may not scale well to meet future needs. This paper introduces the Federated Architecture for Secure and Transactive Distributed Energy Management Solutions (FAST-DERMS) which was designed to address this need. In it we describe the architectural features of the approach, and a reference controls implementation employing a hierarchical coordination that includes stochastic optimization, model predictive control, and a simple real-time management scheme. Sample results from simulation show firm transmission-level service provision measured at the distribution substation.

grid architecture↗

An Introduction to the Federated Architecture for Secure and Transactive Distributed Energy Management Solutions (FAST-DERMS): Preprint

Deployment and capability of distributed energy resources (DER) in power systems is growing rapidly. These resources present an opportunity for low-cost provision of energy and grid services. The Federal Energy Regulatory Commission recently provided rulings to enable market participation of these distribution-connected resources, but the prevailing strategies for their management may not scale well to meet future needs. This paper introduces the Federated Architecture for Secure and Transactive Distributed Energy Management Solutions (FASTDERMS) which was designed to address this need. In it we describe the architectural features of the approach, and a reference controls implementation employing a hierarchical coordination that includes stochastic optimization, model predictive control, and a simple real-time management scheme. Sample results from simulation show firm transmission-level service provision measured at the distribution substation.

DERMS↗

Laboratory Evaluation of Federated, Hierarchical Controls for Distribution Power System Management: Preprint

The connection of more loads and distributed energy resources (DERs) to the distribution power system brings both challenges and opportunities to system operators. There are opportunities to aggregate flexible loads and DERs to provide transmission grid services, but the coordinated actions of DERs being managed by independent, third-party DER aggregators to support transmission system operations can present challenges. We developed a federated DER management architecture and control framework that aims to manage heterogeneous DERs to deliver reliable transmission grid services while respecting distribution system constraints. The controls include stochastic day-ahead optimization, model predictive control, and a simple real-time management scheme. We present simulation results obtained from a realistic laboratory test bed of federated controls managing DERs within a substation service area to make the substation net power follow the optimal net power determined by the day-ahead optimization based on cost and limiting reverse power flow.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Machine learning-enhanced model-based scenario optimization for DIII-D

Abstract Scenario development in tokamaks is an open area of investigation that can be approached in a variety of different ways. Experimental trial and error has been the traditional method, but this required a massive amount of experimental time and resources. As high fidelity predictive models have become available, offline development and testing of proposed scenarios has become an option to reduce the required experimental resources. The use of predictive models also offers the possibility of using a numerical optimization process to find the controllable inputs that most closely achieve the desired plasma state. However, this type of optimization can require as many as hundreds or thousands of predictive simulation cases to converge to a solution; many of the commonly used high fidelity models have high computational burdens, so it is only reasonable to run a handful of predictive simulations. In order to make use of numerical optimization approaches, a compromise needs to be found between model fidelity and computational burden. This compromise can be achieved using neural networks surrogates of high fidelity models that retain nearly the same level of accuracy as the models they are trained to replicate while reducing the computation time by orders of magnitude. In this work, a model-based numerical optimization tool for scenario development is described. The predictive model used by the optimizer includes neural network surrogate models integrated into the fast Control-Oriented Transport simulation framework. This optimization scheme is able to converge to the optimal values of the controllable inputs that produce the target plasma scenario by running thousands of predictive simulations in under an hour without sacrificing too much prediction accuracy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Robust hierarchical dispatch for residential distribution network management considering home thermal flexibility and model predictive control

In the transactive energy (TE) paradigm, the devices of participative consumers, or prosumers, may be aggregated and employed to drive operational objectives at the network level. Home heating, ventilation and air-conditioning (HVAC) systems in particular are well-suited to modulate their behaviours based on both home thermal flexibility and requests from the utility grid. This paper develops a robust, hierarchical power dispatch scheme in the context of a residential distribution network. The formulation couples a unique, multiphase linear distribution optimal power flow (OPF) at the upper level with model predictive control (MPC)-based HVAC fleet controllers at the lower level. The proposed approach is tested on nearly 2000 homes with a three-phase distribution network in an intraday market setting, where two major applications are explored and analysed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Automated calculation and convergence of defect transport tensors

Defect diffusion is a key process in materials science and catalysis, but as migration mechanisms are often too complex to enumerate a priori, calculation of transport tensors typically have no measure of convergence and require significant end-user intervention. These two bottlenecks prevent high-throughput implementations essential to propagate model-form uncertainty from interatomic interactions to predictive simulations. In order to address these issues, we extend a massively parallel accelerated sampling scheme, autonomously controlled by Bayesian estimators of statewide sampling completeness, to build atomistic kinetic Monte Carlo models on a state-space irreducible under exchange and space group symmetries. Focusing on isolated defects, we derive analytic expressions for drift and diffusion coefficients, providing a convergence metric by calculating the Kullback–Leibler divergence across the ensemble of diffusion processes consistent with the sampling uncertainty. The autonomy and efficacy of the method is demonstrated on surface trimers in tungsten and Hexa-interstitials in magnesium oxide, both of which exhibit complex, correlated migration mechanisms.

36 MATERIALS SCIENCE↗

A Generic Two-Vector Model Predictive Control for Hybrid Multilevel Converters

In this article, a generic two-vector model predictive control (TV-MPC) strategy is proposed for the hybrid multilevel converters (HMCs). The proposed method selects two optimal voltage vectors among all the vector candidates using a geometric positioning approach to reduce the computational burden, which is a common issue in the existing MPC methods for HMC. Then duty cycles of the two selected vectors are optimized to minimize the current tracking error, such that the current tracking performance can be enhanced compared with the conventional MPC. In addition, the voltages of the floating dc capacitors can be balanced by evaluating all switching sequences that belong to the optimal voltage vectors with optimal duty cycles. Here, the concept of the proposed TV-MPC is generic and applicable for any HMCs. A typical HMC based on active neutral-point-clamped topology is adopted as a case study in this work. Comprehensive simulation and experimental studies are performed on an all silicon-carbide HMC prototype to validate the effectiveness of the proposed control scheme.

42 ENGINEERING↗

Recurrent neural networks for short-term and long-term prediction of geothermal reservoirs

Accurate prediction of geothermal reservoir responses to alternative energy production scenarios is critical for optimizing the development of the underlying resources. While the conventional physics-based models offer a comprehensive prediction tool, data-driven models provide an efficient alternative to build fit-for-purpose predictive models by extracting and using the statistical patterns in the collected data to make predictions. The recurrent neural network (RNN) is a data-driven model that is commonly applied to predict time series sequences. This paper presents a variant of RNN that also utilizes the efficiency of convolutional neural networks (CNN) for the prediction of energy production from geothermal reservoirs. Specifically, a CNN–RNN architecture is developed that takes historical well controls as input (features) and their corresponding production response data as output (labels) to learn an input-output mapping that can predict the future well production responses/performance for any given future well control inputs. The model is paired with a labeling scheme to handle real field disturbances that create data gaps. In addition to the model structure, we introduce a thorough workflow for applying the model, which includes data pre-processing, feature selection, as well as different training strategies for short-term and long-term prediction. Finally, the performance and accuracy of the model are evaluated by applying it to multiple datasets, including a field reservoir model.

15 GEOTHERMAL ENERGY↗

A Robust Hierarchical Dispatch Scheme for Active Distribution Networks Considering Home Thermal Flexibility

Distribution networks are changing from passive absorbers of electric energy to active distribution networks (ADNs) capable of operating and participating in electricity markets. In the context of residential microgrids, which is a type of ADNs, aggregated home heating, ventilation and air-conditioning (HVAC) loads present a key opportunity to drive operational and economic objectives, facilitate high renewable energy penetration, and enhance both system resiliency and flexibility. A robust, hierarchical dispatch scheme is developed and presented in this paper, which connects an upper level multi-phase distribution optimal power flow (DOPF) to a lower level model predictive control (MPC)-based HVAC fleet controller. The approach is tested and verified on a modified IEEE 13 bus system in an intraday market application. The results demonstrate that the proposed hierarchical dispatch scheme is able to drive both economic and operational objectives for the ADN operator.

Rooks, Cody D.↗

Four-Switch Buck-Boost Converter Based on Model Predictive Control with Smooth Mode Transition Capability

Four-switch buck-boost converter supports both voltage step-up and step-down functionalities, but it suffers from mode transfer challenge that would need reliable mode detection when designed to operate in multi different modes. In this paper, a novel control method based on model predictive current control is proposed for such converter with inherent smooth mode transfer capability without extra design on mode detection and transfer scheme. Modulator and mode detection are replaced by an optimization process through cost function. This largely simplifies the design and makes it easily implemented. Therefore, seamless transfer between buck and boost modes is achieved with many other system level benefits. Simulation and experimental results are provided to verify the effectiveness of proposed method for the four-switch buck-boost converter.

42 ENGINEERING↗

Enzyme activities predicted by metabolite concentrations and solvent capacity in the cell

Experimental measurements or computational model predictions of the post-translational regulation of enzymes needed in a metabolic pathway is a difficult problem. Consequently, regulation is mostly known only for well-studied reactions of central metabolism in various model organisms. In this study, we use two approaches to predict enzyme regulation policies and investigate the hypothesis that regulation is driven by the need to maintain the solvent capacity in the cell. The first predictive method uses a statistical thermodynamics and metabolic control theory framework while the second method is performed using a hybrid optimization–reinforcement learning approach. Efficient regulation schemes were learned from experimental data that either agree with theoretical calculations or result in a higher cell fitness using maximum useful work as a metric. As previously hypothesized, regulation is herein shown to control the concentrations of both immediate and downstream product concentrations at physiological levels. Model predictions provide the following two novel general principles: (1) the regulation itself causes the reactions to be much further from equilibrium instead of the common assumption that highly non-equilibrium reactions are the targets for regulation; and (2) the minimal regulation needed to maintain metabolite levels at physiological concentrations maximizes the free energy dissipation rate instead of preserving a specific energy charge. The resulting energy dissipation rate is an emergent property of regulation which may be represented by a high value of the adenylate energy charge. In addition, the predictions demonstrate that the amount of regulation needed can be minimized if it is applied at the beginning or branch point of a pathway, in agreement with common notions. The approach is demonstrated for three pathways in the central metabolism of E. coli (gluconeogenesis, glycolysis-tricarboxylic acid (TCA) and pentose phosphate-TCA) that each require different regulation schemes. It is shown quantitatively that hexokinase, glucose 6-phosphate dehydrogenase and glyceraldehyde phosphate dehydrogenase, all branch points of pathways, play the largest roles in regulating central metabolism.

59 BASIC BIOLOGICAL SCIENCES↗

Reduced Switching Frequency Finite Control Set Model Predictive Control (FCS-MPC) for DFIG

An enhanced Finite Control Set Model Predictive Control (FCS-MPC) strategy with a two-step prediction horizon for a Doubly-Fed Induction Generator (DFIG) is the focus of this paper. The DFIG and RL filter's discrete-time model is used in the proposed control scheme for a two-step prediction horizon of rotor and filter currents for the converter's eight possible switching states. Afterward, the control algorithm selects the ideal switching state, which minimizes currents' objective function. The proposed control scheme does not require a modulation stage for internal controllers. We use Lagrange extrapolations to predict the dynamic changes in currents. The switching frequency reduction is achieved by integrating an optimization constraint in the algorithm's cost function. Furthermore, the Total Harmonic Distortion level of currents is kept below 5%, according to IEEE Std 519-14. Obtained results reveal that the switching frequency of the DFIG converters is considerably reduced without losing control; it is reduced by 13.89KHz for the Grid Side Converter (GSC) and by 1.78KHz for the Rotor Side Converter (RSC).

doubly-fed induction generator↗

Cybersecurity Anomaly Detection in SCADA-Assisted OT Networks Using Ensemble-Based State Prediction Model

The cybersecurity threats of power system gradually grow due to the increased sophisticated interactions between Information Technology (IT) and Operational Technology (OT) networks. False data injection attack (FDIA) that aims to compromise the Supervisory Control and Data Acquisition (SCADA) measurement and disturb the system operation is one of such cyber threats. Such attacks can potentially lead to significant operational issues at the control centers and substations, and hence, result in severe physical consequences. To avoid catastrophic failure across the power grid resulting from these attacks, it is essential to arm the OT network with real-time vulnerability assessment tools. To this end, this paper outlines various drawbacks of the Purdue architecture model to defend against cyberattacks in the OT network. Furthermore, a novel ensemble-based state prediction model is proposed to detect cybersecurity anomalies in SCADA assisted OT networks. The proposed model uses control center level generation and load forecasts, scheduled, and forced outages, power flow solutions, and the substation level historical data. The hypothesis of the proposed scheme relies on the fact that additional control center and substation data can hardly be accessed and compromised by attackers. One of the vital features of the proposed scheme is an hour-ahead prediction of the operational feasibility of the SCADA measurement range at the control center and substation in real time helps in detecting anomalies in measurements across both substation and the control center.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Model predictive control of heating, ventilation, and air conditioning (HVAC) systems: A state-of-the-art review

Due to the fast advancement of communication and information technology, intelligent buildings have garnered great interest. These buildings can forecast weather, ambient temperature, and sun irradiation and can modify heating, ventilation, and air conditioning (HVAC) operations appropriately, based on current and previous data. This change is intended to reduce HVAC system energy usage while maintaining an appropriate degree of thermal comfort and indoor air quality. Since its inception, model predictive control (MPC) has been one of the prospective solutions for HVAC management systems to reduce both costs and energy usage. Additionally, MPC is becoming increasingly practical as the processing capacity of building automation systems increases and a large quantity of monitored building data becomes available. MPC also provides the potential to improve the energy efficiency of HVAC systems via its capacity to consider limitations, to predict disruptions, and to factor in multiple competing goals such as interior thermal comfort and building energy consumption. Although substantial research has been conducted on MPC in building HVAC systems, there is a shortage of critical reviews and a lack of a comprehensive framework that formulates and defines the applications. Here, this article provides a comprehensive state-of-the-art overview of MPC in HVAC systems. Detailed discussions of modeling approaches and optimization algorithms are included. Numerous design aspects such as prediction horizon, occupancy behavior, building type, and cost function, that impact MPC performance are discussed in detail. The technical characteristics, advantages, and disadvantages of various types of modeling software are discussed. The primary objective of this work is to highlight critical design characteristics for the MPC control scheme and to give improved suggestions for future research. Moreover, numerous prospective scenarios have been suggested that might provide future research direction.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Droplet Evaporation-Based Approach for Microliter Fuel Property Measurements

Small-volume, high-throughput screening techniques are sought to enable downselection from a large candidate pool of bio-blendstocks to a select few, having physical properties consistent with requirements of downsized, turbo-boosted internal combustion engines. Herein, this work presents a droplet evaporation-based approach to predict heat of vaporization, vapor pressure, diffusion coefficient, and Lennard–Jones parameters for an unknown fuel. Two different schemes, considering the isothermal evaporation of a moving droplet in ambient air, are proposed, which combine droplet velocity and temperature measurements, with some known properties to predict unknown properties. The schemes utilize an inverse solution of a transient model of droplet evaporation solved in an iterative fashion. A baseline scheme, which only requires droplet size change measurements, is evaluated using test data for three liquid fuels, comprising of alkanes and alcohols, as obtained in a temperature-controlled chamber. Results yield temperature-dependent heat of vaporization and vapor pressure predictions within 10 % and 22 %, respectively, of reference values. The advanced scheme, which additionally requires droplet temperature measurement, is numerically evaluated in the current work and will be experimentally validated in future efforts. The advanced scheme is found to significantly improve prediction quality, with deviations less than 2 % and 1 % for heat of vaporization and vapor pressure, while also predicting diffusion coefficient and Lennard–Jones parameters within 5 % and 8 %, respectively. The combined set of approaches, which primarily track droplet evaporation, can be incorporated into a small-volume, high-throughput fuel screening process.

09 BIOMASS FUELS↗

Collaborative Distribution System Restoration Planning and Real-Time Dispatch Considering Behind-the-Meter DERs

Modern distribution systems are becoming more resilient against power outages thanks to the flexible generation capacity provided by the increasing integration of distributed energy resources (DERs). Compared to utility-scale DERs, which can be directly controlled by system operators, small-scale, behind-the-meter DERs are much more difficult to coordinate despite being the vast majority. Two major obstacles to the implementation of DERs for service restoration are the coordination of behind-the-meter DERs and the management of uncertainty. In this paper, a novel distribution system restoration strategy is proposed to overcome these two obstacles. The flexibility of be-hind-the-meter DERs is quantified and integrated into the restoration planning models within a hierarchical structure. The model predictive control technique is employed to enable adaptive restoration planning solution adjustments to accommodate fault scenarios and forecast errors. Besides, real-time power dispatch models are proposed to maintain power balance using available DER capability. Comprehensive integration of adaptive restoration planning schemes and real-time dispatch results are achieved through a collaborative restoration framework. Finally, the effectiveness of the proposed restoration strategy is verified through a modified IEEE 123-bus system and a real-world utility system.

24 POWER TRANSMISSION AND DISTRIBUTION↗