Minimum energy structures of faceted, incoherent interfaces
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
A formula for absolute scattering power is derived to include spot fading arising from radiation damage and the crystal volume needed to collect diffraction data to a given resolution is calculated. In this work, classic intensity formulae were united with an empirical spot-fading model in order to calculate the diameter of a spherical crystal that will scatter the required number of photons per spot at a desired resolution over the radiation-damage-limited lifetime. The influences of molecular weight, solvent content, Wilson B factor, X-ray wavelength and attenuation on scattering power and dose were all included. Taking the net photon count in a spot as the only source of noise, a complete data set with a signal-to-noise ratio of 2 at 2 Å resolution was predicted to be attainable from a perfect lysozyme crystal sphere 1.2 µm in diameter and two different models of photoelectron escape reduced this to 0.5 or 0.34 µm. These represent 15-fold to 700-fold less scattering power than the smallest experimentally determined crystal size to date, but the gap was shown to be consistent with the background scattering level of the relevant experiment. These results suggest that reduction of background photons and diffraction spot size on the detector are the principal paths to improving crystallographic data quality beyond current limits.
The minimum value of the safety factor profile is related to the magnetohydrodynamic (MHD) stability of the plasma confined in a tokamak. Therefore, active control of the minimum safety factor may mitigate MHD instabilities that can degrade or even terminate plasma confinement. Typically, in most tokamak scenarios, the minimum safety factor evolves spatially with time, i.e., the location at which the safety factor achieves the minimum value changes with time. In addition to the inherent nonlinearities in the minimum safety factor evolution, its spatial variation makes the control design challenging. In particular, complexity in control design may arise from the need for time-dependent nonlinear models that account for spatial variation of the minimum safety factor. Furthermore, the minimum safety factor may drift to locations where the actuator authority is low. The problem of minimum safety factor control with target location tracking and moving electron cyclotron current drive (ECCD) is addressed in this work. A nonlinear time-dependent model that incorporates the spatial variation of the minimum safety factor is presented. A nonlinear controller based on optimal feedback linearization is developed to track a target minimum safety factor. The proposed controller treats the ECCD position as a controllable variable. In other words, the controller prescribes the ECCD position (in addition to the non-inductive powers) in real time based on an optimal criterion that is defined a priori. This work also presents the steps necessary to integrate the minimum safety factor controller with a total energy controller to achieve multiple control objectives simultaneously. In conclusion, the proposed integrated control algorithm is tested using nonlinear simulations in the Control Oriented Transport SIMulator (COTSIM) for a DIII-D tokamak scenario.
We use the accretion model to explain the early exit of {eta} Car from its 2009 X-ray minimum. In the accretion model, the secondary star accretes mass from the primary wind near periastron passage, a process that suppresses the secondary wind. As the shocked secondary wind is responsible for most of the X-ray emission, the accretion process accounts for the X-ray minimum. The early exit from the 2009 X-ray minimum after four weeks, instead of 10 weeks as in the two previous minima, is attributed to the primary wind that during the last minimum was somewhat faster and of lower mass-loss rate than during the two previous X-ray minima. This results in a much lower mass accretion rate during the X-ray minimum. We show that using fluctuations in these quantities that are within the range deduced from fluctuations in the X-ray flux outside the minimum, can account for the short duration of the last X-ray minimum. The shorter X-ray minimum may have further implications on the recovery of the system from the spectroscopic event.
A systematic effort was undertaken to reevaluate the minimum critical mass for several fissile nuclides and reflectors. This was done using MCNP6 in combination with several modern nuclear data libraries, viz. ENDF/B-VII.1, JENDL-4.0 and JEFF-3.1.1. This combination was benchmarked extensively against criticality safety benchmarks. The procedure to extract the minimum critical mass from the MCNP6 calculations was carefully implemented, so that it would have a negligible impact on the accuracy of the end results. All parts of the calculation, i.e. nuclear data processing, MCNP6 models, and post-processing, were applied consistently for all cases, involving varying fissile nuclides and reflectors. Results for the minimum critical mass were generated for {sup 233,235}U, {sup 236,239,241}Pu, {sup 242m}Am, {sup 243,245,247}Cm, and {sup 249,251}Cf, for the case of water moderation and water reflection. For {sup 235}U, the minimum critical mass was also calculated for cases with other reflectors, such as beryllium, heavy water, graphite, lead, and concrete. The results for the water reflection cases are in good agreement with most of the literature values, but for the cases with reflectors such as graphite, lead, or concrete, there are sizable differences. The accuracy of the results was assessed in two ways. First, a comparison was made with criticality safety benchmark results, by selecting benchmarks that resemble the minimum mass systems the most. It was clear that for {sup 233,235}U and {sup 239}Pu with water reflection, the differences in minimum critical masses between the libraries are consistent with the differences obtained for benchmark cases. The difference between the benchmark calculations and the benchmark values is then an indication of the accuracy with which one can simulate comparable systems. Secondly, sensitivity runs were performed with the new MCNP6 sensitivity option, based on ENDF/B-VII.1 nuclear data. For each fissile nuclide, the sensitivity of k{sub eff} to cross sections such as capture, fission, elastic, inelastic was calculated for the minimum critical mass case. The same was done for the {sup 1}H and {sup 16}O cross sections in the moderator and reflector. The uncertainty in k{sub eff} was calculated by combining the sensitivity profiles with the appropriate ENDF/B-VII.1 covariance matrix, using the SUSD code. As a final step, the uncertainty in k{sub eff} can be translated to an uncertainty in the minimum critical mass. (author)
Purpose: Building up a TG-71 based electron monitor-unit (MU) calculation protocol usually involves massive measurements. This work investigates a minimum data set of measurements and its calculation accuracy and measurement time. Methods: For 6, 9, 12, 16, and 20 MeV of our Varian Clinac-Series linear accelerators, the complete measurements were performed at different depth using 5 square applicators (6, 10, 15, 20 and 25 cm) with different cutouts (2, 3, 4, 6, 10, 15 and 20 cm up to applicator size) for 5 different SSD’s. For each energy, there were 8 PDD scans and 150 point measurements for applicator factors, cutout factors and effective SSDs that were then converted to air-gap factors for SSD 99–110cm. The dependence of each dosimetric quantity on field size and SSD was examined to determine the minimum data set of measurements as a subset of the complete measurements. The “missing” data excluded in the minimum data set were approximated by linear or polynomial fitting functions based on the included data. The total measurement time and the calculated electron MU using the minimum and the complete data sets were compared. Results: The minimum data set includes 4 or 5 PDD’s and 51 to 66 point measurements for each electron energy, and more PDD’s and fewer point measurements are generally needed as energy increases. Using only <50% of complete measurement time, the minimum data set generates acceptable MU calculation results compared to those with the complete data set. The PDD difference is within 1 mm and the calculated MU difference is less than 1.5%. Conclusion: Data set measurement for TG-71 electron MU calculations can be minimized based on the knowledge of how each dosimetric quantity depends on various setup parameters. The suggested minimum data set allows acceptable MU calculation accuracy and shortens measurement time by a few hours.
The origin of the solubility minimum of oxide (M{sub x}O{sub y}) in liquid Fe-M-O alloy was investigated, and the minimum was predicted based on thermodynamic calculations. Due to the characteristic property of activities of M and O in the liquid, a maximum exists in the product between the two activities if the affinity of M to O is significantly high, as most deoxidizing elements are. A critical activity product is defined, which is an indicator of the solubility minimum of the M{sub x}O{sub y} in the liquid Fe-M-O alloy according to the following relationship: max(a{sub M}{sup x}×a{sub O{sub -}{sup y}})=K{sub M{sub xO{sub y}}}×a{sub M{sub xO{sub y}}}, where the a{sub M{sub xO{sub y}}} is unity if the alloy is in equilibrium with the pure M{sub x}O{sub y}. The origin of the solubility minimum was explained using the change of the activity product by composition. Available CALPHAD assessments for several binary Fe-M liquid alloys and Wagner’s solvation shell model were combined to calculate the activity product in the Fe-M-O alloy, which can be used to predict the solubility minimum of M{sub x}O{sub y}. A favorable agreement was obtained when M=Al, B, Cr, Mn, Nb, Si, Ta, Ti, V, and Zr. The Gibbs energy of dissolution of O in pure liquid M (Δg{sub O{sub -(M)}{sup ∘}}) and the Gibbs energy of the formation of M{sub x}O{sub y} per mole of atoms (Δg{sub M{sub xO{sub y}{sup ∘}}}/(x+y)) play important roles in determining the solubility minimum, as long as an interaction between Fe and M is less significant than the interaction between metal (Fe and M) and O. Predictions of the solubility minima of CaO and MgO were not satisfactory, requiring further improvement of the present analysis.
Here, we present two standards developed by the Genomic Standards Consortium (GSC) for reporting bacterial and archaeal genome sequences. Both are extensions of the Minimum Information about Any (x) Sequence (MIxS). The standards are the Minimum Information about a Single Amplified Genome (MISAG) and the Minimum Information about a MetagenomeAssembled Genome (MIMAG), including, but not limited to, assembly quality, and estimates of genome completeness and contamination. These standards can be used in combination with other GSC checklists, including the Minimum Information about a Genome Sequence (MIGS), Minimum Information about a Metagenomic Sequence (MIMS), and Minimum Information about a Marker Gene Sequence (MIMARKS). Community-wide adoption of MISAG and MIMAG will facilitate more robust comparative genomic analyses of bacterial and archaeal diversity.
Here, we present two standards developed by the Genomic Standards Consortium (GSC) for reporting bacterial and archaeal genome sequences. Both are extensions of the Minimum Information about Any (x) Sequence (MIxS). The standards are the Minimum Information about a Single Amplified Genome (MISAG) and the Minimum Information about a Metagenome- Assembled Genome (MIMAG), including, but not limited to, assembly quality, and estimates of genome completeness and contamination. These standards can be used in combination with other GSC checklists, including the Minimum Information about a Genome Sequence (MIGS), Minimum Information about a Metagenomic Sequence (MIMS), and Minimum Information about a Marker Gene Sequence (MIMARKS). Community-wide adoption of MISAG and MIMAG will facilitate more robust comparative genomic analyses of bacterial and archaeal diversity.
Low- and mid-latitude coronal holes (CHs) observed on the Sun during the current solar activity minimum (from 2006 September 21, Carrington rotation (CR) 2048, to 2009 June 26, CR 2084) were analyzed using Solar and Heliospheric Observatory/Extreme ultraviolet Imaging Telescope and STEREO-A SECCHI EUVI data. From both the observations and Potential Field Source Surface modeling, we find that the area occupied by CHs inside a belt of +-40{sup 0} around the solar equator is larger in the current 2007 solar minimum relative to the similar phase of the previous 1996 solar minimum. The enhanced CH area is related to a recurrent appearance of five persistent CHs, which survived during 7-27 solar rotations. Three of the CHs are of positive magnetic polarity and two are negative. The most long-lived CH was being formed during 2 days and existed for 27 rotations. This CH was associated with fast solar wind at 1 AU of approximately 620 +- 40 km s{sup -1}. The three-dimensional magnetohydrodynamic modeling for this time period shows an open field structure above this CH. We conclude that the global magnetic field of the Sun possessed a multi-pole structure during this time period. Calculation of the harmonic power spectrum of the solar magnetic field demonstrates a greater prevalence of multi-pole components over the dipole component in the 2007 solar minimum compared to the 1996 solar minimum. The unusual large separation between the dipole and multi-pole components is due to the very low magnitude of the dipole component, which is three times lower than that in the previous 1996 solar minimum.
Observations of the Sun’s corona during the space era have led to a picture of relatively constant, but cyclically varying solar output and structure. Longer-term, more indirect measurements, such as from {sup 10}Be, coupled by other albeit less reliable contemporaneous reports, however, suggest periods of significant departure from this standard. The Maunder Minimum was one such epoch where: (1) sunspots effectively disappeared for long intervals during a 70 yr period; (2) eclipse observations suggested the distinct lack of a visible K-corona but possible appearance of the F-corona; (3) reports of aurora were notably reduced; and (4) cosmic ray intensities at Earth were inferred to be substantially higher. Using a global thermodynamic MHD model, we have constructed a range of possible coronal configurations for the Maunder Minimum period and compared their predictions with these limited observational constraints. We conclude that the most likely state of the corona during—at least—the later portion of the Maunder Minimum was not merely that of the 2008/2009 solar minimum, as has been suggested recently, but rather a state devoid of any large-scale structure, driven by a photospheric field composed of only ephemeral regions, and likely substantially reduced in strength. Moreover, we suggest that the Sun evolved from a 2008/2009-like configuration at the start of the Maunder Minimum toward an ephemeral-only configuration by the end of it, supporting a prediction that we may be on the cusp of a new grand solar minimum.
The Maunder minimum forms an archetype for the Grand minima, and detailed knowledge of its temporal development has important consequences for the solar dynamo theory dealing with long-term solar activity evolution. Here, we reconsider the current paradigm of the Grand minimum general scenario by using newly recovered sunspot observations by G. Marcgraf and revising some earlier uncertain data for the period 1636-1642, i.e., one solar cycle before the beginning of the Maunder minimum. The new and revised data dramatically change the magnitude of the sunspot cycle just before the Maunder minimum, from 60-70 down to about 20, implying a possibly gradual onset of the minimum with reduced activity started two cycles before it. This revised scenario of the Maunder minimum changes, through the paradigm for Grand solar/stellar activity minima, the observational constraint on the solar/stellar dynamo theories focused on long-term studies and occurrence of Grand minima.
Purpose: CyberKnife{sup ®} robotic surgery system has the ability to deliver radiation to a tumor subject to respiratory movements using Synchrony{sup ®} mode with less than 2 mm tracking accuracy. However, rapid and rough motion tracking causes mechanical tracking errors and puts mechanical stress on the robotic joint, leading to unexpected radiation delivery errors. During clinical treatment, patient respiratory motions are much more complicated, suggesting the need for patient-specific modeling of respiratory motion. The purpose of this study was to propose a novel method that provides a reference respiratory wave to enable smooth tracking for each patient. Methods: The minimum jerk model, which mathematically derives smoothness by means of jerk, or the third derivative of position and the derivative of acceleration with respect to time that is proportional to the time rate of force changed was introduced to model a patient-specific respiratory motion wave to provide smooth motion tracking using CyberKnife{sup ®}. To verify that patient-specific minimum jerk respiratory waves were being tracked smoothly by Synchrony{sup ®} mode, a tracking laser projection from CyberKnife{sup ®} was optically analyzed every 0.1 s using a webcam and a calibrated grid on a motion phantom whose motion was in accordance with three pattern waves (cosine, typical free-breathing, and minimum jerk theoretical wave models) for the clinically relevant superior–inferior directions from six volunteers assessed on the same node of the same isocentric plan. Results: Tracking discrepancy from the center of the grid to the beam projection was evaluated. The minimum jerk theoretical wave reduced the maximum-peak amplitude of radial tracking discrepancy compared with that of the waveforms modeled by cosine and typical free-breathing model by 22% and 35%, respectively, and provided smooth tracking for radial direction. Motion tracking constancy as indicated by radial tracking discrepancy affected by respiratory phase was improved in the minimum jerk theoretical model by 7.0% and 13% compared with that of the waveforms modeled by cosine and free-breathing model, respectively. Conclusions: The minimum jerk theoretical respiratory wave can achieve smooth tracking by CyberKnife{sup ®} and may provide patient-specific respiratory modeling, which may be useful for respiratory training and coaching, as well as quality assurance of the mechanical CyberKnife{sup ®} robotic trajectory.
For a stand-alone retail building, a primary school, and a secondary school in each of the 16 California climate zones, the EnergyPlus building energy simulation model was used to estimate how minimum mechanical ventilation rates (VRs) affect energy use and indoor air concentrations of an indoor-generated contaminant. The modeling indicates large changes in heating energy use, but only moderate changes in total building energy use, as minimum VRs in the retail building are changed. For example, predicted state-wide heating energy consumption in the retail building decreases by more than 50% and total building energy consumption decreases by approximately 10% as the minimum VR decreases from the Title 24 requirement to no mechanical ventilation. The primary and secondary schools have notably higher internal heat gains than in the retail building models, resulting in significantly reduced demand for heating. The school heating energy use was correspondingly less sensitive to changes in the minimum VR. The modeling indicates that minimum VRs influence HVAC energy and total energy use in schools by only a few percent. For both the retail building and the school buildings, minimum VRs substantially affected the predicted annual-average indoor concentrations of an indoor generated contaminant, with larger effects in schools. The shape of the curves relating contaminant concentrations with VRs illustrate the importance of avoiding particularly low VRs.