Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “microscope”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Refined tip preparation by electrochemical etching and ultrahigh vacuum treatment to obtain atomically sharp tips for scanning tunneling microscope and atomic force microscope

A modification of the common electrochemical etching setup is presented. The described method reproducibly yields sharp tungsten tips for usage in the scanning tunneling microscope and tuning fork atomic force microscope. In situ treatment under ultrahigh vacuum (p {<=}10{sup -10} mbar) conditions for cleaning and fine sharpening with minimal blunting is described. The structure of the microscopic apex of these tips is atomically resolved with field ion microscopy and cross checked with field emission.

36 MATERIALS SCIENCE↗

A high-pressure atomic force microscope for imaging in supercritical carbon dioxide

A high-pressure atomic force microscope (AFM) that enables in-situ, atomic scale measurements of topography of solid surfaces in contact with supercritical CO2 (scCO2) fluids has been developed. This apparatus overcomes the pressure limitations of the hydrothermal AFM and is designed to handle pressures up to 100 atm at temperatures up to ~ 350 K. A standard optically-based cantilever deflection detection system was chosen. When imaging in compressible supercritical fluids such as scCO2, precise control of pressure and temperature in the fluid cell is the primary technical challenge. Noise levels and imaging resolution depend on minimization of fluid density fluctuations that change the fluid refractive index and hence the laser path. We demonstrate with our apparatus in-situ atomic scale imaging of a calcite (CaCO3) mineral surface in scCO2; both single, monatomic steps and dynamic processes occurring on the (10¯14) surface are presented. This new AFM provides unprecedented in-situ access to interfacial phenomena at solid-fluid interfaces under pressure.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Quantitative Phase Imaging with a Scanning Transmission X-Ray Microscope

We obtain quantitative phase reconstructions from differential phase contrast images obtained with a scanning transmission x-ray microscope and 2.5 keV x rays. The theoretical basis of the technique is presented along with measurements and their interpretation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optical imaging analysis of microscopic radiation dose gradients in Gafchromic EBT film using a digital microscope

By providing superior localization and immobilization, stereotactic radiosurgery (SRS) is capable of delivering millimeter spheres of dose to intracranial targets with submillimeter precision. Several authors have proposed new SRS solutions to dramatically reduce beam penumbra to hundreds of microns. These solutions require new quality assurance methods capable of penumbra measurement at the micron scale. This article examines the capability of a digital microscope, with translation stage and associated software, to resolve dose gradients in Gafchromic EBT film at this level. To produce very steep penumbra, films were irradiated in phantom beneath pinhole collimators using lower energy x rays (100 kVp, 300 kVp, and Iridium-192) and minimal geometric penumbra contribution. For film analysis, a method was developed which improved the signal to noise ratio by finding the center of the irradiation spot, generating several radial dose profiles and averaging these to obtain the final off-axis dose profile. Optical density was converted to dose using a calibration curve. The experimentally determined off-axis dose profiles were compared with MCNP Monte Carlo simulations which replicated the irradiation geometry and served to validate our measured data. The measured 80%-20% penumbral widths were 46 {mu}m{+-}26 {mu}m (100 kVp, 2 mm field size), 69 {mu}m{+-}27 {mu}m (300 kVp, 2 mm field size), and 241 {mu}m{+-}31 {mu}m (Ir-192, 1 mm field size). These penumbral widths agreed with Monte Carlo simulations within experimental uncertainty. Our findings suggest that reading Gafchromic EBT films using a digital microscope with translation stage is suitable for the quality assurance of very sharp penumbra able to resolve gradients to within at least 30 {mu}m.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Electron Microscopic Evaluation and Fission Product Identification of Irradiated TRISO Coated Particles from the AGR-1 Experiment: A Preliminary Review

Post-irradiation examination of coated particle fuel from the AGR-1 experiment is in progress at Idaho National Laboratory and Oak Ridge National Laboratory. In this paper a brief summary of results from characterization of microstructures in the coating layers of selected irradiated fuel particles with burnup of 11.3% and 19.3% FIMA will be given. The main objectives of the characterization were to study irradiation effects, fuel kernel porosity, layer debonding, layer degradation or corrosion, fission-product precipitation, grain sizes, and transport of fission products from the kernels across the TRISO layers. Characterization techniques such as scanning electron microscopy, transmission electron microscopy, energy dispersive spectroscopy, and wavelength dispersive spectroscopy were used. A new approach to microscopic quantification of fission-product precipitates is also briefly demonstrated. Microstructural characterization focused on fission-product precipitates in the SiC-IPyC interface, the SiC layer and the fuel-buffer interlayer. The results provide significant new insights into mechanisms of fission-product transport. Although Pd-rich precipitates were identified at the SiC-IPyC interlayer, no significant SiC-layer thinning was observed for the particles investigated. Characterization of these precipitates highlighted the difficulty of measuring low concentrations of Ag in precipitates with significantly higher concentrations of Pd and U. Different approaches to resolving this problem are discussed. An initial hypothesis is provided to explain fission-product precipitate compositions and locations. No SiC phase transformations were observed and no debonding of the SiC-IPyC interlayer as a result of irradiation was observed for the samples investigated. Lessons learned from the post-irradiation examination are described and future actions are recommended.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Performance and characterization of the prototype nm-scale spatial resolution scanning multilayer Laue lenses microscope

Synchrotron based x-ray microscopy established itself as a prominent tool for noninvasive investigations in many areas of science and technology. Many facilities around the world routinely achieve sub-micrometer resolution with a few instruments capable of imaging with the spatial resolution better than 100 nm. With an ongoing effort to push the 2D/3D resolution down to 10 nm in the hard x-ray regime both fabrication of the nano-focusing optics and stability of a microscope become extremely challenging. In this work we present our approach to overcome technical challenges on the path towards high spatial resolution hard x-ray microscopy and demonstrate the performance of a scanning fluorescence microscope equipped with the multilayer Laue lenses focusing optics.

36 MATERIALS SCIENCE↗

Probing the limits of Si:P δ -doped devices patterned by a scanning tunneling microscope in a field-emission mode

Recently, a single atom transistor was deterministically fabricated using phosphorus in Si by H-desorption lithography with a scanning tunneling microscope (STM). This milestone in precision, achieved by operating the STM in the conventional tunneling mode, typically utilizes slow (∼102 nm2/s) patterning speeds. By contrast, using the STM in a high-voltage (>10 V) field-emission mode, patterning speeds can be increased by orders of magnitude to ≳104 nm2/s. We show that the rapid patterning negligibly affects the functionality of relatively large micron-sized features, which act as contacting pads for these devices. For nanoscale structures, we show that the resulting electrical transport is consistent with the donor incorporation chemistry constraining the electrical dimensions to a scale of 10 nm even though the pattering spot size is 40 nm.

Rudolph, M.↗

Microscopic origin of volume modulus inflation

High-scale string inflationary models are in well-known tension with low-energy supersymmetry. A promising solution involves models where the inflaton is the volume of the extra dimensions so that the gravitino mass relaxes from large values during inflation to smaller values today. We describe a possible microscopic origin of the scalar potential of volume modulus inflation by exploiting non-perturbative effects, string loop and higher derivative perturbative corrections to the supergravity effective action together with contributions from anti-branes and charged hidden matter fields. We also analyse the relation between the size of the flux superpotential and the position of the late-time minimum and the inflection point around which inflation takes place. We perform a detailed study of the inflationary dynamics for a single modulus and a two moduli case where we also analyse the sensitivity of the cosmological observables on the choice of initial conditions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Microscopic model approach to (n,xn) pre-equilibrium reactions for medium-energy neutrons

We report on microscopic model calculations of the first step of direct pre-equilibrium (n,xn) emission in neutron interaction with {sup 90}Zr and {sup 208}Pb below 20 MeV. Our model is based on both an accurate description of the target excited states, provided by the self-consistent random-phase approximation (RPA) method implemented with the Gogny D1S force, and well-established in-medium two-body forces to represent the residual nucleon-nucleon interaction for the inelastic processes. Two goals have been achieved: The present microscopic approach provides a unified description of collective state excitations and the pre-equilibrium one-step process, and our reaction model reproduces the available data fairly well, without any parameter adjustment.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Search for microscopic black holes in a like-sign dimuon final state using large track multiplicity with the ATLAS detector

A search is presented for microscopic black holes in a like-sign dimuon final state in proton-proton collisions at $ \sqrt{s}$=8 TeV. The data were collected with the ATLAS detector at the Large Hadron Collider in 2012 and correspond to an integrated luminosity of 20.3 fb -1 . Using a high track multiplicity requirement, 0.6±0.2 background events from Standard Model processes are predicted and none observed. This result is interpreted in the context of low-scale gravity models and 95% C.L. lower limits on microscopic black hole masses are set for different model assumptions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Stanford Nanocharacterization Laboratory (SNL) and Recent Applications of an Aberration-Corrected Environmental Transmission Electron Microscope

Here, this article describes the establishment, over a period of 10 years or so, of a multi-user, institution-wide facility for the characterization of materials and devices at the nanoscale. Emphasis is placed on the type of equipment that we have found to be most useful for our users, and the business strategy that maintains its operations. A central component of our facility is an aberration-corrected environmental transmission electron microscope and its application is summarized in the studies of plasmon energies of silver nanoparticles, the band gap of PbS quantum dots, atomic site occupancy near grain boundaries in yttria stabilized zirconia, the lithiation of silicon nanoparticles, in situ observations on carbon nanotube oxidation and the electron tomography of varicella zoster virus nucleocapsids.

bio-inspired↗

Direct Nanoscale Characterization of Deep Levels in AgCuInGaSe 2 Using Electron Energy–Loss Spectroscopy in the Scanning Transmission Electron Microscope

A new experimental framework for the characterization of defects in semiconductors is demonstrated. Through the direct, energy-resolved correlation of three analytical techniques spanning six orders of magnitude in spatial resolution, a critical mid-bandgap electronic trap level (E V + 0.56 eV) within Ag 0.2 Cu 0.8 In 1–x Ga x Se 2 is traced to its nanoscale physical location and chemical source. This is achieved through a stepwise, site-specific correlated characterization workflow consisting of device-scale (≈1 mm 2 ) deep level transient spectroscopy (DLTS) to survey the traps present, scanning probe–based DLTS (scanning-DLTS) for mesoscale-resolved (hundreds of nanometers) mapping of the target trap state’s spatial distribution, and scanning transmission electron microscope based electron energy-loss spectroscopy (STEM-EELS) and X-ray energy-dispersive spectroscopy for nanoscale energy-, structure, and chemical-resolved investigation of the defect source. Furthermore, this first demonstration of the direct observation of sub-bandgap defect levels via STEM-EELS, combined with the DLTS methods, provides strong evidence that the longsuspected Cu In/Ga substitutional defects are indeed the most likely source of the E V + 0.56 eV trap state and serves as a key example of this approach for the fundamental identification of defects within semiconductors, in general.

14 SOLAR ENERGY↗