Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “microimaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Quantitative impact of changes in marrow cellularity, skeletal size, and bone mineral density on active marrow dosimetry based upon a reference model

Purpose The hematopoietically active tissues of skeletal bone marrow are a prime target for computational dosimetry given potential risks of leukemia and, at higher dose levels, acute marrow toxicity. The complex three‐dimensional geometry of trabecular spongiosa, however, complicates schema for dose assessment in such a way that only a few reference skeletal models have been developed to date, and which are based upon microimaging of a limited number of cadaveric bone spongiosa cores. The question then arises as to what degree of accuracy is achievable from reference skeletal dose models when applied to individual patients or specific exposed populations? Methods Patient variability in marrow dosimetry were quantified for three skeletal sites — the ribs, lumbar vertebrae, and cranium — for the beta‐emitters 45 Ca, 153 Sm, and 90 Y, and the alpha‐particle emitters 223 Ra, 219 Rn, and 215 Po, the latter two being the immediate progeny of the former. For each radionuclide and bone site, three patient parameters were altered from their values in the reference model: (1) bone size as a surrogate for patient stature, (2) marrow cellularity as a surrogate for age‐ or disease‐related changes in marrow adiposity, and (3) the trabecular bone volume fraction as a surrogate for bone mineral density. Marrow dose variability is expressed as percent differences in the radionuclide S value given by the reference model and the patient‐parameterized model. The impact of radionuclide biokinetics on marrow dosimetry was not considered. Results Variations in overall bone size play a very minor role in active marrow dose variability. Marrow cellularity is a significant factor in dose variability for active marrow self‐irradiation, but it plays no role for radionuclides localized to the trabecular bone matrix. Variations in trabecular bone volume fractions impact the active marrow dose variability for short‐range particle emitters 45 Ca, 223 Ra, 219 Rn, and 215 Po in the vertebrae and ribs, skeletal sites with small spongiosa proportions of trabecular bone. In the cranium, with its relative high proportion of trabecular bone, significant differences in marrow dosimetry from the reference model were noted for all radionuclides. Conclusions Skeletal models of active marrow dosimetry should be more fully parameterized to permit closer matching to patient bone density and marrow cellularity, particularly when considering short‐range particle emitters localized to either the bone trabeculae or active marrow, respectively.

Geyer, Amy M.↗

Computed tomography of amyloid plaques in a mouse model of Alzheimers disease using diffraction enhanced imaging

Our understanding of early development in Alzheimer's disease (AD) is clouded by the scale at which the disease progresses; amyloid beta (A{beta}) plaques, a hallmark feature of AD, are small ({approx} 50 {micro}m) and low contrast in diagnostic clinical imaging techniques. Diffraction enhanced imaging (DEI), a phase contrast x-ray imaging technique, has greater soft tissue contrast than conventional radiography and generates higher resolution images than magnetic resonance microimaging. Thus, in this proof of principle study, DEI in micro-CT mode was performed on the brains of AD-model mice to determine if DEI can visualize A{beta} plaques. Results revealed small nodules in the cortex and hippocampus of the brain. Histology confirmed that the features seen in the DEI images of the brain were A{beta} plaques. Several anatomical structures, including hippocampal subregions and white matter tracks, were also observed. Thus, DEI has strong promise in early diagnosis of AD, as well as general studies of the mouse brain.

60 APPLIED LIFE SCIENCES↗

Diffusion and Adsorption of 2-Methylpentane and 3-Methylpentane in MFI-Type Zeolite Crystals

Due to the intimate contact of guest molecules with the inner surface of microporous adsorbents, slight changes in the structure of the guest molecules may lead to remarkable changes in their microdynamics. As an impressive example, in this work, diffusion measurements via IR microimaging (IRM) show that the transport diffusivity of 2-methylpentane (2MP) exceeds the value attained for 3-methylpentane (3MP) by a factor of 2−4.5 in silicalite- 1, an MFI-type zeolite crystal and a technically relevant porous host system. This experimental finding is rationalized by comparison with the outcome of dynamically corrected transition state theory (dcTST) simulations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Diffusion in biofilms respiring on electrodes

The goal of this study was to measure spatially and temporally resolved effective diffusion coefficients (De) in biofilms respiring on electrodes. Two model electrochemically active biofilms, Geobacter sulfurreducens PCA and Shewanella oneidensis MR-1, were investigated. A novel nuclear magnetic resonance microimaging perfusion probe capable of simultaneous electrochemical and pulsed-field gradient nuclear magnetic resonance (PFG-NMR) techniques was used. PFG-NMR allowed for noninvasive, nondestructive, high spatial resolution in situ De measurements in living biofilms respiring on electrodes. The electrodes were polarized so that they would act as the sole terminal electron acceptor for microbial metabolism. We present our results as both two-dimensional De heat maps and surface-averaged relative effective diffusion coefficient (Drs) depth profiles. We found that (1) Drs decreases with depth in G. sulfurreducens biofilms, following a sigmoid shape; (2) Drs at a given location decreases with G. sulfurreducens biofilm age; (3) average De and Drs profiles in G. sulfurreducens biofilms are lower than those in S. oneidensis biofilms—the G. sulfurreducens biofilms studied here were on average 10 times denser than the S. oneidensis biofilms; and (4) halting the respiration of a G. sulfurreducens biofilm decreases the De values. Density, reflected by De, plays a major role in the extracellular electron transfer strategies of electrochemically active biofilms.

59 BASIC BIOLOGICAL SCIENCES↗

Metabolic spatial variability in electrode-respiring Geobacter sulfurreducens biofilms

Certain bacteria are capable of transferring electrons derived from respiratory metabolism to solid extracellular electron-accepting materials1-4. This ability allows the organisms to use conductive substrata as their sole electron sink, generating electricity that is available for practical applications5-7. Geobacter is a biofilm-forming genus capable of this extracellular electron transfer8-11. Evidence in the literature suggests that Geobacter cells produce a conductive matrix to gain access to electron-accepting surfaces12,13. It has been hypothesized that cells that are more than tens of microns from the electron-accepting surface cannot respire because of electrical resistance in the matrix and thus remain metabolically inactive14-16. To test this hypothesis, we sought to determine whether the entire biofilm remains metabolically active and able to respire on an electron-accepting surface as the biofilm thickness increases. We developed and used a novel electrochemical-nuclear magnetic resonance (EC-NMR) microimaging system capable of sustaining an electrochemically active biofilm on a polarized electrode inside a superconducting magnet, allowing for simultaneous NMR and electrochemical investigation of a biofilm for the first time. Here, we show that Geobacter biofilms can grow to several hundred microns thick while respiring on an electrode and that the top of the biofilm remains metabolically active. This is only possible if the cells near the top are able to transfer electrons through the initial biofilm matrix to the electrode. We used X-ray absorption spectroscopy to verify electron transfer to uranium ions by metabolically active cells near the top of the biofilm. Our results reveal that extracellular electron transfer is not prevented by electrical resistance, even when the biofilm is hundreds of microns thick. Furthermore, the electron donor may be the limiting factor for respiration and the base of the biofilm may be less active despite being in close proximity to the electrode. Long-range electron transfer across metabolically inactive regions within Geobacter biofilms adds a novel facet to our comprehension of electrochemically active biology.

ANODE↗

Multiscale investigation of the mechanism of biomass deconstruction in the dimethyl isosorbide/water Co-solvent pretreatment system

In the context of promoting a circular bioeconomy, the development of green and efficient lignocellulosic biomass pretreatment technologies so as to realize high value-added biomass utilization is of intense interest. We demonstrated the potential of the bio-based green solvent dimethyl isosorbide (DMI) for the fractionation of Eucalyptus biomass with excellent performance. Here, to investigate the mechanisms involved in biomass fractionation, microimaging and microspectroscopic techniques were employed together with molecular dynamics (MD) simulation and COSMO-RS quantum chemical calculations to derive multiscale information. Both the microstructure and regional chemistry of the cell wall vary significantly with the volume ratio of DMI/H 2 O. The strongest effects were found at DMI/H 2 O = 9:1 and showed visible cell wall tearing cracks and cell wall deformation and collapse as well as the lowest values of cell wall thickness and circularity. From the MD simulations, lignin exhibits collapsed-like structure in pure H 2 O with low solvent accessibility surface area (SASA) and radius of gyration (R g ). In contrast, lignin in DMI/H 2 O shows extended structure with high SASA and solvent interactions dominated by van der Waals forces, with maximal contact in the 9:1 (v/v) system. Further, the COSMO-RS calculated sigma (σ-) potential suggests the intermolecular interactions in DMI and DMI/H 2 O co-solvent are weak, leading to stronger interaction with lignin and correspondingly higher lignin dissolution. The radial distribution functions and σ-potential all show that again DMI/H 2 O at 9:1 is an optimal volume ratio for high lignin dissolution. Finally, this study provides a solvent-ratio dependent mechanism for the action of polar aprotic solvents in the deconstruction of biomass.

09 BIOMASS FUELS↗

Correction of Spherical Aberration in Grazing-Incidence X-ray Optics by Combination of Spherical-Concave Mirrors

In grazing-incidence total-reflection mirror optics for x-rays, spherical aberrations and coma are the most serious aberrations for microfocusing and microimaging. High-resolution imaging is believed to be possible only when an aspherical mirror system is used. However, the spherical aberrations of a spherical-concave mirror in a grazing-incidence condition can be eliminated by sequential reflection of spherical mirrors of similar shapes. A sub-micrometer one-dimensional focusing is easily achieved by the spherical-aberration-corrected tandem-spherical mirror optics. By configuring four spherical mirrors in an analogy of the crossed mirror optics (Kirkpatrick-Baez optics), it is possible to achieve sub-micrometer focused beam size in the hard x-ray region. Preliminary experiments on x-ray microfocusing have been carried out at beamline 20XU of SPring-8, and a 0.5 {mu}mx0.4 {mu}m beam size was achieved at 8 keV.

07 ISOTOPE AND RADIATION SOURCES↗

X-ray microlaminography with polycapillary optics

We demonstrate layer-by-layer x-ray microimaging using polycapillary optics. The depth resolution is achieved without sample or source rotation and in a way similar to classical tomography or laminography. The method takes advantage from large angular apertures of polycapillary optics and from their specific microstructure, which is treated as a coded aperture. The imaging geometry is compatible with polychromatic x-ray sources and with scanning and confocal x-ray fluorescence setups.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Utah FORGE: Well 16B(78)-32 Logs from Schlumberger Technologies

This dataset is a collection of well logs provided by Schlumberger Technologies from the Utah FORGE well 16B(78)-32 drilling project. Information here includes critical borehole information collected by an ultrasonic borehole imager (UBI) and a fullbore formation microimager (FMI). Well 16B(78)-32 serves as the production well for reservoir creation, fluid circulation, and demonstration of heat extraction for the FORGE project. It has been drilled as a doublet approximately 300 feet parallel to and above the injection well 16A(78)-32. The total depth measured 10,947 feet and the vertical depth measured 8,357 feet.

11.5 inch intermediate casing logs↗

Modeling Substrate Utilization, Metabolite Production, and Uranium Immobilization in Shewanella oneidensis Biofilms

In this study, we developed a two-dimensional mathematical model to predict substrate utilization and metabolite production rates in Shewanella oneidensis MR-1 biofilm in the presence and absence of uranium (U). In our model, lactate and fumarate are used as the electron donor and the electron acceptor, respectively. The model includes the production of extracellular polymeric substances (EPS). The EPS bound to the cell surface and the EPS distributed in the biofilm were considered bound EPS (bEPS) and loosely associated EPS (laEPS), respectively. COMSOL ® Multiphysics finite element analysis software was used to solve the model numerically (model file provided in the Supplementary Material). The input variables of the model were the lactate and fumarate concentrations, cell density, EPS density, half saturation constant for fumarate, and diffusion coefficients of the substrates and metabolites. To estimate unknown parameters and calibrate the model, we used a custom designed biofilm reactor placed inside a nuclear magnetic resonance (NMR) microimaging and spectroscopy system and measured substrate utilization and metabolite production rates. From these data we estimated the yield coefficients, maximum substrate utilization rate, half saturation constant for lactate, stoichiometric ratio of fumarate and acetate to lactate and stoichiometric ratio of succinate to fumarate. These parameters are critical to predicting the activity of biofilms and are not available in the literature. Lastly, the model was used to predict uranium immobilization in S. oneidensis MR-1 biofilms by considering reduction and adsorption processes in the cells and in the EPS. We found that the majority of immobilization was due to cells, and that EPS were less efficient at immobilizing U. Furthermore, most of the immobilization occurred within the top 10 µm of the biofilm. To the best of our knowledge, this research is one of the first biofilm immobilization mathematical models based on experimental observation. It has the ability to predict the relative contributions to U immobilization of laEPS, bEPS and cells.

59 BASIC BIOLOGICAL SCIENCES↗

Classifying forest and nonforest land on space photographs

Although the research reported is in its preliminary stages, results show that: (1) infrared color film is the best single multiband sensor available; (2) there is a good possibility that forest can be separated from all nonforest land uses by microimage evaluation techniques on IR color film coupled with B/W infrared and panchromatic films; and (3) discrimination of forest and nonforest classes is possible by either of two methods: interpreters with appropriate viewing and mapping instruments, or programmable automatic scanning microdensitometers and automatic data processing.

Aldrich, R. C.↗

Gravitational microlensing at large optical depth

A large number of numerical models of gravitational microlensing by stars in the lensing galaxy have been calculated, and properties of the models are described. The expected light intensity variations are more rapid when optical depth to microlensing is large, but the time scale is a few years in the best cases, and much longer in a typical case. However, microlensing introduces considerable scatter, up to two or three orders of magnitude, to the intensity of macroimages expected at any given time, and this may considerably complicate the analysis of the observed lenses. It is shown that macroimage is surrounded with a faint 'halo' made of a large number of microimages from individual stars with average surface brightness falling off as R to the -4th. It is also shown that a high surface mass density of continuously distributed matter may affect very strongly properties of microlensing, making possible very large declines in observed intensity, up to two or three orders of magnitude.

Paczynski, B.↗

Random scattering approach to gravitational microlensing

Small random deflections of a narrow beam of radiation due to gravitational scattering by stars randomly distributed within the deflector plane are considered. Using a Fouriere transform method, the probability of scattering is obtained as a function of scattering angle for an arbitrary number of stars with an arbitrary distribution of masses. The probability density, expressed in proper units, depends on one parameter only: the effective number of stars. At small scattering angles the density is a Gaussian, and at large angles it falls off as the scattering angle to the minus fourth power. The probability distribution for scatterings is simply related to the angular distribution of the surface brightness of a macroimage, averaged over many microimages. The isophotes are ellipses, with the ratio of the major axis to the minor axis, determined by the dimensionless surface mass density and the shear of the lensing system. The number of stars that has to be included in the modeling of microlensing is proportional to the amplification due to the macrolens, and to the square of the dimensionless surface mass density.

Katz, N.↗

Caustic-induced features in microlensing magnification probability distributions

Numerical simulations have uncovered a previously unrecognized 'bump' in the macroimage magnification probabilities produced by a planar distribution of point masses. The result could be relevant to cases of microlensing by star fields in single galaxies, for which this lensing geometry is an excellent approximation. The bump is produced by bright pairs of microimages formed by sources lying near the caustics of the lens. The numerically calculated probabilities for the magnifications in the range between 3 and 30 are significantly higher than those given by the asymptotic relation derived by Schneider. The bump present in the two-dimensional lenses appears not to exist in the magnification probability distribution produced by a fully three-dimensional lens.

Rauch, Kevin P.↗

An efficient method to compute microlensed light curves for point sources

We present a method to compute microlensed light curves for point sources. This method has the general advantage that all microimages contributing to the light curve are found. While a source moves along a straight line, all micro images are located either on the primary image track or on the secondary image tracks (loops). The primary image track extends from - infinity to + infinity and is made of many sequents which are continuously connected. All the secondary image tracks (loops) begin and end on the lensing point masses. The method can be applied to any microlensing situation with point masses in the deflector plane, even for the overcritical case and surface densities close to the critical. Furthermore, we present general rules to evaluate the light curve for a straight track arbitrary placed in the caustic network of a sample of many point masses.

Witt, Hans J.↗

Laser Time-of-Flight Mass Spectrometry for Space

A miniature reflection time-of-flight mass spectrometer for in situ planetary surface analysis is described. The laser ablation mass spectrometer (LAMS) measures the regolith's elemental and isotopic composition without high-voltage source extraction or sample preparation. The compact size (< 2 x 10(exp 3) cubic cm) and low mass (approximately 2 kg) of LAMS, due to its fully coaxial design and two-stage reflectron, fall within the strict resource limitations of landed science missions to solar system bodies. A short-pulse laser focused to a spot with a diameter approximately 30-50 micrometers is used to obtain microscopic surface samples. Assisted by a microimager, LAMS can interactively select and analyze a range of compositional regions (with lateral motion) and with repeated pulses can access unweathered, subsurface materials. The mass resolution is calibrated to distinguish isotopic peaks at unit masses, and detection limits are on resolved to a few ppm. The design and calibration method of a prototype LAMS device is described, which include the development of preliminary relative sensitivity coefficients for major element bulk abundance measurements.

Brinckerhoff, W. B.↗

Lunar and Planetary Science XXXV: Missions and Instruments: Hopes and Hope Fulfilled

The titles in this section include: 1) Mars Global Surveyor Mars Orbiter Camera in the Extended Mission: The MOC Toolkit; 2) Mars Odyssey THEMIS-VIS Calibration; 3) Early Science Operations and Results from the ESA Mars Express Mission: Focus on Imaging and Spectral Mapping; 4) The Mars Express/NASA Project at JPL; 5) Beagle 2: Mission to Mars - Current Status; 6) The Beagle 2 Microscope; 7) Mars Environmental Chamber for Dynamic Dust Deposition and Statics Analysis; 8) Locating Targets for CRISM Based on Surface Morphology and Interpretation of THEMIS Data; 9) The Phoenix Mission to Mars; 10) First Studies of Possible Landing Sites for the Phoenix Mars Scout Mission Using the BMST; 11) The 2009 Mars Telecommunications Orbiter; 12) The Aurora Exploration Program - The ExoMars Mission; 13) Electron-induced Luminescence and X-Ray Spectrometer (ELXS) System Development; 14) Remote-Raman and Micro-Raman Studies of Solid CO2, CH4, Gas Hydrates and Ice; 15) The Compact Microimaging Spectrometer (CMIS): A New Tool for In-Situ Planetary Science; 16) Preliminary Results of a New Type of Surface Property Measurement Ideal for a Future Mars Rover Mission; 17) Electrodynamic Dust Shield for Solar Panels on Mars; 18) Sensor Web for Spatio-Temporal Monitoring of a Hydrological Environment; 19) Field Testing of an In-Situ Neutron Spectrometer for Planetary Exploration: First Results; 20) A Miniature Solid-State Spectrometer for Space Applications - Field Tests; 21) Application of Laser Induced Breakdown Spectroscopy (LIBS) to Mars Polar Exploration: LIBS Analysis of Water Ice and Water Ice/Soil Mixtures; 22) LIBS Analysis of Geological Samples at Low Pressures: Application to Mars, the Moon, and Asteroids; 23) In-Situ 1-D and 2-D Mapping of Soil Core and Rock Samples Using the LIBS Long Spark; 24) Rocks Analysis at Stand Off Distance by LIBS in Martian Conditions; 25) Evaluation of a Compact Spectrograph/Detection System for a LIBS Instrument for In-Situ and Stand-Off Detection; 26) Analysis of Organic Compounds in Mars Analog Samples; 27) Report of the Organic Contamination Science Steering Group; 28) The Water-Wheel IR (WIR) - A Contact Survey Experiment for Water and Carbonates on Mars; 29) Mid-IR Fiber Optic Probe for In Situ Water Detection and Characterization; 30) Effects of Subsurface Sampling & Processing on Martian Simulant Containing Varying Quantities of Water; 31) The Subsurface Ice Probe (SIPR): A Low-Power Thermal Probe for the Martian Polar Layered Deposits; 32) Deploying Ground Penetrating Radar in Planetary Analog Sites to Evaluate Potential Instrument Capabilities on Future Mars Missions; 33) Evaluation of Rock Powdering Methods to Obtain Fine-grained Samples for CHEMIN, a Combined XRD/XRF Instrument; 34) Novel Sample-handling Approach for XRD Analysis with Minimal Sample Preparation; 35) A New Celestial Navigation Method for Mars Landers; 36) Mars Mineral Spectroscopy Web Site: A Resource for Remote Planetary Spectroscopy.

Source record↗

NASA Tech Briefs, September 2012

Topics covered include: Beat-to-Beat Blood Pressure Monitor; Measurement Techniques for Clock Jitter; Lightweight, Miniature Inertial Measurement System; Optical Density Analysis of X-Rays Utilizing Calibration Tooling to Estimate Thickness of Parts; Fuel Cell/Electrochemical Cell Voltage Monitor; Anomaly Detection Techniques with Real Test Data from a Spinning Turbine Engine-Like Rotor; Measuring Air Leaks into the Vacuum Space of Large Liquid Hydrogen Tanks; Antenna Calibration and Measurement Equipment; Glass Solder Approach for Robust, Low-Loss, Fiber-to-Waveguide Coupling; Lightweight Metal Matrix Composite Segmented for Manufacturing High-Precision Mirrors; Plasma Treatment to Remove Carbon from Indium UV Filters; Telerobotics Workstation (TRWS) for Deep Space Habitats; Single-Pole Double-Throw MMIC Switches for a Microwave Radiometer; On Shaft Data Acquisition System (OSDAS); ASIC Readout Circuit Architecture for Large Geiger Photodiode Arrays; Flexible Architecture for FPGAs in Embedded Systems; Polyurea-Based Aerogel Monoliths and Composites; Resin-Impregnated Carbon Ablator: A New Ablative Material for Hyperbolic Entry Speeds; Self-Cleaning Particulate Prefilter Media; Modular, Rapid Propellant Loading System/Cryogenic Testbed; Compact, Low-Force, Low-Noise Linear Actuator; Loop Heat Pipe with Thermal Control Valve as a Variable Thermal Link; Process for Measuring Over-Center Distances; Hands-Free Transcranial Color Doppler Probe; Improving Balance Function Using Low Levels of Electrical Stimulation of the Balance Organs; Developing Physiologic Models for Emergency Medical Procedures Under Microgravity; PMA-Linked Fluorescence for Rapid Detection of Viable Bacterial Endospores; Portable Intravenous Fluid Production Device for Ground Use; Adaptation of a Filter Assembly to Assess Microbial Bioburden of Pressurant Within a Propulsion System; Multiplexed Force and Deflection Sensing Shell Membranes for Robotic Manipulators; Whispering Gallery Mode Optomechanical Resonator; Vision-Aided Autonomous Landing and Ingress of Micro Aerial Vehicles; Self-Sealing Wet Chemistry Cell for Field Analysis; General MACOS Interface for Modeling and Analysis for Controlled Optical Systems; Mars Technology Rover with Arm-Mounted Percussive Coring Tool, Microimager, and Sample-Handling Encapsulation Containerization Subsystem; Fault-Tolerant, Real-Time, Multi-Core Computer System; Water Detection Based on Object Reflections; SATPLOT for Analysis of SECCHI Heliospheric Imager Data; Plug-in Plan Tool v3.0.3.1; Frequency Correction for MIRO Chirp Transformation Spectroscopy Spectrum; Nonlinear Estimation Approach to Real-Time Georegistration from Aerial Images; Optimal Force Control of Vibro-Impact Systems for Autonomous Drilling Applications; Low-Cost Telemetry System for Small/Micro Satellites; Operator Interface and Control Software for the Reconfigurable Surface System Tri-ATHLETE; and Algorithms for Determining Physical Responses of Structures Under Load.

Source record↗