An MILP-Based Distributed Energy Management for Coordination of Networked Microgrids

An MILP-based distributed energy management for the coordination of networked microgrids is proposed in this paper. Multiple microgrids and the utility grid are coordinated through iteratively adjusted price signals. Based on the price signals received, the microgrid controllers (MCs) and distribution management system (DMS) update their schedules separately. Then, the price signals are updated according to the generation–load mismatch and distributed to MCs and DMS for the next iteration. The iteration continues until the generation–load mismatch is small enough, i.e., the generation and load are balanced under agreed price signals. Through the proposed distributed energy management, various microgrids and the utility grid with different economic, resilient, emission and socio-economic objectives are coordinated with generation–load balance guaranteed and the microgrid customers’ privacy preserved. In particular, a piecewise linearization technique is employed to approximate the augmented Lagrange term in the alternating direction method of multipliers (ADMM) algorithm. Thus, the subproblems are transformed into mixed integer linear programming (MILP) problems and efficiently solved by open-source MILP solvers, which would accelerate the adoption and deployment of microgrids and promote clean energy. The proposed MILP-based distributed energy management is demonstrated through various case studies on a networked microgrids test system with three microgrids.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Quantum microgrid state estimation

This paper investigates the feasibility and efficiency of quantum-circuit-based algorithms for microgrid state estimation. Here, our new contributions include: (1) a general quantum state estimation (GQSE) formulation is devised for swing-bus-contained microgrids through the quantized Gaussian–Newton iteration, (2) a preconditioned quantum linear solver (PQLS) is developed for tackling the ill-conditioned GQSE with limited quantum resources, and (3) an enhanced quantum state estimation (EQSE) algorithm is further established for hierarchical-control-based microgrids with exogenous disturbances. Extensive case studies demonstrate the correctness of GQSE, PQLS and EQSE in two typical microgrids. The robustness and convergence performance of EQSE are also verified.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Safe Reinforcement Learning-Based Transient Stability Control for Islanded Microgrids With Topology Reconfiguration

This paper proposes a safe reinforcement learning (RL)-based transient stability emergency control (TSEC) method for islanded microgrids. RL requires extensive interaction with the environment to learn control strategies, hence, a data-driven approach is used as a substitute for time-consuming time-domain simulation calculations. Deep sigma point processes (DSPP), which is a Gaussian process model, is utilized to predict the normal distribution of transient stability of microgrids and to construct a transient stability chance constraint. Reward-constrained policy optimization (RCPO) can simultaneously achieve objective prediction, policy learning, and constraint cost coefficient update across multiple timescales. RCPO interacts with the DSPP-based microgrid environment through a multi-process parallel manner, greatly increasing the training speed. Case studies on a real islanded microgrid demonstrate that the proposed method can efficiently and quickly obtain the optimal emergency control strategy while adhering to all hard constraints.

14 SOLAR ENERGY↗

Demand Estimation of Net Metered Loads for Microgrid Restoration

Microgrids can experience frequency instability while operating in the islanded mode due to a significant demand generation imbalance. Presence of net metered (NM) loads can further complicate accurate demand forecasting. For these loads only the net demand, difference of load demand and generation, is available. This paper presents the various stages observed during microgrid restoration with high penetration of NM loads. Disaggregation of demand and generation from the net metered time series is shown to be essential for accurate demand forecasting in each of these stages. A disaggregation approach is proposed using correlation in the net metered data. Time series analysis is then used to forecast the demand in each stage of the microgrid restoration process. A case study using demand and generation time series data from residential loads, shows that the proposed approach is significantly more accurate for demand forecasting than using only the net-metered time series.

demand forecasting, Microgrid, power system restor↗

A tool for assessing demand side management and operating strategies for isolated microgrids

Globally, power system operators are exploring ways to leverage the capabilities of smart meters to implement fine-grained demand side management (DSM). Here this paper presents a new simulation tool to evaluate operating strategies for smart-meter-enabled (SME) islanded microgrids being advanced for sustainable rural electrification in emerging economies. Based on MATLAB/Simulink, the tool's component-level models of small microgrids can be easily configured. Alternative rule-based operating strategies are implemented with controllable supply and storage components as well as other components driven by external factors (e.g., weather and time of day). To account for the wide range of possible operating conditions in real-world applications, statistical metrics can be evaluated using Monte Carlo (MC) methods based on user-defined, time-dependent probability distributions for demands, supplies, and environmental variables. Features of the tool are demonstrated with case studies for a representative microgrid in rural Rwanda.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Distribution System Congestion Management - A Survey of Reliable Integration for Aggregated Resources and Microgrids

Rising penetration of consumer-owned Distribution Grid Resources (DGRs), increasingly managed by third party aggregators and enrolled in grid services and wholesale market programs, can create localized congestion in distribution networks. Managing these constraints is challenging due to a persistent coordination and information gap: utilities are accountable for reliability and have network topology and state visibility, while aggregators control the DGR capability needed to relieve congestion. This survey synthesizes congestion management solutions for distribution systems with high DGR penetration, covering both market-based mechanisms (distribution level markets, locational pricing, flexibility auctions) and non-market-based solutions (network reconfiguration, direct DGR control, demand response, curtailment, etc.). The literature is organized across three decision horizons: long term planning, operational planning, and real-time operation. Special attention is devoted to emerging distribution system operator architectures and coordination frameworks spanning transmission system operators, aggregators, and microgrids. Drawing on recent case studies and implementations, we distill best practices, identify key technical and economic barriers, and outline research directions. The evidence points to a shift toward integrated congestion management that combines market signals with technical controls, enabled by improved monitoring, forecasting, and closed loop control capabilities.

Active Distribution Networks (ADN)↗

Instrumentation for Assessing DC Electrical Distribution Systems in Buildings

Direct current (DC) distribution systems is emerging as a favorable option over alternating current in buildings due to its energy and non-energy benefits (e.g., efficiency, resilience, safety). However, limited guidelines exist to evaluate the DC electrical distribution infrastructure. This paper aims to fill that gap by detailing our experience with metering a building-level electrical DC distribution system. Our case study is a DC microgrid at the Direct Energy Partners Research & Development facility located in Charlotte, North Carolina. This paper presents our approach, technical challenges, and lessons learned with DC metering and instrumentation.

buildings↗

Interconnection of Three Single-Phase Feeders in North America Distribution Systems

This paper proposes a solution for maintaining power balance within all three phases at residential level during islanded mode of operation. Grid abnormalities can lead to isolating the residential microgrid from the main grid, and as a result, distributed generation (DG) units take the full responsibility of supplying local loads. However, in such condition, some phases might face the challenge of meeting local load demand due to the lack of enough power generation, resulting in voltage drop and frequency variation across household loads. In order to resolve this issue, the proposed method in this paper seamlessly interconnects all three single-phase feeders during islanded mode and forms a unified single-phase residential microgrid. Consequently, the load demands in all three phases are met, leading to enhanced voltage and frequency profiles. For this purpose, a seamless transition algorithm is defined which monitors the system condition in real time, and coordinates the operation of all inverter-based DG units in residential microgrid accordingly during transitions. Case study results are provided to verify the validity of proposed method.

Pilehvar, Mohsen S.↗

INTEGRATION OF CONDUIT HYDROPOWER AND BATTERIES INTO IRRIGATION INFRASTRUCTURE

Irrigation districts, ditch companies, and other agricultural water providers across the West operate and maintain canals, ditches, and reservoirs that store and deliver water for agricultural production, municipal needs, and other purposes. Co-locating energy generation and storage with this infrastructure provides opportunities to improve resilience and reduce energy costs. This memo discusses two case studies of co-located infrastructure and their contexts. The first case study discusses the development of an integrated microgrid, hydropower, solar, and battery storage project in North Unit Irrigation District (NUID) in Oregon. The second case study discusses the development of a battery storage project in Tulelake Irrigation District (TID) in northern California. Together, these two projects demonstrate the potential for co-located energy and water infrastructure.

13 - HYDRO ENERGY↗

Optimal Electrification Using Renewable Energies: Microgrid Installation Model with Combined Mixture k-Means Clustering Algorithm, Mixed Integer Linear Programming, and Onsset Method

Optimal planning and design of microgrids are priorities in the electrification of off-grid areas. Indeed, in one of the Sustainable Development Goals (SDG 7), the UN recommends universal access to electricity for all at the lowest cost. Several optimization methods with different strategies have been proposed in the literature as ways to achieve this goal. This paper proposes a microgrid installation and planning model based on a combination of several techniques. The programming language Python 3.10 was used in conjunction with machine learning techniques such as unsupervised learning based on K-means clustering and deterministic optimization methods based on mixed linear programming. These methods were complemented by the open-source spatial method for optimal electrification planning: onsset. Four levels of study were carried out. The first level consisted of simulating the model obtained with a cluster, which is considered based on the elbow and k-means clustering method as a case study. The second level involved sizing the microgrid with a capacity of 40 kW and optimizing all the resources available on site. The example of the different resources in the Togo case was considered. At the third level, the work consisted of proposing an optimal connection model for the microgrid based on voltage stability constraints and considering, above all, the capacity limit of the source substation. Finally, the fourth level involved a planning study of electrification strategies based mainly on microgrids according to the study scenario. The results of the first level of study enabled us to obtain an optimal location for the centroid of the cluster under consideration, according to the different load positions of this cluster. Then, the results of the second level of study were used to highlight the optimal resources obtained and proposed by the optimization model formulated based on the various technology costs, such as investment, maintenance, and operating costs, which were based on the technical limits of the various technologies. In these results, solar systems account for 80% of the maximum load considered, compared to 7.5% for wind systems and 12.5% for battery systems. Next, an optimal microgrid connection model was proposed based on the constraints of a voltage stability limit estimated to be 10% of the maximum voltage drop. The results obtained for the third level of study enabled us to present selective results for load nodes in relation to the source station node. Finally, the last results made it possible to plan electrification using different network technologies and systems in the short and long term. The case study of Togo was taken into account. The various results obtained from the different techniques provide the necessary leads for a feasibility study for optimal electrification of off-grid areas using microgrid systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Retracted Article: Distributed energy management for networked microgrids in a three-phase unbalanced distribution network

Owing to increased penetration of three-phase and single-phase microgrids, distributed energy resources (DERs), and responsive loads, the maintenance of a three-phase balance by distribution networks is a significant challenge. Existing literature on distributed energy management for networked microgrids generally neglects the distribution network or employs a simplified phase balanced distribution network; thus, these evaluations are not applicable. Further, the underlying mutual coupling between the different phases of distribution feeders results in a more challenging situation. Here, to solve this issue, this study sought to propose distributed energy management based on a three-phase unbalanced distribution network. Various three-phase or single-phase microgrids, utility-owned DERs, and responsive loads were coordinated through iteratively adjusted price signals. Based on the price signals received, the microgrid controllers (MCs) and distribution management system (DMS) updated the schedules of the DERs and responsive loads under their jurisdiction separately. The price signals were then updated according to the generation-load mismatch at each node and distributed to the corresponding MCs and DMS for the next iteration. The iteration continued until a sufficiently small generation-load mismatch was achieved at all nodes, that is, a balanced generation and load at all nodes under the agreed price signals. Considering a three-phase unbalanced distribution network, the price signals were determined per phase per node. Overall, the proposed distributed energy management coordinates microgrids, utility-owned DERs, responsive loads with guaranteed network constraints, and preserves the privacy of microgrid customers. This distributed energy management method was further demonstrated through various case studies on a three-phase networked microgrid test system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Looking Beyond Bill Savings to Equity in Renewable Energy Microgrid Deployment

Microgrids powered by renewable energy can provide backup power to critical infrastructure during grid outages. These systems can also play an important role in advancing energy justice by providing economic, environmental, health, and resilience benefits for underserved communities. The value of microgrids is often measured by the economic savings and resilience provided, but there are other energy justice factors that should be considered. This paper describes a methodology for quantifying broader costs and benefits including utility bill savings, value of resilience, social cost of carbon, public health costs, and jobs associated with the construction and operation of microgrids. We evaluate these factors at three case study sites and find that including energy justice values in the cost-benefit analysis of microgrids can change investment decisions. When climate, health, resilience, and job creation are considered, cost-optimal microgrids include more renewable generation, leading to a 52-82% reduction in emissions and diesel fuel use. The net present values of the microgrids grow from negative $626,000-843,000 in the diesel only case to $10-16 million in the hybrid microgrid case and $12-19 million in the renewable microgrid case, indicating potential for greater microgrid deployment if energy justice values are incorporated in decision making. However, we also see large increases in capital expenses, which could limit deployment unless accompanied by innovative financing measures. These findings may be useful to communities as they seek to strengthen resilience to natural disasters while also improving public health, meeting climate goals, and providing economic opportunity for residents.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Comparison of Electromagnetic Transient and Phasor-based Simulation for the Stability of Grid-Forming-Inverter-based Microgrids

The increasing interest in studying feeder-level, inverter-based microgrids requires appropriate simulation methods that can effectively simulate the dynamics of distribution feeders that typically have thousands of nodes. To examine the accuracy of phasor-based simulation for the stability of feeder-level, inverter-based microgrids, a comparative study between electromagnetic transient (EMT) and phasor-based simulation was conducted. Case studies of a two-inverter small microgrid and a modified version of the IEEE 34-Node Test System that has seven grid-forming inverters show that phasor-based simulation agrees well with EMT simulation when the P-f droop gains of grid-forming inverter controllers are within normal ranges. However, under extremely high P-f droop gains, phasor-based simulation can result in over-optimistic stability results. This study provides insight into the applicability of phasor-based simulation for the stability of feeder-level, inverter-based microgrids.

Du, Wei↗

Smart Inverters for Seamless Reconnection of Isolated Residential Microgrids to Utility Grid

This paper proposes an approach to achieve seamless reconnection of isolated residential microgrids to utility grid. Any abnormal condition on the grid side results in isolating the residential microgrid from utility grid, and giving the full responsibility of supplying household loads to local distributed generation (DG) units. However, after resolving the abnormal condition on the grid side, the residential microgrid needs to seamlessly reconnect to the main grid. To this end, a seamless transition algorithm is presented which monitors the system condition in real time, and coordinates the operation of all inverter-based DG units in residential microgrid before reconnection to the main grid. A modified control scheme is proposed for single-phase inverters which turns them into smart inverters enable to interact with seamless transition algorithm. The proposed approach synchronizes each phase voltage with its respective grid-side voltage in order to seamlessly reconnect the residential microgrid to the main grid. Case study results are carried out in PSCAD/EMTDC environment to verify the validity of proposed method.

Pilehvar, Mohsen S.↗

Model-Free Dynamic Voltage Control of a Synchronous Generator-Based Microgrid

The main goal of this paper is to present a new dynamic voltage stability mechanism, based on model-free control (MFC), for effective control and coordination of synchronous generator (SG)-based reactive power resources in a microgrid setting. MFC has shown successful operation in various domains, and this paper presents its first use in the voltage stability of a power system. It is utilized as an online controller to achieve the dynamic voltage stability of a microgrid system under different disturbances and fault conditions. A 21-bus microgrid system fed by SG-based distributed energy resources (DERs) is considered as a use case study. The overall dynamic voltage stability of the microgrid system is investigated using time-domain dynamic simulations during emergency, hazard, and disaster events. Simulation results show that there are significant improvements and enhancements on the dynamic load bus voltage profiles of the microgrid system by the effective model-free control and coordination of the reactive power reserves of the SG-based DERs.

Hatipoglu, Kenan↗

High-Penetration Microgrids Providing Grid Stability Using Frequency Watt Control

The U.S. grid is rapidly transitioning towards utilizing inverter-based renewable energy resources such as solar, wind, and batteries, reducing the carbon emission footprint. Inverter-based microgrid control architectures remain a critical focus to address power system stability issues in future high penetration markets lacking spinning generation assets. Idaho National Laboratory (INL) is researching an active layered inverter based frequency-Watt control scheme that provides distribution level stability in high-penetration markets where grid inertia is lacking. Hardware in the loop case study was implemented using INL’s Microgrid Testbed to combat scalable frequency deviations ranging from 60 Hz down to 50 Hz initialized by a hydropower model implementing step loads using a 540-kW grid emulator. Our research findings demonstrate the importance of distribution level, inverter-based active frequency-Watt controls utilizing a battery energy storage system (BESS) to provide adequate frequency support at the point of common coupling without major power infrastructure upgrades.