Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “microfluidic valve”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

NASA Tech Briefs, March 2007

Topics include: Advanced Systems for Monitoring Underwater Sounds; Wireless Data-Acquisition System for Testing Rocket Engines; Processing Raw HST Data With Up-to-Date Calibration Data; Mobile Collection and Automated Interpretation of EEG Data; System for Secure Integration of Aviation Data; Servomotor and Controller Having Large Dynamic Range; Digital Multicasting of Multiple Audio Streams; Translator for Optimizing Fluid-Handling Components; AIRSAR Web-Based Data Processing; Pattern Matcher for Trees Constructed From Lists; Reducing a Knowledge-Base Search Space When Data Are Missing; Ground-Based Correction of Remote-Sensing Spectral Imagery; State-Chart Autocoder; Pointing History Engine for the Spitzer Space Telescope; Low-Friction, High-Stiffness Joint for Uniaxial Load Cell; Magnet-Based System for Docking of Miniature Spacecraft; Electromechanically Actuated Valve for Controlling Flow Rate; Plumbing Fixture for a Microfluidic Cartridge; Camera Mount for a Head-Up Display; Core-Cutoff Tool; Recirculation of Laser Power in an Atomic Fountain; Simplified Generation of High-Angular-Momentum Light Beams; Imaging Spectrometer on a Chip; Interferometric Quantum-Nondemolition Single-Photon Detectors; Ring-Down Spectroscopy for Characterizing a CW Raman Laser; Complex Type-II Interband Cascade MQW Photodetectors; Single-Point Access to Data Distributed on Many Processors; Estimating Dust and Water Ice Content of the Martian Atmosphere From THEMIS Data; Computing a Stability Spectrum by Use of the HHT; Theoretical Studies of Routes to Synthesis of Tetrahedral N4; Estimation Filter for Alignment of the Spitzer Space Telescope; Antenna for Measuring Electric Fields Within the Inner Heliosphere; Improved High-Voltage Gas Isolator for Ion Thruster; and Hybrid Mobile Communication Networks for Planetary Exploration.

Source record↗

Continuous Counter‐Current Microfluidic Liquid–Liquid Extraction Achieved Using a Pair of Wettable Screen Meshes

Continuous counter‐current microfluidic liquid–liquid extraction performs separations by flowing immiscible liquids in opposing directions within a single flow channel. In principle, this flow arrangement enables a large number of theoretical separation units in a small footprint, without using interstage valving, pumping, and phase separation. Despite its potential for excellent separation performance, this microfluidic scheme rarely appears in literature due to the requirement for capillary forces to be greater than hydrodynamic forces for stable flow. We present a novel microfluidic device and flow approaches that overcome this force‐balance challenge, enabling stable, long‐duration continuous counter‐current flow. Additionally, we cover a suite of methodologies for quantifying the performance of the microfluidic device, revealing the number of theoretical equilibrium stages achieved. The enabling technologies include a woven mesh screen‐based microfluidic device architecture that is easily fabricated outside of a clean room, surface functionalization strategies to promote conjugate (organic/aqueous) wettability, flow approaches to eliminate bubbles and carryover, and computer‐aided flow automation with optical measurement of extraction performance. The reported experiments lasted for over 36 h, terminated only at experiment conclusion, where the device still exhibited good performance. Automated Raman spectroscopy was used for solute quantitation of the ternary system tert‐butanol in a toluene/water matrix, a ternary system that was specifically chosen to analyze the device's performance with a small solute partition ratio and to enable in‐line Raman measurements of solute concentrations in both phases. The microfluidic device possessed a 55 mm contact length and a 38.5 µL internal volume. During counter‐current flow, we observed approximately 37 equilibrium stages (37 ± 13) based on a best‐fit of the solute fraction remaining in the aqueous phase using a Kremser Group Method analysis.

36 MATERIALS SCIENCE↗

Microfluidic device for drug delivery

A microfluidic device is provided for delivering a drug to an individual. The microfluidic device includes a body that defines a reservoir for receiving the drug therein. A valve interconnects the reservoir to an output needle that is insertable into the skin of an individual. A pressure source urges the drug from the reservoir toward the needle. The valve is movable between a closed position preventing the flow of the drug from the reservoir to the output needle and an open position allowing for the flow of the drug from the reservoir to the output needle in response to a predetermined condition in the physiological fluids of the individual.

Beebe, David J.↗

Micro-Fluidic Device for Drug Delivery

A microfluidic device is provided for delivering a drug to an individual. The microfluidic device includes a body that defines a reservoir for receiving the drug therein. A valve interconnects the reservoir to an output needle that is insertable into the skin of an individual. A pressure source urges the drug from the reservoir toward the needle. The valve is movable between a closed position preventing the flow of the drug from the reservoir to the output needle and an open position allowing for the flow of the drug from the reservoir to the output needle in response to a predetermined condition in the physiological fluids of the individual.

Beebe, David J.↗

Silicone-Rubber Microvalves Actuated by Paraffin

Microvalves containing silicone-rubber seals actuated by heating and cooling of paraffin have been proposed for development as integral components of microfluidic systems. In comparison with other microvalves actuated by various means (electrostatic, electromagnetic, piezoelectric, pneumatic, and others), the proposed valves (1) would contain simpler structures that could be fabricated at lower cost and (2) could be actuated by simpler (and thus less expensive) control systems. Each valve according to the proposal would include a flow channel bounded on one side by a flat surface and on the other side by a curved surface defined by an arched-cross-section, elastic seal made of silicone rubber [polydimethylsilane (PDMS)]. The seal would be sized and shaped so that the elasticity of the PDMS would hold the channel open except when the seal was pressed down onto the flat surface to close the channel. The principle of actuation would exploit the fact that upon melting or freezing, the volume of a typical paraffin increases or decreases, respectively, by about 15 percent. In a valve according to the proposal, the seal face opposite that of the channel would be in contact with a piston-like plug of paraffin. In the case of a valve designed to be normally open at ambient temperature, one would use a paraffin having a melting temperature above ambient. The seal would be pushed against the flat surface to close the channel by heating the paraffin above its melting temperature. In the case of a valve designed to be normally closed at ambient temperature, one would use a paraffin having a melting temperature below ambient. The seal would be allowed to spring away from the flat surface to open the channel by cooling the paraffin below its melting temperature. The availability of paraffins that have melting temperatures from 70 to +80 C should make it possible to develop a variety of normally closed and normally open valves. The figure depicts examples of prototype normally open and normally closed valves according to the proposal. In each valve, an arch cross section defining a channel having dimensions of the order of tens of micrometers would be formed in a silicone-rubber sheet about 40 m thick. The silicone rubber sheet would be hermetically sealed to a lower glass plate that would define the sealing surface and to an upper glass plate containing a well. The well would be filled with paraffin and capped with a rigid restraining layer of epoxy. In the normally open valve, the paraffin would have a melting temperature above ambient (e.g., 40 C) and the wall of the well would be coated with a layer of titanium that would serve as an electric heater. In the normally closed valve, the paraffin would have a melting temperature below ambient (e.g.-5 C). Instead of a heater in the well, the normally closed valve would include a thermoelectric cooler on top of the epoxy cap.

Svelha, Danielle↗

Microscale device and method for purification of radiopharmaceuticals

A microfluidic chip device for the purification of radiochemical compounds includes a chip having an injection channel and intersecting branch channels with a plurality of valves are located along the injection channel and branch channels and configured to retain a plug of solution containing the radiochemical compound. The chip further includes a serpentine channel segment (for separation) coupled to the output of the injection channel. A high voltage power source advances the plug of solution through the purification region and into the downstream fraction collection channel. The chip includes a downstream fraction collection channel coupled to the serpentine channel segment and having an optical and radiation detection regions. One or more branch fraction channels intersect with the fraction collection channel and include valves located therein so that the radiochemical compound that is detected using a radiation detector is directed into the desired branch fraction channel for subsequent use.

Van Dam, R. Michael↗

Advancing Small Satellite Electronics Heritage for Microfluidic Biological Experiments

DLR's Eu:CROPIS (Euglena and Combined Regenerative Organic-Food Production in Space) mission, launching in 2017, will carry multiple biological payloads into a sun-synchronous orbit, including NASA Ames' PowerCell experiment. PowerCell will attempt to characterize the viability of synthetic biology at micro-g, Lunar, and Martian gravity levels. PowerCell experiment requirements demand an electronic system similar to previous microfluidic biology payloads, but with an expanded feature set. As such, the system was based on PharmaSat (Diaz-Aguado et al. 2009), a previous successful biology payload from NASA Ames, and improved upon. Newer, more miniaturized electronics allow for greater capability with a lower part count and smaller size. Two identical PowerCell enclosures will fly. Each enclosure contains two separate and identical experiments with a 48-segment optical density measurement system, grow light system, microfluidic system for nutrient delivery and waste flushing, plus thermal control and environmental sensing/housekeeping including temperature, pressure, humidity, and acceleration. Electronics consist of a single Master PCB that interfaces to the spacecraft bus and regulates power and communication, plus LED, Detector, and Valve Manifold PCBs for each experiment. To facilitate ease of reuse on future missions, experiment electronics were designed to be compatible with a standard 3U small sat form factor and power bus, or to interface with a Master power/comm PCB for use in a larger satellite as in the case of PowerCell's flight on Eu:CROPIS.

biology↗

Larger-Stroke Piezoelectrically Actuated Microvalve

A proposed normally-closed microvalve would contain a piezoelectric bending actuator instead of a piezoelectric linear actuator like that of the microvalve described in the preceding article. Whereas the stroke of the linear actuator of the preceding article would be limited to approximately equal to 6 micrometers, the stroke of the proposed bending actuator would lie in the approximate range of 10 to 15 micrometers-large enough to enable the microvalve to handle a variety of liquids containing suspended particles having sizes up to 10 m. Such particulate-laden liquids occur in a variety of microfluidic systems, one example being a system that sorts cells or large biomolecules for analysis. In comparison with the linear actuator of the preceding article, the bending actuator would be smaller and less massive. The combination of increased stroke, smaller mass, and smaller volume would be obtained at the cost of decreased actuation force: The proposed actuator would generate a force in the approximate range of 1 to 4 N, the exact amount depending on operating conditions and details of design. This level of actuation force would be too low to enable the valve to handle a fluid at the high pressure level mentioned in the preceding article. The proposal encompasses two alternative designs one featuring a miniature piezoelectric bimorph actuator and one featuring a thick-film unimorph piezoelectric actuator (see figure). In either version, the valve would consume a power of only 0.01 W when actuated at a frequency of 100 Hz. Also, in either version, it would be necessary to attach a soft elastomeric sealing ring to the valve seat so that any particles that settle on the seat would be pushed deep into the elastomeric material to prevent or reduce leakage. The overall dimensions of the bimorph version would be 7 by 7 by 1 mm. The actuator in this version would generate a force of 1 N and a stroke of 10 m at an applied potential of 150 V. The actuation force would be sufficient to enable the valve to handle a fluid pressurized up to about 50 psi (approximately equal to 0.35 MPa). The overall dimensions of the unimorph version would be 2 by 2 by 0.5 mm. In this version, an electric field across the piezoelectric film on a diaphragm would cause the film to pull on, and thereby bend, the diaphragm. At an applied potential of 20 V, the actuator in this version would generate a stroke of 10 micrometers and a force of 0.01 N. This force level would be too low to enable handling of fluids at pressures comparable to those of the bimorph version. This version would be useful primarily in microfluidic and nanofluidic applications that involve extremely low differential pressures and in which there are requirements for extreme miniaturization of valves. Examples of such applications include liquid chromatography and sequencing of deoxyribonucleic acid.

Yang, Eui-Hyeok↗

Sample Processor for Life on Icy Worlds (SPLIce): Design and Test Results

We report the design, development, and testing of the Sample Processor for Life on Icy Worlds (SPLIce) system, a microfluidic sample processor to enable autonomous detection of signatures of life and measurements of habitability parameters in Ocean Worlds. This monolithic fluid processing-and-handling system (Figure 1; mass 0.5 kg) retrieves a 50-L-volume sample and prepares it to supply a suite of detection instruments, each with unique preparation needs. SPLIce has potential applications in orbiter missions that sample ocean plumes, such as found in Saturns icy moon Enceladus, or landed missions on the surface of icy satellites, such as Jupiters moon Europa. Answering the question Are we alone in the universe? is captivating and exceptionally challenging. Even general criteria that define life very broadly include a significant role for water [1,2]. Searches for extinct or extant life therefore prioritize locations of abundant water whether in ancient (Mars), or present (Europa and Enceladus) times. Only two previous planetary missions had onboard fluid processing: the Viking Biology Experiments [3] and Phoenixs Wet Chemistry Laboratory (WCL) [4]. SPLIce differs crucially from those systems, including its capability to process and distribute L-volume samples and the integration autonomous control of a wide range of fluidic functions, including: 1) retrieval of fluid samples from an evacuated sample chamber; 2) onboard multi-year storage of dehydrated reagents; 3) integrated pressure, pH, and conductivity measurement; 4) filtration and retention of insoluble particles for microscopy; 5) dilution or vacuum-driven concentration of samples to accommodate instrument working ranges; 6) removal of gas bubbles from sample aliquots; 7) unidirectional flow (check valves); 8) active flow-path selection (solenoid-actuated valves); 9) metered pumping in 100 nL volume increments. The SPLIce manifold, made of three thermally fused layers of precision-machined cyclo-olefin polymer, supports all fluidic components (Figure 1) and integrated microchannels (125 x 250 m). Fluid is pumped by a stepper-motor-driven pump (Lee Co.). The functionality of the integrated MEMS pressure sensor (Honeywell) and passive check valves (Figure 2) were tested in conjunction with our newly designed integral bubble traps (Figure 3) and hydrophobic membrane-based concentrator (Figure 4). The concentrator (initially tested as a standalone component) demonstrated 5-fold vacuum-evaporative concentration. Polyethylene fused bead beds (PEFBBs; 50 porosity) store drylyophilized buffers, calibrants, and fluorescent dyes, and also promote mixing of sample with calibrant, dye, or H2O. Software-controlled automated tests demonstrated successful 1) fluid delivery to each component 2) valve and pump synchronization 3) sample aliquot delivery to instrument interface ports, and 4) rehydration of vacuum-dried fluorescent dye. In Figure 5, fluorescein on PEFBBs was rehydrated for 15 min using a pump-delivered water aliquot; it is displaced as H2O enters the bottom of the channel and pushes the dye into a check valve. Ultimately, SPLIce will fluorescently label amino acids in the sample for microchip-based electrophoretic (MCE) chiral separation and detection to seek and quantify key organic bio-signatures [5]; it will also deliver sample to a microfluidic version of WCL (mWCL) to measure soluble ions and redox-active species.

Life detection↗

Design and Operation of the Planetary In-Situ Capillary Electrophoresis System (PISCES)

The PISCES instrument is a portable, miniature, modular instrument designed to analyze organic molecular signatures of life. PISCES uses microcapillary electrophoresis (μCE) with laser-induced fluorescence detection (LIFD) to analyze fluorescently-labeled analytes prepared on a multi-layer microfluidic chip. As a modular instrument composed of five independently functioning units, each module can be easily detached from the system and used for subsystem testing in different environments, e.g. low temperature. The pneumatic module contains mechanical and electrical components necessary to control pneumatically-actuated valves for on-chip sample processing. A prototype LabVIEW program and two custom printed circuit boards (PCBs) operate the pneumatics module using an Arduino microcontroller, and a tentative design for the module’s housing has been developed. The high-voltage module contains circuitry required to apply varying electrical potentials to the electrophoretic channel of the microdevice. Work is currently being done to design the circuit and PCB for this module in collaboration with our SBIR partners at Los Gatos Research. The optical electronics module contains the spectrometer, laser, and laser power supply. The mounting components for the electronics and housing for the module have been designed, assembled, and tested. The optical module contains optical components to focus the laser to a 20μm spot in the center of the electrophoretic channel.The housing for this module has been designed and assembled with the aligned optical components inside.

Willis, Peter A.↗

A Micro Fluorescent Activated Cell Sorter for Astrobiology Applications

A micro-scale Fluorescent Activated Cell Sorter (microFACS) for astrobiology applications is under development. This device is designed to have a footprint of 7 cm x 7 cm x 4 cm and allow live-dead counts and sorting of cells that have fluorescent characteristics from staining. The FACS system takes advantage of microfluidics to create a cell sorter that can fit in the palm of the hand. A micron-scale channel allows cells to pass by a blue diode which causes emission of marker-expressed cells which are detected by a filtered photodetector. A small microcontroller then counts cells and operates high speed valves to select which chamber the cell is collected in (a collection chamber or a waste chamber). Cells with the expressed characteristic will be collected in the collection chamber. This system has been built and is currently being tested. We are also designing a system with integrated MEMS-based pumps and valves for a small and compact unit to fly on small satellite-based biology experiments.

Platt, Donald W.↗

Development of a fully integrated analysis system for ions based on ion-selective optodes and centrifugal microfluidics

A fully integrated, miniaturized analysis system for ions based on a centrifugal microfluidics platform and ion-selective optode membranes is described. The microfluidic architecture is composed of channels, five solution reservoirs, a measuring chamber, and a waste reservoir manufactured onto a disk-shaped substrate of poly(methyl methacrylate). Ion-selective optode membranes, composed of plasticized poly(vinyl chloride) impregnated with an ionophore, a proton chromoionophore, and a lipophilic anionic additive, were cast, with a spin-on device, onto a support layer and then immobilized on the disk. Fluid propulsion is achieved by the centrifugal force that results from spinning the disk, while a system of valves is built onto the disk to control flow. These valves operate based on fluid properties and fluid/substrate interactions and are controlled by the angular frequency of rotation. With this system, we have been able to deliver calibrant solutions, washing buffers, or "test" solutions to the measuring chamber where the optode membrane is located. An analysis system based on a potassium-selective optode has been characterized. Results indicate that optodes immobilized on the platform demonstrate theoretical responses in an absorbance mode of measurement. Samples of unknown concentration can be quantified to within 3% error by fitting the response function for a given optode membrane using an acid (for measuring the signal for a fully protonated chromoionophore), a base (for fully deprotonated chromoionophore), and two standard solutions. Further, the ability to measure ion concentrations by employing one standard solution in conjunction with acid and base and with two standards alone were studied to delineate whether the current architecture could be simplified. Finally, the efficacy of incorporating washing steps into the calibration protocol was investigated.

NASA Discipline Life Sciences Technologies↗

Cosmo Cassette: A Microfluidic Microgravity Microbial System For Synthetic Biology Unit Tests and Satellite Missions

Although methods in the design-build-test life cycle of the synthetic biology field have grown rapidly, the expansion has been non-uniform. The design and build stages in development have seen innovations in the form of biological CAD and more efficient means for building DNA, RNA, and other biological constructs. The testing phase of the cycle remains in need of innovation. Presented will be both a theoretical abstraction of biological measurement and a practical demonstration of a microfluidics-based platform for characterizing synthetic biological phenomena. Such a platform demonstrates a design of additive manufacturing (3D printing) for construction of a microbial fuel cell (MFC) to be used in experiments carried out in space. First, the biocompatibility of the polypropylene chassis will be demonstrated. The novel MFCs will be cheaper, and faster to make and iterate through designs. The novel design will contain a manifold switchingdistribution system and an integrated in-chip set of reagent reservoirs fabricated via 3D printing. The automated nature of the 3D printing yields itself to higher resolution switching valves and leads to smaller sized payloads, lower cost, reduced power and a standardized platform for synthetic biology unit tests on Earth and in space. It will be demonstrated that the application of unit testing in synthetic biology will lead to the automatic construction and validation of desired constructs. Unit testing methodologies offer benefits of preemptive problem identification, change of facility, simplicity of integration, ease of documentation, and separation of interface from implementation, and automated design.

Bioelectrochemical System↗

NASA Tech Briefs, August 2013

Topics covered include: Radial Internal Material Handling System (RIMS) for Circular Habitat Volumes; Conical Seat Shut-Off Valve; Impact-Actuated Digging Tool for Lunar Excavation; Flexible Mechanical Conveyors for Regolith Extraction and Transport; Remote Memory Access Protocol Target Node Intellectual Property; Soft Decision Analyzer; Distributed Prognostics and Health Management with a Wireless Network Architecture; Minimal Power Latch for Single-Slope ADCs; Bismuth Passivation Technique for High-Resolution X-Ray Detectors; High-Strength, Super-elastic Compounds; Cu-Cr-Nb-Zr Alloy for Rocket Engines and Other High-Heat- Flux Applications; Microgravity Storage Vessels and Conveying-Line Feeders for Cohesive Regolith; CRUQS: A Miniature Fine Sun Sensor for Nanosatellites; On-Chip Microfluidic Components for In Situ Analysis, Separation, and Detection of Amino Acids; Spectroscopic Determination of Trace Contaminants in High-Purity Oxygen; Method of Separating Oxygen From Spacecraft Cabin Air to Enable Extravehicular Activities; Atomic Force Microscope Mediated Chromatography; Sample Analysis at Mars Instrument Simulator; Access Control of Web- and Java-Based Applications; Tool for Automated Retrieval of Generic Event Tracks (TARGET); Bilayer Protograph Codes for Half-Duplex Relay Channels; Influence of Computational Drop Representation in LES of a Droplet-Laden Mixing Layer.

Source record↗

Cascading Tesla Oscillating Flow Diode for Stirling Engine Gas Bearings

Replacing the mechanical check-valve in a Stirling engine with a micromachined, non-moving-part flow diode eliminates moving parts and reduces the risk of microparticle clogging. At very small scales, helium gas has sufficient mass momentum that it can act as a flow controller in a similar way as a transistor can redirect electrical signals with a smaller bias signal. The innovation here forces helium gas to flow in predominantly one direction by offering a clear, straight-path microchannel in one direction of flow, but then through a sophisticated geometry, the reversed flow is forced through a tortuous path. This redirection is achieved by using microfluid channel flow to force the much larger main flow into this tortuous path. While microdiodes have been developed in the past, this innovation cascades Tesla diodes to create a much higher pressure in the gas bearing supply plenum. In addition, the special shape of the leaves captures loose particles that would otherwise clog the microchannel of the gas bearing pads.

Dyson, Rodger↗