At least 37 records · Page 2

Stacked Low-Inertia Converter or Solid-State Transformer: Modeling and Model Predictive Priority-Shifting Control for Voltage Balance

This paper presents control challenges of stacked low-inertia converter (SLIC) or cascaded reduced dc-link solid-state transformer (SST) and proposes a novel model predictive priority-shifting (MPPS) control with implicit modulator and a discrete-time large-signal model for voltage balancing and dc-link regulation. Low-inertia converters, featuring small electrolytic capacitor-less dc links, dramatically reduce cost, size, and weight compared to conventional solutions. However, without a large dc-link buffer, the input and output are tightly coupled, leading to significant control challenges. The control becomes even more challenging with these converters stacked input-series output-parallel (ISOP) for medium-voltage (MV) grid, which causes coupling between the modules besides the coupling within each module. This paper analyzes the multi-objective, multi-degree of freedom control problem, using the modular soft-switching solid-state transformer (M-S4T) as an example of the SLIC. First, distribution of control efforts under controller saturation is critical because multiple control objectives can be conflicting, especially when the module voltages are unbalanced and are being restored. The MPPS can shift the priorities to address this issue. Second, due to the low inertia and high dc-link ripple, classic space vector pulse-width modulation (SVPWM), average model with small-ripple assumption, and control design based on small-signal model cannot accurately modulate, model, and control the nonlinear reduced dc link. Therefore, a discrete-time large-signal model of the M-S4T is established to derive the predictive control in the MPPS. The MPPS and the PI control are compared in MV simulations to show the issue of applying the PI to the SLIC and the effectiveness of the MPPS for voltage balancing and dc-link regulation in a deadbeat manner. Finally, the proposed control is tested on a 5 kV ISOP SiC SST prototype to verify priority shifting to address controller saturation issue and fast and robust voltage balancing.

14 SOLAR ENERGY↗

Predictive Direct DC-Link Control for 7.2 kV Three-Port Low-Inertia Solid-State Transformer With Active Power Decoupling

Promising for applications including renewable energy and electric vehicle fast charging, a medium-voltage (MV) solid-state transformer (SST) typically has multiple modules series stacked, which requires the modules to be single phase. One critical issue of the single-phase SST is the double-line-frequency power ripple. Traditionally, large passives are used to buffer the ripple, resulting in significantly increased volume and cost. This article for the first time proposes active power decoupling (APD) for the SST and a predictive direct DC-link control method, using a current-source single-stage SST as an example. An electrolytic capacitor-less buffer port is used to absorb the ripple, which tolerates up to a 30% voltage ripple for small capacitance. The APD SST control is challenging. First, the current-source SST realizes isolation, DC link, and multiport in a single stage. Second, different from conventional SSTs or APD converters, the low-inertia DC link in this SST has a 40% switching ripple, which is difficult to stabilize. To address the control challenge, a direct DC-link control architecture and a predictive control method are proposed. Simulation and experimental results verify the proposed control method on an MV SiC modular soft-switching solid-state transformer (M-S4T) prototype. Here, the proposed APD reduces the SST volume by 53.8%. Importantly, the proposed concept is not limited to the M-S4T but is generic to other SSTs or APD converters.

14 SOLAR ENERGY↗

Insulation Coordination Design for Grid-Connected Solid-State Transformers

The deployment of solid-state transformers (SSTs) in medium-voltage (MV) distribution systems is facing various challenges, especially the challenge of insulation coordination design against grid-originated lightning impulses. In this article, two challenges in existing insulation coordination designs for grid-connected SSTs are identified. One challenge is the mismatch between metal-oxide varistor (MOV) protective levels and SST insulation strength, the other challenge is the incompatibility of standard impulse test on SST protective structures. To address the MOV selection challenge, a novel lightning protection scheme is designed to protect a single-stage SST where the semiconductor modules are directly exposed to external lightning impulses. Here, the in-lab lightning impulse tests are performed to verify the overvoltage attenuation performance of the prototyped lightning protection scheme. To address the impulse test challenge, the surge withstand capability of the protected SST is comprehensively evaluated with a complete set of insulation coordination design procedures beyond the basic insulation level (BIL) test. After these two challenges are addressed, a discussion is presented on substituting conventional transformers with the protected SSTs into insulation-coordinated distribution systems to facilitate the field deployment of SSTs.

solid-state transformer (SST)↗

Multiport Control with Partial Power Processing in Solid-State Transformer for PV, Storage, and Fast-Charging Electric Vehicle Integration

This article proposes a multiport control method to enable partial power processing (PPP) in a medium-voltage (MV) multiport solid-state transformer (SST). MV multiport SSTs are promising in integrating low-voltage DC sources or loads such as solar photovoltaic, energy storage, and electric vehicles into smart grids without bulky line-frequency transformers. Compared to voltage-source SST, current-source (CS) SST features single-stage isolated bidirectional AC/AC, AC/DC, or DC/DC conversion using an inductive DC link. For a multiport CS SST, it is revealed in this article that the PPP capability can be enabled through the proposed control without extra hardware, different from the case of voltage-source converters where special hardware architecture is required for the PPP. With the PPP, most power exchange between LV ports is processed by only a fraction of the entire conversion stage, leading to reduced DC-link current, volume, loss, and improved efficiency. The proposed multiport PPP control scheme is analyzed to verify the advantages across a wide voltage and power range against conventional full power processing (FPP) multiport control, using the soft-switching solid-state transformer (S4T) with reduced conduction loss as an example. Comparative experimental results based on a SiC three-port S4T prototype verify the effectiveness of the proposed PPP scheme against the FPP scheme under both steady state and dynamic conditions. Here, the DC-link current reduction is measured to be more than 36%. Significantly, the proposed multiport PPP control scheme is generic and applicable to any hard-switching or soft-switching CS SSTs without extra hardware.

14 SOLAR ENERGY↗

An analysis of parameters affecting ampacity in aircraft bipolar MVDC power cables via coupled electrical, thermal, and computational fluid dynamic modelling

Abstract The next generation of aircraft, including more electric aircraft and all‐electric aircraft (AEA), requires electric power systems with high power density and low system mass specifications. Increasing the voltage of the system to the range of a few kV, medium voltage (MV), is a reasonable approach to achieving high‐power‐density and low‐system‐mass EPSs for aircraft applications. Higher voltages, however, pose many challenges for aviation MV power cables such as arcs and arc tracking, partial discharges (PDs), and thermal management. In this regard, thermal management is more challenging since heat transfer by convection is greatly reduced at wide‐body aircraft's cruising altitudes due to the reduced air pressure. In this paper, a finite element method (FEM) model is developed in COMSOL Multiphysics for an aircraft bipolar MVDC (±5 kV) power cable. Using the model, the maximum permissible cable current at a low pressure of 18.8 kPa (at an altitude of 12.2 km from sea level, the usual cruising altitude for wide‐body aircraft) is calculated. Also, an analytical model is developed based on analytical and proven empirical correlations governing conductive, radiative, and convective heat transfers at the steady state to estimate the ampacity of the bipolar cable system at reduced pressure. It was shown that the proposed analytical model can be used for atmospheric pressure and systems with a larger number of poles, expanding its range of applications. The results of the FEM and analytical models correlate at wide ranges of parameters such as ambient temperature, duct size, distance between the positive and negative pole cables, and the overall diameter of the cables. The influence of horizontal and vertical arrangement of poles is included in the analytical model. The results of this study can be used to design bipolar MVDC power cable systems for the envisaged wide‐body AEA.

Azizi, Arian↗

Medium Voltage Solid State Transformer for Extreme Fast Charging Applications

A modular and scalable solid state transformer (SST) with direct medium voltage (MV) AC connectivity is proposed to enable DC extreme fast charging (XFC) of electric vehicles. Single-phase-modules (SPMs), each consisting of an active-front-end (AFE) stage and an isolated DC-DC stage, are connected in input-series-output-parallel (ISOP) configuration. The modular hardware is co-designed with decentralized control of the DC-DC stages where voltage and power balancing are achieved by each SPM using only its local sensor feedback; a centralized controller (CC) regulates the low voltage (LV) DC bus through the AFE stages without any sensor feedback form the SPMs. The controller architecture contrasts sharply with the prior art for MV AC to LV DC SSTs where high-speed bidirectional communication among SPMs and a CC are required for module-level voltage and power balancing, which severely limits the scalability and practical realization of higher voltage and higher power units. Detailed small-signal analysis and controller design guidelines are developed. Furthermore, a soft start-up strategy is presented. The proposed converter and control structure are validated through simulation and experimental results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Circulating Current Reduction of Back-to-Back MMC with Advanced Grid-Support Functionalities for Medium-Voltage Applications

A Lyapunov energy function based circulating current reduction scheme for a back to back modular multilevel converter based system for a microgrid application has been proposed in this digest. In order to ensure no circulating or zero sequence currents within the modules, the dynamics from one leg of the converter to the other are evaluated. A Lyapunov energy function is then developed and utilizing the circulating current dynamics of the converter the overall control law is implemented. In this digest a decentralized hierarchical control architecture has been implemented for the main current control; where the outer loop or the central controller implements the higher level grid interconnection functions as per IEEE 1547-2018 standards and the inner loop based on synchronous reference frame implements the current control architecture. The inner loops' outputs are the commanded converter voltages either on either side which are augmented by the Lyapunov energy function based circulating current suppression architecture. To evaluate the efficacy of the overall system, the overall system is modeled around a 300kVA back to back SiC multilevel modular converter used as a direct-connected medium voltage (MV) grid intertie based on MATLAB/Simulink domain. Several important case studies are presented in this paper to prove the effectiveness of the proposed architecture. case study results are presented.

circulating current↗

Segmented Energy Routing for a Modular AC/DC Hybrid System

This article presents a modular ac/dc system with both distributed and centralized power ports for energy router (ER) applications. In each module of the described system, photovoltaic (PV) power generation units, battery-type energy storage (ES) units, and critical loads are connected to the cascaded H-bridge (CHB)-organized medium-voltage (MV) dc links, with fully distributed low-voltage (LV) dc power ports. Copies of modules share the centralized load bus and interact with an MV ac grid in parallel. Hybrid power port (HPO) assigns flexibility to the system but makes energy routings a necessity for stable operation. In this article, a segmented energy management strategy for the HPO-ER is proposed. In terms of the grid-side power transferring, the system ratings are intentionally designed to match significant power imbalance. Focally, a segmented energy management strategy is proposed to realize fully autonomous energy routing involving MV ac grid, distributed PV generations, distributed battery storages, and LV load. The system is proven to be stable using the derived impedance-based model considering the interaction between power blocks. The feasibility of the topology and control strategy is also verified through software simulation, laboratorial hardware prototype experiment, and hardware-in-the-loop (HIL) emulation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Reliability Analysis of Large-Area, Low Pressure-Assisted Silver Sintering for Medium-Voltage Power Modules

Multi-layer insulating ceramic substrates can enable medium-voltage (MV) power modules with reduced peak electric field. This benefit is particularly important for MV silicon carbide (SiC) MOSFETs due to their higher operating voltages. Large-area, low-pressure assisted silver sintering is a potential solution for bonding substrates to create a multi-layer structure. The voiding content and defect density of the bond used to create the multi-layer substrate stack-up is critical to the reliability of the power module and the thermal performance, as this bond is in the primary path for heat dissipation in the power module structure. Here, samples of two-layer direct bonded aluminum (DBA) stacks have been fabricated and subjected to thermal cycling to analyze their reliability. Passive thermal cycling from -40 degrees C to 200 degrees C was performed. Cross-sections were cut at pre-determined intervals and imaged with Scanning Electron Microscopy (SEM). After 1000 thermal cycles, adhesive failures are observed between the sintered silver and the DBA surface. Cross-sections were cut and imaged via optical microscope and SEM. Thermal analyzer measurements are recorded on a 10-kV SiC power module utilizing the sintered DBA substrate stacks.

30 DIRECT ENERGY CONVERSION↗

Electromagnetic Transient (EMT) Simulation Algorithm for Evaluation of Photovoltaic (PV) Generation Systems

Use of inverter-based resources facilitating renewable energy resources such as photovoltaic (PV) generation is increasing rapidly with decreasing costs and reduced emissions associated. To accommodate such rapid growth of inverter-based resources like PV systems, electromagnetic transient (EMT) simulation models of both PV systems and grids are required to analyze the interaction of PVs in the grid (like the post-event analysis). In addition, the EMT simulation would help with the planning of future power grid with a large number of PVs as well as other inverter-based distributed generation systems. In this paper, the EMT simulation models of PV systems and grids are developed based on the differential algebraic equations (DAEs) representing their EMT dynamics. Furthermore, advanced simulation algorithms including numerical stiffness-based hybrid discretization, DAE clustering and aggregation, multi-order integration, and matrix splitting approaches are applied to accelerate the EMT simulation. The proposed algorithm was applied to 125 PV inverters within 52-bus medium-voltage (MV) distribution grid.

Choi, Jongchan↗

Robust Predictive Control for Modular Solid-State Transformer With Reduced DC Link and Parameter Mismatch

This paper presents the analysis and implementation of a predictive control method for dc-link regulation and voltage balance in a cascaded modular reduced dc-link solid-state transformer (SST). Passive components like bulky dc links limit the power density of power converters, especially medium-voltage (MV) SST. Reduced dc-link or low-inertia converters can dramatically reduce the size, cost, and weight by tolerating larger dc-link ripples and improve the reliability with electrolytic capacitor-less dc link. However, a small dc link leads to tight coupling between the input and the output stages, which is a challenge for control design. In stacked low-inertia converters (SLIC), the low-inertia converter modules are stacked for MV applications, resulting in coupling between the modules and making the control more challenging. A new model predictive control method which can achieve deadbeat regulation on the dc link without weighting factors has been proposed to address this novel problem. This paper focuses on analyzing the condition of the low-inertia dc link up to 80% ripple, the robustness of the control under parameter mismatches, high-order terms, and important implementation issues such as model-based sampling and computation delay compensation. Significantly, the high-order terms are introduced because of the large dc-link ripple. These high-order terms are unique to the SLIC and negligible in conventional high-inertia converters. A discrete-time large-signal model is built to capture the dc-link’s nonlinear dynamics, and the eigenvalues of a small-signal Jacobian matrix are analyzed with Floquet theory to evaluate stability, using the modular soft-switching solid-state transformer (M-S4T) as an example of the SLIC. Simulation and experimental results of an MVDC M-S4T verify the analysis and the predictive control method. Finally, the general application of the predictive control to low-inertia converters is compared against a conventional PI controller using a reduced dc-link active-front-end (AFE) rectifier as an example.

14 SOLAR ENERGY↗

Thermal Modeling and Limitations for Power Electronics Embedded in Medium-Voltage Cables

As next-generation energy technologies gain traction and power demand increases, the existing electrical infrastructure faces significant stress, prompting innovative solutions to enhance the grid's capacity and lifespan. This work explores the possibility of embedding medium-voltage (MV) power electronics directly inline with the cable, and the resulting thermal challenges. Since the majority of power distribution cables installed in the U.S. are passively cooled, the work focuses primarily on passive cooling, with an emphasis on the limitations of axial heat spreading within the cable. To date, literature on axial spreading of high incident heat loads on cables and cable environments is limited, typically reporting cases with <10 W of incident heat load. This work will explore the considerations, limits, and tradeoffs of cable-embedded heat loads significantly larger than the cable losses. Both external and internal effects are modeled analytically in nondimensional terms via a Biot number analysis, allowing fundamental limits and tradeoffs to be derived. The work culminates in the design and experimental validation of a cable-embedded thermal system capable of passively dissipating 300 W of heat from a coaxial SiC mosfet switch module over a length of 20 cm, thus validating the possibility of MV cable-embedded power electronics from a thermal standpoint.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Design, Control, and Protection of a 13.2 kV, 1 MVA Solid State Transformer for Electric Vehicle Extreme Fast Charging Station

In this article, a medium-voltage (MV) ac-dc solid state transformer (SST) for electric vehicle (EV) extreme fast charging (XFC) station is proposed. The SST adopts a cascaded H-bridge (CHB)-based structure where the active front end (AFE) power stages are connected in input-series followed by dual active bridge (DAB) converters connected in an output-parallel configuration providing galvanic isolation through a high-frequency transformer (HFT). The SST is rated for 1 MVA and connects directly to a three-phase 13.2 kV MV ac grid through ac switchgear and outputs 750-V dc. At the dc bus, several dc/dc converters are connected, each of which can charge an EV based on its battery capacity. A novel decentralized control architecture of the SST is adopted in this work which simplifies the MV dc link voltage and module-level power balancing. In addition, the local and central protection designs of the SST are presented which identify and respond to the internal fault of the system. Finally, the experimental validations of the SST hardware prototype are presented up to the rated voltage. Furthermore, this article details the design and implementation of the MV SST addressing the challenges of an isolated MV class power converter for connecting directly to the MV ac grid with unique controller architecture, distributed protection framework, and SST constructional features.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Flux Balancing Strategy for 10-kV SiC-Based Dual-Active-Bridge Converter

The transformer flux unbalance in dual-active-bridge (DAB) converters is a critical issue due to the electrical parameter and modulation mismatch, and load or control transients. Compared to low voltage DAB converters, the unbalance problem in medium voltage DAB converters may cause more severe problem, and become more difficult to deal with, because of the high operating voltage and insulation requirement. In this paper, a flux balancing strategy for a medium voltage (MV) DAB converter is proposed, including the transformer design with ferrite gap, current harmonic-based unbalance detection, as well as the flux balancing control scheme. With the proposed ferrite gap, nonlinear magnetizing current and its modeling are induced. Then, by analyzing the current harmonics, the flux unbalance level can be detected, and hence controlled. Test results have verified the proposed method in a MV DAB converter.

Gao, Zihan↗

SiC-Based Wireless Power Transformation for Data Centers & Medium Voltage Applications

Data centers have grown in physical size and their electrical power consumption has grown to levels of several 100kW and approaching 1 GW in large installations. The low voltage electrical distribution inside of Data Centers consists of several conversion stages and a lot of wiring to bring the power from medium voltage (MV) levels outside of the building to the low voltage levels that the servers and racks require. Energy losses during distribution and conversion and high incident arc flash energy levels at the point of use are significant. The electrical distribution system is complex and costly.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Survey and Benchmark of Benefits of High Voltage SiC Applications in Medium Voltage Power Distribution Grids

The main objective of this survey and benchmark study is to identify and document potential high-impact applications in today's and future medium voltage (MV) distribution grids that will significantly benefit from high voltage (HV) (i.e. > 3.3 kV) SiC-based power electronics equipment. In particular, it is desirable to identify applications that can utilize the high switching speed and high control bandwidth enabled by SiC-based equipment. Specifically, the benefits of using SiC are quantified through the benchmark analysis and design using simulation for the selected high-impact applications. In addition, to provide grid support services, it is necessary to consider grid requirements in the grid-connected converter's design. Therefore, the impact of grid requirements on the HV SiC-based grid-connected converter is evaluated.

24 POWER TRANSMISSION AND DISTRIBUTION↗

SiC Based Modular Transformer-less MW-Scale Power Conditioning System and Control for Flexible CHP System

This project aims at developing a SiC-based, modular, transformer-less (60-Hz-transformers-free), MW-scale, four-wire DC/AC power conditioning system (PCS) converter, and a corresponding control system for flexible-CHP (F-CHP) systems. With the help of an F-CHP controller and power electronics converters, different CHP sources, renewable sources, and batteries can be assembled to the DC grid, which is then connected to the medium voltage (MV) AC grid through the PCS converter. To meet grid support and performance requirements, the F-CHP controller design and PCS converter design follow IEEE 1547 and IEEE 2030.7 standards. Five main tasks, including PCS converter design, F-CHP controller development, PCS converter prototype building and testing, F-CHP controller testing, and PCS paralleling, have been carried out. In this project, the F-CHP controller testing has been completed in simulation, HIL and HTB, and the PCS converter prototypes have been successfully built and tested.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Intelligent, grid-friendly, modular extreme fast charging system with solid-state DC protection

The development of electric vehicle (EV) charging infrastructure is crucial for the widespread adoption of electric transportation. However, implementing such infrastructure is a complex task that requires consideration of factors such as space limitations, adherence to industry standards, grid capacity, and other technical and policy issues. This project seeks to create a framework for the efficient design of compact medium voltage (MV) extreme fast charging (XFC) stations for EVs. The station design involves the use of a solid-state transformer (SST) that connects to the MV distribution network, delivering power to a shared DC bus. This innovative approach eliminates the need for a step-down transformer to provide low-voltage service by connecting directly to the MV distribution network. Eliminating the low-frequency transformer not only reduces the system footprint and losses but also eliminates inrush currents during grid black-start. Additionally, placing power electronics directly on the distribution system allows for high-bandwidth filtering and power factor correction. The inclusion of a shared DC bus enables multiple charging dispensers and DC storage/generation units to connect, forming a DC microgrid. This setup facilitates power sharing with minimal conversion stages. The project showcases a DC distribution network protected by intelligent solid-state (SS) DC circuit breakers (DCCB) capable of isolating the smallest section of the faulted circuit much faster than existing mechanical solutions.

24 POWER TRANSMISSION AND DISTRIBUTION↗