Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “measurement errors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Modeling noise in global Mølmer-Sørensen interactions applied to quantum approximate optimization

Many-qubit Mølmer-Sørensen (MS) interactions applied to trapped ions offer unique capabilities for quantum information processing, with applications including quantum simulation and the quantum approximate optimization algorithm (QAOA). Here, we develop a physical model to describe many-qubit MS interactions under four sources of experimental noise: vibrational mode frequency fluctuations, laser power fluctuations, thermal initial vibrational states, and state preparation and measurement errors. The model parametrizes these errors from simple experimental measurements, without free parameters. Herein, we validate the model in comparison with experiments that implement sequences of MS interactions on two 171 Yb + ions. The model shows reasonable agreement after several MS interactions as quantified by the reduced chi-squared statistic $χ^{2}_{red}$≈2. As an application we examine MaxCut QAOA experiments on three and six ions. The experimental performance is quantified by approximation ratios that are 91% and 83% of the optimal theoretical values. Our model predicts $0.93^{+0.03}_{-0.02}$ and $0.95^{+0.04}_{-0.03}$, respectively, with disagreement in the latter value attributable to secondary noise sources beyond those considered in our analysis. With realistic experimental improvements to reduce measurement error and radial trap frequency variations, the model achieves approximation ratios that are 99% of the optimal. Incorporating these improvements into future experiments is expected to reveal new aspects of noise for future modeling and experimental improvements.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Statistics and sensitivity of axion wind detection with the homogeneous precession domain of superfluid helium-3

The homogeneous precession domain (HPD) of superfluid He 3 has recently been identified as a detection medium which might provide sensitivity to the axion-nucleon coupling g a N N competitive with, or surpassing, existing experimental proposals. In this work, we make a detailed study of the statistical and dynamical properties of the HPD system in order to make realistic projections for a full-fledged experimental program. We include the effects of clock error and measurement error in a concrete readout scheme using superconducting qubits and quantum metrology. This work also provides a more general framework to describe the statistics associated with the axion gradient coupling through the treatment of a transient resonance with a nonstationary background in a time-series analysis. Incorporating an optimal data-taking and analysis strategy, we project a sensitivity approaching g a N N ∼ 10 − 12 GeV − 1 across a decade in axion mass. Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Error field measurements and correction on MUSE permanent magnet stellarator

The magnetic field topology and error fields are measured in the MUSE permanent magnet stellarator with an electron beam and fluorescent rod. The effective magnetization of the magnets is determined by measuring rational flux surface locations. Electron magnetic drift effects must be considered self-consistently due to the small magnetic shear on MUSE. Error fields are characterized by flux surface shape deviation and magnetic island chain width and phase. Error fields are then corrected by adjusting the permanent magnet (PM) holders as rigid bodies. Resonant error fields are on the order of or smaller than 3 x 10 -6 of the toroidal field after correction and surface shape matches well with the design. Resonant components of the quasi-symmetry deviation are estimated, using a novel magnetic drift measurement, to be in the 10 −4 range. The PM approach is validated as a low-cost and precise way to build optimized stellarators.

electron beam mapping↗

A Non-Intrusive Optical (NIO) Method to Measure Optical Errors of in-situ Heliostats in Utility-Scale Power Tower Plants: Detecting Uncertainties in Heliostat Geometry

Heliostat optical errors can account for significant losses in efficiency of power tower concentrating solar power (CSP) plants. Accurately measuring heliostat optical errors can help to improve plant performance. A Non-Intrusive Optical (NIO) method has been developed to efficiently measure heliostat optical errors from UAS collected images of the mirror surface reflection [1]–[3]. In some cases, plant data of heliostat geometry can be incomplete or contain inaccuracies, in which case field collected data can be used to detect and correct uncertainties, which is valuable information for plant operators.

Mitchell, Rebecca↗

Measuring a Low Horizontal Hydraulic Gradient in a High Transmissivity Aquifer

Abstract High transmissivity aquifers typically have low hydraulic gradients (i.e., a flat water table). Measuring low gradients using water levels can be problematic because measurement error may be greater than the true difference in water levels (i.e., a low signal‐to‐noise ratio). In this study, the feasibility of measuring a hydraulic gradient in the range of 10 −6 to 10 −5 m/m was demonstrated. The study was performed at a site where the depth to water from land surface ranged from 40.1 to 94.2 m and the aquifer transmissivity was estimated at 41,300 m 2 /d (hydraulic conductivity of 18,800 m/d). The goals of the study were to reduce measurement error as much as practicable and assess the importance of factors affecting water level measurement accuracy. Well verticality was the largest source of error (0.000 to 0.168 m; median of 0.014 m), and geodetic survey of casing elevations was the next most important source of error (0.002 to 0.013 m; median of 0.005 m). Variability due to barometric pressure fluctuations was not an important factor at the site. Hydraulic heads were measured to an accuracy of ±0.0065 m, and the average hydraulic gradient was estimated to be 8.0 × 10 −6 (±0.9 × 10 −6 ) m/m. The improvement in accuracy allowed for two reversals in the groundwater flow direction to be identified, after which the gradient averaged 2.5 × 10 −5 (±0.4 × 10 −5 ) m/m. This study showed it is possible to sufficiently control sources of error to measure hydraulic gradients in the 10 −6 to 10 −5 m/m range.

McDonald, John P.↗

Behavior and mechanisms of Doppler wind lidar error in varying stability regimes

Abstract. Wind lidars are widespread and important tools in atmospheric observations. An intrinsic part of lidar measurement error is due to atmospheric variability in the remote-sensing scan volume. This study describes and quantifies the distribution of measurement error due to turbulence in varying atmospheric stability. While the lidar error model is general, we demonstrate the approach using large ensembles of virtual WindCube V2 lidar performing a profiling Doppler-beam-swinging scan in quasi-stationary large-eddy simulations (LESs) of convective and stable boundary layers. Error trends vary with the stability regime, time averaging of results, and observation height. A systematic analysis of the observation error explains dominant mechanisms and supports the findings of the empirical results. Treating the error under a random variable framework allows for informed predictions about the effect of different configurations or conditions on lidar performance. Convective conditions are most prone to large errors (up to 1.5 m s−1 in 1 Hz wind speed in strong convection), driven by the large vertical velocity variances in convective conditions and the high elevation angle of the scanning beams (62∘). Range-gate weighting induces a negative bias into the horizontal wind speeds near the surface shear layer (−0.2 m s−1 in the stable test case). Errors in the horizontal wind speed and direction computed from the wind components are sensitive to the background wind speed but have negligible dependence on the relative orientation of the instrument. Especially during low winds and in the presence of large errors in the horizontal velocity estimates, the reported wind speed is subject to a systematic positive bias (up to 0.4 m s−1 in 1 Hz measurements in strong convection). Vector time-averaged measurements can improve the behavior of the error distributions (reducing the 10 min wind speed error standard deviation to <0.3 m s−1 and the bias to <0.1 m s−1 in strong convection) with a predictable effectiveness related to the number of decorrelated samples in the time window. Hybrid schemes weighting the 10 min scalar- and vector-averaged lidar measurements are shown to be effective at reducing the wind speed biases compared to cup measurements in most of the simulated conditions, with time averages longer than 10 min recommended for best use in some unstable conditions. The approach in decomposing the error mechanisms with the help of the LES flow field could be extended to more complex measurement scenarios and scans.

17 WIND ENERGY↗

Best Practices for Body Temperature Measurement with Infrared Thermography: External Factors Affecting Accuracy

Infrared thermographs (IRTs) are commonly used during disease pandemics to screen individuals with elevated body temperature (EBT). To address the limited research on external factors affecting IRT accuracy, we conducted benchtop measurements and computer simulations with two IRTs, with or without an external temperature reference source (ETRS) for temperature compensation. The combination of an IRT and an ETRS forms a screening thermograph (ST). We investigated the effects of viewing angle (θ, 0–75°), ETRS set temperature (T ETRS , 30–40 °C), ambient temperature (T atm , 18–32 °C), relative humidity (RH, 15–80%), and working distance (d, 0.4–2.8 m). We discovered that STs exhibited higher accuracy compared to IRTs alone. Across the tested ranges of T atm and RH, both IRTs exhibited absolute measurement errors of less than 0.97 °C, while both STs maintained absolute measurement errors of less than 0.12 °C. The optimal T ETRS for EBT detection was 36–37 °C. When θ was below 30°, the two STs underestimated calibration source (CS) temperature (T CS ) of less than 0.05 °C. The computer simulations showed absolute temperature differences of up to 0.28 °C and 0.04 °C between estimated and theoretical temperatures for IRTs and STs, respectively, considering d of 0.2–3.0 m, T atm of 15–35 °C, and RH of 5–95%. The results highlight the importance of precise calibration and environmental control for reliable temperature readings and suggest proper ranges for these factors, aiming to enhance current standard documents and best practice guidelines. These insights enhance our understanding of IRT performance and their sensitivity to various factors, thereby facilitating the development of best practices for accurate EBT measurement.

47 OTHER INSTRUMENTATION↗

LiG Metrology, Correlated Error, and the Integrity of the Global Surface Air-Temperature Record

The published 95% uncertainty of the global surface air-temperature anomaly (GSATA) record through 1980 is impossibly less than the 2σ = ±0.25 °C lower limit of laboratory resolution of 1 °C/division liquid-in-glass (LiG) thermometers. The ~0.7 °C/century Joule-drift of lead- and soft-glass thermometer bulbs renders unreliable the entire historical air-temperature record through the 19th century. A circa 1900 Baudin meteorological spirit thermometer bulb exhibited intense Pb X-ray emission lines (10.55, 12.66, and 14.76 keV). Uncorrected LiG thermometer non-linearity leaves 1σ = ±0.27 °C uncertainty in land-surface air temperatures prior to 1981. The 2σ = ±0.43 °C from LiG resolution and non-linearity obscures most of the 20th century GSATA trend. Systematic sensor-measurement errors are highly pair-wise correlated, possibly across hundreds of km. Non-normal distributions of bucket and engine-intake difference SSTs disconfirm the assumption of random measurement error. Semivariogram analysis of ship SST measurements yields half the error difference mean, ±½Δε 1,2, not the error mean. Transfer-function adjustment following a change of land station air-temperature sensor eliminates measurement independence and forward-propagates the antecedent uncertainty. LiG resolution limits, non-linearity, and sensor field calibrations yield GSATA mean ±2σ RMS uncertainties of, 1900–1945, ±1.7 °C; 1946–1980, ±2.1 °C; 1981–2004, ±2.0 °C; and 2005–2010, ±1.6 °C. Finally, the 20th century (1900–1999) GSATA, 0.74 ± 1.94 °C, does not convey any information about rate or magnitude of temperature change.

54 ENVIRONMENTAL SCIENCES↗

Evaluating Methods for Measuring Grid Frequency in Low-Inertia Power Systems: Preprint

Accurate measurement of grid frequency is a critical component of reliable grid control. Traditionally, methods such as phase locked loops (PLLs) and discrete Fourier transforms (DFTs) have been used in inverters and phasor measurement units (PMUs) to measure frequency. However, as the percentage of inverter-based resources (IBRs) such as solar and wind has increased, these conventional frequency measurement methods are proving unable to guarantee reliable control in some cases. One challenge is measuring frequency during transient events, where there is a disruption in the steady state sinusoidal voltage. During these events, the underlying frequency of the grid may barely change, but measurement methods report a large spike in frequency due to the disrupted waveform. New methods must balance between suppressing spikes in frequency during faults, and providing fast, accurate, measurements in all other grid operation conditions, especially during events with high rate-of-change-of frequency (ROCOF), which are more prevalent in high-IBR power systems. This paper first surveys frequency measurement methods that have been proposed to reduce measurement errors during transient events. Then, both conventional and more novel frequency measurement methods are tested against an IEEE standard and industry recommendations, and their performance is evaluated for events simulated in PSCAD. Results quantify the trade-offs in performance during different grid conditions and lead to suggestions for the most appropriate frequency and ROCOF measurement methods for low inertia grids.

frequency↗

Parametrized process characterization with reduced resource requirements

Quantum process tomography (QPT) is a powerful tool to characterize quantum operations, but it requires considerable resources, making it impractical for more than two-qubit systems. This study proposes an alternative approach that requires significantly fewer resources for unitary process characterization with a built-in method for state preparation and measurement error mitigation. By measuring the quantum process as rotated through the X and Y axes on the Bloch sphere, we can acquire enough information to reconstruct the quantum process matrix χ and measure its fidelity. We test the algorithm's performance against standard QPT using simulated and physical experiments on several IBM quantum processors and compare the resulting process matrices. We demonstrate with numerical experiments that the method can improve gate fidelity via a noise reduction in the imaginary part of the process matrix, along with a stark decrease in the number of experiments needed to perform the characterization.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Non-disruptive error field measurement in DIII-D low safety factor plasmas and projection to ITER

Previous experiments in DIII-D (Paz-Soldan et al 2022 Nucl. Fusion 62 126007) introduced a method to identify intrinsic error fields (EFs) in tokamaks with minimal disruption risk by promptly healing driven magnetic islands during the conventional 'compass scan'. This paper presents recent experimental and numerical advancements in extending this approach to low q 95 plasmas, and projects its applicability to ITER. Non-disruptive EF measurement is achieved at q 95 = 4.5 and 3.9 without any initial EF correction (EFC) by reducing the time between the occurrence of the locked mode (LM) and control action to 10 ms and increasing the density 50%–100%. However, 50% correction of the intrinsic EF is required to achieve island healing at q 95 = 3.2 with 10 ms delay for the control action. Nonlinear two-fluid modeling with the TM1 code reproduces the DIII-D experimental observations, indicating that promptly turning off the 3D coil current reduces both magnetic island width and electromagnetic force, while raising the density increases plasma viscosity, facilitating magnetic island healing. The simulations show that for scenarios with q 95 = 3.2, lowering the control action time to 5 ms will lead to island healing without EFC. TM1 simulations are extended to future ITER scenarios with 5 MA and 7.5 MA plasma currents, predicting the dependence of required density rise on action time and EF amplitude. These simulations indicate that, benefiting from the much longer resistive time, island healing can be successfully achieved in ITER when taking control action 100–500 ms after a LM occurrence.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Error field measurements with rotating RMP fields for DIII-D H-mode

3D magnetic sensors are employed to identify the amplitude and toroidal phase of error fields (EF) by analyzing the torque balance for magnetic islands entrained by rotating resonant magnetic perturbations (RMPs) in DIII-D H-mode plasmas. This technique of torque balance allows for efficient error field identification, offering a valuable tool for scenario-specific and optimized error field compensation (EFC) and requires only magnetic diagnostics. The torque balance used in this work includes the contribution from electromagnetic torque due to error fields, wall response, RMP fields, and viscous. Results show that viscous torque plays a crucial role, particularly during locked modes and H-mode plasmas, ensuring accurate data fits with lower residuals. The torque balance technique reveals that the L- and H-mode plasmas have distinct EF configurations, and consistent with a model-based EF analysis including MHD response in IPEC and the SURFMN EF simulation. This technique shows great robustness in measuring the intrinsic EF amplitude regardless of its amplitude or toroidal phase. Repeated discharges with EFC disparities exhibit consistent results of intrinsic error field within a reasonable range near the “standard” error field compensation. Additionally, the use of a rotating n = 1 resonant magnetic perturbation offers the advantage of reducing disruption risks by entraining saturated magnetic islands. These findings are instrumental for optimizing EF correction in fusion devices, thereby enhancing tearing mode suppression and overall plasma stability.

3D magnetic sensors↗

Open Source Fault-tolerant Grid Frequency Measurement for Solar Inverters

The Discrete Fourier transform (DFT) based measurement algorithms are one of the most common measurement algorithms for grid parameter estimation such as rms, phase angle, frequency. Over the past few years, many DFT based algorithms have been developed to enhance its measurement accuracy under steady-state and/or dynamic grid conditions. For example, an adaptive band-pass filter utilizing exponential modulation filter has been proposed to reduce measurement errors at the presence of large frequency deviations. Measurement accuracy of different algorithms including FIR filter, extended Kalman filtering (EKF), and enhanced DFT method have been compared in detail under different grid conditions. Two artificial signals that have 90-degree phase difference were constructed by the Clarke transformation to address the frequency spectrum leakage of DFT. A multi-module approach was developed to enhance both steady-state and dynamic measurement accuracies, in which each module was developed to eliminate some specific errors. Besides DFT-based measurement algorithms, some signal model-based algorithms have been developed to further improve the accuracy under dynamic conditions. However, a key drawback of the state-of-the-art algorithms is that they cannot perform measurements accurately during system transient faults. In the Blue Cut Fire event, there was a phase angle jump of about 26 degrees in the voltage waveform during the transient fault. The phase angle jump fault will cause waveform discontinuity, and these algorithms will fail to provide reliable measurements during this period because they typically assume the waveform to be measured is continuous, no matter what method (DFT, PLL, EKF, FIR, or Taylor WLS) is used for estimation. In fact, the measurement errors during the system transient faults like phase-jump is not required in the IEEE Standard. As a result, although a measurement instrument can pass the strict IEEE Standard, it could still be the source of the problem in the future if we have similar system transient faults, which could happen again. Therefore, developing the fault-tolerant measurement technology is the key to solve the problem.

14 SOLAR ENERGY↗

PDE-constrained high-order mesh optimization

Here, we present a novel framework for PDE-constrained r-adaptivity of high-order meshes. The proposed method formulates mesh movement as an optimization problem, with an objective function defined as a convex combination of a mesh quality metric and a measure of the accuracy of the PDE solution obtained via finite element discretization. The proposed formulation achieves optimized, well-defined high-order meshes by integrating mesh quality control, PDE solution accuracy, and robust gradient regularization. We adopt the Target-Matrix Optimization Paradigm to control geometric properties across the mesh, independent of the PDE of interest. To incorporate the accuracy of the PDE solution, we introduce error measures that control the finite element discretization error. The implicit dependence of these error measures on the mesh nodal positions is accurately captured by adjoint sensitivity analysis. Additionally, a convolution-based gradient regularization strategy is used to ensure stable and effective adaptation of high-order meshes. We demonstrate that the proposed framework can improve mesh quality and reduce the error by up to 10 times for the solution of Poisson and linear elasto-static problems. The approach is general with respect to the dimensionality, the order of the mesh, the types of mesh elements, and can be applied to any PDE that admits well-defined adjoint operators.

Computer science↗

Novel Lightweight, Low-Cost Heliostat for Concentrating Solar Power (SBIR Phase I Final Report)

The overall goal of this Department of Energy (DOE) SBIR Phase I project was to demonstrate the feasibility of the L.Garde, Inc. heliostat mirror facet for use in concentrated solar power applications. Prior to this Phase I project, L.Garde, Inc. developed a design for a lightweight and low cost mirror facet and successfully fabricated small scale (0.667 m 2 ) with a mirror surface flatness of 0.7 mrad. Therefore, the focus of the Phase I effort was to (1) demonstrate scalability by fabricating larger size mirrors while retaining the same mirror surface flatness, (2) demonstrate the design can withstand operating environment conditions through field testing, and (3) perform cost analysis to show the heliostat mirror facet design can meet DoE goals of < 12 kg/m2 and <$30/m 2 . During the Phase I project, L.Garde successfully fabricated large area (1.395 m 2 ) heliostat mirror facets, with a mass per unit area of 8 kg/m 2 and a cost of $29.80/m 2 . Surface flatness measurements (using contact probe technique) were performed on the mirror surface and results showed a flatness of 0.68 mrad, which were in agreement with previously fabricated small scale mirror facets. Slope error measurements was also performed on the mirror surface and results showed a slope error of 0.77 mrad which also was in agreement with previously fabricated small scale mirror facets. One large area mirror facet was subjected to a three (3) month field test. Surface flatness and slope error measurements were performed on the mirror surface after the field test and results were 0.663 mrad and 0.58 mrad respectively. The large scale heliostat mirror facets were also subjected to accelerated aging. However, during this exposure we observed failure due to the breaking of the mirror facets. Further investigation into the source of the failure showed that the mirror component alone showed signs of degradation during the same accelerated aging test. We believe that moisture ingress is occurring when subjected to high humidity, leading to buildup of water with the layers of protective paints and resulting in mirror breakage when water expands in freezing conditions. In order to mitigate or eliminate this issue, a new weatherproofing strategy may be implemented or a new mirror component may be used that is able to survive accelerated aging conditions.

14 SOLAR ENERGY↗

Development of Readily Available & Robust High Heat Flux Gardon Gauges

Concentrated solar power (CSP) technologies deliver concentrated solar energy as a heat source to industrial processes, power generation cycles, and chemical cycles. CSP systems require accurate and reliable high flux measurements, and next generation CSP systems will require flux measurement up to 1000 W/cm2. Existing flux measurement devices do not comprehensively meet the flux rating, cycle life, cost, and lead-time needs of stakeholders, necessitating the development of an improved flux sensor. In this study, Sandia National Laboratories (SNL) partnered with Hukseflux Thermal Sensors to develop a low-cost, short lead-time, and robust flux sensor rated to 250 W/cm2. Three prototype circular foil gauge designs were assessed for performance at the National Solar Thermal Test Facility (NSTTF) at SNL. Each gauge design measured flux up to 250 W/cm2 with <5% measurement error. Following baseline error quantification, gauges were exposed to flux above 500 W/cm2 to assess gauge failure mechanisms. Gauges physically survived >500 W/cm2 flux exposure, but measurement error was found to increase after foil coatings reached 400 °C. The results of this study suggest that coating optical properties change at excessive temperatures and that foil coating temperature, rather than heat flux level, dictates the acceptable gauge measurement range.

McLaughlin, Luke (ORCID:0000000303711310)↗

Bottom-up and Top-Down Uncertainty Quantification for Measurements

Several recent papers address improved uncertainty quantification (UQ) for measurements used in nuclear safeguards. This paper reviews progress and presents new results for bottom-up (first principles) and top-down (empirical) UQ for safeguards, where the main quantitative measure of uncertainty is the total measurement error standard deviation (SD), which includes both random and systematic error components. The five main UQ topics addressed here include: (1) impact of making data-driven choices in SD estimation; (2) use of approximate Bayesian computation (ABC) for both bottom-up and top-down UQ; (3) computational calibration; (4) revisions to the guide to the expression of uncertainty in measurement (GUM), and (5) critique of a recently-suggested “Unified Theory of Measurement Errors and Uncertainties.”

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗