Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “marginal costs”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Water and Climate Impacts on ERCOT Long-Term Systems Assessment

Water and climate change pose many potential challenges to the electric power system. Substantial water is withdrawn every day to support thermoelectric power generating unit operations, and changes to water supply have the potential to affect generation dispatch. Climate change can accelerate growing demand for electricity, which can necessitate additional generating capacity, often in locations with limited water supply. Drought conditions also threaten thermoelectric power plant operations due to streamflow and reservoir levels dropping below intake structures, or water temperatures exceeding a power plants' permitted operating conditions. Here we explore how future climate change might influence decisions related to electricity capacity expansion planning in Electric Reliability Council of Texas (ERCOT) using a multi-model framework. Specifically, water resource modeling is used to simulate climate impacts on the future water supply for thermoelectric and hydropower generation for four future climate projections. Separately, temperature impacts on electricity load are evaluated for these scenarios. These climate impacts are applied to five alternative electricity futures in an electricity capacity expansion model that projects future generation and transmission capacity additions in ERCOT. Results indicate that climate has a measurable influence on future generation and transmission capacity needs, with temperature-driven increases in peak and average load resulting in 5-15 GW additional generating capacity and up to 1 GW additional transmission capacity. Additional capacity is a diverse mix of PV, natural gas, and wind, depending on the makeup of economic, policy and technology assumptions. Climate impacts increase total system costs 2-5%, while the marginal cost of energy and emissions are not affected substantially by climate change effects.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Cost-Benefit Assessment of Krypton and Xenon Recovery from Aqueous Reprocessing

The purpose of this paper is to provide an understanding of the cost-benefit of capturing Kr and Xe from the existing process of aqueous reprocessing of UNF. The study accomplishes this with a market assessment of Xe prices and volumes today, coupled with a cost estimate of Kr and Xe capture out of cryogenic distillation within aqueous reprocessing. The market assessment shows that the average price of Xe is about $\$ $60/L while the average price of Kr is about $\$ $1/L. The assessment also shows that the market structure for Xe is one of oligopoly, in other words, very few suppliers to the Xe market. The assessment shows growing demand for Xe, particularly in medical applications like anesthesia. The cost assessment finds the unit cost of Xe to range from $\$ $71.50/L to $\$ $131.13/L. This range is only slightly above the current range of market prices today, and with growing demand for Xe, prices could reach the range it would take to support extraction of Xe from aqueous reprocessing. On the other hand, the estimated cost range for Kr is $\$ $830.15/L up to $\$ $1,522.52/L, which far exceeds the range of market prices for Kr. However, as the text notes, Kr capture is already part of aqueous reprocessing so these costs are sunk costs (already incurred) whereas the cost estimates for Xe are marginal cost (if Xe is desired, then the cost estimate would result from the Xe capture).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A scoping study of far-SOL main-wall protection limiters for steady-state operation of compact pilot plant tokamaks

We present a novel method for handling steady-state heat fluxes incident on the main wall of pilot plant-scale magnetic fusion devices, based on the utilization of protection limiters in the far scrape-off layer (SOL). This method helps avoid large plasma-wall gaps, without excessively compromising blanket performance. We present an optimization algorithm for determining the appropriate size and scale of these protection limiters given (1) probability distributions of SOL plasma parameters and (2) assumed risk tolerance. As part of this optimization, we have developed an analytic description of parallel heat fluxes across limiter shadows, and an objective cost function (the ‘Far-SOL Marginal Cost’) to quantify the impact that different main-wall thermal management design choices have on reactor capital cost. Applying the model to a midscale fusion pilot plant concept shows that making use of far-SOL protection limiters can reduce capital costs on the order of $500 M, relative to naively increasing the plasma-wall gap. Our analysis demonstrates that the far-SOL power decay length is the highest-leverage plasma assumption for thermal loading of the first wall, and the primary cost driver for main wall thermal management. The relative cost efficiency of protection limiters increases as assumptions on the far-SOL heat flux become more pessimistic. The concepts described in this paper motivate the further development of far-SOL protection limiters as part of larger efforts to design economical core-edge-wall compatible solutions for a fusion pilot plant.

Design under uncertainty↗

Estimation of abatement potentials and costs of air pollution emissions in China

Understanding the air pollution emission abatement potential and associated control cost is a prerequisite to design cost ef?cient control policies. In this study, a linear programming algorithm model, International Control Cost Estimate Tool, was updated with cost data for applications of 56 types of end-of-pipe technologies and ?ve types of renewable energy in 10 major sectors namely power generation, industry combustion, cement pro-duction, iron and steel production, other industry processes, domestic combustion, transportation, solvent use, livestock rearing, and fertilizer use. The updated model was implemented to estimate the abatement potential and marginal cost of multiple pollutants in China. The total maximum abatement potentials of sulfur dioxide (SO2), nitrogen oxides (NOx), primary particulate matter (PM2.5), non-volatile organic compounds (NMVOCs), and ammonia (NH3) in China were estimated to be 19.2, 20.8, 9.1, 17.2 and 8.6 Mt, respectively, which accounted for 89.7%, 89.9%, 94.6%, 74.0%, and 80.2% of their total emissions in 2014, respectively. The associated control cost of such reductions was estimated as 92.5, 469.7, 75.7, 449.0, and 361.8 billion CNY in SO2, NOx, primary PM2.5, NMVOCs and NH3, respectively. Shandong, Jiangsu, Henan, Zhejiang, and Guangdong provinces exhibited large abatement potentials for all pollutants. Provincial disparity analysis shows that high GDP regions tend to have higher reduction potential and total abatement costs. End-of-pipe technologies tended be a cost-ef?cient way to control pollution in industries processes (i.e., cement plants, iron and steel plants, lime production, building ceramic production, glass and brick production), whereas such technologies were less cost- effective in fossil fuel-related sectors (i.e., power plants, industry combustion, domestic combustion, and transportation) compared with renewable energy. The abatement potentials and marginal abatement cost curves developed in this study can further be used as a crucial component in an integrated model to design optimized cost-ef?cient control policies.

Zhang, Fenfen↗

Comparison of Long-Term Bioenergy with Carbon Capture and Storage to Reference Power Generation Technologies Using CO2 Avoidance Cost in the U.S.

Bioenergy with carbon capture and storage (BECCS) can sequester atmospheric CO2, while producing electricity. The CO2 avoidance cost (CAC) is used to calculate the marginal cost of avoided CO2 emissions for BECCS as compared to other established energy technologies. A comparative analysis using four different reference-case power plants for CAC calculations is performed here to evaluate the CO2 avoidance cost of BECCS implementation. Results from this work demonstrate that BECCS can generate electricity at costs competitive with other neutral emissions technologies, while simultaneously removing CO2 from the atmosphere. Approximately 73% of current coal power plants are approaching retirement by the year 2035 in the U.S. After considering CO2 sequestered from the atmosphere and coal power plant CO2 emissions displaced by BECCS, CO2 emissions can be reduced by 1.4 billion tonnes per year in the U.S. alone at a cost of $88 to $116 per tonne of CO2 removed from the atmosphere, for 10% to 90% of available biomass used, respectively. CAC calculations in this paper indicate that BECCS can help the U.S. and other countries transition to a decarbonized electricity grid, as simulations presented in this paper predict that BECCS power plants operate at lower CACs than coal plants with CCS.

25 ENERGY STORAGE↗

Optimal design of solar-driven electrolytic hydrogen production systems within electricity markets

Hydrogen has the potential to be a key contributor toward a low-carbon economy. Generating hydrogen by electrolysis using renewable energy is one way to support a decarbonized economy; however, its cost is not typically competitive with the carbon-emitting incumbent technology, steam methane reforming. The ability of electrolysis to integrate with electricity markets presents a unique cost reduction opportunity due to the perceived future availability of low and zero-marginal cost renewable energy sources. Additionally, as renewables, and particularly, photovoltaics are installed on the grid, they have a value deflation effect. This work evaluates solar-electrolysis configurations using a mathematical programming framework to maximize system net present value. The framework has been tested with specific weather conditions and financial mechanisms in California. Our findings indicate that a spectrum of potential cost competitive solutions is available for systems that (i) have market configurations resembling hybrid retail/wholesale, resulting in a hydrogen production cost range of US$6.2 kg-1–US$6.6 kg-1, or full wholesale market participation, reducing production cost to US$2.6 kg-1–US$3.1 kg-1, and (ii) achieve projected future cost reductions.

08 HYDROGEN↗

Oxygen Storage Incorporated Into Net Power and the Allam–Fetvedt Oxy-Fuel sCO2 Power Cycle—Techno-Economic Analysis

Abstract With the planned future reliance on variable renewable energy, the ability to store energy for prolonged time periods will be required to reduce the disruption of market fluctuations. This paper presents a method to analyze a hybrid liquid-oxygen (LOx) storage/direct-fired supercritical carbon dioxide (sCO2) power cycle and optimize the economic performance over a diverse range of scenarios. The system utilizes a modified version of the NET Power process to produce energy when energy demand exceeds the supply while displacing much of the cost of the air separation unit (ASU) energy requirements through cryogenic storage of oxygen. The model uses marginal cost of energy data to determine the optimal times to charge and discharge the system over a given scenario. The model then applies ramp rates and other time-dependent factors to generate an economic model for the system without storage considerations. The size of the storage system is then applied to create a realistic model of the plant operation. From the real plant operation model, the amount of energy charged and discharged, the capital expenditures (CAPEX) of each system, energy costs and revenue and other parameters can be calculated. The economic parameters are then combined to calculate the net present value (NPV) of the system for the given scenario. The model was then run through the SMPSO genetic algorithm in Python for a variety of geographic regions and large-scale scenarios (high solar penetration) to maximize the NPV based on multiple parameters for each subsystem. The LOx storage requirements will also be discussed.

Engineering↗

Advancing Pumped Thermal Energy Storage Performance and Cost Using Silica Storage Media

Pumped Thermal Energy Storage (PTES) is an electricity storage system that is suitable for long-duration energy storage (10-1000 h) due to its low marginal cost of energy capacity. We present a techno-economic model of a PTES system that uses particle thermal energy storage. Particles have low costs and can be operated over a wide temperature range leading to increased efficiency and reduced costs compared to other PTES designs. We show how the round-trip efficiency, specific power output, capital cost, and levelized cost of storage (LCOS) depend on parameters such as the pressure ratio, heat exchanger approach temperature and pressure loss, and maximum temperature. We compare particle-PTES (P-PTES) performance to PTES which uses liquid thermal energy storage - i.e. molten salt hot storage and methanol cold storage (MS-PTES). We find that using silica particles for storage advances PTES technology: P-PTES can be operated at higher maximum temperatures than MS-PTES. Furthermore, P-PTES can achieve lower approach temperatures in the heat exchangers than MS-PTES without increasing capital costs, because P-PTES uses direct-contact heat transfer in fluidized bed heat exchangers. As a result, we find that P-PTES systems achieve higher round-trip efficiency than MS-PTES (66 % versus 57 %) and lower LCOS (e.g. 0.115 +- 0.03 $/kWhe versus 0.171 +- 0.04 $/kWhe for 10 h discharge). The low cost of particles and containment means that P-PTES can provide long-duration energy storage at low capital cost per unit energy capacity. For example, the total capital cost per unit energy reduces from 245 $/kWhe at 10 h to 38 $/kWhe at 100 h. These costs are considerably lower than MS-PTES (72 $/kWhe at 100 h) and also outcompete current and future Li-ion battery system projections (100-265 $/kWhe).

25 ENERGY STORAGE↗

Evaluating the efficacy of aluminide coatings to improve oxidation resistance of high performance engine valve alloys

Increasing peak cylinder pressures and operating temperatures of turbo-charged internal combustion engines (ICEs) engines present new challenges for existing materials employed in engine exhaust valves. Oxidation induced degradation of current Ni based alloys for these components will be a life-limiting mechanism while strict cost margins in the automotive transportation industry further limit the choice of suitable candidate materials. Metallic diffusion aluminide coatings can provide a cost-effective way to improve the oxidation resistance of underlying materials. In this study, the high temperature oxidation behavior of diffusion nickel aluminide coatings on two Ni based alloys (commercially available alloy 31V and a developmental alloy) during cyclic oxidation behavior in air+10% H 2 O at 900 °C was investigated. A complete depletion of the beneficial Al-rich β-(NiFe)Al phase was observed in the coating on alloy 31V while a significant fraction of this phase was retained in the coating on the second alloy. A coupled thermodynamic-kinetic model showed that the disappearance of the Al-rich phase in the coating on 31V was mainly due to the combined effect of steeper chemical potential gradients of Al and Ti between the coating and the substrate and their faster diffusivities compared to the coated developmental alloy. Finally, a higher content of Fe was shown to support the retention of β-(NiFe)Al phase in the coating on the developmental alloy while the presence of Ti in the alloy was shown to be detrimental for long-term coating performance.

36 MATERIALS SCIENCE↗

Funding a Just Transition Away from Coal in the U.S. Considering Avoided Damage from Air Pollution

Abstract Coal is declining in the U.S. as part of the clean energy transition, resulting in remarkable air pollution benefits for the American public and significant costs for the industry. Using the AP3 integrated assessment model, we estimate that fewer emissions of sulfur dioxide, nitrogen oxides, and primary fine particulate matter driven by coal’s decline led to $300 billion in benefits from 2014 to 2019. Conversely, we find that job losses driven by less coal plant and mining activity resulted in $7.84 billion in foregone wages over the same timeframe. While the benefits were greatly distributed (mostly throughout the East), costs were highly concentrated in coal communities. Transferring a small fraction of the benefits to workers could cover these costs while maintaining societal net benefits. Forecasting coal fleet damages from 2020 to 2035, we find that buying out or replacing these plants would result in $589 billion in air quality benefits, which considerably outweigh the costs. The return on investment increases when policy targets the most damaging capacity, and net benefits are maximized when removing just facilities where marginal benefits exceed marginal costs. Evaluating competitive reverse auction policy designs akin to Germany’s Coal Exit Act, we find that adjusting bids based on monetary damages rather than based only on carbon dioxide emissions – the German design – provides a welfare advantage. Our benefit–cost analyses clearly support policies that drive a swift and just transition away from coal, thereby clearing the air while supporting communities needing assistance.

Dennin, Luke R. (ORCID:0000000205405520)↗

Decarbonization of the Electric Power Sector and Implications for Low-Cost Hydrogen Production from Water Electrolysis

Increasing development of wind and solar generation in the power sector can create economic opportunities for the deployment of water electrolyzers that produce hydrogen. Temporal variation in the marginal cost of energy in future decarbonized grids can make it favorable for electrolyzers to dispatchably ramp hydrogen production up and down in response to low- and high-cost times. Using this strategy, low-cost hydrogen production is enabled by electrolyzers that are low-capital cost and tolerant to frequent on/off cycling. Ramping down hydrogen production to a designated turndown ratio can avoid performance degradation caused by on/off cycling by not shutting the electrolyzer completely off. This comes with a slight cost penalty which can be minimized if the turndown ratio is low (i.e., the system ramps down hydrogen production to close to zero). These results suggest that electrolyzers integrated into future power systems are likely to benefit from the ability to ramp operation up and down quickly and operate in a standby mode. This analysis forms a basis for comparative tradeoffs between electrolyzer capital cost, operating strategy, and system durability and demonstrates the importance of considering all three factors in technoeconomic analysis.

capital cost↗

The Economics of Power System Transitions

Electricity generated by fossil fuels is dispatchable, meaning that generators can be turned on when needed. By contrast, renewable energy tends to be intermittent because of the variability of natural sources such as wind and sunlight. New approaches are needed to solve the challenges to electricity systems posed by the growing share of variable renewable energy (VRE) in these systems. Specifically, how should the physical power system and markets for electricity be structured to deliver electricity at low cost and reflect consumers’ preferences for reliability? Current power systems have largely achieved these two goals through a competitive market for generation based on marginal cost pricing and through mandated overcapacity to ensure 100 percent reliability to consumers. Decarbonization-induced increases in the share of generation from nondispatchable VRE create operational challenges: ensuring 100 percent reliability in a VRE-dominated system will be costly and inefficient. Preferences for reliability are heterogeneous, as some consumers will insist on 100 percent reliable energy, whereas others may be willing to forgo reliability for lower cost. In this article, we discuss ways to design a power system and electricity market that can address this inefficiency.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Storage Futures Study: Grid Operational Impacts of Widespread Storage Deployment

This report, the fifth in the Storage Futures Study series, uses cost-driven scenarios from the ReEDS model as a starting point to examine the operational impacts of grid-scale storage deployment and relationships between this deployment and the contribution of variable renewable energy. We use commercial production cost modeling software to evaluate hourly operation of five scenarios that reach between 210 gigawatts (GW) and 930 GW of installed storage by 2050. We find that storage plays an important role in these power systems between now and 2050 - by storing the lowest-marginal cost generation (often, overgeneration from solar or wind plants) and generating energy during the highest net load periods of the day and year. Storage helps with the integration of variable renewable energy and by providing an important resource to provide continued reliable power.

25 ENERGY STORAGE↗

Storage Futures Study: Grid Operational Impacts of Widespread Storage Deployment

This report, the fifth in the Storage Futures Study series, uses cost-driven scenarios from the ReEDS model as a starting point to examine the operational impacts of grid-scale storage deployment and relationships between this deployment and the contribution of variable renewable energy. We use commercial production cost modeling software to evaluate hourly operation of five scenarios that reach between 210 gigawatts (GW) and 930 GW of installed storage by 2050. We find that storage plays an important role in these power systems between now and 2050 - by storing the lowest-marginal cost generation (often, overgeneration from solar or wind plants) and generating energy during the highest net load periods of the day and year. Storage helps with the integration of variable renewable energy and by providing an important resource to provide continued reliable power.

battery↗

The Economic Accessibility of CO2 Sequestration through Bioenergy with Carbon Capture and Storage (BECCS) in the US

Bioenergy with carbon capture and storage (BECCS) is one strategy to remove CO2 from the atmosphere. To assess the potential scale and cost of CO2 sequestration from BECCS in the US, this analysis models carbon sequestration net of supply chain emissions and costs of biomass production, delivery, power generation, and CO2 capture and sequestration in saline formations. The analysis includes two biomass supply scenarios (near-term and long-term), two biomass logistics scenarios (conventional and pelletized), and two generation technologies (pulverized combustion and integrated gasification combined cycle). Results show marginal cost per tonne CO2 (accounting for costs of electricity and CO2 emissions of reference power generation scenarios) as a function of CO2 sequestered (simulating capture of up to 90% of total CO2 sequestration potential) and associated spatial distribution of resources and generation locations for the array of scenario options. Under a near-term scenario using up to 206 million tonnes per year of biomass, up to 181 million tonnes CO2 can be sequestered annually at scenario-average costs ranging from $62 to $137 per tonne CO2; under a long-term scenario using up to 740 million tonnes per year of biomass, up to 737 million tonnes CO2 can be sequestered annually at scenario-average costs ranging from $42 to $92 per tonne CO2. These estimates of CO2 sequestration potential may be reduced if future competing demand reduces resource availability or may be increased if displaced emissions from conventional power sources are included. Results suggest there are large-scale opportunities to implement BECCS at moderate cost in the US, particularly in the Midwest, Plains States, and Texas.

09 BIOMASS FUELS↗

Quantifying the challenge of reaching a 100% renewable energy power system for the United States

We simulate pathways for achieving up to 100% renewable energy (RE) electric power systems for the contiguous United States. Under base conditions, the least-cost buildout has RE penetration growing up to 57% in 2050. Relative to this base scenario, average CO2 abatement costs of achieving 80%, 90%, 95%, and 100% RE are $25, $33, $40, and $61/ton, respectively, with system costs growing from $30 to $36/MWh at 95% (achieved in 2040) and $39/MWh at 100%. Incremental abatement costs from 99% to 100% RE reach $930/ton, driven primarily by the need for firm RE capacity. In addition to the base conditions, we also examined 22 alternative conditions for a buildout of up to 100%. These sensitivities capture different technology trajectories, compliance requirements, requirement timing, electrification, and transmission availability. Nonlinear marginal costs for the last few percent approaching 100% RE were found for all sensitivities, which might motivate alternative nonelectric-sector abatement opportunities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Demonstration System for Geological Thermal Energy Storage of Concentrating Solar Thermal

Energy storage is increasingly necessary as variable energy technologies are deployed. Seasonal energy storage can shift energy generation from the summer to the winter, but these technologies must have extremely large energy capacities and low costs. Geological Thermal Energy Storage (GeoTES) is proposed as a solution for long-term energy storage [1]. Excess thermal energy can be stored in permeable reservoirs such as aquifers and depleted hydrocarbon reservoirs for several months. The energy capacity cost of GeoTES is very low which makes it suitable for both daily- and seasonal storage of Concentrating Solar Thermal (CST) energy, thus enabling CST to provide value to electricity markets and thermal energy off-takers. A CST-GeoTES demonstration system has been funded by the U.S. Department of Energy, Solar Energy Technology Office. In this article, we will describe this demonstration system and progress that has been made in its development. The demonstration system will comprise a 2 MWth parabolic trough with an 8m aperture developed by Gossamer Space Frames, seven wells, and a 100 kWe power cycle. The demonstration system will be deployed in Kern County, California by Premier Resource Management. A techno-economic model for CST-GeoTES systems has also been developed [3] and is applied to the demonstration system and its planned future expansion. The model integrates the output of specialist models of each subsystem, which enables the performance and cost of both the subsurface and surface systems to be captured. Off-design models enable the performance to be evaluated at each hour of the year, before being aggregated to evaluate the economic potential of CST-GeoTES. Initial analysis indicates that CST-GeoTES can provide long duration energy storage capabilities with low marginal costs of energy capacity - leading to a low value of Levelized Cost of Storage (LCOS) compared to alternative technologies, see Figure 2. In this article, we investigate the cost and performance of the specific demonstration site being developed by PRM and explore a range of operational profiles that can deliver different value streams, such as daily and seasonal storage, capacity, and resiliancy.

14 SOLAR ENERGY↗

Quantitative analysis of cost savings and occupants’ preferences in grid-interactive smart home operation

Many utility companies in the United States have introduced time-of-use (TOU) rates for homeowners with the goal of regulating electricity consumption during peak hours. The electrical appliances in homes include various thermostatically controlled devices, such as air conditioners (AC) for thermal comfort, and nonthermostatically controlled devices such as clothes washers. As a result, homeowners face the complicated challenge of economically operating multiple electrical appliances in their homes while maintaining comfort and convenience. This is usually due to the lack of an explicit understanding of the correlation between cost saving and the users’ comfort. To understand the correlation, this article is designed to construct a framework by integrating three major components: a multi-objective optimization method accommodating multiple competing goals with different weights, a learning-based system modeling approach describing the dynamics and thermal coupling effects of appliances, and a novel comfort index method differentiating preferred and acceptable thermal comfort. Our proposed framework can allow the indoor air temperature to fall into the "preferred" range with a marginal cost increase. Furthermore, the simulation result shows that an additional 8 h for the preferred thermal comfort can be achieved with a cost increase of only 1.77%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗