Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “lost load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Cost-Benefit Analysis of Electricity Resilience Projects: State of the Art and Gap Analysis

Utilities and regulators must weigh the benefits of electricity resilience projects against their costs, which would be passed on to customers. Cost-benefit analysis (CBA) is an appropriate method for assessing this tradeoff. Here, in this paper we review the literature on CBA of electricity resilience projects and analyze gaps in the available methods and tools. The costs of resilience projects are typically straightforward to estimate but their benefits — particularly the avoided costs of power interruptions — are complex to quantify and monetize. A common perception among practitioners is that current CBA tools are not sufficiently mature to be adopted into real-world practice. We propose an electricity resilience CBA framework consisting of several elements: risks, physical impacts, power interruptions, economic impacts, and resilience projects. While methods for some elements are well-developed, there is a need for novel approaches to value avoided power interruptions, integrate multiple risks and benefit streams, and incorporate uncertainty.

Cost-benefit analysis↗

Planning for the storm: Considering renewable energy for critical infrastructure resilience

This study uses the renewable energy optimization model to assess three critical facilities in North Carolina. Techno-economic results were then compared to analyses completed for critical facilities in California and New York to assess energy system cost effectiveness. Though solar photovoltaic (PV) arrays are cost-effective across each of the three North Carolina facilities, adopting battery storage to enable PV to operate with existing diesel generators in a hybrid energy system reduces the economic value of the system. This is in contrast to more economically viable systems in California and New York. All of these systems also offer unquantified resilience benefits by extending operation from hours to weeks across the facilities. If decision makers were able to value the resilience benefits offered by each system or utility rate structures were changed to incentivize battery storage during normal operations, it would impact these assessments. Even so, this analysis provides decision makers a key set of cost benchmarks when considering how they might improve resilience at their critical operations.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Understand the Costs of an Energy or Water Outage with the Customer Damage Function Calculator

The Customer Damage Function (CDF) Calculator is a free, publicly available web tool that helps users estimate the costs incurred at their site due to an electric grid or water service outage. Developed by the National Renewable Energy Laboratory (NREL) with support from the Federal Energy Management Program (FEMP), the tool is designed to help federal facility owners, building energy managers, and resilience planners understand and quantify the value of resilience to justify investments that would prevent or lessen the impact of a disruption.

CDF Calculator↗

High temperature secondary hydriding experiments with E110 and E110g claddings - 6.5 STP-2016-0031

Secondary hydriding can take place during a LOCA (loss of coolant accident) event after the ballooning and burst of Zr cladding. The oxidation and hydrogen uptake in the ballooned section can produce the weakest segment of the rod. This phenomenon was investigated in the past mainly for Zircaloy-4 cladding. The objective of the present work was the investigation of the effect of secondary hydriding in VVER reactors with E110 and E110G alloys. High temperature facility was built to carry out high temperature treatment of fuel cladding samples. The burst of tubes was reached with inner pressurization at 750 deg. C and 800 deg. C. After burst the samples were oxidized in the same furnace for different periods and at different temperatures. The oxidized samples were tested in tensile test machine with four point bending tests. The microstructure of samples was analyzed by optical and scanning microscopy. The hydrogen content of the cladding was measured by hot extraction, prompt gamma activation analyses and neutron radiography methods. The experiments indicated that the ballooned section after oxidation becomes the weakest segment of the VVER fuel, too. According to the mechanical testing the cladding samples even after short oxidation time (200 s at 1000 deg. C) were brittle without any sign of ductile behavior. The comparison of E110 and E110G samples showed that the E110 tubes lost their load bearing capability or even integrity much earlier than the E110G samples treated under similar conditions. (authors)

36 MATERIALS SCIENCE↗

Coupling of Thermal Energy Storage with Small Modular Reactors

Thermal energy storage has been proposed as a load management strategy for Small Modular Reactors (SMRs) deployed on constrained grids and/or in hybrid energy systems (1). Hybrid energy systems can include process steam applications, and the presence of intermittent energy sources such as wind and solar. Under these conditions, the reactor can be subjected to significant time varying electric loads. One strategy for accommodating these loads is to operate the reactor in a load follow mode where reactor power is modulated to match the electric demand. In addition to lost energy potential, load follow operation can result in additional stresses on the fuel and other mechanical components. A more attractive approach is to operate the reactor at or near steady state and bypass excess steam to a thermal energy storage system. The thermal energy can then be recovered later, either for electric generation during periods of peak electric demand, or for uses in process steam applications. In previous work, the design of a sensible heat Thermal Energy Storage (TES) system was proposed for SMR applications (2). In this paper we examine coupling of the TES system to a SMR, typical of Integral Pressurized Water Reactor (IPWR) designs currently under development. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Control strategies for coupling thermal energy storage systems with small modular reactors - 188

The contribution of intermittent (renewable) energy sources such as wind and solar continues to increase as renewables improve in both efficiency and price-point. However, the variability of renewables generates additional challenges for the electric grid in the form of rapidly varying electric loads. Proposed options for accommodating this load have included operating nuclear reactors in a load follow mode, or operating the reactor at or near steady state and bypassing steam directly to the condenser. Both of these strategies result in lost energy potential. In addition to lost energy potential, load follow operation can result in increased stress on the fuel and other mechanical components. A more attractive approach is to operate the reactor at or near steady state and bypass excess steam to a thermal energy storage system. The thermal energy can then be recovered, either for electric generation during periods of peak electric demand, or for use in ancillary applications such as desalination and hydrogen production. Sensible Heat Thermal Energy Storage is a mature technology currently used in solar energy systems. This research focuses on the design and coupling of such a system to Small Modular Reactors (SMRs), typical of Integral Pressurized Water Reactor (IPWR) designs currently under development. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

High-temperature secondary hydriding experiments with E110 and E110G claddings - 2016-0031

Secondary hydriding can take place during a loss-of-coolant accident event after the ballooning and burst of the zirconium alloy cladding. The oxidation and hydrogen uptake in the ballooned section can produce the weakest segment of the rod. This phenomenon was investigated in the past mainly for Zircaloy-4 cladding. We investigated the effect of secondary hydriding in VVER reactors with E110 and E110G alloys. A high-temperature facility was built to carry out high-temperature treatment of fuel cladding samples. The burst of tubes was reached with inner pressurization at 750 and 800 C. After burst the samples were oxidized in the same furnace for different periods and at different temperatures. The oxidized samples were tested in a tensile test machine with four-point bending tests. The microstructure of the samples was analyzed by optical and scanning electron microscopy. The hydrogen content of the cladding was measured by heat extraction, prompt gamma activation analyses, and neutron radiography methods. The experiments indicated that the ballooned section after oxidation became the weakest segment of the VVER fuel. According to the mechanical testing, the cladding samples were brittle even after a short oxidation time (200 s at 1,000 C) without any sign of ductile behavior. The comparison of E110 and E110G samples showed that the E110 tubes lost their load-bearing capability or even integrity much earlier than the E110G samples treated under similar conditions. (authors)

36 MATERIALS SCIENCE↗

Uniform redundancy allocation maximizes the robustness of flow networks against cascading failures

We study the robustness of flow networks against cascading failures under a partial load redistribution model. In particular, we consider a flow network of N lines with initial loads L 1 ,...,L N and free spaces (i.e., redundant space) S 1 ,...,S N that are independent and identically distributed with joint distribution P LS (x,y) = P[L ≤ x, S ≤ y]. The capacity C i is the maximum load allowed on line i and is given by C i = L i + S i . Furthermore, when a line fails due to overloading, it is removed from the system and (1 – ε) fraction of the load it was carrying is redistributed equally among all remaining lines in the system. The rest (i.e., ε fraction) of the load is assumed to be lost or absorbed, e.g., due to advanced circuitry disconnecting overloaded power lines or an interconnected network or material absorbing a fraction of the flow from overloaded lines. We analyze the robustness of this flow network against random attacks that remove a p fraction of the lines. Our contributions include (i) deriving the final fraction of alive lines n ∞ (p,ε) for all p,εϵ(0,1) and confirming the results via extensive simulations; (ii) showing that partial redistribution might lead to (depending on the parameter 0 < ε ≤ 1) the order of transition at the critical attack size p* changing from first to second-order; and (iii) proving analytically that flow networks achieve maximum robustness [quantified by the area ∫$^{1}_{0}$ n ∞ (p,ε)dp] when all lines have the same free space regardless of their initial load. The optimality of equal free-space allocation is also confirmed on real-world data from the UK National Power Grid.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Hydrolysis‐determining substrate characteristics in liquid hot water pretreated hardwood

ABSTRACT Fundamental characterization of pretreated hardwood and its interactions with cellulolytic enzymes has confirmed that a pathway exists for dramatically reducing the loading of cellulase required for hydrolysis of pretreated biomass. We demonstrate that addition of protein effecting a seven‐fold decrease in the specific activity of cellulases enables a ten‐fold reduction in enzyme loading while maintaining a high level of cellulose hydrolysis in pretreated hardwood. While use of protein and other additives that adsorb on lignin have been reported previously, the current work demonstrates the effect in a dramatic manner and brings the rationale for this change into clear focus. The key to this result is recognizing and mitigating the pretreatment conundrum where increasingly severe pretreatment conditions enhance accessibility of the enzymes not only to cellulose, but also to lignin. The lignin adsorbs enzyme protein causing loss of cellulase activity. More enzyme, added to compensate for this lost activity, results in a higher cellulase loading. The addition of a different protein, such as BSA, prevents cellulase adsorption on lignin and enables the enzyme itself to better target its glucan substrate. This effect dramatically reduces the amount of cellulase for a given level of conversion with enzyme loadings of 15 FPU and 1.3 FPU/g solids both achieving 80% conversion. The understanding of this phenomenon reinvigorates motivation for the search for other approaches that prevent cellulase adsorption on lignin in order to achieve high glucose yields at low enzyme loadings for pretreated lignocellulose. Biotechnol. Bioeng. 2015;112: 677–687. © 2014 Wiley Periodicals, Inc.

Kim, Youngmi↗

Mechanical behavior analysis using small-size graphite disc compression testing with digital image correlation methods

The ASTM International Standard Test Method for Tensile Stress-Strain of Carbon and Graphite (ASTM C749) requires dog-bone shaped specimens. Unfortunately, specimen sizes required in ASTM C749 are much too large for irradiation within a test reactor and are incompatible with irradiation capsule volumes, molten salt degradation facilities, or oxidation apparatus. The ASTM International Standard Test Method for Tensile Strength Estimate by Disc Compression of Manufactured Graphite (ASTM D8289) was developed as an alternative that provides a means for testing tensile properties using smaller specimens when geometric constraints are present. However, the important stress–strain relation throughout the test loading history that could be recorded using ASTM C749 is lost by using ASTM D8289 because of the difficulties involved with using traditional strain gauges or extensometers on such a small specimen. In this work, a digital image correlation (DIC) method, which uses a full-field noncontact surface displacement measurement technique, was applied along with the ASTM D8289 splitting tensile test on eight small samples of graphite grade Mersen 2114 to track their deformation during compressive loading. Initial results showed that the DIC technique can measure the surface displacement/strain on these small (Ø6 × 3 mm) graphite specimens with high accuracy and good repeatability, indicating that the DIC technique, combined with the small-disc splitting tensile test in ASTM D8289, can capture the strain evolution in the test. In conclusion, further comparison of measured strains with analytical and numerical simulation results provides additional understanding of the mechanical behaviour of this nuclear graphite material in complex stress states.

36 MATERIALS SCIENCE↗

Cold plasma finite element wave model for helicon waves

Helicon waves have been recently proposed as an off-axis current drive actuator due to their expected high current drive efficiency in the mid-radius region in high beta tokamaks. This current drive efficiency has mostly been calculated ignoring the effects of the plasma in the scrape-off-layer (SOL) in the modeling. The net core current drive efficiency will decrease if helicon power is lost to the SOL. Previous efforts to estimate the loss of helicon power in the SOL have used the hot plasma code AORSA. The large computational cost of AORSA prevents large parametric scans, so to further the understanding of helicon power loss in the SOL, a reduced finite element, full wave plasma model with effective collision frequency for collisional and Landau damping has been developed to study the helicon wave power lost to the SOL. It will be shown that the reduced finite element model (FEM) can reproduce the magnitude and trends of helicon |E| field patterns and power loss in the SOL of the hot plasma AORSA model. The reduced FEM provides significant advantages over AORSA in reducing the computational time and memory requirements, and in simulating arbitrary tokamak vessel geometry. Parametric scans of antenna parallel refractive index, antenna location, minimum SOL density, SOL density gradient, and vacuum vessel geometry will be carried out to determine the dependencies of the helicon power lost to the SOL as a function of important parameters. Subsequently, the helicon cutoff density is shown to be an important quantity in determining helicon power lost to the SOL. Furthermore, losses due to antenna loading and wave accessibility are also observed at different antenna and plasma parameters.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Sensitivity of Spent Fuel Temperatures to Variable Canister Backfills

This report describes thermal modeling done to understand the effects of a hypothetical loss of backfill to a spent fuel storage canister. A NAC MAGNASTOR system was analyzed using STAR-CCM+ and COBRA-SFS at various heat loads, helium pressures, and air environments. When helium was lost later in life the results showed no safety impact to the thermal performance of the cask system and fuel cladding. However, there were other results of interest from this study. The potential to detect helium leaks using external temperature measurement was considered and found to be a potential area for future technology development. The other major result of interest was the significant change in flow velocities with an air environment. This data will be useful in understanding the potential impacts of a breached canister.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

High efficiency stoichiometric internal combustion engine system

A power system including a stoichiometric compression ignition engine in which a roots blower is positioned in the air intake for the engine to control air flow. Air flow is decreased during part power conditions to maintain the air-fuel ratio in the combustion chamber of the engine at stoichiometric, thus enabling the use of inexpensive three-way catalyst to reduce oxides of nitrogen. The roots blower is connected to a motor generator so that when air flow is reduced, electrical energy is stored which is made available either to the roots blower to temporarily increase air flow or to the system electrical load and thus recapture energy that would otherwise be lost in reducing air flow.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Dynamic modeling to minimize energy use for CO{sub 2} capture in power plants by aqueous monoethanolamine

A dynamic rate-based model was developed for stripping in CO{sub 2} capture from coal-fired power plants with 30 wt% monoethanolamine (MEA). The model, created in a flow sheet of Aspen Custom Modeler, was based on the film theory for liquid and vapor phases. It takes into account the impact of equilibrium reactions on the mass transfer, thermodynamic nonidealities, and the hydraulics of the structured packing. With this model, steady state analyses were. carried out for the stripper to understand the effect of the leah loading and the height of the packing on total equivalent work and find optimum operating conditions that minimize power plant lost work. Two dynamic strategies with control configurations are proposed to run the stripper in a flexible operation during the period of electricity peak load and prices. Open loop responses demonstrated some differences in dynamic behavior and steady state values for proposed dynamic strategies. One of the approaches increased the CO{sub 2} removal by 1% at the reduced steam rate and provided faster response of the stripper to a step change in the reboiler heat rate.

01 COAL, LIGNITE, AND PEAT↗

Preparation of polymer/LDH nanocomposite by UV-initiated photopolymerization of acrylate through photoinitiator-modified LDH precursor

Graphical abstract: This is the HR-TEM micrograph of UV cured nanocomposite at 5 wt% LDH-2959 loading for a-5 sample. The dark lines are the intersections of LDH platelets. It can be seen that samples a-5 dispersed in the polymer matrix and lost the ordered stacking-structure and show the completely exfoliation after UV curing. This can be explained by the fact that the sample a-5 only containing LDH-2959 exhibited a relative lower photopolymerization rate, which was propitious to further expand the LDH intergallery to form the exfoliated structure. Research highlights: {yields} The UV cured polymer/LDH nanocomposites were prepared through the photopolymerization initiated by the photoinitiator-modified LDH precursor, LDH-2959. {yields} The exfoliated UV cured nanocomposites were achieved in the presence of LDH-2959 only. However, the UV cured nanocomposites prepared using both LDH-2959 and Irgacure 2959 showed the intercalated structure. {yields} Compared with the pure polymer, the exfoliated polymer/LDH nanocomposite showed remarkable enhanced thermal stability and mechanical properties because of their well dispersion in the polymer matrix. -- Abstract: The exfoliated polymer/layered double hydroxide (LDH) nanocomposite by UV-initiated photopolymerization of acrylate systems through an Irgacure 2959-modified LDH precursor (LDH-2959) as a photoinitiator complex was prepared. The LDH-2959 was obtained by the esterification of 2-hydroxy-4'-(2-hydroxyethoxy)-2-methylpropiophenone (Irgacure 2959) with thioglycolic acid, following by the addition reaction with 3-(2,3-epoxypropoxy)propyltrimethoxysilane (KH-560), finally intercalation into the sodium dodecyl sulfate-modified LDH. For comparison, the intercalated polymer/LDH nanocomposite was obtained with additive Irgacure 2959 addition. From the X-ray diffraction (XRD) measurements and HR-TEM observations, the LDH lost the ordered stacking-structure and well dispersed in the polymer matrix at 5 wt% LDH-2959 loading. The glass transition temperature of UV-cured exfoliated nanocomposites increased to 64 {sup o}C from 55 {sup o}C of pure polymer without LDH addition. The tensile strength was improved from 10.1 MPa to 25.2 MPa, as well the Persoz hardness enhanced greatly, while the elongation at break remained an acceptable level.

36 MATERIALS SCIENCE↗

Evaluation of Optimal Net Load Management in Microgrids Using Hardware-in-the-Loop Simulation: Preprint

This paper presents the performance evaluation of a net load management (NLM) engine that balances load and generation in an isolated community to power a critical facility after a grid interruption event (e.g., lost a large generation unit). The NLM engine is a central dispatch control system that provides high-speed cost-optimal coordination of a set of net loads (combination of generation and deferrable loads) connected to the same electrical network. The NLM algorithm cost-optimally dispatches the grid-following inverters and deferrable loads based on the demanded power and load priorities, and the grid-forming inverters use droop control to form system voltages and share active and reactive power. A controller-hardware-in-the-loop platform is developed to evaluate the control performance of the NLM algorithm. The experimental results indicate that the NLM engine can achieve the targeted system voltage and frequency and balance load and generation to serve the critical facility.

droop control↗

Characterization of the Redesigned Extended MITL for HERMES III

Modeling and simulation of the legacy HERMES III Magnetically Insulated Transmission Line (MITL) has been performed using EMPHASIS, an unstructured time-domain electromagnetic (UTDEM) particle-in-cell (PIC) simulation software. This design when used lost roughly half of its current before the pulse reached the load. The cause of the current loss in the MITL was found to be the vacuum impedance changes along the MITL. The MITL was then redesigned to maintain constant impedance and simulated in EMPHASIS once again. Following predicting simulation results, the new MITL was then built, installed, and tested, showing minimal current loss and good agreement with simulation and theoretical results, all of which are reported here. Additionally, an analysis of experimental voltage calculation techniques using cathode and anode currents is performed and compared to simulation results.

97 MATHEMATICS AND COMPUTING↗

Study of Tribological Characteristics of Multi-pass SMAW Armox 500T Steel Joints

Study of tribological characteristics of multi-pass shielding metal arc-welded (SMAW) Armox 500T steel joints in comparison with its counterpart base metal was carried out. Series of dry sliding wear tests were carried out as a function of applied loads ranging from 30 to 120 N and sliding distances from 1000 to 6000 m at a constant sliding velocity using pin-on-disk tribometer. It was observed that specific wear rate and lost volume in SMAW joints significantly high compared to Armox 500T base metal in the range of loads and sliding distances considered in the present study. The scanning electron micrographs indicated that wear of Armox 500T base metal occurred due to micro-grooving and adhesion, on the other hand, micro-delamination was observed in SMAW joints. Microstructural investigations revealed that base metal exhibits superior tribological properties as compared to SMAW joints due to the formation of martensite lath in acicular form with coarse and fine precipitates.

36 MATERIALS SCIENCE↗