Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “loss of load cost”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

NG-CT Peaker Upgrades with Bottoming Cycle: Preliminary Analysis

The National Energy Technology Laboratory (NETL) has conducted a preliminary analysis exploring a significant opportunity to increase the nation's power grid capacity and reliability. The study focuses on retrofitting under-utilized natural gas combustion turbines (NG-CTs), often called "peaker" plants, with a bottoming cycle to capture waste heat and generate additional electricity. This analysis shows that upgrading these existing assets could add approximately 26,250 MW of new power capacity across the United States. A detailed study of the PJM Interconnection, the nation's largest grid operator, confirmed the benefits of these upgrades. Key findings for the PJM region include: - A median increase in the plants' capacity factor by 17 percentage points. - A projected 36.2% median reduction in the levelized cost of electricity (LCOE) for the upgraded plants, with nearly 88% of them expected to break even. - An average reduction in the regional wholesale price of electricity by approximately 3.0% in the year 2030. - A significant boost to grid reliability, with a 46% reduction in projected Loss of Load Hours (LOLH). These findings suggest that retrofitting peaker plants is a promising and economically viable strategy to enhance grid performance, reduce electricity costs, and meet future demand without the challenges associated with building entirely new facilities.

bottoming cycle↗

Three-dimensional turbopump flowfield analysis

A program was conducted to develop a flow prediction method applicable to rocket turbopumps. The complex nature of a flowfield in turbopumps is described and examples of flowfields are discussed to illustrate that physics based models and analytical calculation procedures based on computational fluid dynamics (CFD) are needed to develop reliable design procedures for turbopumps. A CFD code developed at NASA ARC was used as the base code. The turbulence model and boundary conditions in the base code were modified, respectively, to: (1) compute transitional flows and account for extra rates of strain, e.g., rotation; and (2) compute surface heat transfer coefficients and allow computation through multistage turbomachines. Benchmark quality data from two and three-dimensional cascades were used to verify the code. The predictive capabilities of the present CFD code were demonstrated by computing the flow through a radial impeller and a multistage axial flow turbine. Results of the program indicate that the present code operated in a two-dimensional mode is a cost effective alternative to full three-dimensional calculations, and that it permits realistic predictions of unsteady loadings and losses for multistage machines.

Sharma, O. P.↗

Improving AHU Performance by Minimizing Approach Temperature, Reducing Air Maldistribution, and Efficiently Handling Sensible and Latent Loads (Phase 1 Interim Final Technical Report)

Residential air handling units (AHUs) have stayed the same in form and efficiency for the past 30+ years, with incremental improvements made to address safety, functionality, and energy-efficiency. The purpose of this research in Phase I, Topic 9a: Next Generation Residential Air Handlers, was to improve AHU performance by minimizing heat exchanger (HX) approach temperature, reducing air maldistribution, and developing alternative system configurations which more efficiently handle sensible and latent loads. In this research Optimized Thermal Systems (OTS) developed, modeled, and evaluated multiple alternative system concepts. A dual vapor compression system separate sensible and latent cooling (SSLC) concept was studied to inform work on alternative concepts and to show best-case performance benefit. System concepts included ejector enhanced vapor compression cycles, desiccant assisted dehumidification, dual evaporator SSLC, and alternative AHU HX configurations. A dual vapor compression system showed COP improvement of 20%, however, required additional components, increased unit size, and increased cost. Two types of ejector enhanced vapor compression cycles with dual evaporators improved system COP by 9 to 11%, and reduced AHU losses by as much as 18%, with design changes limited to the AHU, no unit physical size increase, and a moderate increase to system first cost. Desiccant assisted air-conditioning required increased air flow rate resulting in higher fan power and the desiccant wheel increased sensible heat load leading to increased compressor power and reduced system COP. Dual evaporator cycles were found to degrade performance due to increased expansion losses. Optimized single slab HX designs used in place of the traditional A-coil HX led to 44–49% reduction in aluminum, 47–60% less refrigerant charge, and improved HX velocity distribution.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modeling the PV System Level Economic Impact of PV Connector Failure Modes

Photovoltaic (PV) connectors must maintain mechanical integrity for over 25 years while operating under UV exposure, elevated temperature, and mechanical loading. Connector degradation increases with electrical resistance, leading to energy losses, unplanned downtime, and higher operation and maintenance (O&M) costs and in severe cases, safety risks from overhearing or arcing. Connector related failures remain among the most frequent causes of disruption in utility-scale PV (UPV) systems, yet their lifetime economic impacts are poorly quantified. This work presents a techno-economic analysis (TEA) framework that links identified connector failure modes to system level energy losses and lifetime cost impacts using identified resistance measurements and failure rates from 6,2761 PV connectors inspected. Connector failures increase system level O&M costs, raising LCOE by roughly 5%. Downtime driven availability losses dominate economic impact. Resistance-driven I2R and IV-curve losses are secondary, but remain non-negligible. Thermal damage, bend-radius violations, and loose connections drive the majority of LCOE uplift Improving connector reliability through better installation quality, inspection, and design can meaningfully reduce lost energy, O&M costs, and LCOE.

14 SOLAR ENERGY↗

High-performance and cost-effective membrane electrode assemblies for advanced proton exchange membrane water electrolyzers: Long-term durability assessment

In this work, improved activity and durability performance of a two-cell (86 cm 2 ) proton exchange membrane water electrolyzer (PEMWE) stack is reported for the first time. Both membrane electrode assemblies (MEAs) contain one order of magnitude lower platinum group metal (PGM) loadings compared to the state-of-the-art PEMWEs and incorporate novel Pt recombination layers. The high-performance and cost-effective MEAs are fabricated by the unique reactive spray deposition technology (RSDT). This advanced methodology allows for one-step fabrication of MEAs and ensures precise control and distribution of the catalyst composition and loading. The RSDT-fabricated MEAs contain only 0.2 and 0.3 mg PGM cm –2 loading in the cathode and anode electrodes, respectively, and demonstrate excellent activity and durability for over 3000 h of operation at industrially-relevant operating conditions without showing significant loss in performance. This novel work shows that a significant cost reduction for PEMWEs is achieved while maintaining excellent durability, high catalysts activities, and low hydrogen cross-over.

Proton exchange membrane water electrolyzer↗

Understanding Line Losses and Transformer Losses in Rural Isolated Distribution Systems

Rural, isolated power systems in the mainland U.S. and in states like Alaska and Hawaii are powered by assets like diesel generators. These rural, isolated power systems also cannot operate at the higher band of medium voltage (like 69kV). They are primarily in the 12 to 14 kV range to keep the cost of the distribution investments lower. Because of this mid-band medium voltage range, the line losses and distribution transformers losses consume significant diesel consumption (almost 10 percent of the peak load). This work considers one such power system powering an isolated system and presents key findings online losses, and transformer losses. Understanding and documenting the impacts is critical for these communities operating their power systems and take actions to reduce expensive diesel consumption. In this paper, we will present one such typical grid and model it in electromagnetic transients (EMT) domain. We used the tower structure, under ground cabling installation to develop high fidelity models of lines. We also used high fidelity models of distribution transformers to present the no-load losses and full load loses. We will also present technical solutions available commercially off-the-shelf to reduce these losses and reduce diesel consumption. This work will be a primer for communities to understand the technical challenges and to understand the possible solution available to solve such challenges for rural, isolated power system operators.

blackstart↗

Modeling the Moisture Content and Dry Matter Loss in Dynamic Woody Biomass Storage Piles with Variable Extraction

The urgent need to mitigate climate change has spurred significant interest in renewable energy sources. This paper explores the storage and processing of woody biomass for biofuel production, considering the dynamic nature of biomass piles in real-world scenarios. A model has been developed to analyze moisture content changes and dry matter loss in woody biomass stored in piles prior to processing, taking into account varying extraction methods and environmental conditions. Case studies that examine the effects of different unpiling methods (FIFO, LIFO, and homogeneous) on moisture content and dry matter loss under various feedstock arrival rates and weather conditions are presented. Results indicate that unpiling methods significantly impact moisture content, with LIFO typically resulting in higher moisture content due to the utilization of fresher feedstock. Dry matter loss increases with pile size and time, emphasizing the importance of accurate modeling for assessing carbon emissions and feedstock quality. Furthermore, the model highlights the importance of process loading order and extraction methods in biomass storage, suggesting potential cost benefits associated with decreased moisture content. The difference between different extraction methods could vary the moisture content in the feedstock reaching the biofuel process by as much as 37.6%, however dry matter loss varies minimally for realistic pile changes. Overall, this research contributes to a better understanding of biomass storage dynamics and informs sustainable biofuel production practices.

Niska, Janel↗

Passive Energy-Saving Solutions for Clothes Dryers: A Modeling and Experimental Study for Improved Efficiency and Affordability

Dryers are integral appliances in modern households, yet their significant power consumption remains a critical challenge for reducing energy bills and upgrades. This work presents the outcomes of a comprehensive investigation aimed at lowering the operating energy costs of the dryer through modeling and experimental approaches. Specifically, the objectives of this research are twofold: (1) to reduce energy consumption without negatively impacting drying performance or time; and (2) to ensure affordability by developing retrofittable solutions characterized by low cost and a quick payback period. These strategies promise universal applicability to all dryer categories, encompassing both gas and electric models, by tackling core issues such as unnecessary heat loss and excess energy supply, both prevalent across dryer designs. Our methodology combines robust modeling frameworks and experimental validation to target energy efficiency improvements through three primary pathways: (1) effective heat loss management using ultralow-cost insulation materials tailored for dryer systems; (2) heat management across the drying cycle, facilitated by passive heat transfer mechanisms, and (3) optimization of heat supply to the load to ensure precise energy delivery, minimizing waste. These innovations are designed to seamlessly integrate with existing dryer configurations, providing a scalable and retrofittable solution that ensures affordability without requiring substantial redesigns or expensive components. Using these methods, the study demonstrates improvement opportunities in dryer energy consumption while maintaining the desired performance. The modeling component utilizes computational simulations to evaluate the thermal and energy performance of these innovations under varied operational conditions, providing foundational insights for experimental design. By addressing critical areas such as heat loss, energy recovery, and supply optimization, this work proposes impactful solutions for lowering the energy costs in domestic clothes dryers. The ultralow-cost, retrofittable nature of the proposed strategies ensures widespread adoption potential across diverse dryer categories, making significant strides toward affordable household energy practices.

Cheekatamarla, Praveen [ORNL] (ORCID:0000000248827↗

Comparative Investigation of System-Level Optimized Power Conversion System Architectures to Reduce LCOE for Large-Scale PV-Plus-Storage Farms

PV-plus-storage (PVS) has become a prevalent configuration for newly commissioned large-scale solar projects. However, the optimal power conversion system (PCS) architecture has not been investigated yet. This paper first validates the limited impact of inverter cost on LCOE and then explores a system-level optimized PCS architecture with extended LCOE reduction to proliferate large-scale dispatchable solar energy. Two state-of-the-art architectures including central inverters (CI), traditional 480/600 V string inverters (SI) are compared with newly proposed medium voltage string inverters (MVSI) and multiport DC transformer (MDCT). With verified layouts and single line diagrams (SLDs) of 20 MW PVS plants, the losses and costs breakdown of different architectures are extracted and the PCS related LCOEs are derived. In this analysis, all electrical bill of materials (EBOS) elements, inverters, battery storage and its associated components, are included, whose losses and costs are obtained from markets, manufacturers, and literature. Besides, the sensitivities of PCS-related LCOEs to Inverter-Loading-Ratio (ILR) are also investigated. Here, the results show that compared with CI and SI with 1.5 kV PV, 4 kV MVSI and 34 kV MDCT present an extended LCOE reduction across all ILR from 1.0 to 3.0, making them economically favorable candidates for PVS farms.

14 SOLAR ENERGY↗

Applications of thermal infrared imagery for energy conservation and environmental surveys

The survey procedures, developed during the winter and summer of 1976, employ color and color infrared aerial photography, thermal infrared imagery, and a handheld infrared imaging device. The resulting imagery was used to detect building heat losses, deteriorated insulation in built-up type building roofs, and defective underground steam lines. The handheld thermal infrared device, used in conjunction with the aerial thermal infrared imagery, provided a method for detecting and locating those roof areas that were underlain with wet insulation. In addition, the handheld infrared device was employed to conduct a survey of a U.S. Army installation's electrical distribution system under full operating loads. This survey proved to be cost effective procedure for detecting faulty electrical insulators and connections that if allowed to persist could have resulted in both safety hazards and loss in production.

Carney, J. R.↗

Study of power management technology for orbital multi-100KWe applications. Volume 2: Study results

The preliminary requirements and technology advances required for cost effective space power management systems for multi-100 kilowatt requirements were identified. System requirements were defined by establishing a baseline space platform in the 250 KE KWe range and examining typical user loads and interfaces. The most critical design parameters identified for detailed analysis include: increased distribution voltages and space plasma losses, the choice between ac and dc distribution systems, shuttle servicing effects on reliability, life cycle costs, and frequency impacts to power management system and payload systems for AC transmission. The first choice for a power management system for this kind of application and size range is a hybrid ac/dc combination with the following major features: modular design and construction-sized minimum weight/life cycle cost; high voltage transmission (100 Vac RMS); medium voltage array or = 440 Vdc); resonant inversion; transformer rotary joint; high frequency power transmission line or = 20 KHz); energy storage on array side or rotary joint; fully redundant; and 10 year life with minimal replacement and repair.

Mildice, J. W.↗

Predicted Impacts of Pt and Ionomer Distributions on Low-Pt-Loaded PEMFC Performance

Low-cost, high performance proton exchange membrane fuel cells (PEMFCs) have been difficult to develop due to limited understanding of coupled processes in the cathode catalyst layer (CCL). Low-Pt-loaded PEMFCs suffer losses beyond those predicted solely due to reduced catalyst area. Although consensus links these losses to thin ionomer films in the CCL, a precise mechanistic explanation remains elusive. In this publication, we present a physically based PEMFC model with novel structure-property relationships for thin-film Nafion, validated against PEMFC data with low Pt loading. Results suggest that flooding exacerbates kinetic limitations in low-loaded PEMFCs, shifting the Faradaic current distribution. As current density increases, protons travel further into the CCL, resulting in higher Ohmic overpotentials. We also present a parametric study of CCL design parameters. We find that graded Pt and ionomer loadings reduce Ohmic losses and flooding, but individually do not provide significant improvements. However, a dual-graded CCL (i.e., graded Pt and ionomer) is predicted to significantly improve the maximum power density and limiting current compared to uniformly loaded CCLs. This work highlights the importance of accurate transport parameters for thin-film Nafion and provides a pathway to low-cost PEMFCs via precise control of CCL microstructures.

08 HYDROGEN↗

Risk-Aware Planetary Rover Operation: Autonomous Terrain Classification and Path Planning

Identifying and avoiding terrain hazards (e.g., soft soil and pointy embedded rocks) are crucial for the safety of planetary rovers. This paper presents a newly developed groundbased Mars rover operation tool that mitigates risks from terrain by automatically identifying hazards on the terrain, evaluating their risks, and suggesting operators safe paths options that avoids potential risks while achieving specified goals. The tool will bring benefits to rover operations by reducing operation cost, by reducing cognitive load of rover operators, by preventing human errors, and most importantly, by significantly reducing the risk of the loss of rovers.

Ono, Masahiro↗

Integrated Micro‐Scale Concentrating Photovoltaics: A Scalable Path Toward High‐Efficiency, Low‐Cost Solar Power

The global energy market is seeing increases in the electricity demand of a couple of percentage points annually. The photovoltaic (PV) industry is also growing rapidly every year. One of the PV technologies is concentrator photovoltaics (CPV). CPV uses high‐efficiency multijunction solar cells and optics to concentrate sunlight, thereby significantly reducing the amount of semiconductor material needed. Yet, due to the high upfont manufacturing cost of CPV, it currently does not offer a competitive price against silicon PV. With this a new branch is introduced to the industry, micro‐CPV, which can be broadly explained as the miniaturization of the solar cells and optical components. The motivation for micro‐CPV is lowering the cost by decreasing the material volume and enabling new system architectures and high‐throughput manufacturing methods, while still maintaining high electrical efficiencies, taking advantage of a lower thermal load, shorter optical paths, lower resistive losses, and lower material volumes. Herein, a comprehensive review of the technological advances is presented, key synergies between micro‐CPV and other industries sharing similar challenges are identified, exemplified by micro‐light emitting diodes display manufacturing. New assembly process development in these industries will facilitate commercial adoption of micro‐CPV with continued miniaturization while driving down the cost.

Jost, Norman↗

Modeling and Control of Cascaded Bridgeless Multilevel Rectifier Under Unbalanced Load Conditions

The goal of this project is to model and control a novel unidirectional cascaded multilevel bridgeless rectifier as an active front end in medium and high voltage applications. This topology has many advantages over a conventional cascaded H-bridge rectifier, such as lower implementation cost, higher reliability, and greater flexibility with similar power quality.The steady-state mathematical model is used to develop a method for the voltage balancing of dc cells. Power factor analysis is discussed to achieve unity power factor using fully controlled hbridge cells. Power loss, efficiency, and cost comparison studies between the traditional cascaded H-Bridge converter and the proposed bridgeless converter demonstrate the advantages. A novel control strategy is proposed to achieve dc voltage balancing, fast and robust grid synchronization and power factor correction under unbalanced load conditions. Simulation and experimental results validate the models and control method.

Cascaded Bridgeless Rectifier, Power factor analys↗

Programmable high voltage power supply with regulation confined to the high voltage section

A high voltage power supply in a dc-dc converter configuration includes a pre-regulator which filters and regulates the dc input and drives an oscillator which applies, in turn, a low voltage ac signal to the low side of a step-up high voltage transformer. The high voltage side of the transformer drives a voltage multiplier which provides a stepped up dc voltage to an output filter. The output voltage is sensed by a feedback network which then controls a regulator. Both the input and output of the regulator are on the high voltage side, avoiding isolation problems. The regulator furnishes a portion of the drive to the voltage multiplier, avoiding having a regulator in series with the load with its attendant, relatively high power losses. This power supply is highly regulated, has low power consumption, a low parts count and may be manufactured at low cost. The power supply has a programmability feature that allows for the selection of a large range of output voltages.

Castell, Karen D.↗

Bipolar Membrane Electrodialyzers as Flexible Demand Response Resources: Co-Optimization of Cost Savings and Product Formation

Bipolar membrane electro dialyzers (BPMED) are widely used for chemical production and processing, including in the emerging ocean alkalinity enhancement (OAE) industry. In this paper, we explore the potential of BPMED devices as flexible electrochemical loads within power system operations. Using a multi-objective optimization framework, we evaluate BPMED operation across 24-hour and monthly horizons to examine how dispatch strategies respond to electricity price and grid conditions. Simulation results show that altering the relative weights of the choices in the objective function strongly shape the operating patterns, with cost-focused strategies that suppress the operation during peak prices. Furthermore, we propose alternative formulations that optimize operations to achieve both cost savings and alignment with periods of lower grid-side carbon intensity (CI), as low grid-side CI is key to maximize OAE efficiency. Additionally, a detailed sensitivity analysis highlights the importance of device properties, where low area-specific resistance (ASR) of membrane and high current efficiency (CE) are observed to jointly unlock cost-effective operation. However, even modest shunt efficiency losses are observed to erode performance and decrease system value. Importantly, the analysis demonstrates that BPMED can serve as a controllable and flexible demand response resource, shifting load to support multiple grid-side objectives, including (but not limited to) renewable integration, alleviate peak demand, and provide co-benefits for system reliability. These findings underscore BPMED’s dual role as a process technology and a grid-supporting asset, pointing to promising pathways for operational optimization of multiple objectives.

Bhattacharya, Saptarshi (ORCID:0000000308902060)↗

Sulfurized Polyacrylonitrile for High-Performance Lithium–Sulfur Batteries: In-Depth Computational Approach Revealing Multiple Sulfur’s Reduction Pathways and Hidden Li + Storage Mechanisms for Extra Discharge Capacity

Like no other sulfur host material, polyacrylonitrile-derived sulfurized carbon (SPAN) promises improved electrochemical performance for lithium–sulfur batteries, based on its compatibility with carbonate solvents and ability to prevent self-discharge and shuttle effect. However, a complete understanding of the SPAN’s lithiation mechanism is still missing because its structural features vary widely with synthesis conditions, and its electrochemical performance deviates from elemental sulfur. This study continues our research on the elucidation of the SPAN’s structural characteristics and lithiation mechanisms via computational approaches. Here, our models reproduce most experimental data regarding carbon’s graphitization level and conjugated ordering, sulfur–carbon covalent bonding, sulfur loading, and elemental composition. Our simulations emulate the discharge voltage observed in experiments for the first discharge, which reveals that sulfur follows multiple reduction pathways based on its interaction with the carbon backbone. Sulfur reduction takes place above 1.0 V vs Li/Li + mostly in the SPAN-like material, with no long-chain lithium polysulfide formation. Below 1.0 V vs Li/Li + , the backbone’s electrochemical activity occurs via multiple C–Li and N–Li interactions, mostly with edge carbon atoms and pyridinic nitrogen. Moreover, we identify Li + binding sites throughout the graphitized backbone that might lead to prohibited energy costs for Li + deintercalation, which may explain the irreversible capacity loss between the first and second discharges. This work improves understanding of lithiation mechanisms in sulfurized carbon, which is useful for rationally designing SPAN synthesis pathways tailored to increase sulfur loading and enhanced electrochemical performance.

25 ENERGY STORAGE↗