Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “local cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Ayres' bifurcated solar model

The assumptions of Ayres' model of the upper solar atmosphere are examined. It is found that the bistable character of his model is postulated - through the assumptions concerning the opacity sources and the effect of mechanical waves, which are allowed to destroy the CO molecules but not to heat the gas. The neglect of cooling by metal lines is based on their reduced local cooling rate, but it ignores the increased depth over which this cooling occurs. Thus, the bifurcated model of the upper solar atmosphere consists of two models, one cold at the temperature minimum, with a kinetic temperature of 2900 K, and the other hot, with a temperature of 4900 K.

Kalkofen, W.↗

A numerical investigation of severe thunderstorm gust fronts

A numerical model was developed to simulate the evolution and structure of severe thunderstorm gust fronts. The model is a non-hydrostatic, fine resolution, cross-sectional primitive equation model. Two-dimensional horizontal and vertical equations of motion, the continuity equation, and the thermodynamic energy equation were utilized. It was shown that two dominant factors influencing gust front configuration are surface friction and the solenoidal field coincident with the front. It is suggested that solenoidal accelerations oppose the deceleration of surface friction. After a downdraft is initiated in the model, these opposing tendencies soon reach a balance and the gust front achieves a quasi-steady configuration. Thus, the experiments indicate that surface friction does not induce a cycle of front formation and collapse. In addition, the effect of evaporative cooling in producing a vigorous downdraft was parameterized by a local cooling function. Greater cooling in the downdraft results in a more intense gust front that exhibits stronger wind maximums and greater shears. The ambient air stability was shown to be an important factor influencing the depth of the cold outflow.

Mitchell, K. E.↗

Phonon localization transition in relaxor ferroelectric PZN-5%PT

Relaxor ferroelectric behavior occurs in many disordered ferroelectric materials but is not well understood at the atomic level. Recent experiments and theoretical arguments indicate that Anderson localization of phonons instigates relaxor behavior by driving the formation of polar nanoregions (PNRs). Here, we use inelastic neutron scattering to observe phonon localization in relaxor ferroelectric PZN-5%PT (0.95[Pb(Zn 1/3 Nb 2/3 )O 3 ]–0.05PbTiO 3 ) and detect additional features of the localization process. In the lead, up to phonon localization on cooling, the local resonant modes that drive phonon localization increase in number. The increase in resonant scattering centers is attributed to a known increase in the number of locally off centered Pb atoms on cooling. The transition to phonon localization occurs when these random scattering centers increase to a concentration where the Ioffe-Regel criterion is satisfied for localizing the phonon. Finally, we also model the effects of damped mode coupling on the observed phonons and phonon localization structure.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Simple device modification simultaneously enhances indoor passive evaporative cooling power and duration

Passive evaporative cooling from a damp cloth or vessel can be used for localized cooling of perishables such as food and medicine, drinking water, and even people. Such applications have two key objectives, which are normally in tension with each other: minimizing the water consumption rate and maximizing the cooling (steady-state temperature swing between the cool cloth and the warm surroundings). Here, we present a simple device that delivers higher performance in both metrics simultaneously by adding a perforated aluminum foil sheet suspended over a stagnant air layer to thermally shield the evaporating surface while also facilitating mass transfer. Experimental results demonstrate a simultaneous 10%–25% increase in temperature swing and 2–3× reduction in water consumption rate as compared to conventional evaporative cooling. This improvement is achieved through careful modeling to optimize the coupled heat and mass transfer through the airgap (thermally insulating and vapor permeable) and perforated foil (infrared reflective and vapor permeable).

Chen, Sarah Mizuno↗

Inverse Compton Cooling in the Coronae of Simulated Black Hole Accretion Flows

We present a formulation for a local cooling function to be employed in the diffuse, hot corona region of 3D GRMHD simulations of accreting black holes. This new cooling function calculates the cooling rate due to inverse Compton scattering by considering the relevant microphysics in each cell in the corona and approximating the radiation energy density and Compton temperature there by integrating over the thermal seed photon flux from the disk surface. The method either assumes ion and electron tem- peratures are equal (1T), or calculates them separately (2T) using an instantaneous equilibrium approach predicated on the actual relevant rate equations (Coulomb and Compton). The method is shown to be consistent with a more detailed ray-tracing calculation where the bulk of the cooling occurs, but is substantially less costly to per- form. As an example, we apply these methods to a harm3d simulation of a 10M⊙, non-spinning black hole, accreting at nominally 1% the Eddington value. Both 1T and 2T approaches lead to increased radiative efficiency and a larger fraction of total cooling in the corona as compared to the original target-temperature cooling function used by harm3d, especially in the 1T case. Time-averaged post-processing reveals that the continuum spectral observations predicted from these simulations are qualitatively similar to actual X-ray binary data, especially so for the 1T approach which yields a harder power-law component (Γ = 2.25) compared to the 2T version (Γ = 2.53).

Brooks E. Kinch↗

Inverse Compton Cooling in the Coronae of Simulated Black Hole Accretion Flows

Here we present a formulation for a local cooling function to be employed in the diffuse, hot corona region of 3D GRMHD simulations of accreting black holes. This new cooling function calculates the cooling rate due to inverse Compton scattering by considering the relevant microphysics in each cell in the corona and approximating the radiation energy density and Compton temperature thereby integrating over the thermal seed photon flux from the disk surface. The method either assumes the ion and electron temperatures are equal (1T) or calculates them separately (2T) using an instantaneous equilibrium approach predicated on the actual relevant rate equations (Coulomb and Compton). The method is shown to be consistent with a more detailed ray-tracing calculation where the bulk of the cooling occurs, but is substantially less costly to perform. As an example, we apply these methods to a harm3d simulation of a 10M⊙, non-spinning black hole, accreting at nominally 1% the Eddington value. This new approach leads to radiative efficiency values sime65% above Novikov–Thorne, with a larger fraction of total cooling in the corona as compared to simulations performed using the original target-temperature cooling function. Time-averaged post-processing reveals that the continuum spectral observations predicted from these simulations are qualitatively similar to actual X-ray binary data, especially so for the 1T approach, which yields a harder power-law component (Γ = 2.25) compared to the 2T version (Γ = 2.53).

79 ASTRONOMY AND ASTROPHYSICS↗

Coupling Thermal-Hydraulics with Reactor Pressure Vessel Fracture Models

Because of the importance of maintaining the integrity of the reactor pressure vessel (RPV) in light-water reactors, significant effort has been devoted over the last several decades to understand the potential failure mechanisms, characterize how material properties evolve due to environmental conditions, and develop tools to assess the probability of fracture in aged RPVs during potential transient events. One important aspect of this problem that has not yet been fully addressed is the effects of nonuniform cooling on the RPV inner wall due to the way low-temperature water injected into the primary coolant system is distributed within the RPV during potential loss-of-coolant accident transients. Colder temperatures are expected in the regions near the inlets, causing a “cold-plume” effect. Rapid cooling of the RPV wall increases the likelihood of fracture initiation, and localized cooling due to cold-plume effects could potentially exacerbate this problem. The Grizzly code can perform a three-dimensional simulation of the RPV thermomechanical response as well as the probabilistic assessment of fracture for a population of pre-existing flaws, which is necessary to account for spatial variations in coolant temperature. This report documents a first effort to couple Grizzly RPV fracture models with computational fluid dynamics models performed using the Cardinal code, which allows for a realistic representation of the temperature distribution. This report demonstrates this coupling approach on two test cases: a simplified proof-of-concept scenario and a realistic small-break loss-of-coolant accident scenario. In both cases, the effects of the spatially varying temperature are evident; although, because the small-break loss-of-coolant accident scenario was far from challenging the RPV’s margins, it is still inconclusive how important cold-plume effects are in realistic accident scenarios. However, this effort represents an important step toward performing realistic analyses to determine to what extent spatially nonuniform cooling might affect RPV integrity under more aggressive accident scenarios.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

The X-ray Spectrum of the North Polar Spur

An analysis is presented of the soft X-ray background spectrum measured by the EPIC MOS cameras on XMM-Newton in three observations targeted on the North Polar Spur (NPS). Three distinct Galactic plasma components are identified, a cool Local Hot Bubble (LHB) component, T(sub lo) approx. 0.1 keV, a cool Galactic Halo component at a similar temperature and a hotter component, T(sub hi) approx. 0.26 keV, associated with the NPS itself. Using the new data in combination with the Rosat All-Sky Survey count rates measured in the 0.1-0.4 keV band, we estimate the emission measure of the LHB material to be 0.0040-0.0052 cm(exp -6) pc, which implies an electron density of 0.008-0.011 cm(exp -3) and pressure of approx. 22000 cm(exp -3) K. The halo and NPS components lie behind at least 50% of the line-of-sight cold gas for which the total Galactic column density is in the range (2 - 8) x 10(exp 20) cm(exp -2). Modelling the X-ray emitting superbubble as a sphere at distance 210 pc, radius 140 pc and center l(sub II) = 352 deg, b(sub II) = 15 deg, the implied electron density in the NPS is approx. 0.03 cm(exp -3) with pressure approx. 150000 cm(exp -3) K. The observed spectral line complexes from OVII, OVIII, FeXVII, NeIX, NeX and MgXI provide constraints on the composition of the plasma. The hot component in the NPS is depleted in oxygen, neon and, to some extent, magnesium and iron. Assuming the effective line of sight across the halo emission is 1 kpc, the electron density in the halo is 0.007-0.011 cm(exp -3) and the pressure is approx. 16500 cm(exp -3) K, conditions very similar to those in the LHB.

Willingale, Richard↗

Modeling of Crucial Process Parameters for the Continuous Improvement of Special Steels at the Stomana Plant

In this study, a heat transfer model that takes under consideration the micro-segregation phenomena and has been extensively deployed for solidification studies concerning the plant casters is also applied to show the casting speed and superheat effects upon internal soundness. Τhe solidification path of C45R, 42CrMo4, S355 grades was simulated using Thermocalc{sup ®} and DICTRA software in order to examine the phases formed in crucial process temperature windows for the casting. Coupled Heat Transfer/Simple Micro-Segregation Model software has been deployed to simulate the effect of cooling rate on solidus temperature, and solid fraction during solidification. The solidus temperature results computed by the HT/SM and DICTRA were found to be in good agreement. However, the differences in the predicted solidification fractions may derive from the fact that DICTRA uses an average cooling rate whereas the heat transfer SM model takes into account also the local cooling rates in the solidification progress.

36 MATERIALS SCIENCE↗

SIMULATING THE COOLING FLOW OF COOL-CORE CLUSTERS

We carry out high-resolution adaptive mesh refinement simulations of a cool core cluster, resolving the flow from Mpc scales down to pc scales. We do not (yet) include any active galactic nucleus (AGN) heating, focusing instead on cooling in order to understand how gas reaches the supermassive black hole at the center of the cluster. We find that, as the gas cools, the cluster develops a very flat temperature profile, undergoing a cooling catastrophe only in the central 10-100 pc of the cluster. Outside of this region, the flow is smooth, with no local cooling instabilities, and naturally produces very little low-temperature gas (below a few keV), in agreement with observations. The gas cooling in the center of the cluster rapidly forms a thin accretion disk. The amount of cold gas produced at the very center grows rapidly until a reasonable estimate of the resulting AGN heating rate (assuming even a moderate accretion efficiency) would overwhelm cooling. We argue that this naturally produces a thermostat which links the cooling of gas out to 100 kpc with the cold gas accretion in the central 100 pc, potentially closing the loop between cooling and heating. Isotropic heat conduction does not affect the result significantly, but we show that including the potential well of the brightest cluster galaxy is necessary to obtain the correct result. Also, we found that the outcome is sensitive to resolution, requiring very high mass resolution to correctly reproduce the small transition radius.

79 ASTRONOMY AND ASTROPHYSICS↗

Steady state cooling flow models with gas loss for normal elliptical galaxies

A grid of cooling flow models for the hot gas in normal elliptical galaxies is calculated, including the loss of gas due to inhomogeneous cooling. The loss process is modeled as a distributed sink for the gas with the rate of loss being proportional to the local cooling rate. The cooling flow models with gas loss have smaller sonic radii, smaller inflow rates in their central regions, lower densities, and higher temperatures than homogeneous models. The reduction in the amount of hot gas flowing into the center of the models brings the models into much better agreement with the observed X-ray surface brightness profiles of elliptical galaxies. However, there is a large dispersion in the observed X-ray luminosities of ellipticals, and this cannot be explained by variations in the efficiency of gas loss. The gas-loss models have X-ray surface brightness profiles which are much less centrally peaked than the no-gas-loss models.

Sarazin, Craig L.↗

Advanced Liquid Cooling for a Traction Drive Inverter Using Jet Impingement and Microfinned Enhanced Surfaces: Preprint

Jet impingement on plain and micro-finned enhanced surfaces was compared to a traditional channel flow configuration. The jets provide localized cooling to areas heated by the insulated-gate bipolar transistor and diode devices. Enhanced microfinned surfaces increase surface area and thermal performance. Using lighter materials and designing the fluid path to manage pressure losses increases overall performance while reducing weight, volume, and cost. Powering four diodes in the center power module of the inverter and computational fluid dynamics (CFD) modeling was used to characterize the baseline as well as jet-impingement-based heat exchangers. CFD modeling showed the thermal performance improvements should hold for a fully powered inverter. Increased thermal performance was observed for the jet-impingement configurations when tested at full inverter power (40 to 100 kW output power) on a dynamometer. The reliability of the jets and enhanced surfaces over time was also investigated. Experimentally, the junction-to- coolant thermal resistance was reduced by up to 12.5% for jet impingement on enhanced surfaces s compared to the baseline channel flow configuration. Base plate-to-coolant (convective) resistance was reduced by up to 37.0% for the jet-based configuration compared to the baseline, suggesting that while improvements to the cooling side reduce overall resistance, reducing the passive stack resistance may contribute to lowering overall junction-to-coolant resistance. Full inverter power testing showed reduced thermal resistance from the middle of the module baseplate to coolant of up to 16.5%. Between the improvement in thermal performance and pumping power, the coefficient of performance improved by up to 13% for the jet-based configuration.

30 DIRECT ENERGY CONVERSION↗

Fighting Fire with Fire: Superlattice Cooling of Silicon Hotspots to Reduce Global Cooling Requirements

The running costs of data centers are dominated by the need to dissipate heat generated by thousands of server machines. Higher temperatures are undesirable as they lead to premature silicon wear-out; in fact, mean time to failure has been shown to decrease exponentially with temperature (Black's law). Although other server components also generate heat, microprocessors still dominate in most server configurations and are also the most vulnerable to wearout as the feature sizes shrink. Even as processor complexity and technology scaling have increased the average energy density inside a processor to maximally tolerable levels, modern microprocessors make extensive use of hardware structures such as the load-store queue and other CAM-based units, and the peak temperatures on chip can be much worse than even the average temperature of the chip. In recent studies, it has been shown that hot-spots inside a processor can generate {approx} 800W/cm{sup 2} heat flux whereas the average heat flux is only 10-50W/cm{sup 2}, and due to this disparity in heat generation, the temperature in hot spots may be up to 30 C more than average chip temperature. The key problem processor hot-spots create is that in order to prevent some critical hardware structures from wearing out faster, the air conditioners in a data center have to be provisioned for worst case requirements. Worse yet, air conditioner efficiencies decrease exponentially as the desired ambient temperature decreases relative to the air outside. As a result, the global cooling costs in data centers, which nearly equals the IT equipment power consumption, are directly correlated with the maximum hot spot temperatures of processors, and there is a distinct requirement for a cooling technique to mitigate hot-spots selectively so that the global air conditioners can operate at higher, more efficient, temperatures. We observe that localized cooling via superlattice microrefrigeration presents exactly this opportunity whereby hot-spots can be cooled selectively and allow global coolers to operate at much more efficient temperatures. Recent advances in processor cooling technologies have demonstrated that thermoelectric coolers (TEC), which use a Peltier effect to form heat pumps, can be used to reduce the temperature of hot spots. By applying a thermoelectric cooler between the heat spreader and the processor die and applying current selectively at the hot spots, heat from the hot-spots can be spread much more efficiently. The ability to implement such thermoelectric coolers on a real silicon device has been demonstrated recently, albeit for small prototype chips. The key question then, that needs to be answered before such thermoelectric coolers can be integrated in commodity server processors, is 'What is the potential for superlattice microrefrigeration to reduce global cooling costs in data centers?'. In order to answer this question, we present a comprehensive analysis of the impact of thermoelectric coolers on global cooling costs. Our thermal analysis covers all aspects of cooling a server in a data center, and integrates on-chip dynamic and leakage power sources with a detailed heat diffusion model of a processor (that models the silicon to the thermoelectric cooler to the heat spreader and the heat sink) and finally the computer room air conditioner (CRAC) efficiency, as shown in Figure 1. In Section II, we present the components of the system model.

99 GENERAL AND MISCELLANEOUS↗

A Century of Reforestation Reduced Anthropogenic Warming in the Eastern United States

Abstract Restoring and preserving the world's forests are promising natural pathways to mitigate some aspects of climate change. In addition to regulating atmospheric carbon dioxide concentrations, forests modify surface and near‐surface air temperatures through biophysical processes. In the eastern United States (EUS), widespread reforestation during the 20th century coincided with an anomalous lack of warming, raising questions about reforestation's contribution to local cooling and climate mitigation. Using new cross‐scale approaches and multiple independent sources of data, we uncovered links between reforestation and the response of both surface and air temperature in the EUS. Ground‐ and satellite‐based observations showed that EUS forests cool the land surface by 1–2°C annually compared to nearby grasslands and croplands, with the strongest cooling effect during midday in the growing season, when cooling is 2–5°C. Young forests (20–40 years) have the strongest cooling effect on surface temperature. Surface cooling extends to the near‐surface air, with forests reducing midday air temperature by up to 1°C compared to nearby non‐forests. Analyses of historical land cover and air temperature trends showed that the cooling benefits of reforestation extend across the landscape. Locations surrounded by reforestation were up to 1°C cooler than neighboring locations that did not undergo land cover change, and areas dominated by regrowing forests were associated with cooling temperature trends in much of the EUS. Our work indicates reforestation contributed to the historically slow pace of warming in the EUS, underscoring reforestation's potential as a local climate adaptation strategy in temperate regions.

Environmental Sciences & Ecology↗

THE BURST MODE OF ACCRETION AND DISK FRAGMENTATION IN THE EARLY EMBEDDED STAGES OF STAR FORMATION

We revisit our original papers on the burst mode of accretion by incorporating a detailed energy balance equation into a thin-disk model for the formation and evolution of circumstellar disks around low-mass protostars. Our model includes the effect of radiative cooling, viscous and shock heating, and heating due to stellar and background irradiation. Following the collapse from the prestellar phase allows us to model the early embedded phase of disk formation and evolution. During this time, the disk is susceptible to fragmentation, depending upon the properties of the initial prestellar core. Globally, we find that higher initial core angular momentum and mass content favors more fragmentation, but higher levels of background radiation can moderate the tendency to fragment. A higher rate of mass infall onto the disk than that onto the star is a necessary but not a sufficient condition for disk fragmentation. More locally, both the Toomre Q-parameter needs to be below a critical value and the local cooling time needs to be shorter than a few times the local dynamical time. Fragments that form during the early embedded phase tend to be driven into the inner disk regions and likely trigger mass accretion and luminosity bursts that are similar in magnitude to FU-Orionis-type or EX-Lupi-like events. Disk accretion is shown to be an intrinsically variable process, thanks to disk fragmentation, nonaxisymmetric structure, and the effect of gravitational torques. The additional effect of a generic {alpha}-type viscosity acts to reduce burst frequency and accretion variability, and is likely to not be viable for values of {alpha} significantly greater than 0.01.

79 ASTRONOMY AND ASTROPHYSICS↗

The effect of snow cover on the climate

Large-scale snow cover anomalies are thought to cause significant changes in the diabatic heating of the earth's surface in such a way as to produce substantial local cooling in the surface temperatures. This theory was tested using the GISS 3D GCM (General Circulation Model). The results of the GCM experiment showed that snow cover caused only a short term local decrease in the surface temperature. In the surface energy budget, reduction in absorbed shortwave radiation and the increased latent heat sink of melting snow contributed to lower temperatures. However, all the remaining heating terms contribute to increasing the net heating over a snow covered surface. The results emphasize the negative feedback which limits the impact of snow cover anomalies over longer time scales.

Cohen, Judah↗

Mergers, cooling flows, and evaporation

Mergers (the capture of cold gas, especially) can have a profound influence on the hot coronal gas of early-type galaxies and clusters, potentially inducing symptoms hitherto attributed to a cooling flow, if thermal conduction is operative in the coronal plasma. Heat can be conducted from the hot phase into the cold phase, simultaneously ionizing the cold gas to make optical filaments, while locally cooling the coronal gas to mimic a cooling-flow. If there is heat conduction, though, there is no standard cooling-flow since radiative losses are balanced by conduction and not mass deposition. Amongst the strongest observational support for the existence of cooling-flows is the presence of intermediate temperature gas with x-ray emission-line strengths in agreement with cooling-flow models. Here, x-ray line strengths are calculated for this alternative model, in which mergers are responsible for the observed optical and x-ray properties. Since gas around 10(exp 4) K is thermally stable, the cold cloud need not necessarily evaporate and hydrostatic solutions exist. Good agreement with the x-ray data is obtained. The relative strengths of intermediate temperature x-ray emission lines are in significantly better agreement with a simple conduction model than with published cooling-flow models. The good agreement of the conduction model with optical, infrared and x-ray data indicates that significantly more theoretical effort into this type of solution would be profitable.

Sparks, W. B.↗

Precipitation Behaviors of TiN Inclusion in GCr15 Bearing Steel Billet

There are many types of non-metallic TiN-based inclusions observed in GCr15 bearing steel, including single-particle TiN, multi-particle polymerized TiN, and complex inclusions like TiN-MnS, TiN-MgO-MgAl{sub 2}O{sub 4} (TiN-MgO-MA), and TiN-MgAl{sub 2}O{sub 4}-MnS (TiN-MA-MnS). Thermodynamic calculations suggest that single-particle TiN precipitates dominate the mushy zone of GCr15 bearing steel. Kinetic calculations regarding TiN growth suggest that the final size of the single-particle TiN ranges between 1 and 6 μm in the initial concentration range of [pct Ti] = 0.0060 to 0.0079 and [pct N] = 0.0049 to 0.0070, at 1620 to 1640 K and a local cooling rate of 0.5 to 10 K/s. The multi-particle polymerized TiN are formed by single TiN particles in three stages: single-particle TiN inclusions approach each other drawn by the cavity bridge force (CBF), local active angles consolidate, and neck region sintering occurs. Based on the thermodynamic calculations of TiN, MnS, and MgO precipitation, the formation behaviors of complex inclusions of TiN-MnS, TiN-MgO-MA, and TiN-MA-MnS were investigated.

36 MATERIALS SCIENCE↗