Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “load response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Utilizing grid–supportive load response to shape resilient frequency control of the power grid

The increasing penetration of renewable energy sources and the retirement of conventional generation units have decreased system inertia, making power systems more vulnerable to resilience and stability issues. To address this problem, this paper proposes a novel approach using grid-supportive loads (GSLs) to provide a fast and concise primary frequency response and a deep deterministic policy gradient agent-based secondary controller to restore the system frequency to the nominal value. The proposed method is evaluated on the single-area and multi-area test systems. The simulation results demonstrate that using GSLs enhances the power system's stability and resilience. Compared to conventional controllers, the frequency nadir is improved with GSLs. Additionally, the proposed method effectively enhances resilience even with high penetration. These findings indicate that the proposed approach can improve the resilience and stability of power systems and provide a promising solution for future power systems. The results of this study underscore the importance of utilizing innovative approaches to enhance the stability and resilience of power systems in the context of high penetration of renewable energy sources and the retirement of conventional generation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Loads Response That is Due to Wake Steering on a Pair of Utility-Scale Wind Turbines

The goal of this report is to present the resulting turbine loads of a full-scale wind turbine wake steering field campaign. In this experiment, wake steering controls were applied to an upwind turbine (T2) and the downwind turbine (T3) was instrumented to measure mechanical loads. The test subjects (T2 & T3) were GE 1.5SLE CWE turbines located on a wind farm with a prevailing wind direction coming from the northwest. The data collection strategy involved toggling the wake steering controls of T2 between on and off. This resulted in two databases (baseline and wake steered) with similar turbulence intensities. Valid data was extracted and processed. The analysis involved scaling data to engineering units, applying coordinate transformations where applicable, calculating 10-minutes statistics, and calculating damage equivalent loads (DELs) to assess fatigue. Figures are shown as statistics and DELs binned by wind speed with supplemental scatter plots provided in the appendices. Results between the baseline and wake steered databases were compared. Overall, the binned statistics showed minimal differences in loading between the two cases. However, the DELs of the wake steered case were observed to be consistently smaller than the baseline for most of the turbine components. A potential for future work was recognized based on the findings of this report. Some areas of further study include an analysis for more granular loads sensitivity to different yaw offset angles and rotor wake overlap, an in-depth comparison of loads between the upwind and downwind turbines, and further fatigue analysis to quantify differences observed in this experiment.

17 WIND ENERGY↗

Load-Responsive Motor Controller

New circuit controls voltage applied to a three-phase induction motor in response to magnitude of current, so as to reduce power consumption when the motor is idling or operating at less than full load. Control circuit decreases rms applied voltage to match decreases in motor load over entire torque range. This considerably decreases power consumption in motors operating at a fraction of their rated torques.

Edge, T. M.↗

To what extent is mass loading responsible for the Venus bowshock precursor?

Significant ion and electron flux enhancements immediately upstream of the Venus bow shock were observed by the Electron Temperature Probe on the Pioneer Venus Orbiter. It is shown that mass loading of the solar wind by oxygen ions accounts for only about 10 percent of the observed effect.

Fontheim, Ernest G.↗

Management of Risk and Uncertainty Through Optimized Co-Operation of Transmission Systems and Microgrids with Responsive Loads (Final Report)

The evolution of the power system to the reliable, efficient and sustainable system of the future will involve development of both demand- and supply-side technology and operations. Ambitious national and state-level goals around the decarbonization of electricity relies on the integration of very high levels of renewable resources, most of which are variable and intermittent. The use of demand response is an ideal approach to counterbalance the intermittency of renewable generation and brings the consumer into the spotlight. Until recently, very little research had been conducted on the co-optimization of these two systems due to computational limitations. However, advances in computational capabilities, and the judicious use of decomposition methods and innovative approximation methods for high-dimension dynamic programming made this goal a viable objective for this project, leading to a fundamental shift in the ability to integrate and fully utilize demand-side resources. To this end, the modeling framework developed introduces a novel co-optimization framework, to include the operations of both the transmission and distribution systems (or microgrids) in operational decision making. This framework was used to analyze renewable and distributed generation along with responsive demand and to compare the capability of co-optimized systems to perform with higher levels of variable renewables. Results show that the use of a bi-level optimization approach is an appropriate structure, capable of co-optimizing a transmission system with multiple distribution systems and microgrids. While increasing the number of connected systems provides increasing flexibility for renewables integration this can also the economic benefits to the low-voltage subsystems with each additional system connected. Comparison of a traditional single-level decision structure with the co-optimization approach illustrates a reduction in overall system cost under co-optimization, while specific cost allocations to transmission and distribution systems are changed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Management of Risk and Uncertainty Through Optimized Co-Operation of Transmission Systems and Microgrids With Responsive Loads (Final Report)

The evolution of the power system to the reliable, efficient and sustainable system of the future will involve development of both demand- and supply-side technology and operations. Ambitious national and state-level goals around the decarbonization of electricity relies on the integration of very high levels of renewable resources, most of which are variable and intermittent. The use of demand response is an ideal approach to counterbalance the intermittency of renewable generation and brings the consumer into the spotlight. Though individual consumers are interconnected at the low-voltage distribution system, these resources are typically modeled as variables at the transmission network level. Demand-side participation cannot be leveraged effectively without explicitly including the distribution system dynamics in the optimization-based wholesale market operations. This project grew from a vision for co-optimized interaction of distribution systems, or microgrids, with the high-voltage transmission system. In this framework, microgrids encompass consumers, distributed renewables and storage. The energy management system of the lower voltage system (distribution or microgrid) can also sell (buy) excess (necessary) energy from the transmission system. Until recently, very little research had been conducted on the co-optimization of these two systems due to computational limitations. However, advances in computational capabilities, and the judicious use of decomposition methods and innovative approximation methods for high-dimension dynamic programming made this goal a viable objective for this project, leading to a fundamental shift in the ability to integrate and fully utilize demand-side resources. To this end, the modeling framework developed introduces a novel co-optimization framework, to include the operations of both the transmission and distribution systems (or microgrids) in operational decision making. This framework was used to analyze renewable and distributed generation along with responsive demand and to compare the capability of co-optimized systems to perform with higher levels of variable renewables. An ideal microgrid is defined as an electric entity capable of operating in both interconnected (with the high-voltage grid) and islanded mode. As such, the microgrid should incorporate generating units (traditional units and intermittent) and if needed, exchange power with the high-voltage grid. The interplay between the microgrid and high-voltage grid motivated the development of the co-optimization approach to ensure efficient performance of the interconnected network. Results show that the use of a bi-level optimization approach is an appropriate structure, capable of co-optimizing a transmission system with multiple distribution systems and microgrids. While increasing the number of connected systems provides increasing flexibility for renewables integration this can also the economic benefits to the low-voltage subsystems with each additional system connected. Comparison of a traditional single-level decision structure with the co-optimization approach illustrates a reduction in overall system cost under co-optimization, while specific cost allocations to transmission and distribution systems are changed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Load response of a floating wind turbine to turbulent atmospheric flow

The two turbulence-generation models [Kaimal Spectrum Exponential Coherence (KSEC) and Mann] specified in the international standard for wind turbine design assume neutral atmospheric conditions and are based on statistical and spectral methods. Mainly due to the lack of physics, the flow fields simulated with these models ultimately differ in their underlying structure, especially in terms of the spatial coherence of longitudinal velocity perturbations. While this may not be critical for smaller wind turbine rotors, it becomes important when rotor sizes increase. Furthermore, it might be especially important in the context of floating technologies as they are more sensitive to large turbulent coherent structures. Previous work found that these differences between KSEC and Mann can propagate to loads predictions and thereby affect the design space of the entire wind turbine system. It is therefore crucial to determine in which ways these two models are underperforming. Up until now, validation of these models had only been done in the vertical direction because it is extremely difficult to obtain atmospheric turbulence measurements separated laterally, and sampled at heights relevant to wind energy. In this work, we address the lack of measurements by using high-fidelity, high-resolution simulation data as a reference. We perform hour-long, large-eddy simulations of turbulent velocity fields that are stability-dependent and contain three-dimensional coherent structures. These flow fields are then used to investigate which stochastic model is a better predictor of loads on a realistic spar-system floating offshore wind turbine, and to quantify how the assumption of neutral stratification propagates to short-term load estimates. Both stochastic turbulence models are found to overpredict fatigue loading in high-wind scenarios (in some cases, by more than 25%) and underpredict it when the wind speed is low (by as much as 20%). The KSEC model matches the high-fidelity flow fields more closely than Mann at high wind speeds, and the opposite is true at low wind speeds. Finally, turbine loading is found to be sensitive to atmospheric stability even when the turbulence intensity remains fairly constant. This sensitivity is most pronounced at low wind speeds, when fatigue load estimates on the spar system can differ by 40%.

17 WIND ENERGY↗

Frequency Responsive Load

The Energy Commission is currently soliciting ideas and stakeholder input for the 2018 – 2020 EPIC Triennial Investment Plan. For those that would like to submit an idea for consideration in the 2018-2020 EPIC Triennial Plan, we ask that you complete the form below. Submittals are due by 5:00 p.m. on February 10, 2017.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

The atmospheric load response of the ocean determined using Geosat altimeter data

Sea-surface heights derived from the Geosat altimeter data for the November 1986 - November 1987 period are compared with the Fleet Numerical Oceanographic Center and the NMC sea-level atmospheric pressure fields, to verify the open ocean inverted barometer (IB) response. It is shown that fits along the satellite track consistently yield results that are only 60-70 percent of the IB results. Fits at fixed geographic locations show a clear dependence of the absolute value of the regression coefficient with latitude: a steady decrease from 70 deg to about 20 deg, and then a sudden increase again nearer to the equator, with similar results obtained for the Northern and the Southern Hemispheres. The sign of the departure from IB is found to be consistent with the expected effects of errors in the pressure fields and with wind-induced changes in sea level that are correlated with pressure fluctuations.

Vandam, Tonie M.↗

Aggregated Modeling and Control of Air Conditioning Loads for Demand Response

Demand response is playing an increasingly important role in the efficient and reliable operation of the electric grid. Modeling the dynamic behavior of a large population of responsive loads is especially important to evaluate the effectiveness of various demand response strategies. In this paper, a highly-accurate aggregated model is developed for a population of air conditioning loads. The model effectively includes statistical information of the population, systematically deals with load heterogeneity, and accounts for second-order dynamics necessary to accurately capture the transient dynamics in the collective response. Based on the model, a novel aggregated control strategy is designed for the load population under realistic conditions. The proposed controller is fully responsive and achieves the control objective without sacrificing end-use performance. The proposed aggregated modeling and control strategies are validated through realistic simulations using GridLAB-D. Extensive simulation results indicate that the proposed approach can effectively manage a large number of air conditioning systems to provide various demand response services, such as frequency regulation and peak load reduction.

Zhang, Wei↗

Predicting the Response of Electricity Load to Climate Change

Our purpose is to develop a methodology to quantify the impact of climate change on electric loads in the United States. We perform simple linear regression, assisted by geospatial smoothing, on paired temperature and load time-series to estimate the heating- and coolinginduced sensitivity to temperature across 300 transmission zones and 16 seasonal and diurnal time periods. The estimated load sensitivities can be coupled with climate scenarios to quantify the potential impact of climate change on load, with a primary application being long-term electricity scenarios. The method allows regional and seasonal differences in climate and load response to be reflected in the electricity scenarios. While the immediate product of this analysis was designed to mesh with the spatial and temporal resolution of a specific electricity model to enable climate change scenarios and analysis with that model, we also propose that the process could be applied for other models and purposes.

54 ENVIRONMENTAL SCIENCES↗