At least 37 records · Page 2

Electrified autonomous freight benefit analysis on fleet, infrastructure and grid leveraging Grid-Electrified Mobility (GEM) model

Fast-growing freight activities over the decades have become one of the major contributors to air pollution, leading to many efforts in freight decarbonization and electrification. However, the development of freight electrification is slow due to technological uncertainty, slow charging, high capital cost, etc. This paper analyzes the potential impact and benefit of heavy-duty vehicle (HDV) electrification and automation on fleet cost, infrastructure cost, the electricity grid, and environmental outcomes. In this work, we extended the vehicle electrification benefit analysis tool: Grid-Electrified Mobility (GEM) model, which had primarily been used to study light-duty passenger vehicles (LDVs), to analyze heavy-duty vehicle electrification. The extended model is derived for freight transportation electrification, and different freight electrification and automation adoption scenarios were analyzed. We find that the increased penetration of automated electric freight fleets within other types of electrified freight fleets from 1% to 99% will result in an overall cost reduction of 18.2%, fleet size reduction of 20.4%, and lower peak load reduction of 14.3%.

33 ADVANCED PROPULSION SYSTEMS↗

Robust multi‐loop control of a floating wind turbine

Abstract A principal challenge facing the control of floating offshore wind turbines (FOWTs) is the problem of instability, or “negative damping,” when using blade pitch feedback to control generator speed. This closed‐loop instability can be attributed to non‐minimum phase zeros in the transfer function from blade pitch to generator speed. Standard approaches to improving stability and performance include robust tuning of control gains and introducing multiple feedback loops to respond to platform motion. Combining these approaches is nontrivial because multiple control loops complicate the impact of coupling in the system dynamics. The single‐loop approach to analyzing stability robustness neglects inter‐loop coupling, while a simplistic multi‐loop approach is highly sensitive to dimensional scaling and overestimates the robustness of the single‐loop controller. This work proposes a sensitivity representation that separates some of the natural FOWT dynamic coupling into a parallel feedback loop in the sensitivity function loop to address both of these concerns. The modified robustness measure is used with a simplified linear FOWT model to optimize scheduled multi‐loop control parameters in an automated tuning procedure. This controller is implemented for the 10‐MW Ultraflexible Smart FLoating Offshore Wind Turbine (USFLOWT) and compared against conventional single‐ and multi‐loop controllers tuned using frequency‐domain analysis and high‐fidelity OpenFAST simulations. The multi‐loop robust controller shows the highest overall performance in generator speed regulation and tower load reduction, though consideration of power quality, actuator usage, and other structural loading leads to additional trade‐offs.

Stockhouse, David↗

Collaborative Decision Approach for Electricity Pricing-demand Response Stackelberg Game

Demand response programs are considered as a valuable resource in smart grids that provide several advantages of load shifting, peak load reduction, mediating intermittency of renewable energy integration, etc. Flexible price-based incentives have been recognized as a critical strategy in motivating and compensating consumers' load adjustment actions for successful implementation of demand response. Game theoretical approaches, especially Stackelberg games are popularly adopted to model the relationship between electricity price and customers' demand response and solved by the classical centralized backward induction (BI) method. However, the BI method generally requires convexity of the follower's model for necessary optimality conditions, and the computational time of any centralized approach increases sharply with larger problem instances. In this paper, the Stackelberg game of electricity pricing-demand response between a distribution system operator (DSO) and load aggregators (LAs) is decomposed based on a collaborative optimization (CO) framework, where each LA is treated as a discipline with its own domain constraints (e.g. building temperature control), while the DSO at the system level tries to reduce the solution discrepancy and guide the searching towards optimality. Several groups of comparison experiments have demonstrated the effectiveness of the proposed collaborative decision approach in solving the demand response game.

Chen, Yang↗

Model-Free Building Temperature Control and Power Allocation Under Measurement Time Delays

Taking a step towards a greener planet has created an increased need for a higher integration of renewable energy resources into the electric grid. Nonetheless, the intermittency and uncertainty associated with renewable generation have slowed down this integration. Demand response (DR) has been recently adopted to address this challenge by utilizing demand side flexibility and enabling the participation of many grid-interactive efficient buildings (GEBs). However, existing DR methods require significant modeling and/or training efforts and are computationally expensive. To address the aforementioned issues, we propose a model-free control (MFC)-based strategy that is robust to the time delays in the temperature measurements of the thermostatically controlled loads (TCLs). It assigns to each GEB a local controller to maintain the TCLs’ temperatures within desired comfort levels, while the load aggregator (LA) allocates the assigned reference power provided by the distribution system operator (DSO) to support a specific grid service, such as demand peak reduction, load shifting, balancing supply and demand, and consuming the solar photovoltaic power locally. We investigate the effects of such loss of information on the local control action as well as on meeting the power allocation constraint. We conclude that, for an appropriate choice of design parameters, the proposed MFC controller is satisfactorily robust to measurement time delays.

Telsang, Bhagyashri↗

Assessing the impacts of wakes on floating wind farms with shared anchors

This paper examines wake effects for floating wind farms with shared anchors. Three 20-turbine farms are examined: a grid-formation baseline with no shared anchors, a farm based on 3-line anchors, and a farm based on 6-line anchors, governed by a wind turbine spacing of 8 rotor diameters. The IEA 15 MW reference turbine on the UMaine semisubmersible platform was used with a taut mooring system in deep- water depths representative of U.S. west coast lease areas. A steady-state wake model showed that, when evaluating a sweep of wind headings, the baseline design had the lowest wake losses, with a value of 11.7 %, followed by the 6-line at 12.9% and the 3-line at 13.8%. Dynamic simulations were run in FAST.Farm to analyse the effects of wakes on mean anchor loads for wind headings that showed significant wake losses. The baseline farm showed the largest anchor load reductions due to wake effects (up to 16%), followed by the 3-line farm (up to 8%), and the 6-line farm, which showed relatively consistent load magnitudes on the 6-line anchors across all headings.

17 WIND ENERGY↗

Hanover LED Streetlight Conversion

On May 8, 2017, Hanover residents voted overwhelmingly to transition to 100% renewable electricity by 2030 and heating, cooling and transportation by 2050. In so doing, we became the first municipality in the country to make this commitment by popular vote. To accomplish these goal town leaders developed a plan to address first transitioning municipal energy uses to renewable forms of energy, through on-site generation of the municipal electrical load, load reduction through energy efficiency improvements to town facilities and infrastructure. Significant progress has been accomplished in the generation of energy with 90%+ of the 2024 municipal load being offset by generation and through various energy efficiency projects. The utility owned street lighting was identified as a large energy consumer of 165 MWh annually (7% of the annual municipal load) due to old inefficient high-pressure sodium and mercury vapor streetlights with no ability to reduce wattage during periods with low lighting needs. The Hanover LED Streetlight Replacement Project replaced utility owned streetlights with town owned controllable (dimmable and trimmable) LED lights that can be adjusted by location and time of night. Coupled with ownership of the streetlights transfer to the town, the town’s share of the project pay back is 11 months and for the complete project including federal share the payback is approximately 3 years. With the completion of lighting upgrade, the annual streetlighting energy load has dropped by 60% to 67 MWh in the first year of operation (7/1/24 - 6/30/25). This amounts to an approximate $90,000 annual savings or a local 1% tax rate impact. Additionally, over 200,000 pounds of CO2 will be saved annually.

99 GENERAL AND MISCELLANEOUS↗

Review of wake management techniques for wind turbines

Summary The progression of wind turbine technology has led to wind turbines being incredibly optimized machines often approaching their theoretical maximum production capabilities. When placed together in arrays to make wind farms, however, they are subject to wake interference that greatly reduces downstream turbines' power production, increases structural loading and maintenance, reduces their lifetimes, and ultimately increases the levelized cost of energy. Development of techniques to manage wakes and operate larger and larger arrays of turbines more efficiently is now a crucial field of research. Herein, four wake management techniques in various states of development are reviewed. These include axial induction control, wake steering, the latter two combined, and active wake control. Each of these is reviewed in terms of its control strategies and use for power maximization, load reduction, and ancillary services. By evaluating existing research, several directions for future research are suggested.

17 WIND ENERGY↗

Scheduling and Control of Flexible Building Loads for Grid Services Based on a Virtual Battery Model

This paper presents a framework for modeling, scheduling, and controlling residential thermostatically controlled loads (TCLs) to provide multiple grid services, such as energy shifting, peak load reduction, and ancillary services. A modeling method is proposed to characterize the aggregate flexibility from heterogeneous TCLs using a battery-equivalent model. Based on the flexibility model, a multi-period optimal scheduling formulation is developed to best utilize the flexibility from building loads and maximize total benefits from stacked value streams. An algorithm is proposed to control individual TCLs to follow the desired power consumption in real-time. The proposed methods are illustrated and validated through simulations.

Wu, Di↗

Impact of Porous Transport Layer Morphology on the Performance of Proton Exchange Membrane Water Electrolyzers with Ultra-Low Iridium Loadings

Reducing Ir loadings in proton exchange membrane water electrolyzer anodes is critical for lowering capital expenses. Loading reduction could be achieved by improving the Ir activity via doping/alloying and/or the development of advanced microstructures. However, the anode porous transport layer (PTL) is a comparatively simple component whose properties also impact Ir utilization. Therefore, well-designed PTLs may also enable reduced Ir loadings. In this work, we survey eight PTLs from various manufacturers to observe their impact on cell performance at low (0.4 mg Ir cm -2 ) and ultralow (0.1 mg Ir cm -2 ) Ir loadings. The PTLs were characterized by their microstructural properties, including porosity, particle size distribution, and pore size distribution. Electrochemical cell performance was correlated to PTL morphology, and it was found that PTLs with lower porosities and smaller particle and pore radii enabled good performance even at ultralow Ir loadings. 1000-h durability testing indicated that using lower porosity PTLs can significantly improve durability behavior. A runaway voltage phenomenon was observed during durability testing of cells with ultralow Ir loadings, which was caused by increases in both anode and cathode overpotentials. Furthermore, we observed that the beginning of test performance of 0.1 mg Ir cm -2 cells correlates to the 1000-h degradation rates of 0.4 mg Ir cm -2 cells, suggesting that for the Ir catalyst used in this work, short-term testing at ultralow loadings can be used as an indicator of long-term degradation at higher loadings.

08 HYDROGEN↗

Demand response event simulator and risk-aware bidding tool for industrial customers

Incentive Based Demand Response (IBDR) program participation delivers financial benefits to the consumers and resiliency benefits to the electricity grid. Effectively participating in these programs as an industrial consumer requires bidding strategies that balance financial risk with operational constraints. Existing bidding tools tend not to fully incorporate stochastic IBDR event modeling, program specific baseline and payment/penalty calculations, or demand reduction process control schemes that account for the cascading impacts of shutdown in complex facilities. Here, this work presents an IBDR event simulator and risk-aware bidding framework tool integrating three key components: a flexible, parameterized demand response event generator that rigorously accounts for program structures and stochasticity, a demand response operational simulation model that generates explicit control strategies for load reduction, and a Monte Carlo simulator to evaluate financial risk for varied capacity bids. A case study at a wastewater treatment plant participating in PG&E's Capacity Bidding Program demonstrates the framework's utility. In the peak capacity price month of August, optimal bidding by the wastewater treatment plant nets a mean IBDR benefit of $101,000 (67% of the August electricity bill) with 0.4% probability of a financial loss. This framework enables industrial operators to make informed bidding decisions, negotiate better program terms with demand response load aggregators, and analyze energy flexibility investments at their facilities. Ultimately, this work reduces participation barriers in IBDR programs and supports the broader goal of enhancing grid reliability and renewable energy integration.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Co-optimization of repairs and dynamic network reconfiguration for improved distribution system resilience

In this work, a post-disaster distribution system repair and restoration (DSRR) strategy is proposed to improve distribution system resilience. The DSRR strategy is formulated as a two-stage optimization. The first stage is a comprehensive co-optimization of repair crew scheduling, dynamic network reconfiguration, and distributed energy resource (DER) dispatch based on the forecast load profile. The goal is to minimize the accumulative operating cost caused by the load reduction payment as well as DER operating cost. In particular, since the number of available repair crews is usually smaller than the number of faulted lines after a disaster event, the DSRR strategy determines the optimal scheduling for repairing faulted lines. The second stage is a re-dispatch of the DER power output and load shedding based on the real-time load demand of each bus. The proposed algorithm is validated by case studies of the IEEE 33-bus and 123-bus test systems. We consider those scenarios in which faults occur in multiple heavy-loaded feeders. The simulation results demonstrate that the DSRR strategy effectively coordinate the repair scheduling, network reconfiguration and load shedding to minimize the operating cost.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Network reconfiguration and distributed energy resource scheduling for improved distribution system resilience

Electric utility companies work to restore as much load as possible after power outages caused by extreme weather events. In this paper, an outage management strategy is proposed to enhance distribution system resilience through network reconfiguration and distributed energy resources (DERs) scheduling. After a line fault, the proposed algorithm can identify radial network topology based on the rank of the incidence matrix. The reconfiguration is implemented by switching tie lines and sectionalizing lines. With the new network topology, an optimal DER scheduling problem is solved to minimize the accumulative cost for dispatchable DER operation and load reduction. Finally, the optimal topology that minimizes the accumulative cost is selected from all radial topologies. The computational workload is relatively low because only linear programming needs to be solved. Using the case studies of the IEEE 69-bus and IEEE 123-bus systems, we consider the worst-case scenarios in which faults occur in the upstream feeder. The simulation results demonstrate that the proposed strategy allows for a relatively high percentage of the load to remain in service after line faults. Furthermore, compared with microgrid-formation approaches, the proposed strategy has advantages when applied to the distribution systems with several normally-open tie lines and low DER penetration.

42 ENGINEERING↗

Microgrid Tiered Circuits Effects for a Planned Housing Community in Puerto Rico

Puerto Rico faced a double strike from hurricanes Irma and Maria in 2017. The resulting damage required a comprehensive rebuild of electric infrastructure. There are plans and pilot projects to rebuild with microgrids to increase resilience. This paper provides a techno-economic analysis technique and case study of a potential future community in Puerto Rico that combines probabilistic microgrid design analysis with tiered circuits in building energy modeling. Tiered circuits in buildings allow electric load reduction via remote disconnection of non-critical circuits during an emergency. When coupled to a microgrid, tiered circuitry can reduce the chances of a microgrid's storage and generation resources being depleted. The analysis technique is applied to show 1) Approximate cost savings due to a tiered circuit structure and 2) Approximate cost savings gained by simultaneously considering resilience and sustainability constraints in the microgrid optimization. The analysis technique uses a resistive capacitive thermal model with load profiles for four tiers (tier 1-3 and non-critical loads). Three analyses were conducted using: 1) open-source software called Tiered Energy in Buildings and 2) the Microgrid Design Toolkit. For a fossil fuel based microgrid 30% of the total microgrid costs of 1.18 million USD were calculated where the non-tiered case keeps all loads 99.9% available and the tiered case keeps tier 1 at 99.9%, tier 2 at 95%, tier 3 at 80% availability, with no requirement on non-critical loads. The same comparison for a sustainable microgrid showed 8% cost savings on a 5.10 million USD microgrid due to tiered circuits. The results also showed 6-7% cost savings when our analysis technique optimizes sustainability and resilience simultaneously in comparison to doing microgrid resilience analysis and renewables net present value analysis independently. Though highly specific to our case study, similar assessments using our analysis technique can elucidate value of tiered circuits and simultaneous consideration of sustainability and resilience in other locations.

building energy modeling↗

Effectiveness of Residue and Tillage Management on Runoff Pollutant Reduction from Agricultural Areas

Highlights No-till and no-till residue systems were effective in reducing runoff particulate and total nutrients but increased dissolved nutrients. Maintaining >30% residue cover reduced most runoff constituents, irrespective of no-till or tillage. No-till-residue prevented runoff nutrient losses and benefitted farm revenue by avoiding tillage. Abstract. Reduced tillage management conservation practices (No-till and Reduced-till) are widely adopted in agriculture; however, understanding their overall effectiveness for water quality protection is challenging. A meta-analysis was conducted to understand and quantify the effectiveness of residue and tillage management on runoff, sediment, and nutrient losses from agricultural fields. Annual runoff and the associated sediment, and nutrient (nitrogen and phosphorus) loads were compiled from 60 peer reviewed research articles published across the United States and Canada. A total of 1575 site-years of data were categorized into tillage (<30% surface cover), no-tillage (<30% surface cover), tillage with residue (>30% surface cover), no-tillage with residue (>30% surface cover), and pasture management. No-tillage, no-tillage-residue, and tillage-residue managements were evaluated for their effectiveness in reducing runoff, nutrients, and sediment loads compared to tillage. Synthesized and surveyed corn yield data were used to evaluate the economic cost effectiveness of no-tillage-residue management with respect to tillage. Across the site years (1968-2019) studied, median runoff depth for no-tillage and no-tillage-residue were 84% and 70% greater than tillage and tillage-residue management, respectively. No-tillage-residue management had up to 86% less sediment losses than tillage systems, on average, for both >30% and <30% surface cover. No-tillage-residue management was most effective, with a positive performance effectiveness of 65% to 90% in controlling sediments, particulate, and total nutrient losses in runoff compared to tillage. Cost effectiveness analysis revealed the benefits of no-tillage-residue management in reducing nutrient loads and increasing net-farm revenue by avoiding tillage operational costs. Except for dissolved phosphorus, no-tillage-residue management cost effectiveness for sediments and nutrient loads ranged from negative $6 to negative $102 per every Mg or kg of load reduction, indicating it had both economic and environmental benefits compared to tillage management. Overall, these results indicate that over the long-term, no-tillage and tillage, combined with greater than 30% residue cover, can effectively reduce sediment and nutrient losses. This work highlights the importance of crop residues on the soil surface to reduce runoff losses, even in no-tillage systems. Keywords: Conservation tillage, No-tillage, Residue cover, Tillage, Water quality.

Agriculture↗

Preparing Distribution Utilities for the Future - Unlocking Demand-Side Management Potential: A Novel Analytical Framework

The balance of supply and demand in the power systems has traditionally been served solely through generation and network capacity planning and operations. However, with increased requirements for flexibility due to the uptake in variable renewable generation sources such as wind and solar there is a need to increased demand-side flexibility. In addition, there are increased communications and flexibility capabilities emerging on the demand-side from the adoption of advanced metering infrastructures and smart meter deployment and intelligent loads such as smart thermostats and schedulable white goods (e.g. dishwashers and washing machines). Unlocking demand-side flexibility can bring system benefits from peak load reduction bringing about generation capacity and network upgrade deferral, to reducing demand and more efficient utilization of generation and network capacity. Unlocking demand-side flexibility is an evolving process for utilities and solutions must be tailored to each specific customer group. Demand-side management (DSM) is a broad set of tools that can include demand response (both dispatchable and non-dispatchable), energy efficiency and distributed energy resources and demand-side technologies. The National Renewable Energy Laboratory (NREL), in collaboration with BSES Rajdhani Power Ltd. (BRPL) and Deloitte, examined the potential of DSM in BRPL’s service territory, developing detailed information on customer classes and willingness to participate in DSM. The study developed modeling frameworks for load analysis and the analysis tools to assess the potential of time-of-use tariffs in motivating customers to reduce their peak period energy consumption. The study shows that BRPL customers, specifically their domestic customers, are willing to participate in DSM programs and that time-of-use pricing can help BRPL reduce their peak demand and help unlock demand-side flexibility.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Austin Sustainable and Holistic Integration of Energy Storage and Solar PV [Austin SHINES]. Final Report, Version 2

The Austin SHINES project and solution is a software management platform, for an electric grid with a high penetration of dispersed photovoltaic (PV) solar generation sites, which maintains the traditional power quality and reliability associated with grid service. This project developed and deployed the platform as a Distributed Energy Resource Management System (DERMS), engaging multiple advanced controls, to evaluate operation and optimization of a fleet of diverse DER assets, installed at several locations among Austin Energy’s customers and distribution system. The project also produced a methodology to create a replicable DERMS template, adaptable to other regions and market structures. Last, Austin SHINES aimed to demonstrate the solution’s methodology would enable the DER grid ecosystem to serve load at a technical cost (System Levelized Cost of Electricity, or System LCOE) of less than the U.S. Department of Energy SHINES program metric of $0.14/kWh, in a defined boundary, while enabling a high penetration of distributed PV. Research was categorized in 6 reports (Final Deliverables = FD) listed below, with titles and descriptions indicating which area of understanding was investigated: FD-1: System Levelized Cost of Electricity (System LCOE) Methodology The creation and use of the System LCOE to Serve Load metric that encompasses the holistic, system-level costs and benefits of all resources, and enables them to be evaluated based on their ability to support an efficient and low-cost integrated grid ecosystem. FD-2: Software Platform Product Description The creation of new DER control methodologies deployable within a utility-grade software platform that enable DER's to maximize their benefit within a grid, that is capable of serving load enabling a high penetration of distributed PV generation. FD-3: Optimal Design Methodology Optimal design methodologies for individual DER installations that enable utilities to determine the optimal combinations and sizing for individual DER sites. FD-4: Austin SHINES Ownership and Operation Models for DER System Performance A comparison of multiple DER aggregation and ownership methodologies including direct utility control, third-party aggregator, and autonomous. FD-5: Economic Modeling & Optimization A comparison of multiple DER technology mixes and configurations within the distribution system, providing insight into an optimal blend of technologies that best enable the distribution system to serve load at the lowest cost at high penetrations of solar. FD-6: Fielded Assets Deployed DER assets within the Austin Energy SHINES circuits. Austin SHINES provided an opening for state-of-the-art technology products to be deployed, providing a rich opportunity for improving how each of the products perform as stand-alone products, and in concert with other complementary products. The Austin SHINES project comprised of two key metrics for System LCOE: SystemLCOE_SHINES<$0.14/kWh Modeled ΔSystemLCOE_SHINES/ΔSystemLCOE_Base≥20% at same solar penetration The System LCOE calculation uses the costs of the utility-owned infrastructure as it exists today, the cost of the DERs that exist in the system today, and the cost of the purchase of energy from ERCOT wholesale markets over the course of the calendar year. All costs are on an annualized basis. The capital and operating costs are derived from the rate case, which produces a yearly cost. The net cost of energy and services imported to the system is integrated over the test year, as is the load served and solar penetration. The first metric was easily achieved by every scenario considered. The goal was set when the Department of Energy’s SHINES Funding Opportunity Announcement was written in 2015 and was a more difficult target at the time. Due mostly to rapidly declining costs for DERs and the significant decrease in the Electric Reliability Council of Texas (ERCOT) energy market prices, which results in lower net cost of energy purchases, the System LCOE is well below this target for all scenarios considered. A fleet of DERs can assume different mixtures, each of which serves the load at a different LCOE. The optimal mixture of DERs serves load at the smallest System LCOE. The second metric (hereinafter %delta metric) asks that the holistic DERMS controls reduce the incremental cost above the baseline of going to a high solar penetration future by at least 20% as compared to the case of a DER deployment with no sophisticated controls (autonomous). Many comparison sets were created throughout this project. Physical technology was installed for informing utility engineering and testing several types of operational control schemes, through the DERMS. The types of operational control which were compared for valuation of the System LCOE Metric were: Holistic control = using the full suite of the DERMS platform to decide and optimize how/why the systems operate depending on weather, market, and reliability signal input. Autonomous control = a local mode at the asset site, wherein a schedule operates the asset, with visibility into performance only No control = the baseline for comparing value against the other two types of control The types of ownership control included: Direct Utility control = the utility dispatches a signal to each asset Third-Party Aggregator = a third party aggregates a fleet of assets and the utility dispatches one signal for all Autonomous = a local mode is set for operation at the asset site, wherein a schedule operates the asset, with visibility into performance only The types of control methodologies deployable within a utility-grade software platform included: Utility Peak Load Reduction = Lower transmission cost obligation Day-Ahead Energy Arbitrage = Realize economic value through price differential Real-Time Price Dispatch = Realize economic value from real-time price spikes Voltage support = Reduce losses and increase solar generation Distribution Congestion Management = Increase local grid reliability Demand Charge Reduction = Lower customer bills and realize system benefit The fielded assets deployed for the project were: Utility Scale Kingsbery Energy Storage System: 1.5 MW / 3 MWh Li-Ion battery storage Mueller Energy Storage System: 1.75 MW / 3.2 MWh Li-Ion battery storage, 7 Energy Storage Units (250 kW each) La Loma Community Solar: 2.6 MW Commercial Scale Aggregated storage installations at 3 sites, with existing solar (300+ kW): One 18 kW / 36 kWh Li-Ion battery storage Two 72 kW / 144 kWh Li-Ion battery storage Residential Scale Aggregated storage installations: -Six stationary battery storage systems (10 kWh each) at homes with existing solar -One Electric Vehicle installed as Vehicle-to-Grid (V2G) Utility-Controlled Solar via Smart Inverters at 12 homes Autonomously-Controlled Smart Inverters at 6 homes Over the course of the project, Austin SHINES undertook installing more than 3 MW of distributed battery energy storage, smart PV inverters, a DER control platform, and other enabling technologies utilizing customer and utility locations and aggregation models. All of these resources were to be integrated and optimized at the utility level. DER assets and control methodologies were designed to achieve a credible pathway to a System LCOE for energy delivered to load of $0.14//kWh or less by 2020, while maximizing distributed solar generation and maintaining acceptable standards of power quality. The project also established a template for other regions to follow, to maximize the adoption of distributed solar PV in support of an economic and efficient grid. In total, the Austin SHINES project added value to the DER subject area in each layer of integration. From utility, to commercial to residential scales, the sheer hierarchy of communication and coordination was a significant accomplishment in addition to learnings from what these communications revealed was unique to each. Economically, the most effective method demonstrated was the criticality of planning phases. Contingencies and multiple projection scenarios helped guide the project to deploy optimal design as close as feasible, in real world conditions. The project and reports will serve public benefit by outlining specific areas of DER strategy and installation where many stakeholders and needs can be addressed with improved efficiency. Overall, communities and utilities should use the results to guide the increasing options available for powering the grid with DER, renewables, and carbon considerate energy.

14 SOLAR ENERGY↗

Development and validation of a second-order thermal network model for residential buildings

Heating, Ventilation, and Air Conditioning (HVAC) systems can maintain the space air temperature of residential buildings, either directly by heating/cooling the air, or indirectly via heat transfer to and from the building structure that acts as a thermal mass. Hence, HVAC systems can help achieve load shifting, peak load reduction, and/or energy cost saving, thus enabling grid-interactive HVAC operation. A home thermal model that can accurately reflect the dynamics of the space air and interior wall surface temperatures, is therefore valuable. This paper develops such a model using the standard RC (resistance-capacitance) approach. The model contains a virtual envelope node and an internal space node and is thus second-order. A hybrid parameter identification scheme, made up of the least-squares and optimal search methods, is also developed. The proposed model and scheme were validated using data collected from a test home. It was found that a modest amount of training data was sufficient to yield reliable parameter estimates and accurate prediction. It was also found that when making 24-hour-ahead prediction of the space air temperature, both methods had comparable performances when the training data began in a transition season. However, when they began in an HVAC season, the optimal search method performed better. Furthermore, the least-squares method is recommended during a transition season due to its lower computational burden, while the optimal search method is recommended during an HVAC season due to its better estimation performance.

24 POWER TRANSMISSION AND DISTRIBUTION↗